{"id":30438,"date":"2024-11-18T11:23:19","date_gmt":"2024-11-18T10:23:19","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=30438"},"modified":"2026-11-19T15:33:29","modified_gmt":"2026-11-19T14:33:29","slug":"ethylene-oxide-eto-sterilization-compatibility-chart","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/","title":{"rendered":"Ethylene Oxide (EtO) – Sterilization Compatibility Chart"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"30438\" class=\"elementor elementor-30438\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3e27249 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3e27249\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-40c422c\" data-id=\"40c422c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d7a1835 elementor-widget elementor-widget-text-editor\" data-id=\"d7a1835\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Ethylenoxid (EtO)</strong> ist eine weit verbreitete <strong>Sterilisationsmethode</strong> für hitze- und feuchtigkeitsempfindliche Materialien. Sie ist in medizinischen, biologischen und <strong>mikrofluidischen Anwendungen</strong> sehr beliebt, da sie eine effektive Sterilisation ermöglicht, ohne dass die Materialien hohen Temperaturen ausgesetzt werden.</p><p>Beim EtO-Verfahren werden Materialien in einer kontrollierten Kammer Ethylenoxidgas ausgesetzt. Dieses Gas dringt in das Material ein und zerstört die mikrobielle DNA, um die Sterilität zu gewährleisten. Da es sich um ein nicht-thermisches Verfahren handelt, eignet es sich ideal zur Sterilisation von Kunststoffen, Polymeren und elektronischen Bauteilen, die hohen Temperaturen oder einer Dampfsterilisation nicht standhalten können. Die EtO-Sterilisation ist zwar äußerst wirksam, doch ist aufgrund der Toxizität des EtO-Gases eine Belüftung nach der Sterilisation erforderlich, um Restgase zu entfernen.</p><p>Um Ingenieuren und Forschern dabei zu helfen, zu beurteilen, <span style=\"font-weight: 400;\">wie verschiedene Materialien auf eine Sterilisation mit Ethylenoxid reagieren</span>, enthält die folgende umfassende <a href=\"#chart\">Tabelle</a>, die aus verschiedenen Quellen – darunter <a href=\"https://www.qosina.com/\" target=\"_blank\" rel=\"noopener\">Qosina</a>, <a href=\"https://www.idex-hs.com/home\" target=\"_blank\" rel=\"noopener\">Idex</a> und <a href=\"https://www.industrialspec.com/\" target=\"_blank\" rel=\"noopener\">Industrial Specialties Mfg.</a> – zusammengestellt wurde, Angaben zur Verträglichkeit.</p><p>Nutzen Sie diese Tabelle, um fundierte Entscheidungen zu treffen und kontaminationsfreie Experimente sicherzustellen.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-252a3b0 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"252a3b0\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0281c9c\" data-id=\"0281c9c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-1e521f8 elementor-widget elementor-widget-text-editor\" data-id=\"1e521f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>💡 Der Schlüssel für die Kompatibilitätsbewertung bei der Sterilisation lautet wie folgt:</p><ul><li>Gut = Geringe bis keine Auswirkungen</li><li>Mäßig = Geringe bis moderate Auswirkungen</li><li>Schlecht = Moderate bis schwere Auswirkungen (Nicht empfohlen)</li></ul><p>🚨 <em>Diese Tabelle dient ausschließlich Informationszwecken und ist nicht als Garantie für die Materialleistung bei der Sterilisation oder anderen Anwendungen zu verstehen. Anwender sind selbst dafür verantwortlich, die Eignung von Materialien und Verfahren für ihre spezifischen Anwendungen unter Berücksichtigung technischer und rechtlicher Aspekte zu bewerten.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54d2f6a elementor-widget elementor-widget-heading\" data-id=\"54d2f6a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">🧪 Ethylenoxid: Sterilisations-<span style=\"font-size: 2rem;font-weight: var( --e-global-typography-primary-font-weight );letter-spacing: -0.16px\">Kompatibilitätstabelle</span><span style=\"color: var( --e-global-color-primary );font-family: var( --e-global-typography-primary-font-family ), Sans-serif;font-size: 2rem;font-weight: var( --e-global-typography-primary-font-weight );letter-spacing: -0.01rem\"></span><br></h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-853e020 elementor-widget elementor-widget-shortcode\" data-id=\"853e020\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"chart\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-94\" class=\"tablepress tablepress-id-94\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Material</th><th class=\"column-2\">Ethylenoxid (EtO)</th>\n</tr>\n</thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Aluminium</td><td class=\"column-2\">Schlecht</td>\n</tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Cyclo-Olefin-Copolymer (COC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Cyclo-Olefin-Polymer (COP)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Ethylen-Chlortrifluorethylen (ECTFE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Ethylen-Propylen-Dien-Kautschuk (EPDM)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Ethylen-Tetrafluorethylen (Tefzel – ETFE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Fluoriertes