{"id":15987,"date":"2024-02-05T15:25:01","date_gmt":"2024-02-05T14:25:01","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=15987"},"modified":"2026-11-19T15:14:07","modified_gmt":"2026-11-19T14:14:07","slug":"choosing-the-right-materials-for-your-organ-on-a-chip-device","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","title":{"rendered":"Choosing the right materials for your organ-on-a-chip device"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"15987\" class=\"elementor elementor-15987\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-55eda1c3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"55eda1c3\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-433001d0\" data-id=\"433001d0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c2f8cea elementor-widget elementor-widget-text-editor\" data-id=\"c2f8cea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p></p>\n<p class=\"wp-block-paragraph\">In den letzten Jahren gab es bedeutende Entwicklungen bei<strong> <a href=\"https://darwin-microfluidics.com/de/collections/mikrofluidisches-organ-auf-einem-chip\">Organ-on-Chip (OoC)-</a></strong>Plattformen. Dennoch gibt es kein universelles „One-fits-all“-Modell und es wird angesichts der Vielfalt der Anwendungen, für die diese Vorrichtungen eingesetzt werden können, wahrscheinlich auch nie eines geben. Daher lohnt es sich, bei der Auswahl oder Entwicklung einer Organ-on-Chip-Plattform mehrere Schlüsselparameter zu berücksichtigen, um ein System zu erhalten, das optimal auf die zu beantwortende wissenschaftliche Fragestellung abgestimmt ist. </p>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\"> Wenn Sie mehr über Organ-on-Chip erfahren möchten, lesen Sie unseren Übersichtsartikel: <strong><a href=\"https://darwin-microfluidics.com/de/blogs/reviews/organ-on-a-chip-ein-allgemeiner-ueberblick\">Organ-On-Chip: a general overview</a></strong>. </p>\n<p></p>\n<p></p>\n<h2 class=\"wp-block-heading\">Design der Organ-On-Chip-Vorrichtung</h2>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">Die Konstruktion des „ Chip “ ist ein entscheidender Faktor, der bei der Entwicklung eines OoC-Modells berücksichtigt werden muss. Sie hängt von der jeweiligen Anwendung ab, für die das Gerät eingesetzt werden soll. Davon richten sich geometrische Parameter wie die Anzahl, Form und Abmessungen der Kanäle, die Anzahl der Ein- und Auslässe sowie das Vorhandensein von Kulturkammern, Anschlüssen oder sonstigen Elementen ab, die zur Durchführung der geplanten Studie erforderlich sind. Aus biologischer Sicht sollten während des Konstruktionsprozesses auch die Zellzahl, die Zelldichte und das Volumen der „ Flüssigkeit “ berücksichtigt werden. Eine korrekte Definition dieser Elemente trägt zu einer genauen physiologischen Modellierung des untersuchten Organs bzw. der untersuchten Zellen bei.</p>\n<p>Eine weitere sich bei der Implementierung eines OoC-Modells ergebende Frage ist die Notwendigkeit des Multiplexings – also mehrerer Designs auf einer einzigen Plattform –, was häufig das Format der Plattform vorgibt. Mehrere Replikate auf demselben Gerät zu haben, kann eine enorme Zeitersparnis bedeuten und insbesondere für Arzneimitteltests sogar notwendig sein.</p>\n<p>Das Design der Plattform sollte auch die Parameter berücksichtigen, die der Forscher mit der Plattform testen oder messen möchte. Einige für die Studie relevante Readouts können den Zugriff auf bestimmte Bereiche des Chips erfordern, um Analysen durchzuführen. Um beispielsweise einen spezifischen Biomarker zu identifizieren, kann es sinnvoll sein, im Laufe der Studie mehrmals Effluente sammeln zu können und daher einen speziellen Anschluss für die einfache Medienentnahme einzuplanen. Wenn am Ende des Experiments Analysen an den Zellen oder dem Gewebe durchgeführt werden müssen, ist es zudem wichtig, diese von der Plattform zurückgewinnen zu können.</p>\n<p>Schließlich können logistischere Parameter wie der Platzbedarf (Footprint), die Verwendung in einem Inkubator, die Flusszirkulation und andere Faktoren beeinflussen, wie die Plattform genutzt wird und wie sie dementsprechend designt sein muss.</p>\n<p></p>\n<p></p>\n<h2 class=\"wp-block-heading\">Wie wählt man das richtige Material für Ihre Organ-On-Chip-Vorrichtung aus?