{"id":14570,"date":"2023-02-23T15:10:30","date_gmt":"2023-02-23T14:10:30","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14570"},"modified":"2026-11-19T15:13:18","modified_gmt":"2026-11-19T14:13:18","slug":"characterization-of-the-droplet-size-for-various-microfluidic-designs","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/","title":{"rendered":"Characterization of the droplet size for various microfluidic designs"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14570\" class=\"elementor elementor-14570\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5f742ec elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5f742ec\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-00a620f\" data-id=\"00a620f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a6158d3 elementor-widget elementor-widget-text-editor\" data-id=\"a6158d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In diesem Übersichtsartikel untersuchen wir zwei der am häufigsten verwendeten Designs für die Tröpfchenerzeugung: <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-Junction</a> und Flow-Focusing. Zuerst besprechen wir, wie es möglich ist, die Tröpfchengröße in der Mikrofluidik vorherzusagen. Anschließend stellen wir die Ergebnisse vor, die wir für zwei Chips mit zwei gängigen fluorierten Ölen erzielt haben, basierend auf der Verwendung eines Druckreglersystems und mikrofluidischer Chips von Darwin Microfluidics.</p><h2>Material</h2><p>Für unsere Charakterisierung wählten wir einen Druckregler und zwei Chip-Typen: einen PDMS-Chip mit einer Flow-Focusing-Geometrie und einen Polycarbonat-Chip mit verschiedenen T-Junction-Designs (siehe Abbildung 1).</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15f74d3 elementor-widget elementor-widget-image\" data-id=\"15f74d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"474\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Used_equipment_for_the_droplet_size_characterisation-1-768x569.webp\" class=\"attachment-medium_large size-medium_large wp-image-14572\" alt=\"Fotografie der Ausrüstung, die für die Charakterisierung der Tröpfchengröße benötigt wird\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Used_equipment_for_the_droplet_size_characterisation-1-768x569.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Used_equipment_for_the_droplet_size_characterisation-1-300x222.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Used_equipment_for_the_droplet_size_characterisation-1-1024x759.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Used_equipment_for_the_droplet_size_characterisation-1.webp 1039w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Abbildung 1: Mikrofluidische Ausrüstung zur Durchführung der Studie zur Tröpfchencharakterisierung. A) Von Elveflow entwickelter Druckregler. Dieses Steuersystem eignet sich für hochpräzise Anwendungen und anspruchsvolle mikrofluidische Experimente. B) Dieser aus PDMS hergestellte Tröpfchengenerator-Chip kombiniert 11 Chips auf einem Standard-Objektträger, um monodisperse Emulsionen mittels Flow-Focusing-Geometrie zu erzeugen. C) Diese T-Junction-Tröpfchengenerator-Chips verfügen über mehrere Ein- und Auslässe für alle Arten von Experimenten. Erzeugen Sie Tröpfchen verschiedener Volumina dank der zahlreichen Designs auf einem einzigen Chip.</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-53ce9fe elementor-widget elementor-widget-text-editor\" data-id=\"53ce9fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diese Experimente ermöglichten es uns, die Größe der Tröpfchen in Abhängigkeit von den unterschiedlichen Geometrien der tröpfchenerzeugenden Systeme sowie von der Art des verwendeten Öls zu bewerten (FluoDrop 40 und <span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https://darwin-microfluidics.com/de/collections/microfluidic-liquids-chemicals/produkte/fluorinated-oil-for-microfluidics?variant=36766353850532\">FluoDrop 7500</a></strong></span> (mit 2% <span style=\"color: #0000ff;\"><strong><span style=\"text-decoration: underline;\"><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https://darwin-microfluidics.com/de/collections/microfluidic-liquids-chemicals/produkte/fluosurf-hochleistungs-tensid-fur-droplet-generator?variant=29556657487917\">FluoSurf</a></span></strong></span>), bei denen es sich um die am häufigsten verwendeten fluorierten Öle in der Mikrofluidik handelt).</p><h2>Wie lässt sich die Tröpfchengröße vorhersagen?