Ethylen-Propylen (FEP)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Polyethylen hoher Dichte (HDPE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Polypropylen hoher Dichte (HDPP)</td><td class=\"column-2\">N/A</td>\n</tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Hochtemperaturbeständiges Polycarbonat (PC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Linear Low Density Polyethylene (LLDP)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Low Density Polyethylene (LDPE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Neopren</td><td class=\"column-2\">Schlecht</td>\n</tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Olefinisches thermoplastisches Elastomer (TPO)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Perfluoralkoxy (PFA)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Perfluorelastomer (FFKM)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Polyamid (Nylon)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Polyamid-thermoplastisches Elastomer (TPA)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">Polycarbonat (PC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">Polychlortrifluorethylen (PCTFE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">Polydimethylsiloxan (PDMS)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">Polyetheretherketon (PEEK)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">Polyethylen (PE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">Polymethylmethacrylat (PMMA)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">Polyoxymethylen (Delrin)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">Polyphenylensulfid (PPS)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-28\">\n\t<td class=\"column-1\">Polyphenylsulfon (PPSU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-29\">\n\t<td class=\"column-1\">Polypropylen (PP)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-30\">\n\t<td class=\"column-1\">Polystyrol (PS)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-31\">\n\t<td class=\"column-1\">Polysulfon (PSU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-32\">\n\t<td class=\"column-1\">Polytetrafluorethylen (PTFE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-33\">\n\t<td class=\"column-1\">Polyurethan (PU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-34\">\n\t<td class=\"column-1\">Polyvinylchlorid (PVC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-35\">\n\t<td class=\"column-1\">Polyvinylchlorid (hart – PVC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-36\">\n\t<td class=\"column-1\">Polyvinylfluorid (PVF)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-37\">\n\t<td class=\"column-1\">Silikon</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-38\">\n\t<td class=\"column-1\">Edelstahl 316</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-39\">\n\t<td class=\"column-1\">Thermoplastisches Polyolefin (TPO)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-40\">\n\t<td class=\"column-1\">Thermoplastisches Polyurethan (TPU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-41\">\n\t<td class=\"column-1\">Ultrahoch molekulares Polyethylen (UHMWPE)</td><td class=\"column-2\">Gut</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-94 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-42eee4f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"42eee4f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7de82f6\" data-id=\"7de82f6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b366a70 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"b366a70\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Brauchen Sie Hilfe bei Ihrem Mikrofluidik-Projekt?\"><a href=\"https://darwin-microfluidics.com/de/kontakt\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Kontaktieren Sie unsere Experten!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Brauchen Sie Hilfe bei Ihrem Mikrofluidik-Projekt?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Wir machen Mikrofluidik einfach für Sie!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Ethylene oxide (EtO) is a widely used sterilization method, for heat-sensitive and moisture-sensitive materials. It is popular in medical, biological, and microfluidic applications because it effectively sterilizes without subjecting materials to high temperatures. The EtO process involves exposing materials to…</p>\n","protected":false},"author":4,"featured_media":30462,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[27,66,72],"tags":[],"class_list":["post-30438","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-chemical-compatibility","category-sterilization"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Ethylenoxid (EtO) – Tabelle zur Sterilisationsverträglichkeit</title>\n<meta name=\"description\" content=\"Entdecken Sie in dieser Tabelle die Materialkompatibilität mit einer Ethylenoxid-Sterilisation und stellen Sie eine effektive Sterilisation für Ihre Anforderungen sicher.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Ethylenoxid (EtO) – Tabelle zur Sterilisationsverträglichkeit\">\n<meta property=\"og:description\" content=\"Entdecken Sie in dieser Tabelle die Materialkompatibilität mit einer Ethylenoxid-Sterilisation und stellen Sie eine effektive Sterilisation für Ihre Anforderungen sicher.