{"id":21476,"date":"2024-03-06T16:33:33","date_gmt":"2024-03-06T15:33:33","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=21476"},"modified":"2026-11-19T15:14:31","modified_gmt":"2026-11-19T14:14:31","slug":"how-to-control-the-longer-wt600-2j-pump-via-python","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/","title":{"rendered":"How to Control the Longer WT600-2J(1J)(3J) Pump via Python ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"21476\" class=\"elementor elementor-21476\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f68e333 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f68e333\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a2269f8\" data-id=\"a2269f8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9d4d519 elementor-widget elementor-widget-text-editor\" data-id=\"9d4d519\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn Sie nach einer leistungsstarken <strong>Schlauchpumpe</strong> für Labor- und Industrieanwendungen suchen, sollten Sie sich die <strong>Longer <a href=\"https://darwin-microfluidics.com/de/produkte/wt600-2j-basis-schlauchpumpe?variant=43790678196459\" target=\"_blank\" rel=\"noopener\">WT600-2J</a></strong> ansehen. Diese Pumpe liefert Flussraten zwischen 4,2 mL/min und 6000 mL/min. Sie verfügt über einen wartungsfreien, bürstenlosen Motor mit hohem Drehmoment, der die Montage von bis zu 4 Pumpenköpfen auf demselben drive ermöglicht.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5c76d2c elementor-widget elementor-widget-text-editor\" data-id=\"5c76d2c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Der WT600-2J lässt sich von Ihrem Computer aus fernsteuern, was Ihnen mehr Flexibilität und Komfort bietet, insbesondere wenn Sie komplexe Pumpenprogramme mit Schleifen, Pausen und unterschiedlichen Drehzahlen ausführen möchten.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eaa45a5 elementor-widget elementor-widget-text-editor\" data-id=\"eaa45a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In diesem Blogbeitrag zeigen wir Ihnen, wie Sie mit dem WT600-2J über das <strong>LONGER RS485-Protokoll</strong> kommunizieren. Hierbei handelt es sich um ein serielles Kommunikationsprotokoll, mit dem Sie Befehle an die Pumpe senden und Antworten von ihr empfangen können. Wir stellen Ihnen außerdem einige Beispiele und <a href=\"#code\">Codeausschnitte</a> zur Verfügung, wie Sie <strong>Python</strong> verwenden, um Steuerbefehlsketten an die Pumpe zu schreiben und zu senden.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1857e26 elementor-toc--content-ellipsis elementor-toc--minimized-on-tablet elementor-widget elementor-widget-table-of-contents\" data-id=\"1857e26\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;exclude_headings_by_selector&quot;:&quot;#cta1, #cta2&quot;,&quot;headings_by_tags&quot;:[&quot;h2&quot;,&quot;h3&quot;],&quot;marker_view&quot;:&quot;numbers&quot;,&quot;no_headings_message&quot;:&quot;No headings were found on this page.&quot;,&quot;minimize_box&quot;:&quot;yes&quot;,&quot;minimized_on&quot;:&quot;tablet&quot;,&quot;hierarchical_view&quot;:&quot;yes&quot;,&quot;min_height&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_tablet&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]},&quot;min_height_mobile&quot;:{&quot;unit&quot;:&quot;px&quot;,&quot;size&quot;:&quot;&quot;,&quot;sizes&quot;:[]}}\" data-widget_type=\"table-of-contents.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__header\">\n\t\t\t\t\t\t<h4 class=\"elementor-toc__header-title\">\n\t\t\t\tINHALTSVERZEICHNIS\t\t\t</h4>\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--expand\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__1857e26\" aria-expanded=\"true\" aria-label=\"Open table of contents\"><i aria-hidden=\"true\" class=\"fas fa-chevron-down\"></i></div>\n\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--collapse\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__1857e26\" aria-expanded=\"true\" aria-label=\"Close table of contents\"><i aria-hidden=\"true\" class=\"fas fa-chevron-up\"></i></div>\n\t\t\t\t\t</div>\n\t\t\t\t<div id=\"elementor-toc__1857e26\" class=\"elementor-toc__body\">\n\t\t\t<div class=\"elementor-toc__spinner-container\">\n\t\t\t\t<i class=\"elementor-toc__spinner eicon-animation-spin eicon-loading\" aria-hidden=\"true\"></i>\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0365ac4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0365ac4\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-980534a\" data-id=\"980534a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-193ff50 elementor-widget elementor-widget-heading\" data-id=\"193ff50\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was wird für die Kommunikation mit dem WT600-2J benötigt?