{"id":30482,"date":"2024-11-21T10:40:02","date_gmt":"2024-11-21T09:40:02","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=30482"},"modified":"2026-11-19T15:33:40","modified_gmt":"2026-11-19T14:33:40","slug":"gamma-irradiation-sterilization-compatibility-chart","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/","title":{"rendered":"Gamma Irradiation – Sterilization Compatibility Chart"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"30482\" class=\"elementor elementor-30482\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-40a790d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"40a790d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0d74268\" data-id=\"0d74268\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-771b747 elementor-widget elementor-widget-text-editor\" data-id=\"771b747\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Gammabestrahlung (γ-Bestrahlung)</strong> ist eine äußerst effektive <strong>Sterilisationsmethode</strong>, die sich besonders für hitze- und feuchtigkeitsempfindliche Materialien eignet. Sie wird häufig in medizinischen, biologischen und <strong>mikrofluidischen Anwendungen</strong> eingesetzt, da sie Sterilität gewährleistet, ohne dass die Materialien hohen Temperaturen ausgesetzt werden.</p><p>Während der Gammabestrahlung werden Materialien in einer kontrollierten Umgebung hochenergetischen Gammastrahlen ausgesetzt. Diese Strahlen durchdringen das Material und zerstören die DNA von Mikroorganismen, wodurch die Gegenstände effektiv sterilisiert werden. Da es sich um ein nicht-thermisches Verfahren handelt, eignet sich die Gammabestrahlung hervorragend zur Sterilisation empfindlicher Materialien, die keine hohen Temperaturen oder dampfbasierte Sterilisationsprozesse vertragen. Trotz ihrer Wirksamkeit ist eine sorgfältige Handhabung nach der Bestrahlung unerlässlich, um einen durch die Strahleneinwirkung eventuell verursachten Materialabbau zu minimieren.</p><p>Um Ingenieuren und Forschern bei der Bewertung des Verhaltens verschiedener Werkstoffe unter Gammastrahlung zu helfen, bietet die folgende umfassende <a href=\"#chart\">Tabelle</a>, die auf Quellen wie <a href=\"https://www.qosina.com/\" target=\"_blank\" rel=\"noopener\">Qosina</a>, <a href=\"https://www.idex-hs.com/home\" target=\"_blank\" rel=\"noopener\">Idex</a> und <a href=\"https://www.industrialspec.com/\" target=\"_blank\" rel=\"noopener\">Industrial Specialties Mfg.</a> basiert, Angaben zur Verträglichkeit.</p><p>Nutzen Sie diese Tabelle, um fundierte Entscheidungen zu treffen und kontaminationsfreie Experimente sicherzustellen.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c02c550 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c02c550\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-473b577\" data-id=\"473b577\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-bb151e7 elementor-widget elementor-widget-text-editor\" data-id=\"bb151e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>💡 Der Schlüssel für die Kompatibilitätsbewertung bei der Sterilisation lautet wie folgt:</p><ul><li>Gut = Geringe bis keine Auswirkungen</li><li>Mäßig = Geringe bis moderate Auswirkungen</li><li>Schlecht = Moderate bis schwere Auswirkungen (Nicht empfohlen)</li></ul><p>🚨 <em>Diese Tabelle dient ausschließlich Informationszwecken und ist nicht als Garantie für die Materialleistung bei der Sterilisation oder anderen Anwendungen zu verstehen. Anwender sind selbst dafür verantwortlich, die Eignung von Materialien und Verfahren für ihre spezifischen Anwendungen unter Berücksichtigung technischer und rechtlicher Aspekte zu bewerten.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6265113 elementor-widget elementor-widget-heading\" data-id=\"6265113\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">☢️ Gammabestrahlung: Sterilisationskompatibilitätstabelle</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73d3c15 elementor-widget elementor-widget-shortcode\" data-id=\"73d3c15\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"chart\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-98\" class=\"tablepress tablepress-id-98\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Material</th><th class=\"column-2\">Gammabestrahlung</th>\n</tr>\n</thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Aluminium</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Cyclo-Olefin-Copolymer (COC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Cyclo-Olefin-Polymer (COP)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Ethylen-Chlortrifluorethylen (ECTFE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Ethylen-Propylen-Dien-Kautschuk (EPDM)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Ethylen-Tetrafluorethylen (Tefzel – ETFE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Fluoriertes Ethylen-Propylen (FEP)</td><td class=\"column-2\">Mittel</td>\n</tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Polyethylen hoher Dichte (HDPE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Polypropylen hoher Dichte (HDPP)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Hochtemperaturbeständiges Polycarbonat (PC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Linear Low Density Polyethylene (LLDP)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Low Density Polyethylene (LDPE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Neopren</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Olefinisches thermoplastisches Elastomer (TPO)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Perfluoralkoxy (PFA)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Perfluorelastomer (FFKM)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Polyamid (Nylon)</td><td class=\"column-2\">Mittel</td>\n</tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Polyamid-thermoplastisches Elastomer (TPA)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">Polycarbonat (PC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">Polychlortrifluorethylen (PCTFE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">Polydimethylsiloxan (PDMS)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">Polyetheretherketon (PEEK)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">Polyethylen (PE)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">Polymethylmethacrylat (PMMA)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">Polyoxymethylen (Delrin)</td><td class=\"column-2\">Schlecht</td>\n</tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">Polyphenylensulfid (PPS)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-28\">\n\t<td class=\"column-1\">Polyphenylsulfon (PPSU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-29\">\n\t<td class=\"column-1\">Polypropylen (PP)</td><td class=\"column-2\">Mittel</td>\n</tr>\n<tr class=\"row-30\">\n\t<td class=\"column-1\">Polystyrol (PS)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-31\">\n\t<td class=\"column-1\">Polysulfon (PSU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-32\">\n\t<td class=\"column-1\">Polytetrafluorethylen (PTFE)</td><td class=\"column-2\">Schlecht</td>\n</tr>\n<tr class=\"row-33\">\n\t<td class=\"column-1\">Polyurethan (PU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-34\">\n\t<td class=\"column-1\">Polyvinylchlorid (PVC)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-35\">\n\t<td