</h2>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">Die Wahl des Materials ist von großer Bedeutung, doch es ist nicht ganz einfach, ein Material zu finden, das alle Anforderungen des Experiments erfüllt, und bei dieser Auswahl müssen möglicherweise Kompromisse eingegangen werden. Zu den Parametern dieser Auswahl gehören natürlich die Biokompatibilität, aber auch die gewählte oder verfügbare Mikrofabrikationsstrategie, die Endpunkte, die das Modell erreichen muss, die Steifigkeit des Substrats, die Gasdurchlässigkeit, Überlegungen zur Massenproduktion und viele weitere Faktoren.</p>\n<p></p>\n<p></p>\n<h3 class=\"wp-block-heading\">Die wichtigsten Materialien für Organ-On-Chip-Vorrichtungen</h3>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">Derzeit gibt es kein absolut ideales Material für OoC-Vorrichtungen. Im Allgemeinen wird bevorzugt, dass das gewählte Material für Zellen nicht toxisch, gasdurchlässig und optisch beobachtbar ist. Es stehen verschiedene Materialoptionen zur Verfügung, die jeweils Vor- und Nachteile in Bezug auf physikalisch-chemische, biologische, wirtschaftliche oder praktische Parameter aufweisen.</p>\n<p></p>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">&nbsp;</p>\n<p></p>\n<p><!-- /wp:list --></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b11b3b elementor-widget elementor-widget-image\" data-id=\"5b11b3b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"447\" height=\"480\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\" class=\"attachment-large size-large wp-image-18533\" alt=\"Stoffverzeichnis für „Organ on a Chip“\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp 447w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480-279x300.webp 279w\" sizes=\"(max-width: 447px) 100vw, 447px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ead827 elementor-widget elementor-widget-text-editor\" data-id=\"7ead827\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"color: #252525; letter-spacing: -0.16px;\"><em>Nach Campbell et al., 2021 – Grün: gut, Gelb: mittel, Rot: schlecht</em></p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Das am häufigsten verwendete Material für mikrofluidische Chips und OoC ist <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://darwin-microfluidics.com/de/produkte/sylgard-184-pdms-elastomer\">PDMS</a></span> (Polydimethylsiloxan), vor allem aufgrund seiner einfachen Handhabung, des niedrigen Preises und der optischen Transparenz. Es weist zudem eine hohe Permeabilität auf, die sowohl ein Vor- als auch ein Nachteil sein kann. Während es eine ausreichende Sauerstoffversorgung der Zellkulturen ermöglicht, kann es auch den Metabolismus von Wirkstoffen oder die Produktion von Metaboliten durch Gewebe beeinträchtigen, wobei ein höheres Risiko besteht, dass kleine Zielmoleküle in der Polymermatrix absorbiert werden.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Andere häufig für die Chip-Herstellung verwendete Materialien sind <span style=\"font-weight: bolder;\">Thermoplaste.</span> Ihre geringen Kosten, die geringe <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">Absorption</a> und ihre optischen Transparenzeigenschaften sind wichtige Vorteile für die (Massen-)Produktion von OoC. Die Steifigkeit von Thermoplasten kann jedoch für die physiologische Modellierung problematisch sein. Im Körper kann die Gewebesteifigkeit bei Fettgewebe oder Gehirn auf einige wenige kPa absinken, verglichen mit den wenigen GPa gängiger Thermoplaste. Zudem kann es eine Herausforderung sein, bei der Arbeit mit Thermoplasten komplexe Geometrien zu erzeugen, was somit eine Einschränkung für das Chip-Design darstellen kann.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Ein weiteres Material, das für organe sur puce-Systeme verwendet wird, ist Glas. Es bietet den Vorteil einer hohen Transparenz, ist inert, biokompatibel und weist eine geringe Autofluoreszenz auf. Zudem lässt sich die Glasoberfläche leicht modifizieren, um die Zelladhäsion anzupassen. Dennoch sind Glassysteme wesentlich fragiler und teurer, und der Herstellungsprozess ist deutlich aufwendiger.</p>\n<h3 class=\"wp-block-heading\" style=\"font-family: Lato, sans-serif; letter-spacing: -0.16px;\">Materialsterilisation &amp; Oberflächenbehandlung</h3>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Sobald ein Material ausgewählt wurde, stellen sich Fragen hinsichtlich seiner Sterilisation oder Funktionalisierung.