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d743e1 elementor-widget elementor-widget-text-editor\" data-id=\"8d743e1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Um über das LONGER-RS485-Protokoll mit dem WT600-2J zu kommunizieren, benötigen Sie Folgendes:</p><ul><li>Eine WT600-2J Pumpe mit einem <a href=\"https://darwin-microfluidics.com/de/collections/schlauchpumpe-pumpenkopf\">Pumpenkopf</a> und einem <a href=\"https://darwin-microfluidics.com/de/collections/schlauchpumpe-schlauche\">tube</a> Ihrer Wahl</li><li>Ein RS485-<a href=\"https://darwin-microfluidics.com/de/collections/schlauchpumpe-zubehor/produkte/externes-steuerung-modul-fur-longer-pumpen\">Steuermodul</a>, das in den DB15-Anschluss an der Rückseite der Pumpe eingesteckt wird</li><li>Ein <a href=\"https://darwin-microfluidics.com/de/produkte/usb-zu-rs485-seriell-konverter-kabel/\">serielles Kabel</a>, das das RS485-Steuermodul mit Ihrem Computer oder Gerät verbindet</li><li>Eine Programmierplattform (in diesem Fall Python)</li><li>Grundlegende Kenntnisse über das Daten-, Befehls- und PDU-Format des LONGER RS485-Protokolls (wird unten <a href=\"#pdu\">👇</a> erläutert)</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-011b1f2 elementor-widget elementor-widget-global elementor-global-18316 elementor-widget-pix-promo-box\" data-id=\"011b1f2\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta1\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Tubing_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"SUCHEN SIE NACH FLEXIBLEN OPTIONEN FÜR „ Schläuche “?\"><a href=\"https://darwin-microfluidics.com/de/collections/microfluidic-schlauche\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Entdecken Sie unsere Auswahl!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">SUCHEN SIE NACH FLEXIBLEN OPTIONEN FÜR „ Schläuche “?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Entdecken Sie unsere mikrofluidischen tube-Lösungen für einen zuverlässigen und effizienten Durchfluss in Ihren Experimenten!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-27c903d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"27c903d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-64b2531\" data-id=\"64b2531\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8ae13f9 elementor-widget elementor-widget-heading\" data-id=\"8ae13f9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie richtet man den Kommunikationsport ein?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a7eb929 elementor-widget elementor-widget-text-editor\" data-id=\"a7eb929\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bevor Sie Daten an die Pumpe senden und von ihr empfangen können, müssen Sie den Kommunikationsport korrekt einrichten. Hier sind die zu befolgenden Schritte:\n</p><ul>\n \t<li>Schließen Sie den DB15-Stecker an den DB15-Anschluss an der Rückseite der Pumpe an.</li>\n \t<li>Schalten Sie die Pumpe ein</li>\n \t<li>Stellen Sie sicher, dass die Kommunikationsparameter auf Ihrer Programmierplattform mit denen des WT600-2J übereinstimmen. Diese lauten:\n<ul>\n \t<li>1 Startbit</li>\n \t<li><span style=\"font-weight: 400;\">8 Datenbits</span></li>\n \t<li><span style=\"font-weight: 400;\">1 Even Parity (gerade Parität)</span></li>\n \t<li><span style=\"font-weight: 400;\">1 Stoppbit</span></li>\n \t<li><span style=\"font-weight: 400;\">eine Baudrate von 1200 Baud</span></li>\n</ul>\n</li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-8d920d2 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"8d920d2\" data-element_type=\"section\" data-e-type=\"section\" id=\"pdu\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ba8b271\" data-id=\"ba8b271\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-cdab93f elementor-widget elementor-widget-heading\" data-id=\"cdab93f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie schreibt man Steuerbefehlsketten für den WT600-2J?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-289518b elementor-widget elementor-widget-text-editor\" data-id=\"289518b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Sobald der Kommunikationsport eingerichtet ist, können Sie damit beginnen, Steuerbefehlsketten zu schreiben und an die Pumpe zu senden. Eine Steuerbefehlskette ist eine Sequenz von Hexadezimalzeichen, die einem spezifischen Format folgt und sich aus folgenden Elementen zusammensetzt:\n</p><ul>\n \t<li>einem Start-Flag (E9H)</li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">einer Pumpenadresse (1 bis 30 oder 31 für Broadcast)</span></li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">einer Länge der PDU (Protocol Data Unit)</span></li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">einer PDU, die die Befehlszeichen und Parameter für die gewünschte Anwendung