{"id":30477,"date":"2024-11-21T11:19:11","date_gmt":"2024-11-21T10:19:11","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=30477"},"modified":"2026-11-19T15:33:37","modified_gmt":"2026-11-19T14:33:37","slug":"electron-beam-sterilization-compatibility-chart","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/","title":{"rendered":"Electron Beam – Sterilization Compatibility Chart"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"30477\" class=\"elementor elementor-30477\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f20820b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f20820b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-587f0ef\" data-id=\"587f0ef\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e9832e8 elementor-widget elementor-widget-text-editor\" data-id=\"e9832e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Die Elektronenstrahl- (<strong>E-Beam-</strong>) Sterilisation</strong> ist ein häufig eingesetztes Verfahren zur Sterilisation von hitze- und feuchtigkeitsempfindlichen Materialien. Sie wird in medizinischen, biologischen und <strong>mikrofluidischen Anwendungen</strong> eingesetzt, da sie eine effektive Sterilisation ermöglicht, ohne die Materialien hohen Temperaturen auszusetzen.</p><p>Diese Methode basiert darauf, hochenergetische Elektronenstrahlen in einer kontrollierten Umgebung auf Materialien zu richten. Die Elektronen dringen in das Material ein, zerstören die mikrobielle DNA und gewährleisten so die Sterilität. Als nicht-thermisches Verfahren eignet sich die E-Beam-Sterilisation besonders für empfindliche Materialien, die der Hitze herkömmlicher Methoden wie Autoklavieren oder Dampfsterilisation nicht standhalten können. Es ist jedoch Vorsicht geboten, um eine Überbestrahlung zu vermeiden, da eine übermäßige Strahlung zu Materialabbau führen kann.</p><p>Um Ingenieuren und Forschern ein besseres Verständnis dafür zu vermitteln, wie sich verschiedene Materialien bei der Sterilisation mit Elektronenstrahlen verhalten, bietet die folgende umfassende <a href=\"#chart\">Tabelle</a>, die aus verschiedenen Quellen – darunter <a href=\"https://www.qosina.com/\" target=\"_blank\" rel=\"noopener\">Qosina</a>, <a href=\"https://www.idex-hs.com/home\" target=\"_blank\" rel=\"noopener\">Idex</a> und <a href=\"https://www.industrialspec.com/\" target=\"_blank\" rel=\"noopener\">Industrial Specialties Mfg.</a> – zusammengestellt wurde, Angaben zur Verträglichkeit.</p><p>Nutzen Sie diese Tabelle, um fundierte Entscheidungen zu treffen und kontaminationsfreie Experimente sicherzustellen.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-dc896a2 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"dc896a2\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9add8cb\" data-id=\"9add8cb\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-004f208 elementor-widget elementor-widget-text-editor\" data-id=\"004f208\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>💡 Der Schlüssel für die Kompatibilitätsbewertung bei der Sterilisation lautet wie folgt:</p><ul><li>Gut = Geringe bis keine Auswirkungen</li><li>Mäßig = Geringe bis moderate Auswirkungen</li><li>Schlecht = Moderate bis schwere Auswirkungen (Nicht empfohlen)</li></ul><p>🚨 <em>Diese Tabelle dient ausschließlich Informationszwecken und ist nicht als Garantie für die Materialleistung bei der Sterilisation oder anderen Anwendungen zu verstehen. Anwender sind selbst dafür verantwortlich, die Eignung von Materialien und Verfahren für ihre spezifischen Anwendungen unter Berücksichtigung technischer und rechtlicher Aspekte zu bewerten.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2dbb87 elementor-widget elementor-widget-heading\" data-id=\"a2dbb87\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">⚡ Elektronenstrahl: Tabelle zur Sterilisierbarkeit</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2dfd251 elementor-widget elementor-widget-shortcode\" data-id=\"2dfd251\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"chart\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-99\" class=\"tablepress tablepress-id-99\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Material</th><th class=\"column-2\">Elektronenstrahl</th>\n</tr>\n</thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Aluminium</td><td class=\"column-2\">N/A</td>\n</tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Cyclo-Olefin-Copolymer (COC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Cyclo-Olefin-Polymer (COP)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Ethylen-Chlortrifluorethylen (ECTFE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Ethylen-Propylen-Dien-Kautschuk (EPDM)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Ethylen-Tetrafluorethylen (Tefzel – ETFE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Fluoriertes Ethylen-Propylen (FEP)</td><td class=\"column-2\">Mittel</td>\n</tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Polyethylen hoher Dichte (HDPE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Polypropylen hoher Dichte (HDPP)</td><td class=\"column-2\">N/A</td>\n</tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Hochtemperaturbeständiges Polycarbonat (PC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Linear Low Density Polyethylene (LLDP)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Low Density Polyethylene (LDPE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Neopren</td><td class=\"column-2\">N/A</td>\n</tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Olefinisches thermoplastisches Elastomer (TPO)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Perfluoralkoxy (PFA)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Perfluorelastomer (FFKM)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Polyamid (Nylon)</td><td class=\"column-2\">Mittel</td>\n</tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Polyamid-thermoplastisches Elastomer (TPA)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">Polycarbonat (PC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">Polychlortrifluorethylen (PCTFE)</td><td class=\"column-2\">Mittel</td>\n</tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">Polydimethylsiloxan (PDMS)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">Polyetheretherketon (PEEK)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">Polyethylen (PE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">Polymethylmethacrylat (PMMA)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">Polyoxymethylen (Delrin)</td><td class=\"column-2\">Schlecht</td>\n</tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">Polyphenylensulfid (PPS)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-28\">\n\t<td class=\"column-1\">Polyphenylsulfon (PPSU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-29\">\n\t<td class=\"column-1\">Polypropylen (PP)</td><td class=\"column-2\">Mittel</td>\n</tr>\n<tr class=\"row-30\">\n\t<td class=\"column-1\">Polystyrol (PS)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-31\">\n\t<td class=\"column-1\">Polysulfon (PSU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-32\">\n\t<td class=\"column-1\">Polytetrafluorethylen (PTFE)</td><td class=\"column-2\">Schlecht</td>\n</tr>\n<tr class=\"row-33\">\n\t<td class=\"column-1\">Polyurethan (PU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-34\">\n\t<td class=\"column-1\">Polyvinylchlorid (PVC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-35\">\n\t<td class=\"column-1\">Polyvinylchlorid (hart – PVC)</td><td class=\"column-2\">Mittel</td>\n</tr>\n<tr class=\"row-36\">\n\t<td class=\"column-1\">Polyvinylfluorid (PVF)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-37\">\n\t<td class=\"column-1\">Silikon</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-38\">\n\t<td class=\"column-1\">Edelstahl 316</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-39\">\n\t<td class=\"column-1\">Thermoplastisches Polyolefin (TPO)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-40\">\n\t<td class=\"column-1\">Thermoplastisches Polyurethan (TPU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-41\">\n\t<td class=\"column-1\">Ultrahoch molekulares Polyethylen (UHMWPE)</td><td class=\"column-2\">Gut</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-99 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ab72714 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ab72714\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9ec0016\" data-id=\"9ec0016\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6fdcce5 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"6fdcce5\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Brauchen Sie Hilfe bei Ihrem Mikrofluidik-Projekt?\"><a href=\"https://darwin-microfluidics.com/de/kontakt\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Kontaktieren Sie unsere Experten!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Brauchen Sie Hilfe bei Ihrem Mikrofluidik-Projekt?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Wir machen Mikrofluidik einfach für Sie!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Die Elektronenstrahl-Sterilisation (E-Beam-Sterilisation) ist eine häufig genutzte Technik zur Sterilisation hitze- und feuchtigkeitsempfindlicher Materialien. Sie wird in medizinischen, biologischen und mikrofluidischen Anwendungen eingesetzt, da sie effektiv sterilisiert, ohne die Materialien hohen Temperaturen auszusetzen. Diese Methode funktioniert durch...</p>\n","protected":false},"author":4,"featured_media":30581,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[27,66,72],"tags":[],"class_list":["post-30477","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-chemical-compatibility","category-sterilization"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Elektronenstrahl – Tabelle zur Sterilisationsverträglichkeit</title>\n<meta name=\"description\" content=\"Entdecken Sie die Kompatibilitätstabelle für die Elektronenstrahlsterilisation, um zu erfahren, welche Materialien für eine sichere und effektive E-Beam-Sterilisation geeignet sind.