{"id":23929,"date":"2024-06-10T14:50:28","date_gmt":"2024-06-10T12:50:28","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=23929"},"modified":"2026-11-19T15:25:03","modified_gmt":"2026-11-19T14:25:03","slug":"how-to-control-a-labv-pump-using-the-modbus-protocol","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/","title":{"rendered":"How to Control a LabV Pump Using the MODBUS Protocol ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"23929\" class=\"elementor elementor-23929\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-945466f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"945466f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e6bfbc6\" data-id=\"e6bfbc6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b686b58 elementor-widget elementor-widget-text-editor\" data-id=\"b686b58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die <strong><a href=\"https://darwin-microfluidics.com/de/produkte/labv1-iii-intelligent-durchflussrate-schlauchpumpe\">LabV</a></strong> Pumpenserie von <a href=\"https://darwin-microfluidics.com/de/search-results-page?q=innofluid\"><strong>Innofluid</strong></a> (früher bekannt als <strong>Shenchen Baoding</strong>) ist eine fortschrittliche Serie von Schlauchpumpen zur Durchflussmessung mit einem 4,3-Zoll-Farbtouchscreen für eine intuitive Steuerung. Sie zeigt Durchflussdaten, Einstellungen und Systeminformationen gleichzeitig an, wobei Animationen den Arbeitszustand verdeutlichen. Ausgestattet mit intelligenter Kalibrierung, Online-Feinjustierung und drei Messmodi – festes Volumen, feste Zeit und Volumen sowie Timer-Start/Stopp – ist sie äußerst vielseitig. Kompatibel mit verschiedenen Pumpenköpfen und mit mehreren contrôle externe ausgestattet, ist die LabV Serie ideal für den Laboreinsatz, die Geräteintegration und die industrielle Produktion.</p><p>In diesem Blogbeitrag zeigen wir, wie Sie die LabV Pumpen über das <strong>MODBUS RTU-Protokoll</strong> mit einer gängigen Programmierplattform steuern: Python.</p><p>Es ist erwähnenswert, dass es zwar geringfügige Unterschiede bei der Registerkonfiguration und den Befehlen zwischen verschiedenen Lab-Pumpenserien (wie <strong>LabF</strong>, <strong>LabN</strong>, <strong>LabK</strong> usw.) geben kann, diese jedoch alle dasselbe MODBUS RTU-Kommunikationsprotokoll verwenden. Daher sind die in diesem Artikel dargelegten Erkenntnisse für Anwender jeglicher Innofluid Lab-Pumpenserie relevant und anwendbar.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-90b242d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"90b242d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-54151b7\" data-id=\"54151b7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9c7f5a9 elementor-widget elementor-widget-heading\" data-id=\"9c7f5a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Warum sollten Sie sich für einen „ Schlauchpumpe “ der LabV-Serie entscheiden?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db75143 elementor-widget elementor-widget-text-editor\" data-id=\"db75143\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die LabV Schlauchpumpe ist eine erstklassige Wahl für Fluidik-Anwendungen in Labor- und Industrieumgebungen. Ausgestattet mit einem neuen Servomotor für verbesserte Präzision und Langlebigkeit sowie einer 4,3&quot; LCD-Touchscreen-Schnittstelle bietet diese Pumpe eine intuitive Steuerung für präzises Dosieren und feste Volumina. Gefertigt aus laborüblichem ABS gewährleistet sie sowohl eine einfache Handhabung als auch eine robuste Leistung.</p><p>Mit Durchflussraten von 0,0053 µL/min bis 775 mL/min und der Flexibilität, bis zu 8 Kanäle zu unterstützen, eignet es sich für ein breites Spektrum an Anwendungen. Darüber hinaus machen seine robuste Bauweise, das dynamische Display und die intelligente Kalibrierungsfunktion es zu einem zuverlässigen Werkzeug für verschiedene Flüssigkeit Transferaufgaben.</p><p>Ob für die Forschung, die Geräteversorgung oder die industrielle Fertigung – die Peristaltikpumpen der LabV-Serie sind eine hervorragende Lösung für Herausforderungen im Bereich der Flüssigkeit n Handhabung.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-be2b383 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"be2b383\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-722f9ad\" data-id=\"722f9ad\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e3b3085 elementor-widget elementor-widget-heading\" data-id=\"e3b3085\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Was wird für die Kommunikation mit einer LabV Pumpe benötigt?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ae42d9 elementor-widget elementor-widget-text-editor\" data-id=\"5ae42d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Um über das MODBUS-RTU-Protokoll mit einer LabV-Pumpe zu kommunizieren, benötigen Sie Folgendes:</p><ul><li>Eine LabV Pumpe (hier wird eine <a href=\"https://darwin-microfluidics.com/de/produkte/labv1-iii-intelligent-durchflussrate-schlauchpumpe\">LabV1-III Intelligent Flow Rate Peristaltic Pump</a> verwendet) mit einem <a href=\"https://darwin-microfluidics.com/de/collections/schlauchpumpe-pumpenkopf\">Pumpenkopf</a> und einem <a href=\"https://darwin-microfluidics.com/de/collections/schlauchpumpe-schlauche\">tube</a> Ihrer Wahl</li><li>Ein <a href=\"https://darwin-microfluidics.com/de/produkte/usb-zu-rs485-seriell-konverter-kabel/\">Serienkabel</a> zur Verbindung mit Ihrem Computer oder Gerät</li><li>Eine RS485- oder RS232-Verdrahtung am contrôle externe-Anschluss an der Rückseite der Pumpe</li><li>Eine Programmierplattform (in diesem Fall Python)</li><li>Ein grundlegendes Verständnis des MODBUS RTU-Kommunikationsprotokolls, das <a href=\"#modbus\">unten 👇</a> beschrieben wird.</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e9139aa elementor-widget elementor-widget-global elementor-global-18316 elementor-widget-pix-promo-box\" data-id=\"e9139aa\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta1\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Tubing_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"SUCHEN SIE NACH FLEXIBLEN OPTIONEN FÜR „ Schläuche “?\"><a href=\"https://darwin-microfluidics.com/de/collections/microfluidic-schlauche\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Entdecken Sie unsere Auswahl!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">SUCHEN SIE NACH FLEXIBLEN OPTIONEN FÜR „ Schläuche “?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Entdecken Sie unsere mikrofluidischen tube-Lösungen für einen zuverlässigen und effizienten Durchfluss in Ihren Experimenten!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7a61ab4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7a61ab4\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a46e079\" data-id=\"a46e079\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5b9a150 elementor-widget elementor-widget-heading\" data-id=\"5b9a150\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie richtet man den Kommunikationsport ein?