• Best customer support

  • Payment via invoice or credit card

  • WORLDWIDE EXPRESS SHIPPING

  • Flow Control
    • Baoding Shenchen
    • Bartels
    • Elveflow
    • Harvard Apparatus
    • Ismatec
    • Jun-Air
    • LabTech
    • Longer
    • New Era
  • Chips & Microfabrication
    • BlackHole Lab
    • Grace Bio-Labs
    • iBioChips
    • IVTech
    • MesoBioTech
    • microfluidic ChipShop
    • SynVivo
  • Imaging
    • Fastec Imaging
    • Nikon
    • Pixelink
    • Zeiss
  • Accessories
    • BD
    • Diba
    • Elveflow
    • Emulseo
    • Masterflex
  • Sensors
    • Elveflow
    • MicruX
    • Zimmer & Peacock
  • Valves
    • Bürkert
    • Elveflow
    • Memetis
  • Store Location
  • Register or Sign in
0
Darwin Microfluidics
  • CHIPS & MICROFAB
    Off-the-shelf Chips
    • Droplet Generators
    • Micromixers
    • Flow Cells
    • Organ-on-a-Chip
    • Cell Culture
    Microfabrication
    • Soft-lithography Systems
    • Chip Prototyping Tools
  • INSTRUMENTS
    Pumps & Flow Controllers
    • Syringe Pumps
    • Peristaltic Pumps
    • Pressure Controllers
    • OEM Pumps & Accessories
    • Valves
    Cameras
    • USB Cameras
    • High-speed Cameras
    Microscopes
    Sensors
    • Electrochemical Sensors
    • Pressure Sensors
    • Flow Sensors
    Compressors & Vacuum Pumps
  • ACCESSORIES
    Accessories
    • Bubble Traps
    • Tanks & Reservoirs
    • Punchers
    • Filters & Check valves
    • Oils & Reagents
    Tubing
    • PTFE, PEEK, FEP Tubing
    • Silicone & Tygon Tubing
    • Tubing with stoppers
    Syringes & Needles
    • Syringes
    • Needles & Couplers
    Fittings & Connectors
    • Threaded Fittings
    • Luer Fittings
    • Barbed Fittings
    • Sleeves & Ferrules
    • Splitters & Manifolds
  • CONTACT US
(+33) 184 163 808 contact@darwin-microfluidics.com
Browse By Brand
  • Flow Control
    • Baoding Shenchen
    • Bartels
    • Elveflow
    • Harvard Apparatus
    • Ismatec
    • Jun-Air
    • LabTech
    • Longer
    • New Era
  • Chips & Microfabrication
    • BlackHole Lab
    • Grace Bio-Labs
    • iBioChips
    • IVTech
    • MesoBioTech
    • microfluidic ChipShop
    • SynVivo
  • Imaging
    • Fastec Imaging
    • Nikon
    • Pixelink
    • Zeiss
  • Accessories
    • BD
    • Diba
    • Elveflow
    • Emulseo
    • Masterflex
  • Sensors
    • Elveflow
    • MicruX
    • Zimmer & Peacock
  • Valves
    • Bürkert
    • Elveflow
    • Memetis
  • Get a Quote
  • 0
  • CHIPS & MICROFAB
    Back
    Off-the-shelf Chips
    • Back
    • Droplet Generators
    • Micromixers
    • Flow Cells
    • Organ-on-a-Chip
    • Cell Culture
    Microfabrication
    • Back
    • Soft-lithography Systems
    • Chip Prototyping Tools
  • INSTRUMENTS
    Back
    Pumps & Flow Controllers
    • Back
    • Syringe Pumps
    • Peristaltic Pumps
    • Pressure Controllers
    • OEM Pumps & Accessories
    • Valves
    Cameras
    • Back
    • USB Cameras
    • High-speed Cameras
    Microscopes
    Sensors
    • Back
    • Electrochemical Sensors
    • Pressure Sensors
    • Flow Sensors
    Compressors & Vacuum Pumps
  • ACCESSORIES
    Back
    Accessories
    • Back
    • Bubble Traps
    • Tanks & Reservoirs
    • Punchers
    • Filters & Check valves
    • Oils & Reagents
    Tubing
    • Back
    • PTFE, PEEK, FEP Tubing
    • Silicone & Tygon Tubing
    • Tubing with stoppers
    Syringes & Needles
    • Back
    • Syringes
    • Needles & Couplers
    Fittings & Connectors
    • Back
    • Threaded Fittings
    • Luer Fittings
    • Barbed Fittings
    • Sleeves & Ferrules
    • Splitters & Manifolds
  • CONTACT US
  • Call
  • Contact
  • Store info
  • Directions

