{"id":14528,"date":"2023-02-22T18:28:50","date_gmt":"2023-02-22T17:28:50","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14528"},"modified":"2024-02-27T12:02:50","modified_gmt":"2024-02-27T11:02:50","slug":"the-most-used-microfabrication-materials-for-microfluidics","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/","title":{"rendered":"The most used microfabrication materials for microfluidics"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14528\" class=\"elementor elementor-14528\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7964d23 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7964d23\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-467fa74\" data-id=\"467fa74\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-af6f594 elementor-widget elementor-widget-text-editor\" data-id=\"af6f594\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Wahl des richtigen Materials für die Entwicklung mikrofluidischer Chips ist von entscheidender Bedeutung und keineswegs trivial. Das ausgewählte Material muss optische Eigenschaften aufweisen, die denen von Glas (oder idealerweise Quarzglas) für eine optimale Detektion nahekommen, Oberflächeneigenschaften besitzen, die die Adsorption von Biomolekülen sowie Elektroosmose verhindern, und zudem die präzise Reproduktion mikrometergroßer Strukturen ermöglichen.</p><p>(Poly)dimethylsiloxan (PDMS), Polymethylmethacrylat (PMMA), Polycarbonat (PC), Polystyrol (PS), Polyimid und Polyethylen (PE) gehören zu den Polymerwerkstoffen, die häufig für die Herstellung von Chips verwendet werden. Darunter ist PDMS das beliebteste Substrat. In jüngerer Zeit hat SU-8-Resin Einzug in den Markt der Mikrofabrikation für mikrofluidische Chips gehalten. Cyclische Olefin-Copolymere (COC) und Polyethylenglycoldiacrylat (PEGDA) sind ebenfalls weit verbreitete Materialien für die Herstellung mikrofluidischer Chips.</p><p>In diesem Übersichtsartikel bietet Ihnen unser Expertenteam einen umfassenden Überblick über die am häufigsten verwendeten Materialien in der Mikrofluidik, damit Sie das für Ihre Anwendung ideale Material auswählen können.</p><h3>Die am häufigsten verwendeten Materialien in der Mikrofluidik</h3><p>Die Verarbeitung von Polymeren ist unkompliziert, und ihr Einsatz als Werkstoff reduziert Zeit, Komplexität sowie Kosten beim Prototypenbau und in der Fertigung. Mikrofluidische Systeme werden im Allgemeinen durch das Formen und Bonden von Repliken aus Elastomeren wie PDMS oder Thermoplasten wie PMMA oder PC hergestellt. Andere Werkstoffe wie COC oder SU-8 erfreuen sich in der Mikrofluidik zunehmender Beliebtheit. Diese Polymere verdanken ihren Erfolg vier wesentlichen Eigenschaften: Biokompatibilität, Transparenz, geringe Kosten und selbstverständlich das Fehlen von Urheberrechtsbeschränkungen.</p><h4>Polydimethylsiloxan oder PDMS</h4><p>Ein erheblicher Anteil mikrofluidischer Chips wird aus PDMS hergestellt. Einer der Hauptvorteile dieses Materials ist seine hohe optische Transparenz im sichtbaren und ultravioletten Bereich, wodurch es sich für zahlreiche fluoreszenzbasierte Anwendungen eignet. Ein weiterer Vorzug von PDMS ist seine Gaspermeabilität, die die Zellkultivierung in mikrofluidischen Vorrichtungen aus diesem Material ermöglicht. Auch die Herstellung wird durch PDMS erleichtert, da die Chips einfach aus einer Form mit dem Negativrelief eines gewünschten Musters gefertigt werden. Das vorstrukturierte Muster lässt sich mithilfe standardmäßiger <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/photolithography-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">Photolithographieverfahren</a> realisieren, wobei für die Montage von PDMS-Chips nur eine minimale Reinrauminfrastruktur erforderlich ist. PDMS eignet sich hervorragend für Prototyping-Techniken, was es zu einem bevorzugten Material in der Mikrofluidik macht.</p><p>Neben all seinen Vorzügen wurden auch einige Nachteile bei der Verwendung von PDMS als Vorrichtung zur <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">Absorption</a> von Wirkstoffen <em>[Regehr KJ et al. 2009 Lab Chip]</em> oder anderen Molekülen nach einer Oxidation von PDMS berichtet <em>[McDonald et al. 2000 Electroph.]</em>, was Forscher dazu veranlasst hat, Vorrichtungen aus anderen Materialien herzustellen. Weitere Nachteile von PDMS sind beispielsweise das Quellen in organischen Lösungsmitteln (was das Spektrum mikrofluidischer Anwendungen einschränkt), eine geringe mechanische Festigkeit (die zum Kollabieren von Strukturen mit hohem Aspektverhältnis im Bauteil führt) sowie instabile Oberflächenmodifikationen <em>[Paul et al. 2007 Electroph.]</em>.</p><h4>Polymethylmethacrylat oder PMMA</h4><p>PMMA ist ein transparentes Thermoplast, dessen Monomer Methylmethacrylat (MMA) ist. Dieses Polymer ist besser unter seinem ursprünglichen Handelsnamen Plexiglas bekannt. PMMA bietet zahlreiche Vorteile wie Transparenz, Beständigkeit und seine amorphe Beschaffenheit. Daher ermöglicht es eine hervorragende Lichttransmission von bis zu 92 % des sichtbaren Lichts, was mehr als bei Glas ist <em>[Good Fellow Website]</em>.</p><p>PMMA ist relativ kratzempfindlich (stärker als herkömmliche mineralische Linsen) und neigt bei Zusatzstoffen zur Sprödigkeit. Zudem weist es eine vergleichsweise geringe Beständigkeit gegenüber vielen Chemikalien auf und löst sich in zahlreichen organischen Lösungsmitteln. Seine Umweltbeständigkeit ist jedoch besser als die der meisten anderen Kunststoffe.