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26a39db elementor-widget elementor-widget-text-editor\" data-id=\"26a39db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bevor Sie Daten an die Pumpe senden und von ihr empfangen können, müssen Sie den Kommunikationsport korrekt einrichten. Hier sind die zu befolgenden Schritte:</p><ul><li>Schließen Sie das Kabel für die RS232- oder RS485-Kommunikation an den contrôle externe-Anschluss an der Rückseite der Pumpe an.</li><li>Schalten Sie die Pumpe ein</li><li>Wählen Sie in der <a href=\"#communication_interface\">Kommunikationseinstellungs-Schnittstelle</a> auf dem Pumpenbildschirm RS232 oder RS485 als Kommunikationsschnittstelle aus (Details zur RS232- und RS485-Verdrahtung finden Sie in den folgenden <a href=\"#wiring\">Tabellen</a>)</li><li>Unabhängig davon, ob Sie sich für RS232 oder RS485 entscheiden, verwendet das Kommunikationsprotokoll den Standard MODBUS RTU.</li><li>Stellen Sie die Baudrate ein</li><li>Klicken Sie auf die Schaltfläche <strong>Slave No.</strong>, um die Adresse der Schlauchpumpe einzustellen (Bereich: 1–32)</li><li>Kommunikationsfreigabe auf <strong>ON</strong> stellen</li><li><strong><em>Kehren Sie zur Hauptoberfläche zurück, da die Pumpe Steuerungsbefehle über die Kommunikation nur in der Hauptoberfläche empfängt; in anderen Einstellungsmenüs ist die Kommunikationssteuerung nicht aktiv.</em></strong></li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ad7815 elementor-widget elementor-widget-image\" data-id=\"3ad7815\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"communication_interface\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"384\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/06/communication-interface-1024x614.png\" class=\"attachment-large size-large wp-image-24348\" alt=\"Ein Screenshot der Kommunikationsschnittstelle der LabV1-III Pumpe\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/06/communication-interface-1024x614.png 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/06/communication-interface-300x180.png 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/06/communication-interface-768x460.png 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/06/communication-interface.png 1153w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5217f89 elementor-widget elementor-widget-text-editor\" data-id=\"5217f89\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"wiring\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\n\n<table>\n    <thead>\n        <tr>\n            <th colspan=\"2\" class=\"section-header\">Details zur RS232-Verdrahtung</th>\n        </tr>\n        <tr>\n            <th class=\"smaller-column\">Terminal</th> <!-- Apply class to first column -->\n            <th>Beschreibung</th>\n        </tr>\n    </thead>\n    <tbody>\n        <tr>\n            <td>GND</td>\n            <td>Masseanschluss für die Kommunikation.</td>\n        </tr>\n        <tr>\n            <td>TXD</td>\n            <td>Sendeterminal des Masters, Empfangssignalterminal der Schlauchpumpe.</td>\n        </tr>\n        <tr>\n            <td>RXD</td>\n            <td>Sendeterminal der Schlauchpumpe, Empfangssignalterminal des Masters.</td>\n        </tr>\n    </tbody>\n</table>\n\n<table>\n    <thead>\n        <tr>\n            <th colspan=\"2\" class=\"section-header\">RS485-Verdrahtungsdetails</th>\n        </tr>\n        <tr>\n            <th class=\"smaller-column\">Terminal</th> <!-- Apply class to first column -->\n            <th>Beschreibung</th>\n        </tr>\n    </thead>\n    <tbody>\n        <tr>\n            <td>GD1</td>\n            <td>RS485-Signalmasse.</td>\n        </tr>\n        <tr>\n            <td>A+</td>\n            <td>RS485 A+-Terminal anschließen.</td>\n        </tr>\n        <tr>\n            <td>B-</td>\n            <td>RS485 B- Klemme anschließen.</td>\n        </tr>\n    </tbody>\n</table>\n\n\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-86803c4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"86803c4\" data-element_type=\"section\" data-e-type=\"section\" id=\"modbus\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6418f5a\" data-id=\"6418f5a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-26f7418 elementor-widget elementor-widget-heading\" data-id=\"26f7418\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Das MODBUS RTU Kommunikationsprotokoll der LabV-Serie</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a3697f elementor-widget elementor-widget-text-editor\" data-id=\"0a3697f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die Schlauchpumpen der LabV-Serie bieten einen umfassenden Befehlssatz zur präzisen Steuerung und Überwachung über das MODBUS RTU-Protokoll. Dieser Befehlssatz umfasst verschiedene kategorisierte Direktiven zur einfachen Handhabung der Pumpenfunktionen, einschließlich Motordrehzahleinstellungen, Flussratenkonfigurationen, Pumpenkopfauswahl und Kalibrierungsroutinen. Jeder durch eindeutige Parameter identifizierte Befehl gewährleistet eine präzise Kontrolle über den Betrieb der Pumpe.</p><p>Detaillierte Erläuterungen und weitere Informationen zum MODBUS RTU-Protokoll für die Steuerung der LabV-Pumpen werden im Folgenden bereitgestellt und sind auch in der <a href=\"https://darwin-microfluidics.com/content/pdfs/Lab-V-Series-MODBUS-Protocol.pdf\" target=\"_blank\" rel=\"noopener\">Dokumentation des Kommunikationsprotokolls</a> zu finden.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8fcce94 elementor-widget elementor-widget-heading\" data-id=\"8fcce94\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">MODBUS RTU Standard-Kommunikationsformat</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b4fe20 elementor-widget elementor-widget-text-editor\" data-id=\"9b4fe20\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das Nachrichtenformat entspricht der Darstellung in der nachstehenden Tabelle. </p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-590b794 elementor-widget elementor-widget-text-editor\" data-id=\"590b794\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table><tbody><tr><th>Feld</th><th>Größe</th><th>Beschreibung</th></tr><tr><td>Slave-Adresse</td><td>1 Byte</td><td>Adresse der Pumpe. Der Nummernkreis liegt zwischen 1 und 32, wobei 0 für Broadcast verwendet wird.</td></tr><tr><td>Funktionscode</td><td>1 Byte</td><td>Befehl für das Slave-Gerät.