</h2><p><span style=\"color: inherit; font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1rem; letter-spacing: -0.01rem;\">Der erforderliche Schritt in allen tröpfchenbasierten Systemen ist die Tröpfchenbildung. Ein Tröpfchengenerator muss eine anwendungsspezifische Leistung erbringen, die eine vorgeschriebene Tröpfchengröße und Er Frequenz umfasst und gleichzeitig monodisperse Tröpfchen erzeugt. Die gewünschte Leistung wird in der Regel durch mehrere kosten- und zeitintensive Designiterationen erreicht.</span></p><p>Um diesen Schritt der Tröpfchenbildung zu erleichtern, wurden mehrere Studien durchgeführt, um die Größe der Tröpfchen anhand der Geometrie des „ droplet generator “ und der Viskosität der verwendeten kontinuierlichen Phase vorherzusagen.</p><p>Beispielsweise zeigen Prileszky und Mitarbeiter, dass die Größe der in einem <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-Junction</a> erzeugten Tröpfchen gamma-verteilt ist (siehe Abbildung 2), was zusätzliche Einblicke in die Physik des Aufbrechprozesses und die Eigenschaften von in der Mikrofluidik erzeugten Emulsionen liefert. Sie zeigen, dass die Größe der in einer <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-Junction</a> erzeugten Tröpfchen durch eine Gammastrahlung verteilt wird, was ein besseres Verständnis der Physik des Aufbrechprozesses und der Eigenschaften der in der Mikrofluidik erzeugten Emulsionen ermöglicht. Die Kenntnis der zugrundeliegenden Wahrscheinlichkeitsverteilung ermöglicht die Steuerung der Tröpfchengröße für Tröpfchen aus viskosen Materialien. Das Verständnis, wie die Viskosität der dispersen Phase die Tröpfchengröße beeinflusst, ist entscheidend, um Tröpfchen mit der korrekten Geometrie und den gewünschten Eigenschaften zu erzeugen <strong>[Prileszky et al. 2016 AIChE Journal]</strong>.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-008b490 elementor-widget elementor-widget-image\" data-id=\"008b490\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"631\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp\" class=\"attachment-medium_large size-medium_large wp-image-14574\" alt=\"Diagramm der Gamma-Verteilung der Tröpfchen\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp 640w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1-300x296.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1-75x75.webp 75w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Abbildung 2: Die Gamma-Verteilung beschreibt die meisten Datensätze gut. Die Anderson-Darling-Statistik (AD) ist für die Gamma-Verteilung nicht nur für alle Datensätze niedriger als bei jedem anderen Modell, sondern keine andere Verteilung weist konsistent p-Werte größer als 0,05 auf. Der Datenmittelwert dieses Histogramms beträgt 101,6 µm bei einem Variationskoeffizienten von 0,11. Entnommen aus Prileszky et al. 2016 AIChE Journal</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-afadf4b elementor-widget elementor-widget-text-editor\" data-id=\"afadf4b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Gamma-Verteilung scheint das am besten geeignete Modell zu sein und übertrifft sogar die weitaus häufiger verwendete log-normale Verteilung, was durch die große Diskrepanz zwischen den Anderson-Darling-Statistiken (dieser Test misst den Abstand zwischen einer hypothetischen Verteilung und dem empirischen Modell über die gesamte kumulative Verteilungsfunktion (CDF) der hypothetischen Verteilung) und den zugehörigen p-Werten aus repräsentativen Wahrscheinlichkeitsdiagrammen belegt wird.</p><p>Die Entwicklung einer probabilistischen Beschreibung eines physikalischen Prozesses führt zur Korrelation der Messungen mit den physikalischen Parametern. Ohne das Verständnis der Form der Verteilung einer Zufallsvariablen führt systematisches Rauschen in experimentellen Daten direkt zu systematischen Fehlern in einer vorgeschlagenen Korrelation. Durch das Herausfiltern des Rauschens durch Vergleich einer experimentellen Verteilung mit einer theoretischen Verteilung ist es jedoch möglich, den Mittelwert der realen Verteilung besser zu schätzen, indem die Fehlerfortpflanzung durch Regressionsanalysen minimiert wird. Folglich ermöglicht die Identifizierung der Gamma-Verteilung als repräsentativ für die Variabilität der Größe von Tröpfchen, die in einer <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-Junction</a> gebildet werden, eine genauere Korrelation der Tröpfchengröße mit der Viskosität und der Durchflussrate der dispersen Phase <strong>[Prileszky et al. 2016 AIChE Journal]</strong>.