</p><h4>Polycarbonat oder PC</h4><p>PC ist ein thermoplastischer Polymer. Verglichen mit anderen in der Mikrofluidik verwendeten Materialien, wie beispielsweise COC (Cycloolefin-Copolymer), ist es weniger <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/hydrophobic-microfluidic-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">hydrophob</a> und die Kanäle weisen folglich ein besseres Benetzungsverhalten auf. Idealerweise wird es für Hochtemperaturanwendungen wie die PCR eingesetzt.</p><p>Der tatsächliche Nachteil von Polycarbonat liegt in seiner im Vergleich zu beispielsweise PMMA relativ hohen Eigenfluoreszenz. Dieser Nachteil beeinträchtigt die Fluoreszenzmikroskopie erheblich und schränkt daher dessen Anwendung ein.</p><h4>Cycloolefin-Copolymer oder COC</h4><p>Cycloolefin-Copolymer (COC) ist ein amorpher Polymer. Verglichen mit Standardkunststoffen wie Polypropylen und Polyethylen stellt COC eine relativ neue Polymerklasse dar. Cycloolefin-Copolymer ist ein Material, das sich hervorragend für mikrofluidische Anwendungen eignet. Die Liste seiner Vorteile ist lang und umfasst eine gute Biokompatibilität, geringe Wasser<a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">absorption</a>, eine gute chemische Beständigkeit sowie eine hohe Transparenz im tiefen UV-Bereich.</p><p>Aufgrund seiner zahlreichen Vorzüge lässt sich COC selbstverständlich für die Herstellung von Chips in diversen Bereichen einsetzen, wie etwa für die Analyse von Parametern wie Blutgasen, Glucose- und Laktatkonzentrationen oder für die Bestimmung des Hämatokritwerts. Da die Kanalwände zudem UV-transparent sind, ermöglichen sie die Verwendung von UV-Initiatoren wie Benzophenon, das häufig beim Western Blotting eingesetzt wird.</p><h4>SU-8-Harz</h4><p>SU-8 ist ein negativer photoresistiver Lack, der häufig bei der Herstellung von Mikrosystemen verwendet wird. SU-8-Harz besteht aus Epoxidharz, Propylencarbonat, einem Triarylsulfonium-Initiator und einem organischen Lösungsmittel. Aufgrund seiner Zusammensetzung handelt es sich bei SU-8 um einen hochviskosen Polymer, der in Schichtdicken von 1 Mikrometer bis 2 Millimeter aufgetragen und im Allgemeinen mittels <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/photolithography-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">Photolithographie</a> strukturiert wird. Es wird zunehmend für die Herstellung von Formen verwendet, da es eine exzellente chemische Beständigkeit gegenüber diversen Säuren und Basen sowie eine hohe thermische Stabilität aufweist. Darüber hinaus ist SU-8 mechanisch zuverlässig, optisch transparent und hydrophil. Diese Eigenschaften machen SU-8 zu einem äußerst attraktiven Material für ein breites Anwendungsspektrum – wie natürlich mikrofluidische Anwendungen, aber auch für die Mikrooptik, Mikromaschinenbearbeitung, das Packaging oder analytische Anwendungen.</p><p>SU-8 wird selten als eigenständiger Chip verwendet, sondern vielmehr als Form in Kombination mit anderen Materialien wie PDMS oder Silikon.</p><h4>Polyethylenglykol-Hydrogele oder PEGs</h4><p>PEGs sind Hydrogele, die signifikante Vorteile gegenüber anderen Biomaterialien bieten. Im Gegensatz zu natürlichen Biomaterialien sind PEGs synthetisch, was eine absolute Kontrolle über mechanische Eigenschaften wie das Elastizitätsmodul und die Degradationsrate ermöglicht. Dies bedeutet zudem, dass PEG im Vergleich zu Materialien natürlichen Ursprungs eine geringere Chargenvariabilität aufweist. Die chemische Zusammensetzung dieser Hydrogele macht sie stark hydrophil, resistent gegen Proteinadsorption und biokompatibel. Es gibt eine Vielzahl chemischer Gruppen, die in PEG-Makromere eingebaut werden können, um die Polymerisation und die Vernetzung des Netzwerks zu erleichtern (Acrylat, Methacrylat, Vinylether, Norbornen usw.) <em>[Amy H et al. 2013 Chem J].</em></p><p>Zu den Materialeigenschaften von fundamentaler Bedeutung können die Bearbeitbarkeit, die Oberflächenladung, die molekulare Adsorption, die elektroosmotische Strömungsmobilität, die optischen Eigenschaften und viele weitere gehören. Die Wahl des Substrats ist daher sowohl für den Herstellungsprozess als auch für die erfolgreiche Anwendung des Chips von entscheidender Bedeutung. Um Sie bei Ihrer Auswahl zu unterstützen, bietet Darwin Microfluidics ein breites Sortiment an mikrofluidischen Geräten an, die verschiedene Designs und Materialien kombinieren und mit einer Vielzahl von Anwendungen kompatibel sind.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68c72a0 elementor-widget elementor-widget-global elementor-global-18322 elementor-widget-pix-promo-box\" data-id=\"68c72a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Microfabrication_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"AUF DER SUCHE NACH PRÄZISION IM NANOMETERBEREICH?\"><a href=\"https://darwin-microfluidics.com/de/collections/mikrofabrikation\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Entdecken Sie unsere Auswahl!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">AUF DER SUCHE NACH PRÄZISION IM NANOMETERBEREICH?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Entdecken Sie unsere Mikrotechnologie-Lösungen für eine präzise und skalierbare Fertigung!