enthält</span></li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">einer Frame Check Sequence (FCS), die durch die Berechnung der XOR-Verknüpfung aus Pumpenadresse, PDU-Länge und der PDU selbst ermittelt wird </span>(berechnen Sie Ihre FCS mit unserem Online-<a href=\"https://blog.darwin-microfluidics.com/frame-check-sequence-xor-calculator-for-longer-pump-control/\">Frame Check Sequence XOR-Rechner</a>)</li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0e9988 elementor-widget elementor-widget-text-editor\" data-id=\"a0e9988\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die PDU und ihre Länge hängen von der jeweiligen Anwendung der Pumpe ab. Zu den gängigen Anwendungen gehören:\n</p><ul>\n \t<li>Einstellen der Betriebsparameter (Drehzahl)</li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Auslesen der Betriebsparameter (Drehzahl)</span></li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Pumpenadresse schreiben</span></li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Pumpenadresse lesen</span></li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-15fa493 elementor-widget elementor-widget-text-editor\" data-id=\"15fa493\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Für jede Anwendung gibt es einen entsprechenden Satz von Befehlszeichen und Parametern, den Sie in die PDU einbinden müssen. Diese Parameter werden nachfolgend im Detail erläutert.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1d01615 elementor-widget elementor-widget-heading\" data-id=\"1d01615\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Einstellen der Betriebsparameter (Drehzahl)</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9003233 elementor-widget elementor-widget-text-editor\" data-id=\"9003233\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diese Anwendung besteht aus Schreibvorgängen an die Pumpe. Die Gesamtlänge der PDU beträgt <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">6 Byte</span>, wobei sich die Steuerbefehlskette aus folgenden Elementen zusammensetzt (in exakt dieser Reihenfolge):</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e08374d elementor-widget elementor-widget-shortcode\" data-id=\"e08374d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-14\" class=\"tablepress tablepress-id-14\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">WJ</td><td class=\"column-2\">Drehzahl einstellen</td><td class=\"column-3\">Status 1</td><td class=\"column-4\">Status 2</td>\n</tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">2 Byte</td><td class=\"column-2\">2 Byte</td><td class=\"column-3\">1 Byte</td><td class=\"column-4\">1 Byte</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-14 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-37125a8 elementor-widget elementor-widget-text-editor\" data-id=\"37125a8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>WJ, Steuerbefehlskette von <span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 Bytes</span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">, 57 4A</span></li>\n \t<li>Drehzahl einstellen (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 Bytes</span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">) mit einer Höchstgeschwindigkeit von 600 U/min (02 58)</span></li>\n \t<li>Status 1 (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 Byte</span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">): </span>\n<ul>\n \t<li dir=\"ltr\" style=\"line-height: 1.38;\" role=\"presentation\"><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">Bit 0 – Start/Stopp-Bit, wobei 1 die Pumpe startet und 0 sie stoppt</span></li>\n \t<li dir=\"ltr\" style=\"line-height: 1.38;\" role=\"presentation\"><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">Bit 1 – Ansaug-Bit (Prime Bit), wobei 1 bedeutet, dass die Pumpe mit der Höchstgeschwindigkeit von 600 U/min angeregt wird, und 0 bedeutet, dass die Pumpe mit normaler Geschwindigkeit läuft</span></li>\n</ul>\n</li>\n \t<li>Status 2 (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 Byte</span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">):</span>\n<ul>\n \t<li dir=\"ltr\" style=\"line-height: 1.38;\" role=\"presentation\">Bit 0 – legt die <span style=\"letter-spacing: -0.16px;\">Drehrichtung</span> fest, wobei 1 für den Uhrzeigersinn und 0 für den entgegengesetzten Uhrzeigersinn steht</li>\n</ul>\n</li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ed3ef9 elementor-widget elementor-widget-text-editor\" data-id=\"1ed3ef9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Pumpe antwortet mit <span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">WJ</span></span> und zeigt nach dem Empfang der Steuerbefehlszeichenfolge die Drehzahl auf ihrem Frontdisplay an.