<br><strong>03H</strong>: Holding-Register lesen<br><strong>06H</strong>: Einzelnes Register schreiben<br><strong>10H</strong>: Mehrere Register schreiben<br><strong>02H</strong>: Diskrete Eingänge lesen (Datenbits lesen)<br><strong>05H</strong>: Einzelnes Bit in Register schreiben</td></tr><tr><td>Datenbereich</td><td>0 – 252 Bytes</td><td>Zu übertragende Daten (variable Länge)</td></tr><tr><td>CRC-Prüfung</td><td>2 Bytes</td><td>Zyklische Redundanzprüfung zur Fehlererkennung<br>CRC low (1 Byte): Niederwertiges Byte der CRC<br>CRC high (1 Byte): Höherwertiges Byte der CRC</td></tr></tbody></table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-380bcf6 elementor-widget elementor-widget-heading\" data-id=\"380bcf6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">CRC-Prüfung mit CRC-16 in Python</h4>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ca75b1 elementor-widget elementor-widget-text-editor\" data-id=\"5ca75b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>CRC (Cyclic Redundancy Check) ist eine essenzielle Technik zur Erkennung von Übertragungsfehlern. Im Folgenden zeigen wir anhand von Python, wie CRC-16 implementiert wird – jene Variante, die im amerikanischen binären synchronen System verwendet wird.\n\nBeim CRC-16 verwendet der Fehlererkennungsalgorithmus ein Polynom <span style=\"background-color: lightgray;\">G(X) = X<sup>16</sup> + X<sup>15</sup> + X<sup>2</sup> + 1</span> zur Generierung der Prüfsumme. Dieses Polynom definiert die mathematischen Operationen, die während des CRC-Berechnungsprozesses an den Bits der Nachricht durchgeführt werden. Eine Übersicht des Algorithmus ist nachfolgend detailliert aufgeführt:\n</p><ul>\n \t<li>Initialisieren Sie ein 16-Bit-Register mit dem Hexadezimalwert FFFF (nur Einsen), das als CRC-Register bezeichnet wird.</li>\n \t<li>Führen Sie eine XOR-Verknüpfung der ersten 8 Bytes der Nachricht mit dem niederwertigen Byte des CRC-Registers durch. Speichern Sie das Ergebnis wieder im CRC-Register.</li>\n \t<li>Verschieben Sie das CRC-Register um ein Bit nach rechts, wobei das höchstwertige Bit (MSB) auf Null gesetzt wird.</li>\n \t<li>Überprüfen Sie das niederwertigste Bit (LSB) des CRC-Registers:\n<ul>\n \t<li>Wenn das LSB 0 ist, wiederholen Sie Schritt 3 (Schiebeoperation).</li>\n \t<li>Wenn das LSB 1 ist, führen Sie eine XOR-Verknüpfung des CRC-Registers mit dem Polynomwert 0xA001 (1010 0000 0000 0001) durch.</li>\n</ul>\n</li>\n \t<li>Wiederholen Sie die Schritte 3 bis 4 für insgesamt 8 Verschiebungen, um jedes Byte zu verarbeiten.</li>\n \t<li>Wiederholen Sie die Schritte 2 bis 5 für jedes Byte in der Nachricht, bis alle Bytes verarbeitet wurden.</li>\n \t<li>Der finale Inhalt des CRC-Registers entspricht dem CRC-Wert.</li>\n</ul>\n🚨 <em>In der Nachricht müssen das High- und Low-Byte der CRC-Werte vertauscht werden.</em>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-262e27e elementor-widget elementor-widget-heading\" data-id=\"262e27e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Kommunikationseinstellungen</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b164570 elementor-widget elementor-widget-text-editor\" data-id=\"b164570\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Jedes Datenbyte besitzt eine Struktur aus 1 Startbit, 8 Datenbits, 1 Paritätsbit und 1 Stoppbit. Die Bits werden in der Reihenfolge vom least significant bit (LSB) zum most significant bit (MSB) übertragen. Zu den möglichen Kommunikations-Baudraten gehören 1200, 2400, 4800 und 9600 Baud.</p><p>Bei Ganzzahlen (2 Bytes) sind die Daten so angeordnet, dass das zweite Byte zuerst und das erste Byte danach folgt. Der Hexadezimalwert 2378H wird beispielsweise als 23H 78H gesendet. Bei langen Ganzzahlen und Gleitkommazahlen (4 Bytes) ist das vierte Byte zuerst angeordnet, gefolgt vom dritten, zweiten und ersten Byte.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b0b1a1b elementor-widget elementor-widget-heading\" data-id=\"b0b1a1b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">MODBUS-Nachrichten-RTU-Frame-Format</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1e40ee2 elementor-widget elementor-widget-text-editor\" data-id=\"1e40ee2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Das RTU-Frame-Format der MODBUS-Nachricht entspricht der Beschreibung in der folgenden Tabelle. </p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c2be73c elementor-widget elementor-widget-text-editor\" data-id=\"c2be73c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table><tbody><tr><th>Feld</th><th>Größe</th><th>Beschreibung</th></tr><tr><td>Start</td><td>≥ 3,5 Zeichen</td><td>Signaleisiert den Beginn der Übertragung</td></tr><tr><td>Adresse</td><td>8 Bits</td><td>Adresse des Slave-Geräts</td></tr><tr><td>Funktionscode</td><td>8 Bits</td><td>Befehl für das Slave-Gerät</td></tr><tr><td>Daten</td><td>N x 8 Bits</td><td>Zu übertragende Daten (variable Länge, N Bytes)</td></tr><tr><td>CRC-Prüfcode</td><td>16 Bits</td><td>Zyklische Redundanzprüfung zur Fehlererkennung</td></tr><tr><td>Ende</td><td>≥ 3,5 Zeichen</td><td>Signalisiert das Ende der Übertragung</td></tr></tbody></table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14e516f elementor-widget elementor-widget-text-editor\" data-id=\"14e516f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>🚨 Stellen Sie sicher, że der Nachrichtenrahmen kontinuierlich ohne Leerzeiten zwischen den Zeichen von mehr als 1,5 Zeichenzeiten übertragen wird. Unvollständige Nachrichtenrahmen, die durch übermäßige Leerzeiten gekennzeichnet sind, sollten vom empfangenden Knoten verworfen werden.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1dae4c6 elementor-widget elementor-widget-heading\" data-id=\"1dae4c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Fehlerreaktion</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e5d5fb4 elementor-widget elementor-widget-text-editor\" data-id=\"e5d5fb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wenn ein Host eine Datenanfrage sendet und der Slave fehlerhafte Daten empfängt, sollte dies eine Fehlerreaktion auslösen. Ist der vom Host gesendete Adresscode falsch, d. h. entspricht er keinem der Adresscodes der Slaves, oder besteht der vom Slave empfangene Datensatz die CRC-Prüfung nicht, wird kein Fehlercode zurückgegeben. In solchen Fällen sollte der Host einen übergeordneten Reaktionsprozess einleiten.</p><p>Im Funktionscodebereich ist der Funktionscode für die Fehlerreaktion als der normale Funktionscode plus 80H definiert.</p><p>Im Datenbereich ist der zurückzugebende Fehlercode in der nachstehenden Tabelle definiert.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e40c00f elementor-widget elementor-widget-text-editor\" data-id=\"e40c00f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table>\n<tbody>\n<tr>\n<th>Code</th>\n<th>Name</th>\n<th>Bedeutung</th>\n</tr>\n<tr>\n<td>01H</td>\n<td>Ungültiger Funktionscode</td>\n<td>Der von der Schlauchpumpe empfangene Funktionscode ist nicht zulässig, mit Ausnahme von 03H, 06H oder 10H.</td>\n</tr>\n<tr>\n<td>02H</td>\n<td>Ungültige Datenadresse</td>\n<td>Die von der Schlauchpumpe empfangene Registeradresse ist nicht zulässig.</td>\n</tr>\n<tr>\n<td>03H</td>\n<td>Ungültiger Datenwert</td>\n<td>Die geschriebenen Daten entsprechen nicht dem von der „ Schlauchpumpe “ erwarteten Betriebsbereich.</td>\n</tr>\n<tr>\n<td>06H</td>\n<td>Slave (Schlauchpumpe) beschäftigt</td>\n<td>Die Schlauchpumpe ist derzeit beschäftigt und kann den Befehl aufgrund eines konfligierenden Zustands nicht ausführen.