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Choosing the right material for the development of microfluidic devices is critical and not insignificant, as the chosen material must combine optical qualities close to those of glass (or ideally fused silica) for optimal detection, surface properties avoiding adsorption of…</p>\n","protected":false},"author":3,"featured_media":14757,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[25,21],"tags":[],"class_list":["post-14528","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-microfabrication","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Die am häufigsten verwendeten Materialien für die Mikrofabrikation in der Mikrofluidik</title>\n<meta name=\"description\" content=\"In diesem Übersichtsartikel bietet Ihnen unser Expertenteam einen fundierten Überblick über die am häufigsten verwendeten Materialien in der Mikrofluidik, damit Sie das optimale Material auswählen können!\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Die am häufigsten verwendeten Materialien für die Mikrofabrikation in der Mikrofluidik\">\n<meta property=\"og:description\" content=\"In diesem Übersichtsartikel bietet Ihnen unser Expertenteam einen fundierten Überblick über die am häufigsten verwendeten Materialien in der Mikrofluidik, damit Sie das optimale Material auswählen können!\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-22T17:28:50+00:00\">\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:02:50+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp\">\n\t<meta property=\"og:image:width\" content=\"1000\">\n\t<meta property=\"og:image:height\" content=\"1000\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"5 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"The most used microfabrication materials for microfluidics\",\"datePublished\":\"2023-02-22T17:28:50+00:00\",\"dateModified\":\"2024-02-27T11:02:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\"},\"wordCount\":1096,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp\",\"articleSection\":[\"Microfabrication\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\",\"url\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\",\"name\":\"The most used microfabrication materials for microfluidics\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp\",\"datePublished\":\"2023-02-22T17:28:50+00:00\",\"dateModified\":\"2024-02-27T11:02:50+00:00\",\"description\":\"In diesem Übersichtsartikel bietet Ihnen unser Expertenteam einen fundierten Überblick über die am häufigsten verwendeten Materialien in der Mikrofluidik, damit Sie das optimale Material auswählen können!\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp\",\"width\":1000,\"height\":1000,\"caption\":\"photograph of a PDMS bottle\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The most used microfabrication materials for microfluidics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Unser Blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/de\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"The most used microfabrication materials for microfluidics","description":"In diesem Übersichtsartikel bietet Ihnen unser Expertenteam einen fundierten Überblick über die am häufigsten verwendeten Materialien in der Mikrofluidik, damit Sie das optimale Material auswählen können!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/","og_locale":"en_US","og_type":"article","og_title":"The most used microfabrication materials for microfluidics","og_description":"In this review, our team of experts gives you a good overview of the most used materials in microfluidics, so you can choose the best one!","og_url":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T17:28:50+00:00","article_modified_time":"2024-02-27T11:02:50+00:00","og_image":[{"width":1000,"height":1000,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"5 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"The most used microfabrication materials for microfluidics","datePublished":"2023-02-22T17:28:50+00:00","dateModified":"2024-02-27T11:02:50+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/"},"wordCount":1096,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","articleSection":["Microfabrication","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/","url":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/","name":"The most used microfabrication materials for microfluidics","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","datePublished":"2023-02-22T17:28:50+00:00","dateModified":"2024-02-27T11:02:50+00:00","description":"In diesem Übersichtsartikel bietet Ihnen unser Expertenteam einen fundierten Überblick über die am häufigsten verwendeten Materialien in der Mikrofluidik, damit Sie das optimale Material auswählen können!","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","width":1000,"height":1000,"caption":"photograph of a PDMS bottle"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"The most used microfabrication materials for microfluidics"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Unser Blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14528","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14528"}],"version-history":[{"count":8,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14528/revisions"}],"predecessor-version":[{"id":18409,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14528/revisions/18409"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14757"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14528"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14528"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14528"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}