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa2e7da elementor-widget elementor-widget-heading\" data-id=\"fa2e7da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Auslesen der Betriebsparameter (Drehzahl)</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8f5604d elementor-widget elementor-widget-text-editor\" data-id=\"8f5604d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diese Anwendung besteht aus dem Auslesen der Pumpe. Die Gesamtlänge der PDU beträgt <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">2 Bytes</span>, wobei der SteuerungBefehlsstring <span style=\"font-size: 12pt; font-family: Arial, sans-serif; vertical-align: baseline; white-space-collapse: preserve; background-color: #cccccc;\"><span style=\"color: #111111;\">RJ</span></span> lautet.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5f85c05 elementor-widget elementor-widget-text-editor\" data-id=\"5f85c05\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Reaktion der Pumpe umfasst: </p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b4c10cc elementor-widget elementor-widget-shortcode\" data-id=\"b4c10cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-15\" class=\"tablepress tablepress-id-15\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">RJ</td><td class=\"column-2\">Drehzahl anzeigen</td><td class=\"column-3\">Status 1</td><td class=\"column-4\">Status 2</td>\n</tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">2 Byte</td><td class=\"column-2\">2 Byte</td><td class=\"column-3\">1 Byte</td><td class=\"column-4\">1 Byte</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-15 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3fd2ffa elementor-widget elementor-widget-text-editor\" data-id=\"3fd2ffa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>RJ, Steuerbefehlsstring von <span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 Bytes</span>, 52 4A</li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a142365 elementor-widget elementor-widget-heading\" data-id=\"a142365\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Pumpenadresse schreiben</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0290e13 elementor-widget elementor-widget-text-editor\" data-id=\"0290e13\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diese Anwendung dient zum Schreiben an die Pumpe. Die Gesamtlänge der PDU beträgt <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">4 Byte</span>, wobei die Steuerbefehlszeichenfolge wie folgt aufgebaut ist:</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d16a9ce elementor-widget-mobile__width-auto elementor-widget elementor-widget-shortcode\" data-id=\"d16a9ce\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-22\" class=\"tablepress tablepress-id-22\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">WID</td><td class=\"column-2\">Neue Pumpen-ID.</td>\n</tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">3 Bytes</td><td class=\"column-2\">1 Byte</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-22 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7163ff4 elementor-widget elementor-widget-text-editor\" data-id=\"7163ff4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li dir=\"ltr\" style=\"line-height: 1.38;\" role=\"presentation\"><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">WID, Steuerbefehlsstring von </span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">3 Bytes</span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">, 57 49 44</span></li><li dir=\"ltr\" style=\"line-height: 1.38;\" role=\"presentation\"><span style=\"font-weight: 400;\">Neue Pumpenadresse (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 Byte</span></span><span style=\"font-weight: 400;\">), kann die Pumpenadresse (1–30) oder die Broadcast-Adresse (31) sein; die Standard-Pumpenadresse ist 1</span></li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-00d0d34 elementor-widget elementor-widget-text-editor\" data-id=\"00d0d34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Pumpe antwortet mit <span style=\"font-size: 12pt; font-family: Arial, sans-serif; vertical-align: baseline;\"><span style=\"color: #111111;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">WID</span></span></span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\"><span style=\"font-weight: 400;\">.</span></span></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-58eff25 elementor-widget elementor-widget-heading\" data-id=\"58eff25\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Pumpenadresse auslesen</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9dfbf38 elementor-widget elementor-widget-text-editor\" data-id=\"9dfbf38\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diese Anwendung dient zum Auslesen von Daten aus der Pumpe. Die Gesamtlänge der PDU beträgt <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">3 Byte</span>, wobei die Steuerbefehlszeichenfolge <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\"><span style=\"color: #111111; letter-spacing: -0.16px; white-space-collapse: preserve; background-color: #cccccc;\">„RID“</span></span> lautet <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\" data-wg-splitted>.