class=\"column-1\">Polyvinylchlorid (hart – PVC)</td><td class=\"column-2\">Mittel</td>\n</tr>\n<tr class=\"row-36\">\n\t<td class=\"column-1\">Polyvinylfluorid (PVF)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-37\">\n\t<td class=\"column-1\">Silikon</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-38\">\n\t<td class=\"column-1\">Edelstahl 316</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-39\">\n\t<td class=\"column-1\">Thermoplastisches Polyolefin (TPO)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-40\">\n\t<td class=\"column-1\">Thermoplastisches Polyurethan (TPU)</td><td class=\"column-2\">Gut</td>\n</tr>\n<tr class=\"row-41\">\n\t<td class=\"column-1\">Ultrahoch molekulares Polyethylen (UHMWPE)</td><td class=\"column-2\">Gut</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-98 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4b0cce6 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4b0cce6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-fd6a542\" data-id=\"fd6a542\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-100b387 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"100b387\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Brauchen Sie Hilfe bei Ihrem Mikrofluidik-Projekt?\"><a href=\"https://darwin-microfluidics.com/de/kontakt\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Kontaktieren Sie unsere Experten!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Brauchen Sie Hilfe bei Ihrem Mikrofluidik-Projekt?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Wir machen Mikrofluidik einfach für Sie!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Gamma Irradiation (γ-irradiation) is a highly effective sterilization method, particularly suitable for materials that are sensitive to both heat and moisture. It is commonly used in medical, biological, and microfluidic applications because it ensures sterility without subjecting materials to high…</p>\n","protected":false},"author":4,"featured_media":30568,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[27,66,72],"tags":[],"class_list":["post-30482","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-chemical-compatibility","category-sterilization"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Gamma-Bestrahlung – Tabelle zur Sterilisationsverträglichkeit</title>\n<meta name=\"description\" content=\"Werfen Sie einen Blick auf die Kompatibilitätstabelle für Gammabestrahlung, um zu erfahren, welche Materialien für Gammasterilisationsverfahren geeignet sind.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Gamma-Bestrahlung – Tabelle zur Sterilisationsverträglichkeit\">\n<meta property=\"og:description\" content=\"Werfen Sie einen Blick auf die Kompatibilitätstabelle für Gammabestrahlung, um zu erfahren, welche Materialien für Gammasterilisationsverfahren geeignet sind.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-11-21T09:40:02+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:33:40+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization-1024x585.png\">\n\t<meta property=\"og:image:width\" content=\"1024\">\n\t<meta property=\"og:image:height\" content=\"585\">\n\t<meta property=\"og:image:type\" content=\"image/png\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"2 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"Gamma Irradiation – Sterilization Compatibility Chart\",\"datePublished\":\"2024-11-21T09:40:02+00:00\",\"dateModified\":\"2026-11-19T14:33:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\"},\"wordCount\":257,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Chemical compatibility charts\",\"Sterilization\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\",\"url\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\",\"name\":\"Gamma Irradiation – Sterilization Compatibility Chart\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png\",\"datePublished\":\"2024-11-21T09:40:02+00:00\",\"dateModified\":\"2026-11-19T14:33:40+00:00\",\"description\":\"Werfen Sie einen Blick auf die Kompatibilitätstabelle für Gammabestrahlung, um zu erfahren, welche Materialien für Gammasterilisationsverfahren geeignet sind.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png\",\"width\":1792,\"height\":1024,\"caption\":\"Gamma irradiation sterilization\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Gamma Irradiation – Sterilization Compatibility Chart\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Unser Blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/de\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Gamma Irradiation – Sterilization Compatibility Chart","description":"Werfen Sie einen Blick auf die Kompatibilitätstabelle für Gammabestrahlung, um zu erfahren, welche Materialien für Gammasterilisationsverfahren geeignet sind.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/","og_locale":"en_US","og_type":"article","og_title":"Gamma Irradiation – Sterilization Compatibility Chart","og_description":"Check out the Gamma Irradiation Sterilization Compatibility Chart to learn which materials are compatible with gamma sterilization processes.","og_url":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-11-21T09:40:02+00:00","article_modified_time":"2026-11-19T14:33:40+00:00","og_image":[{"width":1024,"height":585,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization-1024x585.png","type":"image/png"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"2 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"Gamma Irradiation – Sterilization Compatibility Chart","datePublished":"2024-11-21T09:40:02+00:00","dateModified":"2026-11-19T14:33:40+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/"},"wordCount":257,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png","articleSection":["Cell culture &amp; organ-on-chip","Chemical compatibility charts","Sterilization"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/","url":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/","name":"Gamma Irradiation – Sterilization Compatibility Chart","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png","datePublished":"2024-11-21T09:40:02+00:00","dateModified":"2026-11-19T14:33:40+00:00","description":"Werfen Sie einen Blick auf die Kompatibilitätstabelle für Gammabestrahlung, um zu erfahren, welche Materialien für Gammasterilisationsverfahren geeignet sind.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png","width":1792,"height":1024,"caption":"Gamma irradiation sterilization"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Gamma Irradiation – Sterilization Compatibility Chart"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Unser Blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30482","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=30482"}],"version-history":[{"count":19,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30482/revisions"}],"predecessor-version":[{"id":30593,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30482/revisions/30593"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/30568"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=30482"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=30482"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=30482"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}