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Elektronenstrahl – Tabelle zur Sterilisationsverträglichkeit\">\n<meta property=\"og:description\" content=\"Entdecken Sie die Kompatibilitätstabelle für die Elektronenstrahlsterilisation, um zu erfahren, welche Materialien für eine sichere und effektive E-Beam-Sterilisation geeignet sind.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-11-21T10:19:11+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:33:37+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization-1024x585.png\">\n\t<meta property=\"og:image:width\" content=\"1024\">\n\t<meta property=\"og:image:height\" content=\"585\">\n\t<meta property=\"og:image:type\" content=\"image/png\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"2 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"Electron Beam – Sterilization Compatibility Chart\",\"datePublished\":\"2024-11-21T10:19:11+00:00\",\"dateModified\":\"2026-11-19T14:33:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\"},\"wordCount\":247,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Chemical compatibility charts\",\"Sterilization\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\",\"url\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\",\"name\":\"Electron Beam – Sterilization Compatibility Chart\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png\",\"datePublished\":\"2024-11-21T10:19:11+00:00\",\"dateModified\":\"2026-11-19T14:33:37+00:00\",\"description\":\"Entdecken Sie die Kompatibilitätstabelle für die Elektronenstrahlsterilisation, um zu erfahren, welche Materialien für eine sichere und effektive E-Beam-Sterilisation geeignet sind.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png\",\"width\":1792,\"height\":1024,\"caption\":\"Electron beam (e-beam) sterilization\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electron Beam – Sterilization Compatibility Chart\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Unser Blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/de\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Electron Beam – Sterilization Compatibility Chart","description":"Entdecken Sie die Kompatibilitätstabelle für die Elektronenstrahlsterilisation, um zu erfahren, welche Materialien für eine sichere und effektive E-Beam-Sterilisation geeignet sind.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/","og_locale":"en_US","og_type":"article","og_title":"Electron Beam – Sterilization Compatibility Chart","og_description":"Discover the Electron Beam Sterilization Compatibility Chart to see which materials are suitable for safe and effective e-beam sterilization.","og_url":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-11-21T10:19:11+00:00","article_modified_time":"2026-11-19T14:33:37+00:00","og_image":[{"width":1024,"height":585,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization-1024x585.png","type":"image/png"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"2 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"Electron Beam – Sterilization Compatibility Chart","datePublished":"2024-11-21T10:19:11+00:00","dateModified":"2026-11-19T14:33:37+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/"},"wordCount":247,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png","articleSection":["Cell culture &amp; organ-on-chip","Chemical compatibility charts","Sterilization"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/","url":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/","name":"Electron Beam – Sterilization Compatibility Chart","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png","datePublished":"2024-11-21T10:19:11+00:00","dateModified":"2026-11-19T14:33:37+00:00","description":"Entdecken Sie die Kompatibilitätstabelle für die Elektronenstrahlsterilisation, um zu erfahren, welche Materialien für eine sichere und effektive E-Beam-Sterilisation geeignet sind.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png","width":1792,"height":1024,"caption":"Electron beam (e-beam) sterilization"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Electron Beam – Sterilization Compatibility Chart"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Unser Blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30477","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=30477"}],"version-history":[{"count":19,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30477/revisions"}],"predecessor-version":[{"id":30587,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30477/revisions/30587"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/30581"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=30477"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=30477"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=30477"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}