</span></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c721180 elementor-widget elementor-widget-text-editor\" data-id=\"c721180\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn in einem Befehlsstring vom Steuerungscomputer die Adresse einer einzelnen Pumpenadresse (1–30) und nicht der Broadcast-Adresse (31) entspricht, antwortet die entsprechende Pumpe mit <span style=\"font-size: 1rem; letter-spacing: -0.16px; font-family: Arial, sans-serif; white-space-collapse: preserve; color: #111111; background-color: #cccccc;\">RID</span><span style=\"font-size: 1rem; letter-spacing: -0.16px; color: #000000; font-family: Arial, sans-serif;\">.</span></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2aa954e elementor-widget elementor-widget-heading\" data-id=\"2aa954e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Beispiele für Steuerbefehlsketten</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5014337 elementor-widget elementor-widget-text-editor\" data-id=\"5014337\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Den WT600-2J so einstellen, dass er im Uhrzeigersinn mit einer Drehzahl von 150 rpm läuft</strong></li></ul><p><span style=\"font-weight: 400;\">Steuerbefehlsstring: </span><span style=\"background-color: #cccccc; color: #000000; font-family: Arial, sans-serif; font-size: 12pt; white-space-collapse: preserve; letter-spacing: -0.01rem;\">E9 01 06 57 4A 00 96 01 01 8C</span></p><ul><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">E9</span> als Flag</span></li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01</span> als Pumpenadresse 1</span></li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">06</span> als Länge der PDU (<span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">57 4A 00 96 01 01</span></span></span><span style=\"font-weight: 400;\">)</span></li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">57 4A</span></span> als Befehlszeichen WJ</span></li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">00 96</span> bezieht sich auf die Drehzahl, 0096(hex) = 150(dec) </span>(nutzen Sie unser Online-<a style=\"background-color: #ffffff; font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: 400; letter-spacing: -0.16px;\" href=\"https://blog.darwin-microfluidics.com/base-converter-binary-octal-decimal-and-hexadecimal/\">Basiskonvertierungstool</a><span style=\"letter-spacing: -0.16px;\">)</span></li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01</span> um die Pumpe mit normaler Geschwindigkeit zu starten</span></li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01</span> um die Pumpe im Uhrzeigersinn laufen zu lassen</span></li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">8C</span></span> als XOR-Ergebnis aus </span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01</span> (Pumpenadresse), </span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">06</span> (PDU-Länge) und </span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">57 4A 00 96 01 01</span> (PDU) </li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ba09f38 elementor-widget elementor-widget-text-editor\" data-id=\"ba09f38\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Die Adresse des WT600-2J (ursprünglich 1) auf Adresse 7 setzen</strong></li></ul><p><span style=\"font-weight: 400;\">Steuerbefehlsstring: </span><span style=\"background-color: #cccccc; color: #000000; font-family: Arial, sans-serif; font-size: 12pt; white-space-collapse: preserve; letter-spacing: -0.01rem;\">E9 01 04 57 49 44 07 58</span></p><ul><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">E9</span> als Flag</span></li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">01</span></span> als initiale Pumpenadresse 1</span></li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">04</span></span> als Länge der PDU (</span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">57 49 44 07</span>)</span></li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">57 49 44</span></span> als Befehlszeichen WID</span></li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">07</span> als neue Pumpenadresse</span></li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">58</span></span> als XOR-Ergebnis aus </span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01</span> (Pumpenadresse), </span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">04</span> (PDU-Länge) und </span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">57 49 44 07</span> (PDU) </li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-57447d6 elementor-widget elementor-widget-text-editor\" data-id=\"57447d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em><strong>🚨</strong><strong>Nutzen Sie unseren benutzerfreundlichen Online-<a href=\"https://blog.darwin-microfluidics.com/control-command-string-generator-for-longer-peristaltic-pumps/\">Befehlsstring-Generator</a>, um mühelos präzise Steuerbefehlsstrings für Ihren WT600-2J zu erstellen.