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Eine Sterilisation kann erforderlich sein, um mikrobielle Kontaminationen des Systems zu vermeiden, welche die durchgeführte Studie und deren Ergebnisse beeinträchtigen könnten. Es gibt zahlreiche Sterilisationsverfahren wie Autoklavieren, UV-Bestrahlung, Ethanolbehandlung, Gammabestrahlung oder Ethylenoxidbehandlung. Nicht alle dieser Methoden können mit den zuvor genannten Materialien angewendet werden. Während es beispielsweise unbedenklich ist, Polycarbonat (PC) zu autoklavieren, gilt dies möglicherweise nicht für PMMA. Daher ist es wichtig, die geeignete Sterilisationsmethode zu wählen, um eine Beschädigung des ausgewählten Materials zu verhindern.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Oberflächenbehandlung Dies kann aus mehreren Gründen auch ein notwendiger Schritt bei der Entwicklung von OoC-Geräten sein: zur Gewährleistung der Biokompatibilität sowie zur Förderung oder Verhinderung der Zelladhäsion. Auch hier stehen verschiedene Techniken zur Verfügung, um solche Funktionen zu erreichen, wobei die Kompatibilität sowohl mit dem Material „ Chip “ als auch mit den Zellen bzw. Geweben gewährleistet sein muss.</p>\n<h2 class=\"wp-block-heading\" style=\"font-family: Lato, sans-serif; letter-spacing: -0.16px;\">Referenzen:</h2>\n<ol style=\"letter-spacing: -0.16px;\">\n<li>Scott B. Campbell, Qinghua Wu, Joshua Yazbeck, Chuan Liu, Sargol Okhovatian und Milica Radisic – ACS Biomaterials Science & Engineering<span style=\"font-weight: bolder;\">2021</span>,<em>7</em>(7), 2880–2899 – DOI: <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://pubs.acs.org/doi/10.1021/acsbiomaterials.0c00640\">10.1021/acsbiomaterials.0c00640</a></span></li>\n<li>Toepke, Michael W., und David J. Beebe.<a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">„</a>PDMS <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\" data-wg-splitted>-Absorption</a> kleiner Moleküle und deren Auswirkungen auf mikrofluidische Anwendungen.“<em>Lab on a Chip</em>, Nov. 2006.<em>The Royal Society of Chemistry</em>, <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://doi.org/10.1039/b612140c\">https://doi.org/10.1039/b612140c</a></span></li>\n<li>Leung C.M., de Haan, P., Ronaldson-Bouchard, K. <em>et al.</em> A guide to the organ-on-a-chip. <em>Nat Rev Methods Primers</em> <span style=\"font-weight: bolder;\">2</span>, 33 (2022). <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://doi.org/10.1038/s43586-022-00118-6\">https://doi.org/10.1038/s43586-022-00118-6</a></span></li>\n<li>Yanping Wang, Yanfeng Gao, Yongchun Pan, Dongtao Zhou, Yuta Liu u. a., Neue Trends bei „Organ-on-a-Chip “-Systemen für das Wirkstoffscreening, Acta Pharmaceutica Sinica B, Band 13, Ausgabe 6, 2023, Seiten 2483–2509, ISSN 2211-3835, <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://doi.org/10.1016/j.apsb.2023.02.006\">https://doi.org/10.1016/j.apsb.2023.02.006</a></span>.</li>\n</ol>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ff60da elementor-widget elementor-widget-global elementor-global-18295 elementor-widget-pix-promo-box\" data-id=\"1ff60da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/17424049-optimized-DDI-Chip_blue2_2048x2048.webp\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"ORGANE SUR PUCE: DIE ZUKUNFT DER FORSCHUNG?\"><a href=\"https://darwin-microfluidics.com/de/collections/mikrofluidisches-organ-auf-einem-chip\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Entdecken Sie unsere Auswahl!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">ORGANE SUR PUCE: DIE ZUKUNFT DER FORSCHUNG?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Entdecken Sie unsere hochmodernen Lösungen für fortgeschrittene Forschung und Entwicklung!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>In den letzten Jahren hat es bedeutende Entwicklungen bei Organ-on-Chip-Plattformen (OoC) gegeben. Dennoch gibt es kein „One-Fits-All“-Modell, und angesichts der Vielfalt der Anwendungen, für die diese Geräte eingesetzt werden können, wird es das vermutlich auch nie geben. Daher ist es…</p>\n","protected":false},"author":3,"featured_media":18533,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[27,67],"tags":[],"class_list":["post-15987","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-comparisons"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Auswahl der richtigen Materialien für Ihr Organ-on-a-Chip-Gerät</title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Auswahl der richtigen Materialien für Ihr Organ-on-a-Chip-Gerät\">\n<meta property=\"og:description\" content=\"In den letzten Jahren hat es bedeutende Entwicklungen bei Organ-on-a-Chip-Plattformen (OoC) gegeben. Es gibt jedoch kein universelles Standardmodell – und angesichts der Vielfalt der Anwendungen, für die diese Systeme eingesetzt werden können, wird es das vermutlich auch nie geben. Daher ist es...