</td>\n</tr>\n</tbody>\n</table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-576496b elementor-widget elementor-widget-text-editor\" data-id=\"576496b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em> 🚨Die Schlauchpumpe akzeptiert MODBUS-Befehle <strong>nur</strong> über das <strong>Main Interface</strong>; andere Schnittstellen empfangen keine Nachrichten.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1df5e34 elementor-widget elementor-widget-heading\" data-id=\"1df5e34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Adresse und Inhalt des Holding-Registers</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b7d2fc9 elementor-widget elementor-widget-text-editor\" data-id=\"b7d2fc9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Nachfolgend finden Sie die Tabellen zur Einstellung der Basis- bzw. Kalibrierungsparameter.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55231ab elementor-widget elementor-widget-heading\" data-id=\"55231ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Einstellung der Basisparameter</h4>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b191150 elementor-widget elementor-widget-text-editor\" data-id=\"b191150\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table><tbody><tr><th>Adresse (Dezimal)</th><th>Name</th><th>Bereich</th><th>Datentyp</th></tr><tr><td>1000</td><td>Pumpenkopf</td><td>Bezog sich auf <a href=\"#chart\">Diagramm 1</a></td><td>unsigned short int (2 Byte)</td></tr><tr><td>1001</td><td>Schläuche Größe</td><td>Bezog sich auf <a href=\"#chart\">Diagramm 1</a></td><td>unsigned short int (2 Byte)</td></tr><tr><td>1002</td><td>Motordrehzahl</td><td>0,1–600 U/min</td><td>float (4 Byte)</td></tr><tr><td>1004</td><td>Durchflussrate</td><td>0,1–99999 mL</td><td>float (4 Byte)</td></tr><tr><td>1007</td><td>Rückabsaugwinkel</td><td>0-360°</td><td>unsigned short int (2 Byte)</td></tr><tr><td>1008</td><td>Start-/Stopp-Steuerung</td><td>1: Start, 0: Stopp</td><td>unsigned short int (2 Byte)</td></tr><tr><td>1009</td><td>Richtungsteuerung</td><td>1: Im Uhrzeigersinn, 0: Gegen den Uhrzeigersinn</td><td>unsigned short int (2 Byte)</td></tr><tr><td>1010</td><td>Betrieb mit voller Geschwindigkeit</td><td>1: Start mit voller Geschwindigkeit, 0: Stopp mit voller Geschwindigkeit</td><td>unsigned short int (2 Byte)</td></tr><tr><td>1015</td><td>Fördervolumen einstellen</td><td>0-99999 mL</td><td>float (4 Byte)</td></tr><tr><td>1018</td><td>Arbeitszeit</td><td>0,1-9999 s</td><td>float (4 Byte)</td></tr><tr><td>1020</td><td>Betriebsmodus</td><td>0: Transferieren, 1: Feste Volumenmessung, 2: Feste Zeit und Volumen</td><td>unsigned short int (2 Byte)</td></tr><tr><td>1021</td><td>Pausenzeit</td><td>0,1-9999 s</td><td>float (4 Byte)</td></tr><tr><td>1023</td><td>Kopienanzahl</td><td>0-9999 mal, 0 bedeutet unendlich</td><td>unsigned short int (2 Byte)</td></tr></tbody></table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-babad56 elementor-widget elementor-widget-text-editor\" data-id=\"babad56\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>💡 Wichtige Hinweise:</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a125de elementor-widget elementor-widget-text-editor\" data-id=\"0a125de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Die Register 1015 und 1018 sind ungültig, wenn der Arbeitsmodus auf Transferieren eingestellt ist.</li><li>Register 1018 ist ungültig, wenn der Arbeitsmodus auf Feste Volumenmessung eingestellt ist.</li><li>Die Register 1002 und 1004 sind ungültig, wenn der Arbeitsmodus auf Feste Zeit und Volumen eingestellt ist.</li><li>Stellen Sie sicher, dass die Registerdaten gemäß der bereitgestellten Tabelle eingestellt werden, und vermeiden Sie es, mehrere Registerkonfigurationen in einem einzigen Befehl zu senden.</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb95a83 elementor-widget elementor-widget-heading\" data-id=\"bb95a83\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Einstellung der Kalibrierungsparameter</h4>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9fd118 elementor-widget elementor-widget-text-editor\" data-id=\"a9fd118\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table>\n<tbody>\n<tr>\n<th>Adresse (Dezimal)</th>\n<th>Name</th>\n<th>Bereich</th>\n<th>Datentyp</th>\n</tr>\n<tr>\n<td>2001</td>\n<td>Testzeit</td>\n<td>0,5-9999 s</td>\n<td>unsigned short int (2 Byte)</td>\n</tr>\n<tr>\n<td>2002</td>\n<td>Test Start/Stopp</td>\n<td>1: Start, 0: Stopp</td>\n<td>unsigned short int (2 Byte)</td>\n</tr>\n<tr>\n<td>2003</td>\n<td>Ist-Volumen</td>\n<td>0-9999 mL</td>\n<td>float (4 Byte)</td>\n</tr>\n<tr>\n<td>2005</td>\n<td>Standardeinstellungen wiederherstellen</td>\n<td>1: Kalibrierung wiederherstellen</td>\n<td>unsigned short int (2 Byte)</td>\n</tr>\n<tr>\n<td>2006</td>\n<td>Feineinstellung</td>\n<td>1: Erhöhen, 0: Verringern</td>\n<td>unsigned short int (2 Byte)</td>\n</tr>\n</tbody>\n</table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-252d9bc elementor-widget elementor-widget-heading\" data-id=\"252d9bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Übersichtstabelle für Pumpenköpfe und tube</h4>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25f8eba elementor-widget elementor-widget-text-editor\" data-id=\"25f8eba\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"chart\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table>\n  <tbody>\n    <tr>\n      <th>Pumpenkopfbezeichnung</th>\n      <th>Pumpenkopftyp</th>\n      <th>Schläuche Größe</th>\n      <th>tube-Spezifikation</th>\n    </tr>\n    <tr>\n      <td rowspan=\"7\">EasyPumpI</td>\n      <td rowspan=\"7\">0</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"4\">EasyPumpII</td>\n      <td rowspan=\"4\">1</td>\n      <td>15</td>\n      <td>15#</td>\n    </tr>\n    <tr>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n    <tr>\n      <td>35</td>\n      <td>35#</td>\n    </tr>\n    <tr>\n      <td>36</td>\n      <td>36#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"7\">EasyPumpIII</td>\n      <td rowspan=\"7\">2</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"4\">EasyPumpIV</td>\n      <td rowspan=\"4\">3</td>\n      <td>15</td>\n      <td>15#</td>\n    </tr>\n    <tr>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n    <tr>\n      <td>35</td>\n      <td>35#</td>\n    </tr>\n    <tr>\n      <td>36</td>\n      <td>36#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"5\">EasyPumpV</td>\n      <td rowspan=\"5\">4</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"5\">EasyPumpVI</td>\n      <td rowspan=\"5\">5</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"7\">2*EasyPumpI</td>\n      <td rowspan=\"7\">6</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"4\">2*EasyPumpII</td>\n      <td rowspan=\"4\">7</td>\n      <td>15</td>\n      <td>15#</td>\n    </tr>\n    <tr>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n    <tr>\n      <td>35</td>\n      <td>35#</td>\n    </tr>\n    <tr>\n      <td>36</td>\n      <td>36#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"7\">2*EasyPumpIII</td>\n      <td