</strong></em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5072f3a elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5072f3a\" data-element_type=\"section\" data-e-type=\"section\" id=\"code\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0700aab\" data-id=\"0700aab\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e805577 elementor-widget elementor-widget-heading\" data-id=\"e805577\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie kommuniziert man mit dem WT600-2J über Python?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b25558 elementor-widget elementor-widget-text-editor\" data-id=\"2b25558\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nachfolgend werden Python-Code-Snippets vorgestellt, die zeigen, wie man die serielle Schnittstelle öffnet, Steuerbefehlsstrings an die Pumpe schreibt und sendet und ein einfaches Pumpprogramm schreibt.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b57068e elementor-widget elementor-widget-text-editor\" data-id=\"b57068e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Basierend auf dem gerade vorgestellten ersten Beispiel lässt der folgende Python-Code den WT600-2J im Uhrzeigersinn mit einer Drehzahl von 150 rpm laufen.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7dd333c elementor-widget elementor-widget-code-highlight\" data-id=\"7dd333c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"code-highlight.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"prismjs-tomorrow copy-to-clipboard word-wrap\">\n\t\t\t<pre data-line=\"4,7,10,13\" class=\"highlight-height language-python line-numbers\">\n\t\t\t\t<code readonly=\"\" class=\"language-python\">\n\t\t\t\t\t<xmp>### PUMPE 1 IM UHRZEIGERSINN MIT EINER DREHZAHL VON 150 U/min BETREIBEN\r\n\r\n# Zur Verwendung des pySerial-Pakets\r\nimport serial\r\n\r\n# Öffnen Sie die serielle Schnitt Port , mit dem für das WT600-2J entsprechenden Datenformat\r\nser = serial.Serial('COM6', 1200, parity=serial.PARITY_EVEN, bytesize=8, stopbits=1, timeout=None, xonxoff=0, rtscts=0)\r\n\r\n# Die entsprechende Steuerbefehlszeichenfolge in Hexadezimal schreiben\r\nData = bytearray(b'\\xE9\\x01\\x06\\x57\\x4A\\x00\\x96\\x01\\x01\\x8C')\r\n\r\n# Die Daten an die Pumpe schreiben\r\nser.write(Data)\r\n</xmp>\n\t\t\t\t</code>\n\t\t\t</pre>\n\t\t</div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fcf2ca6 elementor-widget elementor-widget-text-editor\" data-id=\"fcf2ca6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>Lassen Sie uns in einem zweiten Code-Snippet die Pumpe (Adresse 4) für 10 s im Uhrzeigersinn mit einer Drehzahl von 320 rpm laufen, sie dann für 30 s gegen den Uhrzeigersinn mit 50 rpm betreiben und schließlich stoppen.</li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa9154f elementor-widget elementor-widget-code-highlight\" data-id=\"fa9154f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"code-highlight.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"prismjs-tomorrow copy-to-clipboard word-wrap\">\n\t\t\t<pre data-line=\"\" class=\"highlight-height language-python line-numbers\">\n\t\t\t\t<code readonly=\"\" class=\"language-python\">\n\t\t\t\t\t<xmp>### LASS DIE PUMPE 4 10 Sekunden lang mit einer Drehzahl von 320 U/min im Uhrzeigersinn laufen, anschließend 30 Sekunden lang mit einer Drehzahl von 50 U/min gegen den Uhrzeigersinn, bevor du sie anhältst.\n\n# Zur Verwendung des pySerial-Pakets\nimport serial\r\n# Zur Verwendung des „time“-Pakets\r\nimport time\r\n# Öffnen Sie die serielle Schnitt Port ie mit dem für den WT600-2J entsprechenden Datenformat\r\nser = serial.Serial(&#039;COM6&#039;, 1200, parity=serial.PARITY_EVEN, bytesize=8, stopbits=1, timeout=None, xonxoff=0, rtscts=0)\r\n\r\n# Pumpe 4 10 Sekunden lang mit einer Drehzahl von 320 U/min im Uhrzeigersinn laufen lassen\r\nData = bytearray(b&#039;\\xE9\\x04\\x06\\x57\\x4A\\x01\\x40\\x01\\x01\\x5E&#039;) # entsprechende Steuerbefehlszeichenfolge in Hexadezimal; 320 (dez.) = 01 40 (hex.)\r\n\r\nser.write(Data) # Die Daten an die Pumpe schreiben\r\n\r\nPumping_time = 10;\nwhile Pumping_time &gt; 0:\n    print(Pumping_time)\n    time.sleep(1)\n    Pumping_time = Pumping_time - 1\nend # 10 s Verzögerung mit sichtbarem Timer\n\n# Pumpe 4 30 s lang mit einer Drehzahl von 50 U/min gegen den Uhrzeigersinn laufen lassen\r\nData = bytearray(b&#039;\\xE9\\x04\\x06\\x57\\x4A\\x00\\x32\\x01\\x00\\x2C&#039;) # entsprechende Steuerbefehlszeichenfolge in Hexadezimal; 50 (dez.) = 00 32 (hex.)