{"id":13907,"date":"2023-02-07T11:12:30","date_gmt":"2023-02-07T10:12:30","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=13907"},"modified":"2024-10-23T17:22:38","modified_gmt":"2024-10-23T15:22:38","slug":"on-chip-pump-and-valve-in-microfluidics","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/","title":{"rendered":"On-chip pump and valve in microfluidics"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"13907\" class=\"elementor elementor-13907\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2d1adb elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2d1adb\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-31b841ef\" data-id=\"31b841ef\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6608cec8 elementor-widget elementor-widget-text-editor\" data-id=\"6608cec8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p></p>\n<p class=\"has-text-align-left wp-block-paragraph\">La aparición de la microfluídica ha llevado a la integración de dispositivos micro y nanofluídicos en numerosas aplicaciones, como el análisis biomédico y químico.</p>\n<p>Los dispositivos micro y nanofluídicos con canales muy pequeños (tamaño en µm) ofrecen ventajas interesantes en términos de menor consumo de muestras y mayor sensibilidad gracias al uso de volúmenes reducidos (micro/nanolitros), lo que permite obtener una relación superficie/volumen bastante grande. El desarrollo de las nanotecnologías y de los sistemas micro/nanoelectromecánicos (MEMS, NEMS) también facilita enormemente la fabricación e integración de componentes microelectrónicos.</p>\n<p></p>\n<p class=\"wp-block-paragraph\">En esta revisión, analizaremos diferentes métodos para integrar bombas y válvulas en un chip microfluídico mediante varios ejemplos extraídos de la literatura.</p>\n<p></p>\n<h2 class=\"wp-block-heading\">Fabricación de un sistema de microválvulas manuales de PDMS </h2>\n<p></p>\n<p class=\"wp-block-paragraph\">Las válvulas utilizadas en microfluídica se basan, por lo general, en los siguientes tipos de estructuras de control: mecánica operativa, neumática, electrocinética, cambio de fase o aplicación de una fuerza externa.<br/>Existen dos tipos de válvulas en función de su estado: válvulas activas y pasivas. Su clasificación dependerá, por tanto, de su asociación con piezas móviles mecánicas o no mecánicas.</p>\n<p></p>\n<p class=\"wp-block-paragraph\">En este ejemplo, los investigadores optaron por fabricar su propia válvula. El principio de funcionamiento de la válvula se basa en una estructura mecánica (hecha de materiales de Plexiglas®) y materiales flexibles (PDMS), tal como se describe en la figura 1.</p>\n<p>La válvula consta de una parte activa que incluye un <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microcanal</a> y una película delgada de PDMS (figuras 1(a) y 1(b)). La película de PDMS se fabricó con un espesor de 100 µm y se adhirió a la parte superior del canal mediante funcionalización en un limpiador de plasma. El <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microcanal</a> se fabricó en PDMS con unas dimensiones de 1 × 0,05 × 10 mm utilizando una técnica de <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/soft-lithography-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">litografía blanda</a>. </p>\n<p></p>\n<p class=\"wp-block-paragraph\">La estructura mecánica para abrir y cerrar el flujo se combinó con dos componentes: un tornillo (~3 mm de diámetro, con una rosca de 0,5 mm) guiado a través de un orificio roscado en una placa de Plexiglas, la cual a su vez está fijada a una segunda placa; y una pieza de PDMS (~2,5 mm) más pequeña que el orificio del tornillo que se mueve libremente en su interior. La pieza de PDMS ayuda a que la cabeza del tornillo no agriete la película de PDMS durante el proceso de trabajo.</p>\n<p></p>\n<figure class=\"wp-block-image size-full is-resized\"><img fetchpriority=\"high\" decoding=\"async\" class=\"wp-image-13908\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system.webp\" alt=\"diseño de 4 válvulas en el chip de PDMS y termoplástico\" width=\"650\" height=\"403\">\n<p>&nbsp;</p>\n<figcaption class=\"wp-element-caption\"><em>Figura 1: Diseño del sistema multiválvula para controlar los caudales de entrada al sistema microfluídico. (a) y (b): secciones transversales de las válvulas de conmutación (en el control de un caudal); (c) y (d): disposición y construcción del sistema de control de múltiples caudales. Extraído de Le T N et al., 2020, Adv. Polym. Technol.