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-11-18T10:23:19+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:33:29+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Ethylene-Oxide-Sterilization-.png\">\n\t<meta property=\"og:image:width\" content=\"1024\">\n\t<meta property=\"og:image:height\" content=\"1024\">\n\t<meta property=\"og:image:type\" content=\"image/png\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"2 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"Ethylene Oxide (EtO) – Sterilization Compatibility Chart\",\"datePublished\":\"2024-11-18T10:23:19+00:00\",\"dateModified\":\"2026-11-19T14:33:29+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/\"},\"wordCount\":245,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Ethylene-Oxide-Sterilization-.png\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Chemical compatibility charts\",\"Sterilization\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/\",\"url\":\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/\",\"name\":\"Ethylene Oxide (EtO) – Sterilization Compatibility Chart\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Ethylene-Oxide-Sterilization-.png\",\"datePublished\":\"2024-11-18T10:23:19+00:00\",\"dateModified\":\"2026-11-19T14:33:29+00:00\",\"description\":\"Entdecken Sie in dieser Tabelle die Materialkompatibilität mit einer Ethylenoxid-Sterilisation und stellen Sie eine effektive Sterilisation für Ihre Anforderungen sicher.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Ethylene-Oxide-Sterilization-.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Ethylene-Oxide-Sterilization-.png\",\"width\":1024,\"height\":1024,\"caption\":\"Ethylene Oxide Sterilization\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Ethylene Oxide (EtO) – Sterilization Compatibility Chart\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Unser Blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/de\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Ethylene Oxide (EtO) – Sterilization Compatibility Chart","description":"Entdecken Sie in dieser Tabelle die Materialkompatibilität mit einer Ethylenoxid-Sterilisation und stellen Sie eine effektive Sterilisation für Ihre Anforderungen sicher.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/","og_locale":"en_US","og_type":"article","og_title":"Ethylene Oxide (EtO) – Sterilization Compatibility Chart","og_description":"Explore the compatibility of materials with Ethylene Oxide sterilization in this chart and ensure effective sterilization for your needs.","og_url":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-11-18T10:23:19+00:00","article_modified_time":"2026-11-19T14:33:29+00:00","og_image":[{"width":1024,"height":1024,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Ethylene-Oxide-Sterilization-.png","type":"image/png"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"2 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"Ethylene Oxide (EtO) – Sterilization Compatibility Chart","datePublished":"2024-11-18T10:23:19+00:00","dateModified":"2026-11-19T14:33:29+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/"},"wordCount":245,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Ethylene-Oxide-Sterilization-.png","articleSection":["Cell culture &amp; organ-on-chip","Chemical compatibility charts","Sterilization"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/","url":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/","name":"Ethylene Oxide (EtO) – Sterilization Compatibility Chart","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Ethylene-Oxide-Sterilization-.png","datePublished":"2024-11-18T10:23:19+00:00","dateModified":"2026-11-19T14:33:29+00:00","description":"Entdecken Sie in dieser Tabelle die Materialkompatibilität mit einer Ethylenoxid-Sterilisation und stellen Sie eine effektive Sterilisation für Ihre Anforderungen sicher.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Ethylene-Oxide-Sterilization-.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Ethylene-Oxide-Sterilization-.png","width":1024,"height":1024,"caption":"Ethylene Oxide Sterilization"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/ethylene-oxide-eto-sterilization-compatibility-chart/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Ethylene Oxide (EtO) – Sterilization Compatibility Chart"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Unser Blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Ethylene-Oxide-Sterilization-.png","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30438","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=30438"}],"version-history":[{"count":28,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30438/revisions"}],"predecessor-version":[{"id":30596,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30438/revisions/30596"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/30462"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=30438"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=30438"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=30438"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}