\r\n\r\nser.write(Data) # Die Daten an die Pumpe schreiben\r\n\r\nPumping_time = 30;\nwhile Pumping_time &gt; 0:\n    print(Pumping_time)\n    time.sleep(1)\n    Pumping_time = Pumping_time - 1\nend # 30s Verzögerung mit sichtbarem Timer\r\n\r\n# Pumpe stoppen\\n\\nData = bytearray(b&#039;\\xE9\\x04\\x06\\x57\\x4A\\x00\\x32\\x00\\x00\\x2D&#039;) # entsprechende Steuerbefehlszeichenfolge in Hexadezimal: Wir haben die vorherige Befehlszeichenfolge genommen und das „State 1“-Byte von 01 (Pumpe starten) auf 00 (Pumpe stoppen) geändert und natürlich den neuen fcs berechnet\r\n\r\nser.write(Data) # Die Daten an die Pumpe schreiben\r\n</xmp>\n\t\t\t\t</code>\n\t\t\t</pre>\n\t\t</div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ee3aee2 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ee3aee2\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-be93118\" data-id=\"be93118\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-846ac9a elementor-widget elementor-widget-heading\" data-id=\"846ac9a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fazit</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8dda416 elementor-widget elementor-widget-text-editor\" data-id=\"8dda416\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wir hoffen, dass dieser Blogbeitrag Ihnen dabei geholfen hat, zu verstehen, wie Sie die Pumpe „ Longer “ WT600-2J Mehrkanal Schlauchpumpe  mithilfe des LONGER-RS485-Protokolls per Python fernsteuern können. Sie können auch andere Programmierplattformen wie Matlab verwenden, um Steuerbefehlszeichenfolgen zu erstellen und an die Pumpe zu senden sowie die Antworten der Pumpe auszulesen und zu interpretieren. Weitere Informationen zu diesem Thema finden Sie in unserem Blogbeitrag „<a href=\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-matlab/\"><b>Wie lässt sich die Longer WT600-2J(1J)(3J)-Pumpe über Matlab steuern?</b></a><span style=\"font-weight: 400;\">“.</span></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a99f514 elementor-widget elementor-widget-text-editor\" data-id=\"a99f514\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn Sie Fragen oder Feedback haben, können Sie uns gerne kontaktieren unter <a href=\"https://darwin-microfluidics.com/de/pages/kontakt\"><span style=\"font-weight: 400;\">contact@darwin-microfluidics.com</span></a><span style=\"font-weight: 400;\">.</span></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3db329b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3db329b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-61f1482\" data-id=\"61f1482\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8a33dfa elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"8a33dfa\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Brauchen Sie Hilfe bei Ihrem Mikrofluidik-Projekt?\"><a href=\"https://darwin-microfluidics.com/de/kontakt\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Kontaktieren Sie unsere Experten!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Brauchen Sie Hilfe bei Ihrem Mikrofluidik-Projekt?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Wir machen Mikrofluidik einfach für Sie!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Wenn Sie nach einer leistungsstarken Schlauchpumpe für Labor- und Industrieanwendungen suchen, ist die Longer WT600-2J eine hervorragende Wahl. Diese Pumpe bietet Förderraten zwischen 4,2 ml/min und 6000 ml/min. Sie verfügt über eine...</p>\n","protected":false},"author":4,"featured_media":21340,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[24,33],"tags":[],"class_list":["post-21476","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-control","category-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Wie lässt sich die Pumpe „ Longer “ WT600-2J(1J)(3J) über Python steuern?</title>\n<meta name=\"description\" content=\"Verwenden Sie Python, um über RS485 eine Fernkommunikation mit der Pumpe „ Longer “ WT600-2J herzustellen. Erfahren Sie, wie Sie Steuerbefehlszeichenfolgen schreiben und an die Pumpe senden.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Wie lässt sich die Pumpe „ Longer “ WT600-2J(1J)(3J) über Python steuern?\">\n<meta property=\"og:description\" content=\"Verwenden Sie Python, um über RS485 eine Fernkommunikation mit der Pumpe „ Longer “ WT600-2J herzustellen. Erfahren Sie, wie Sie Steuerbefehlszeichenfolgen schreiben und an die Pumpe senden.