rowspan=\"7\">8</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n\n    <tr>\n      <td rowspan=\"7\">YZ1515x</td>\n      <td rowspan=\"7\">12</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"2\">YZ2515x</td>\n      <td rowspan=\"2\">13</td>\n      <td>15</td>\n      <td>15#</td>\n    </tr>\n    <tr>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n\n\n    <tr>\n      <td rowspan=\"4\">DZ25-3L</td>\n      <td rowspan=\"4\">18</td>\n      <td>15</td>\n      <td>15#</td>\n    </tr>\n    <tr>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n    <tr>\n      <td>35</td>\n      <td>35#</td>\n    </tr>\n    <tr>\n      <td>36</td>\n      <td>36#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"5\">UC15</td>\n      <td rowspan=\"5\">20</td>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"3\">UC25</td>\n      <td rowspan=\"3\">21</td>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n    <tr>\n      <td>35</td>\n      <td>35#</td>\n    </tr>\n    <tr>\n      <td>36</td>\n      <td>36#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"2\">SN15</td>\n      <td rowspan=\"2\">22</td>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"1\">SN25</td>\n      <td rowspan=\"1\">23</td>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n  </tbody>\n</table>\n\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c77785 elementor-widget elementor-widget-text-editor\" data-id=\"3c77785\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>💡 Wichtiger Hinweis:</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54d3317 elementor-widget elementor-widget-text-editor\" data-id=\"54d3317\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>Die obige Tabelle ist nicht erschöpfend und enthält nur eine Auswahl an Pumpenköpfen und tube-Größen. Die vollständige Liste finden Sie in der Dokumentation.</li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e5e0a2 elementor-widget elementor-widget-heading\" data-id=\"5e5e0a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Beispiele für Befehlszeilen</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3fbb3ff elementor-widget elementor-widget-text-editor\" data-id=\"3fbb3ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Beispiel 1: Pumpe starten</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a05e55 elementor-widget elementor-widget-text-editor\" data-id=\"5a05e55\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Adresse: <strong>01</strong> gibt die Geräteadresse an, an die der Befehl gesendet wird.</li><li>Funktionscode: <strong>06</strong>, wird verwendet, um einen einzelnen Wert in ein Register zu schreiben.</li><li>Registeradresse: <strong>03F0</strong>, Registeradresse entsprechend dem Steuerregister zum Starten der Pumpe (1008 im Hexadezimalformat).</li><li>Daten: <strong>0001</strong>, in das Register geschrieben, um die Pumpe zu starten (1: Start, 0: Stopp).</li><li>CRC: <strong>487D</strong>, Wert zur Sicherstellung der Datenintegrität.</li></ul><p>Daraus ergibt sich folgender Befehlsstring zum Starten der Pumpe: <strong>01 06 03 F0 00 01 48 7D</strong>.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1dfded8 elementor-widget elementor-widget-text-editor\" data-id=\"1dfded8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Beispiel 2: Pumpendrehzahl auf 20 rpm einstellen</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f483acb elementor-widget elementor-widget-text-editor\" data-id=\"f483acb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Adresse: <strong>01</strong> gibt die Geräteadresse an, an die der Befehl gesendet wird.</li><li>Funktionscode: <strong>10</strong>, wird verwendet, um Werte in mehrere Register zu schreiben.</li><li>Registeradresse: <strong>03EA</strong>, Registeradresse entsprechend dem Drehzahleinstellregister (1002 im Hexadezimalformat).</li><li>Anzahl der Register: <strong>0002</strong>, es werden zwei Register beschrieben.</li><li>Byte-Anzahl: <strong>04</strong>, Anzahl der zu schreibenden Datenbytes.</li><li>Daten: <strong>41A00007</strong>, repräsentiert die Drehzahleinstellung im Gleitkommaformat entsprechend 20 RPM.</li><li>CRC: <strong>D76E</strong>, Wert zur Sicherstellung der Datenintegrität.</li></ul><p>Daraus ergibt sich folgender Befehlsstring zum Einstellen der Pumpendrehzahl auf 20 rpm: <strong>01 10 03 EA 00 02 04 41 A0 00 07 D7 6E</strong>.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-898c1b9 elementor-widget elementor-widget-text-editor\" data-id=\"898c1b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diese 2 Beispiele sowie weitere Beispiele für Befehlsstrings sind in der folgenden Tabelle dargestellt.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35b72b2 elementor-widget elementor-widget-text-editor\" data-id=\"35b72b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table>\n<tbody>\n<tr>\n<th>Aufgabe</th>\n<th>Befehlsstring</th>\n</tr>\n<tr>\n<td>Pumpe starten</td>\n<td>01 06 03 F0 00 01 48 7D</td>\n</tr>\n<tr>\n<td>Richtung auf CCW einstellen</td>\n<td>01 06 03 F1 00 00 D8 7D</td>\n</tr>\n<tr>\n<td>Richtung auf CW einstellen</td>\n<td>01 06 03 F1 00 01 19 BD</td>\n</tr>\n<tr>\n<td>Drehzahl auf 20 RPM einstellen</td>\n<td>01 10 03 EA 00 02 04 41 A0 00 07 D7 6E</td>\n</tr>\n<tr>\n<td>Flussrate auf 50,0 mL/min einstellen</td>\n<td>01 10 03 EC 00 02 04 42 48 00 00 7D 2C</td>\n</tr>\n<tr>\n<td>Pumpe stoppen</td>\n<td>01 06 03 F0 00 00 89 BD</td>\n</tr>\n<tr>\n<td>Start mit voller Drehzahl</td>\n<td>01 06 03 F2 00 01 E9 BD</td>\n</tr>\n</tbody>\n</table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-91454a9 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"91454a9\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e1fd1c0\" data-id=\"e1fd1c0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0196ace elementor-widget elementor-widget-heading\" data-id=\"0196ace\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wie steuert man die LabV Pumpen mit Python?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24bb349 elementor-widget elementor-widget-text-editor\" data-id=\"24bb349\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Die LabV Pumpenserie kann über Python per MODBUS RTU Protokoll remote gesteuert werden, was eine höhere Flexibilität und Benutzerfreundlichkeit bei der Durchführung komplexer Pumpenprogramme mit Schleifen, Pausen und variierenden Geschwindigkeiten bzw. Flussraten bietet. Dieser Ansatz ist besonders nützlich bei der Integration mehrerer Geräte, da er die Automatisierung von Sequenzen aller angeschlossenen Komponenten ermöglicht.</p><p>In diesem Abschnitt wird eine spezielle, benutzerdefinierte Python-Bibliothek vorgestellt, die das MODBUS RTU Protokoll nutzt, um die serielle Schnittstelle zu öffnen und Steuerungsbefehle an die LabV Pumpe zu senden. Wir behandeln Beispiele zur Einstellung der Geschwindigkeit, zum Starten und Stoppen der Pumpe, zur Konfiguration von Pumpenkopf und tube Größe usw. und bieten damit einen praxisbezogenen Leitfaden für die Steuerung einer LabV Pumpe mittels Python.