</em>&nbsp;</figcaption>\n</figure>\n<p></p>\n<p class=\"wp-block-paragraph\">En cuanto a la válvula, hay dos estructuras principales compuestas por piezas de « PDMS » y Plexiglas®, tal y como se muestra en la figura 1(d). La pieza PDMS contiene la parte con los canales (para válvulas de canal) y una placa intermedia PDMS con varios orificios del mismo diámetro que los tornillos. Ambas estructuras mecánicas se han fabricado en Plexiglas®; la primera de ellas se ha diseñado con orificios roscados, mientras que la segunda es un soporte inferior que, combinado con la primera (a modo de abrazadera), permite fijar todos los elementos de las estructuras del sistema de válvulas.</p>\n<p></p>\n<p class=\"wp-block-paragraph\">Para obtener más información sobre este diseño, te invitamos a leer el artículo <em><u><a href=\"https://www.hindawi.com/journals/apt/2020/2460212/\">Le T N et al. 2020, Adv. Polym. Technol.</a></u></em></p>\n<p></p>\n<p class=\"wp-block-paragraph\">Hay que reconocer que este método es ingenioso, práctico y económico, pero no se puede aplicar en todos los casos, sobre todo cuando hay un tornillo. De hecho, algunas aplicaciones exigen un alto grado de integración y rendimiento. Por eso, veremos en otro ejemplo qué se puede hacer en la fase de creación de prototipos.</p>\n<p></p>\n<h2 class=\"wp-block-heading\">Corazón/cáncer integrado en un chip para reproducir los efectos secundarios de los medicamentos anticancerosos <em>in vitro</em> </h2>\n<p></p>\n<p class=\"wp-block-paragraph\">Durante mucho tiempo, los laboratorios en un chip se han utilizado principalmente para análisis y detección bioquímica, pero recientemente también se han empleado para el diagnóstico.</p>\n<p>Por lo tanto, a medida que evolucionan las tecnologías, el avance hacia un sistema de diagnóstico portátil se está volviendo posible. Además de los sistemas microfluídicos, se requieren bombas, electrodos, válvulas y campos eléctricos. Todo esto puede lograrse mediante el uso de microelectrónica integrada.</p>\n<p></p>\n<p class=\"wp-block-paragraph\">En este ejemplo, el equipo desarrolló un dispositivo microfluídico —un corazón/cáncer integrado en un chip (iHCC, por sus siglas en inglés)— utilizando células cardíacas humanas sanas (hCMs) y células de cáncer de hígado (HepG2) para replicar los efectos secundarios de un medicamento contra el cáncer, la doxorrubicina (DXR), logrando cultivos individuales de células de diferentes tejidos en un único dispositivo con tres juegos de bucles de circulación sanguínea artificial; además, la tecnología de microfabricación para microválvulas y una bomba proporcionan una manipulación precisa de los fluidos.</p>\n<p></p>\n<p class=\"wp-block-paragraph\">Para la fabricación del iHCC, el equipo decidió utilizar PDMS, especialmente por su biocompatibilidad, su buena permeabilidad a los gases y su excelente transparencia óptica.</p>\n<p></p>\n<p class=\"wp-block-paragraph\">La denominada «capa de infusión» contiene dos cámaras de cultivo celular (de 2,1 mm de ancho y 220 mm de alto), que son suficientes para proporcionar los factores de crecimiento necesarios y el fármaco anticancerígeno, así como para reducir la tensión de cizallamiento. </p>\n<p>Se han creado microcanales para interconectar las dos cámaras de cultivo celular (de 150 µm de ancho y 45 µm de alto) mediante orificios de entrada y salida.</p>\n<p></p>\n<p class=\"wp-block-paragraph\">La denominada «capa de control», que también está formada por una membrana de PDMS fina y flexible (200 x 200 µm² y 20 µm de grosor), contiene válvulas que permiten el cultivo independiente de dos tipos de células sin contaminación cruzada, así como un sistema de control de flujo ( microbombas ) para el control preciso del medio caudal.