</p><p>Eine weitere Methode zur Vorhersage der Tropfengröße ist die numerische Simulation mittels der COMSOL-Software. In diesem Beispiel wird der Prozess der Tröpfchenbildung in einer mikrofluidischen Flow-Focusing-Struktur untersucht. Dabei wurden mehrere Erkenntnisse gewonnen: Es zeigte sich, dass die Genauigkeit der numerischen Lösung mit der Wasserflussrate zunimmt. So sank der durchschnittliche Fehler von 14,6 auf 6,96 %, als die Wasserflussrate von 0,3 auf 0,6 µL/min erhöht wurde. Anschließend wurde die Variation des Tröpfchenradius als Funktion des Flussverhältnisses und der Anzahl der Kapillaren untersucht. Es wurde festgestellt, dass diese beiden Parameter – und nicht der Wasser- und Ölfluss – die Hauptfaktoren sind, welche die Tröpfchengröße beeinflussen. Schließlich zeigte sich, dass die Kapillarzahl im Vergleich zum Flussverhältnis eine dominantere Rolle bei der Bestimmung des Tröpfchenradius spielt<strong> [Lashkaripour et al. 2015 JAMECH]</strong>.</p><h2>Charakterisierung der Tröpfchengröße für zwei Standard-Chips (Flow-Focusing und T-Junction)</h2><p>Zur Durchführung dieser Charakterisierung haben wir uns entschieden, die Größe der durch Flow-Focusing und <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-junction</a> erzeugten Tröpfchen mit zwei in der Mikrofluidik weit verbreiteten fluorierten Ölen zu evaluieren. In der folgenden Tabelle sind die erzielten Ergebnisse aufgeführt.</p><table width=\"100%\"><tbody><tr><td><strong>Geometrie des Tröpfchengenerators</strong></td><td><strong>Tröpfchengröße (µm) mit FluoDrop 40* Öl</strong></td><td><strong>Tröpfchengröße (µm) mit FluoDrop 7500* Öl</strong></td></tr><tr><td>Flow-Focusing (DG-DM1-45)</td><td>20 → 79</td><td>21 → 93</td></tr><tr><td><a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-junction</a> (CS-10000176) Design 1</td><td>98 → 312</td><td>60 → 494</td></tr><tr><td><a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-junction</a> (CS-10000176) Design 2</td><td>18 → 70,002</td><td>12 → 70</td></tr><tr><td><a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-junction</a> (CS-10000176) Design 3</td><td>11 → 79</td><td>22 → 78</td></tr><tr><td><a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-junction</a> (CS-10000176) Design 4</td><td>94 → 484</td><td>96 → 387</td></tr><tr><td><a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-junction</a> (CS-10000176) Design 5</td><td>270 → 876</td><td>345 → 700</td></tr></tbody></table><p>*Die Viskosität von HFE beträgt 0,77 cSt und die Viskosität von FC40 beträgt 2,2 cSt</p><p>Gemäß der Publikation von Nekouei und Vanapalli (2017) zeigt die Interpretation dieser Ergebnisse, dass die Tröpfchengröße der erzeugten Tröpfchen umso kleiner ist, je höher die Viskosität der kontinuierlichen Phase ist.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>In dieser Übersicht untersuchen wir zwei der am häufigsten verwendeten Designs für die Tröpfchenerzeugung: <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-Junction</a> und Flow-Focusing. Zunächst besprechen wir, wie sich die Tröpfchengröße in der Mikrofluidik vorhersagen lässt. Anschließend stellen wir die Ergebnisse vor, die wir für… erzielt haben.</p>\n","protected":false},"author":3,"featured_media":14574,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[29,23],"tags":[],"class_list":["post-14570","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","category-droplet-generation"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Charakterisierung der Tröpfchengröße bei verschiedenen mikrofluidischen Konstruktionen</title>\n<meta name=\"description\" content=\"In diesem Übersichtsartikel untersuchen wir zwei der am häufigsten verwendeten Designs für die Tröpfchenerzeugung: T-Stück (T-Junction) und Flow-Focusing.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Charakterisierung der Tröpfchengröße bei verschiedenen mikrofluidischen Konstruktionen\">\n<meta property=\"og:description\" content=\"In diesem Übersichtsartikel untersuchen wir zwei der am häufigsten verwendeten Designs für die Tröpfchenerzeugung: T-Stück (T-Junction) und Flow-Focusing.