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c485fe4 elementor-widget elementor-widget-text-editor\" data-id=\"c485fe4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>🚨🚨🚨 Wichtiger Hinweis</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9e8210c elementor-widget elementor-widget-text-editor\" data-id=\"9e8210c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>When viewing this code, please be aware that <strong><span style=\"color: red;\">&lt;</span></strong>, <strong><span style=\"color: red;\">&gt;</span></strong>, and <strong><span style=\"color: red;\">&amp;</span></strong> symbols might not display correctly due to formatting issues. These should appear as standard Python code syntax, so make sure to interpret <strong><span style=\"color: red;\">&amp;lt;</span></strong> as <strong><span style=\"color: red;\">&lt;</span></strong>,<strong> <span style=\"color: red;\">&amp;gt;</span></strong> as <strong><span style=\"color: red;\">&gt;</span></strong>, and <strong><span style=\"color: red;\">&amp;amp;</span></strong> as <strong><span style=\"color: red;\">&amp;</span></strong>.</li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ce25554 elementor-widget elementor-widget-code-highlight\" data-id=\"ce25554\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"code-highlight.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"prismjs-tomorrow copy-to-clipboard \">\n\t\t\t<pre data-line=\"\" class=\"highlight-height language-python line-numbers\">\n\t\t\t\t<code readonly=\"\" class=\"language-python\">\n\t\t\t\t\t<xmp>'''\r\n-----------------------------------------------------------\r\nLABV Peristaltic Pump Control Library Using Modbus Protocol\r\n-----------------------------------------------------------\r\n'''\r\n\r\nimport serial\r\nimport struct\r\n\r\n#------------------------------------------------------#\r\n#   LIBRARY MANAGING THE COMMUNICATION WITH THE PUMP   #\r\n#------------------------------------------------------#\r\n\r\nclass LABV:\r\n    \r\n    # Initialize the object and establish a serial connection with the corresponding data format\r\n    def __init__(self, port, address=1, baudrate=9600, parity='E', bytesize=8, stopbits=1, timeout=1):\r\n        self.ser = serial.Serial(port=port, baudrate=baudrate, parity=parity,\r\n                                 bytesize=bytesize, stopbits=stopbits, timeout=timeout)\r\n        self.address = address\r\n\r\n    # Connect the pump\r\n    def connect(self):\r\n        if not self.ser.is_open:\r\n            self.ser.open()\r\n\r\n    # Close the serial connection\r\n    def disconnect(self):\r\n        if self.ser.is_open:\r\n            self.ser.close()\r\n\r\n    # Calculate the CRC (Cyclic Redundancy Check) for data integrity as\r\n    # explained in \"The MODBUS RTU Communication Protocol\" section\r\n    def _calculate_crc(self, data):\r\n        crc = 0xFFFF\r\n        for byte in data:\r\n            crc ^= byte\r\n            for _ in range(8):\r\n                if crc &amp; 0x0001:\r\n                    crc &gt;&gt;= 1\r\n                    crc ^= 0xA001\r\n                else:\r\n                    crc &gt;&gt;= 1\r\n        return crc.to_bytes(2, byteorder='little')\r\n\r\n    # Convert data into bytes for communication\r\n    def _prepare_data(self, data, data_type):\r\n        if data_type == 'float':\r\n            return struct.pack('&gt;f', data)\r\n        elif data_type == 'int':\r\n            return data.to_bytes(2, byteorder='big')\r\n        else:\r\n            raise ValueError(\"Data type not supported.\")\r\n\r\n    # Construct, send commands to the pump and verify the response\r\n    def _send_command(self, function_code, register_address, data, data_type):\r\n        data_bytes = self._prepare_data(data, data_type)\r\n        payload = bytearray([self.address, function_code])\r\n        payload.extend(register_address.to_bytes(2, byteorder='big'))\r\n\r\n        if function_code == 0x10:  # Write multiple registers\r\n            number_of_registers = len(data_bytes) // 2\r\n            payload.extend(number_of_registers.to_bytes(2, byteorder='big'))\r\n            payload.append(len(data_bytes))\r\n            payload.extend(data_bytes)\r\n        else:\r\n            payload.extend(data_bytes)\r\n\r\n        crc = self._calculate_crc(payload)\r\n        payload.extend(crc)\r\n        print(f\"Sending payload: {payload.hex()}\")  # Debug: Print the payload\r\n\r\n        self.ser.write(payload)\r\n        response = self.ser.read(8) # Adjust as per the device response length\r\n        if len(response) != 8:\r\n            raise ValueError(\"Invalid response length\")\r\n        if self._calculate_crc(response[:-2]) != response[-2:]:\r\n            raise ValueError(\"Invalid CRC\")\r\n        return response\r\n\r\n    #------------------------------#\r\n    #   BASIC PARAMETERS SETTING   #\r\n    #------------------------------#\r\n    \r\n    # Start the pump\r\n    def start_pump(self):\r\n        print(\"Starting pump...\")\r\n        response = self._send_command(0x06, 0x03F0, 0x0001, 'int')\r\n        print(f\"Start pump response: {response.hex()}\")\r\n        \r\n    # Stop the pump\r\n    def stop_pump(self):\r\n        print(\"Stopping pump...\")\r\n        response = self._send_command(0x06, 0x03F0, 0x0000, 'int')\r\n        print(f\"Stop pump response: {response.hex()}\")\r\n        \r\n    # Set the pump head\r\n    def set_pump_head(self, pump_head):\r\n        print(f\"Setting pump head to {pump_head}...\")\r\n        response = self._send_command(0x06, 0x03E8, pump_head, 'int')\r\n        print(f\"Set pump head response: {response.hex()}\")\r\n        \r\n    # Set the tube size\r\n    def set_tube_size(self, tube_size):\r\n        print(f\"Setting tube size to {tube_size}...\")\r\n        response = self._send_command(0x06, 0x03E9, tube_size, 'int')\r\n        print(f\"Set tube size response: {response.hex()}\")\r\n        \r\n    # Set the direction of rotation\r\n    def set_direction(self, direction):\r\n        print(f\"Setting direction to {direction}...\")\r\n        data = 0x0001 if direction.upper() == \"CW\" else 0x0000\r\n        response = self._send_command(0x06, 0x03F1, data, 'int')\r\n        print(f\"Set direction response: {response.hex()}\")\r\n        \r\n    # Set the speed of the pump in RPM\r\n    def set_speed(self, speed):\r\n        print(f\"Setting speed to {speed} RPM...\")\r\n        response = self._send_command(0x10, 0x03EA, speed, 'float')\r\n        print(f\"Set speed response: {response.hex()}\")\r\n\r\n    # Set the flow rate in mL/min\r\n    def set_flow_rate(self, flow_rate):\r\n        print(f\"Setting flow rate to {flow_rate} mL/min...\")\r\n        response = self._send_command(0x10, 0x03EC, flow_rate, 'float')\r\n        print(f\"Set flow rate response: {response.hex()}\")\r\n        \r\n    # Set the flow volume in mL\r\n    def set_flow_volume(self, volume):\r\n        print(f\"Setting flow volume to {volume} mL...