\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-02-05T14:25:01+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:14:07+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\">\n\t<meta property=\"og:image:width\" content=\"447\">\n\t<meta property=\"og:image:height\" content=\"480\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"5 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Choosing the right materials for your organ-on-a-chip device\",\"datePublished\":\"2024-02-05T14:25:01+00:00\",\"dateModified\":\"2026-11-19T14:14:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\"},\"wordCount\":1049,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Comparisons &amp; buying guides\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\",\"url\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\",\"name\":\"Choosing the right materials for your organ-on-a-chip device\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"datePublished\":\"2024-02-05T14:25:01+00:00\",\"dateModified\":\"2026-11-19T14:14:07+00:00\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"width\":447,\"height\":480,\"caption\":\"table of materials for organ on chips\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Choosing the right materials for your organ-on-a-chip device\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Unser Blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/de\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Choosing the right materials for your organ-on-a-chip device","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","og_locale":"en_US","og_type":"article","og_title":"Choosing the right materials for your organ-on-a-chip device","og_description":"Over the last few years, there have been major developments in organ-on-chip (OoC) platforms. Yet, there is no &lsquo;one-fits-all&rsquo; model, and probably will never be considering the variety of applications for which those devices can be used. Thus, it is...","og_url":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-02-05T14:25:01+00:00","article_modified_time":"2026-11-19T14:14:07+00:00","og_image":[{"width":447,"height":480,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"5 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Choosing the right materials for your organ-on-a-chip device","datePublished":"2024-02-05T14:25:01+00:00","dateModified":"2026-11-19T14:14:07+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/"},"wordCount":1049,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","articleSection":["Cell culture &amp; organ-on-chip","Comparisons &amp; buying guides"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","url":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","name":"Choosing the right materials for your organ-on-a-chip device","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","datePublished":"2024-02-05T14:25:01+00:00","dateModified":"2026-11-19T14:14:07+00:00","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","width":447,"height":480,"caption":"table of materials for organ on chips"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Choosing the right materials for your organ-on-a-chip device"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Unser Blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/15987","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=15987"}],"version-history":[{"count":8,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/15987/revisions"}],"predecessor-version":[{"id":19548,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/15987/revisions/19548"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/18533"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=15987"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=15987"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=15987"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}