172 rue de Charonne
Bâtiment B1, 1er étage
Paris, France

Currencies

EUR Euro (EUR)
  • USD US dollar (USD)
  • EUR Euro (EUR)
  • GBP British pound (GBP)
  • CAD Canadian dollar (CAD)
  • AUD Australian dollar (AUD)
  • Darwin MicrofluidicsHome
  • News
  • Bartels Evaluation Board Comparison

Bartels Evaluation Board Comparison

  • News
  • 26 Nov, 2020
  • Posted by: Christelle ANGELY

Comparison of the controller boards for the mp6 micropumps.

 Category mp6-OEM mp6-EVA* mp6-XOEM mp6-QuadOEM mp6-QuadKEY mp-x mp6-QuadEVA
Outputs  1 1 1 4 4 1 4
Frequency range 1-300 1-300 50-800 50-800 50-800 0-300 50-800
Independent frequency control no no no yes yes yes yes
Amplitude range 80-250 Vpp 80-250 Vpp 10-250 Vpp 10-250 Vpp 10-250 Vpp 0-250 Vpp 10-250 VppIn
Independent amplitude control no no no  yes yes yes yes
Signal shape OEM OEM sinusoidal, trapezoidal, rectangular sinusoidal, trapezoidal, rectangular sinusoidal, trapezoidal, rectangular SRS, rectangular, sinusoidal sinusoidal
Power supply 3 - 5 V USB or 3 - 5 V 3-5 V 3 - 5  V USB or 7,5 - 12 V 7,5 - 12 V 7,5 - 12 V
Interface TTL TTL (USB just for power) TTL or I2C I2C USB main adaptor USB, Buttons, Dials 
Size 10,5 x 20, 5 x 6 mm 6,5 x 3 x 2 cm 10,4 x 25,5 x 4,2 mm 38 x 18 x 12 mm 92 x 46 x 23 mm 7,5 x 16 x 20 cm 80 x 60 x 16 mm 

*The mp6-EVA evaluation board is based on the mp6-OEM module. 

Find all these products at Darwin Microfludic by clicking here!

 

  • Share
  • Tweet

Leave a comment

Comments have to be approved before showing up

welcome to our blog!
Our team keeps you informed of the latest news at Darwin Microfluidics. We also write some nice reviews and tools to guide you through the vast world of microfluidics!
Categories
  • News
  • Reviews
  • Tutorials
  • Tools
Recent posts
Bartels Evaluation Board Comparison
11 Jan, 2021
Blog
IC-Chip and DDI-Chip for 3D cell culture
01 Feb, 2019
Blog
Reservoir Holder for Eppendorf®: a convenient and sturdy setup
16 Nov, 2018
Tags
  • All
  • cell culture
  • microfluidic chip
  • new products

Recently Viewed

Ismatec - Darwin Microfluidics
Elveflow - Darwin Microfluidics
Microfluidic ChipShop - Darwin Microfluidics
Zeiss - Darwin Microfluidics
Harvard Apparatus - Darwin Microfluidics
Cole-Parmer - Darwin Microfluidics
Sign up to our Newsletter

...for latest news in microfluidics.

Darwin Microfluidics
Got questions? Call us! (+33) 184 163 808
Contact info Darwin Microfluidics
172 rue de Charonne
Bâtiment B1, 1er étage
75011 Paris
France
  • Social
Blog
  • News
  • Reviews
  • Tutorials
  • Tools
Informations
  • Bank Informations
  • General Terms & Conditions
  • Delivery Terms
  • Payment Terms
The Company
  • About us
  • Careers
  • Contact us

© 2021 Darwin Microfluidics. All Rights Reserved

  • Payment

Product successfully added to your Shopping Cart

Request a Quote
Proceed to Checkout