\")\r\n        response = self._send_command(0x10, 0x03F3, volume, 'float')\r\n        print(f\"Set flow volume response: {response.hex()}\")\r\n\r\n    # Set the working time in seconds\r\n    def set_working_time(self, time):\r\n        print(f\"Setting working time to {time} seconds...\")\r\n        response = self._send_command(0x10, 0x03FA, time, 'float')\r\n        print(f\"Set working time response: {response.hex()}\")\r\n\r\n    # Set the working mode\r\n    def set_working_mode(self, mode):\r\n        \"\"\"\r\n        Working modes:\r\n        0: Transferring\r\n        1: Fixed volume measurement\r\n        2: Fixed time and volume\r\n        \"\"\"\r\n        if mode not in [0, 1, 2]:\r\n            raise ValueError(\"Invalid working mode. Must be 0, 1, or 2.\")\r\n        \r\n        print(f\"Setting working mode to {mode}...\")\r\n        response = self._send_command(0x06, 0x03FC, mode, 'int')\r\n        print(f\"Set working mode response: {response.hex()}\")\r\n        \r\n    # Set the pause time in seconds\r\n    def set_pause_time(self, time):\r\n        print(f\"Setting pause time to {time} seconds...\")\r\n        response = self._send_command(0x10, 0x03FD, time, 'float')\r\n        print(f\"Set pause time response: {response.hex()}\")\r\n\r\n    # Set the number of copies\r\n    def set_copy_numbers(self, numbers):\r\n        print(f\"Setting copy numbers to {numbers}...\")\r\n        response = self._send_command(0x06, 0x03FF, numbers, 'int')\r\n        print(f\"Set copy numbers response: {response.hex()}\")\r\n\r\n    # Set the back suction angle in degrees\r\n    def set_back_suction_angle(self, angle):\r\n        print(f\"Setting back suction angle to {angle} degrees...\")\r\n        response = self._send_command(0x06, 0x03EF, angle, 'int')\r\n        print(f\"Set back suction angle response: {response.hex()}\")\r\n\r\n    # Start or stop full speed running\r\n    def set_full_speed_running(self, start):\r\n        state = \"Start\" if start else \"Stop\"\r\n        print(f\"{state} full speed running...\")\r\n        data = 0x0001 if start else 0x0000\r\n        response = self._send_command(0x06, 0x03F2, data, 'int')\r\n        print(f\"{state} full speed running response: {response.hex()}\")\r\n        \r\n    #---------------------------------------#\r\n    #   CALIBRATION PARAMETERS SETTING UP   #\r\n    #---------------------------------------#\r\n    \r\n    # Set the testing time in seconds\r\n    def set_testing_time(self, time):\r\n        print(f\"Setting testing time to {time} seconds...\")\r\n        response = self._send_command(0x06, 0x07D1, time, 'int')\r\n        print(f\"Set testing time response: {response.hex()}\")\r\n        \r\n    # Start the calibration test\r\n    def start_test(self):\r\n        print(\"Starting test...\")\r\n        response = self._send_command(0x06, 0x07D2, 0x0001, 'int')\r\n        print(f\"Start test response: {response.hex()}\")\r\n        \r\n    # Stop the calibration test\r\n    def stop_test(self):\r\n        print(\"Stopping test...\")\r\n        response = self._send_command(0x06, 0x07D2, 0x0000, 'int')\r\n        print(f\"Stop test response: {response.hex()}\")\r\n        \r\n    # Set the actual volume in mL\r\n    def set_actual_volume(self, volume):\r\n        print(f\"Setting actual volume to {volume} mL...\")\r\n        response = self._send_command(0x10, 0x07D3, volume, 'float')\r\n        print(f\"Set actual volume response: {response.hex()}\")\r\n        \r\n    # Restore calibration defaults\r\n    def restore_defaults(self):\r\n        print(\"Restoring defaults...\")\r\n        response = self._send_command(0x06, 0x07D5, 0x0001, 'int')\r\n        print(f\"Restore defaults response: {response.hex()}\")\r\n        \r\n    # Perform micro adjustment (increase or decrease)\r\n    def micro_adjustment(self, increase=True):\r\n        action = \"Increase\" if increase else \"Decrease\"\r\n        print(f\"{action} micro adjustment...\")\r\n        data = 0x0001 if increase else 0x0000\r\n        response = self._send_command(0x06, 0x07D6, data, 'int')\r\n        print(f\"{action} micro adjustment response: {response.hex()}\")\r\n        \r\n#-----------------------------------------------------------------------#\r\n#   EXAMPLES ON HOW TO USE THE DEFINED CLASS TO CONTROL THE LABV PUMP   #\r\n#-----------------------------------------------------------------------#\r\n\r\nif __name__ == \"__main__\":\r\n    pump = LABV(port='COM6', address=1)  # Change port and address according to your setup\r\n    pump.connect()\r\n\r\n    try:\r\n        pump.set_pump_head(5)\r\n        pump.set_tube_size(16)\r\n        pump.set_direction(\"CW\")\r\n        pump.set_speed(50)\r\n        pump.set_flow_rate(50.0)\r\n        pump.set_back_suction_angle(0)\r\n        pump.set_full_speed_running(True)\r\n        pump.start_pump()\r\n\r\n    except Exception as e:\r\n        print(f\"An error occurred: {e}\")\r\n    finally:\r\n        pump.stop_pump()\r\n        pump.disconnect()\r\n</xmp>\n\t\t\t\t</code>\n\t\t\t</pre>\n\t\t</div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e0bca4 elementor-widget elementor-widget-text-editor\" data-id=\"2e0bca4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Diese Python-Bibliothek zur Steuerung der LabV Pumpenserie über das MODBUS RTU Protokoll ermöglicht eine präzise und automatisierte Regelung verschiedener Pumpenparameter wie Geschwindigkeit, Richtung, Pumpenkopf und tube Größe. Nutzer einer LabV Pumpe können diese nun problemlos in komplexe Arbeitsabläufe mit mehreren Geräten integrieren, wodurch die betriebliche Effizienz und Flexibilität gesteigert wird.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-679f305 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"679f305\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-71d5293\" data-id=\"71d5293\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-336c844 elementor-widget elementor-widget-heading\" data-id=\"336c844\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Fazit</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c5dacb0 elementor-widget elementor-widget-text-editor\" data-id=\"c5dacb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In diesem Blogbeitrag haben wir die LabV Schlauchpumpenserie vorgestellt und die Grundlagen für deren contrôle externe mittels Python über das MODBUS RTU Kommunikationsprotokoll untersucht. Wir hoffen, dass dieser Beitrag Forschern und Ingenieuren als wertvoller Leitfaden dient, die eine LabV Schlauchpumpe in ihre mikrofluidische Forschung und ihre Experimente einbinden möchten.</p><p><strong><em>🚨 </em></strong><em>Obwohl es Abweichungen zwischen den verschiedenen Serien von Innofluid Lab Pumpen gibt, möchten wir betonen, dass das Kommunikationsprotokoll nahezu unverändert bleibt. Unabhängig davon, ob Sie die LabF-Serie, die LabN-Serie oder eine andere verwenden, sind wir zuversichtlich, dass dieser Inhalt auch für Ihre zukünftigen Projekte von Nutzen sein wird.