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-23T14:10:30+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:13:18+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp\">\n\t<meta property=\"og:image:width\" content=\"640\">\n\t<meta property=\"og:image:height\" content=\"631\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"5 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Characterization of the droplet size for various microfluidic designs\",\"datePublished\":\"2023-02-23T14:10:30+00:00\",\"dateModified\":\"2026-11-19T14:13:18+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/\"},\"wordCount\":940,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp\",\"articleSection\":[\"Application notes\",\"Droplet generation\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/\",\"url\":\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/\",\"name\":\"Characterization of the droplet size for various microfluidic designs\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp\",\"datePublished\":\"2023-02-23T14:10:30+00:00\",\"dateModified\":\"2026-11-19T14:13:18+00:00\",\"description\":\"In diesem Übersichtsartikel untersuchen wir zwei der am häufigsten verwendeten Designs für die Tröpfchenerzeugung: T-Stück (T-Junction) und Flow-Focusing.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp\",\"width\":640,\"height\":631,\"caption\":\"Graph of the gamma distribution of droplets\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Characterization of the droplet size for various microfluidic designs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Unser Blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/de\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Characterization of the droplet size for various microfluidic designs","description":"In diesem Übersichtsartikel untersuchen wir zwei der am häufigsten verwendeten Designs für die Tröpfchenerzeugung: T-Stück (T-Junction) und Flow-Focusing.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/","og_locale":"en_US","og_type":"article","og_title":"Characterization of the droplet size for various microfluidic designs","og_description":"In this review, we explore two of the most used designs for droplet generation: T-junction and flow focusing.","og_url":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-23T14:10:30+00:00","article_modified_time":"2026-11-19T14:13:18+00:00","og_image":[{"width":640,"height":631,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"5 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Characterization of the droplet size for various microfluidic designs","datePublished":"2023-02-23T14:10:30+00:00","dateModified":"2026-11-19T14:13:18+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/"},"wordCount":940,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp","articleSection":["Application notes","Droplet generation"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/","url":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/","name":"Characterization of the droplet size for various microfluidic designs","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp","datePublished":"2023-02-23T14:10:30+00:00","dateModified":"2026-11-19T14:13:18+00:00","description":"In diesem Übersichtsartikel untersuchen wir zwei der am häufigsten verwendeten Designs für die Tröpfchenerzeugung: T-Stück (T-Junction) und Flow-Focusing.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp","width":640,"height":631,"caption":"Graph of the gamma distribution of droplets"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/characterization-of-the-droplet-size-for-various-microfluidic-designs/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Characterization of the droplet size for various microfluidic designs"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Unser Blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_gamma_distribution_describes_most_of_the_data_sets_well_extrated_from_Prileszky_et_al._2016-1.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14570","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14570"}],"version-history":[{"count":7,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14570/revisions"}],"predecessor-version":[{"id":15231,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14570/revisions/15231"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14574"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14570"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14570"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14570"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}