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-03-06T15:33:33+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:14:31+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/WT600-2J.png\">\n\t<meta property=\"og:image:width\" content=\"987\">\n\t<meta property=\"og:image:height\" content=\"948\">\n\t<meta property=\"og:image:type\" content=\"image/png\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"7 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"How to Control the Longer WT600-2J(1J)(3J) Pump via Python ?\",\"datePublished\":\"2024-03-06T15:33:33+00:00\",\"dateModified\":\"2026-11-19T14:14:31+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/\"},\"wordCount\":1216,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/WT600-2J.png\",\"articleSection\":[\"Flow control\",\"Guides &amp; tutorials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/\",\"url\":\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/\",\"name\":\"How to Control the Longer WT600-2J(1J)(3J) Pump via Python ?\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/WT600-2J.png\",\"datePublished\":\"2024-03-06T15:33:33+00:00\",\"dateModified\":\"2026-11-19T14:14:31+00:00\",\"description\":\"Verwenden Sie Python, um über RS485 eine Fernkommunikation mit der Pumpe „ Longer “ WT600-2J herzustellen. Erfahren Sie, wie Sie Steuerbefehlszeichenfolgen schreiben und an die Pumpe senden.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/WT600-2J.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/WT600-2J.png\",\"width\":987,\"height\":948,\"caption\":\"An image of a Longer WT600-2J peristaltic pump without background\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Control the Longer WT600-2J(1J)(3J) Pump via Python ?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Unser Blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/de\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Control the Longer WT600-2J(1J)(3J) Pump via Python ?","description":"Verwenden Sie Python, um über RS485 eine Fernkommunikation mit der Pumpe „ Longer “ WT600-2J herzustellen. Erfahren Sie, wie Sie Steuerbefehlszeichenfolgen schreiben und an die Pumpe senden.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/","og_locale":"en_US","og_type":"article","og_title":"How to Control the Longer WT600-2J(1J)(3J) Pump via Python ?","og_description":"Use Python to communicate remotely with the Longer WT600-2J pump via RS485. Learn how to write and send control command strings to the pump.","og_url":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-03-06T15:33:33+00:00","article_modified_time":"2026-11-19T14:14:31+00:00","og_image":[{"width":987,"height":948,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/WT600-2J.png","type":"image/png"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"7 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"How to Control the Longer WT600-2J(1J)(3J) Pump via Python ?","datePublished":"2024-03-06T15:33:33+00:00","dateModified":"2026-11-19T14:14:31+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/"},"wordCount":1216,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/WT600-2J.png","articleSection":["Flow control","Guides &amp; tutorials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/","url":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/","name":"How to Control the Longer WT600-2J(1J)(3J) Pump via Python ?","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/WT600-2J.png","datePublished":"2024-03-06T15:33:33+00:00","dateModified":"2026-11-19T14:14:31+00:00","description":"Verwenden Sie Python, um über RS485 eine Fernkommunikation mit der Pumpe „ Longer “ WT600-2J herzustellen. Erfahren Sie, wie Sie Steuerbefehlszeichenfolgen schreiben und an die Pumpe senden.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/WT600-2J.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/WT600-2J.png","width":987,"height":948,"caption":"An image of a Longer WT600-2J peristaltic pump without background"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/how-to-control-the-longer-wt600-2j-pump-via-python/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"How to Control the Longer WT600-2J(1J)(3J) Pump via Python ?"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Unser Blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/WT600-2J.png","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/21476","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=21476"}],"version-history":[{"count":49,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/21476/revisions"}],"predecessor-version":[{"id":33688,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/21476/revisions/33688"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/21340"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=21476"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=21476"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=21476"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}