</em></p><p>Freut euch auf weitere Einblicke, Tutorials und praktische Anwendungsbeispiele in unseren kommenden Beiträgen. Bis dahin: Viel Spaß beim Pumpen und Programmieren 💻!</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17b2b7c elementor-widget elementor-widget-text-editor\" data-id=\"17b2b7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>📧 Bei Fragen oder Feedback können Sie uns gerne kontaktieren unter <a href=\"https://darwin-microfluidics.com/de/pages/kontakt\"><span style=\"font-weight: 400;\">support@darwin-microfluidics.com</span></a><span style=\"font-weight: 400;\">.</span></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97f1388 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"97f1388\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Brauchen Sie Hilfe bei Ihrem Mikrofluidik-Projekt?\"><a href=\"https://darwin-microfluidics.com/de/kontakt\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Kontaktieren Sie unsere Experten!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Brauchen Sie Hilfe bei Ihrem Mikrofluidik-Projekt?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Wir machen Mikrofluidik einfach für Sie!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Die LabV-Pumpenserie von Innofluid (früher bekannt als Shenchen Baoding) ist eine fortschrittliche Serie von Durchflussmess-Schlauchpumpen mit einem 4,3-Zoll-Farb-Touchscreen für eine intuitive Steuerung. Sie zeigt Durchflussdaten, Einstellungen und Systeminformationen gleichzeitig mit Animationen an...</p>\n","protected":false},"author":4,"featured_media":23931,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[24,33],"tags":[],"class_list":["post-23929","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-control","category-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Wie steuert man eine LabV Pumpe über das MODBUS-Protokoll? – Darwin Microfluidics</title>\n<meta name=\"description\" content=\"Erfahren Sie in unserem Benutzerhandbuch, wie Sie LabV Pumpen über das MODBUS RTU-Protokoll steuern. Vereinfachen Sie Ihre Pumpensteuerungsprozesse effektiv.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Wie steuert man eine LabV Pumpe über das MODBUS-Protokoll? – Darwin Microfluidics\">\n<meta property=\"og:description\" content=\"Erfahren Sie in unserem Benutzerhandbuch, wie Sie LabV Pumpen über das MODBUS RTU-Protokoll steuern. Vereinfachen Sie Ihre Pumpensteuerungsprozesse effektiv.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-06-10T12:50:28+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:25:03+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg\">\n\t<meta property=\"og:image:width\" content=\"640\">\n\t<meta property=\"og:image:height\" content=\"640\">\n\t<meta property=\"og:image:type\" content=\"image/jpeg\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"13 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"How to Control a LabV Pump Using the MODBUS Protocol ?\",\"datePublished\":\"2024-06-10T12:50:28+00:00\",\"dateModified\":\"2026-11-19T14:25:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\"},\"wordCount\":2410,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg\",\"articleSection\":[\"Flow control\",\"Guides &amp; tutorials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\",\"url\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\",\"name\":\"How to Control a LabV Pump Using the MODBUS Protocol ? - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg\",\"datePublished\":\"2024-06-10T12:50:28+00:00\",\"dateModified\":\"2026-11-19T14:25:03+00:00\",\"description\":\"Erfahren Sie in unserem Benutzerhandbuch, wie Sie LabV Pumpen über das MODBUS RTU-Protokoll steuern. Vereinfachen Sie Ihre Pumpensteuerungsprozesse effektiv.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg\",\"width\":640,\"height\":640,\"caption\":\"An image of the LabV-III Intelligent Flow Rate Peristaltic Pump with a white background.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Control a LabV Pump Using the MODBUS Protocol ?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Unser Blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/de\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Control a LabV Pump Using the MODBUS Protocol ? - Darwin Microfluidics","description":"Erfahren Sie in unserem Benutzerhandbuch, wie Sie LabV Pumpen über das MODBUS RTU-Protokoll steuern. Vereinfachen Sie Ihre Pumpensteuerungsprozesse effektiv.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/","og_locale":"en_US","og_type":"article","og_title":"How to Control a LabV Pump Using the MODBUS Protocol ? - Darwin Microfluidics","og_description":"Learn how to control LabV pumps using the MODBUS RTU protocol with our user guide. Simplify your pump control processes effectively.","og_url":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-06-10T12:50:28+00:00","article_modified_time":"2026-11-19T14:25:03+00:00","og_image":[{"width":640,"height":640,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","type":"image/jpeg"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"13 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"How to Control a LabV Pump Using the MODBUS Protocol ?","datePublished":"2024-06-10T12:50:28+00:00","dateModified":"2026-11-19T14:25:03+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/"},"wordCount":2410,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","articleSection":["Flow control","Guides &amp; tutorials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/","url":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/","name":"How to Control a LabV Pump Using the MODBUS Protocol ? - Darwin Microfluidics","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","datePublished":"2024-06-10T12:50:28+00:00","dateModified":"2026-11-19T14:25:03+00:00","description":"Erfahren Sie in unserem Benutzerhandbuch, wie Sie LabV Pumpen über das MODBUS RTU-Protokoll steuern. Vereinfachen Sie Ihre Pumpensteuerungsprozesse effektiv.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","width":640,"height":640,"caption":"An image of the LabV-III Intelligent Flow Rate Peristaltic Pump with a white background."},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"How to Control a LabV Pump Using the MODBUS Protocol ?"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Unser Blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/23929","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=23929"}],"version-history":[{"count":332,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/23929/revisions"}],"predecessor-version":[{"id":33685,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/23929/revisions/33685"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/23931"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=23929"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=23929"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=23929"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}