</p>\n<p></p>\n<p class=\"wp-block-paragraph\">Por lo tanto, este dispositivo incluye tres conjuntos de dos cámaras de cultivo celular con un circuito de circulación cerrado para permitir tres tratamientos celulares diferentes pero simultáneos dentro del mismo dispositivo (Figura 2).</p>\n<p></p>\n<p class=\"wp-block-paragraph\"><em>Para obtener más información sobre este diseño, te invitamos a leer este artículo de<a href=\"https://pubs.rsc.org/en/content/articlepdf/2017/ra/c7ra07716e\" target=\"_blank\" rel=\"noreferrer noopener\">Kamei K et al., 2017, RSC Adv.</a> </em></p>\n<p></p>\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" width=\"1024\" height=\"428\" class=\"wp-image-13909\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cell_culture_chambers_with_a_medium_circulation_system_mimics_the_blood_circulatory_system-1024x428.webp\" alt=\"Las cámaras de cultivo celular con un sistema de circulación de medios imitan el sistema circulatorio sanguíneo\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cell_culture_chambers_with_a_medium_circulation_system_mimics_the_blood_circulatory_system-1024x428.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cell_culture_chambers_with_a_medium_circulation_system_mimics_the_blood_circulatory_system-300x125.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cell_culture_chambers_with_a_medium_circulation_system_mimics_the_blood_circulatory_system-768x321.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cell_culture_chambers_with_a_medium_circulation_system_mimics_the_blood_circulatory_system.webp 1048w\" sizes=\"(max-width: 1024px) 100vw, 1024px\">\n<p>&nbsp;</p>\n<figcaption class=\"wp-element-caption\"><em>Figura 2: Las cámaras de cultivo celular con un sistema de circulación de medios imitan el sistema circulatorio sanguíneo que interconecta varias células tisulares. Las válvulas integradas (rojas o negras según la configuración) permiten un control preciso de los fluidos, así como la introducción de células/reactivos. Una bomba neumática (amarilla o negra según la configuración) proporciona la circulación del medio dentro de un conjunto de dos cámaras de cultivo celular. Extraído de Kamei K et al 2017 RSC Adv.</em></figcaption>\n</figure>\n<p></p>\n<p class=\"wp-block-paragraph\">Darwin Microfluidics cuenta con una amplia gama de microválvulas y micropiezas para fabricar este tipo de prototipos microfluídicos. Nuestros expertos han seleccionado para usted los productos que mejor se adaptan a su aplicación en la siguiente tabla.</p>\n<p></p>\n<figure class=\"wp-block-table\">\n<table>\n<tbody>\n<tr>\n<td> Tipo de producto</td>\n<td>Tamaño</td>\n<td>Enlaces del sitio web de Darwin Microfluidics</td>\n</tr>\n<tr>\n<td>Válvula whisper de 2/2 o 3/2 vías Tipo 6724 de Bürkert</td>\n<td>8,9 mm de ancho</td>\n<td><a href=\"https://darwin-microfluidics.com/es/resultados-de-busqueda?q=2%2F2%20or%203%2F2%20Way%20Whisper%20Valve%20Type%206724%20from%20B%C3%BCrkert\">https://darwin-microfluidics.com/collections/microfluidic-valves/products/2-2-or-3-2-way-whisper-valve-type-6724</a></td>\n</tr>\n<tr>\n<td>Microválvula whisper microfluídica de 2/2 vías Tipo 6712 de Bürkert</td>\n<td>18,2 x 7,2 x 7 mm</td>\n<td><a href=\"https://darwin-microfluidics.com/es/productos/2-2-way-microfluidic-whisper-valve-type-6712/\">https://darwin-microfluidics.com/collections/microfluidic-valves/products/microfluidic-minimum-volume-solenoid-valve-burkert-type-6712</a></td>\n</tr>\n<tr>\n<td>Microválvula microfluídica en miniatura de 2/2 vías de Memetis</td>\n<td>20 x 5 x 7 mm</td>\n<td><a href=\"https://darwin-microfluidics.com/es/collections/valvulas-microfluidicas/productos/2-2-way-microfluidic-miniature-valve\">https://darwin-microfluidics.com/collections/microfluidic-valves/products/2-2-way-microfluidic-miniature-valve</a></td>\n</tr>\n<tr>\n<td>Micropiezas de la serie BP7 de Bartels</td>\n<td>30 x 15 x 3,8 mm</td>\n<td><a href=\"https://darwin-microfluidics.com/es/productos/bartels-bp7-micropump/\">https://darwin-microfluidics.com/products/bartels-bp7-micropump</a></td>\n</tr>\n</tbody>\n</table>\n</figure>\n<p></p>\n<p class=\"wp-block-paragraph\">Con esta revisión, dispone de todas las claves para iniciarse en la fabricación de prototipos microfluídicos. ¡Los expertos de Darwin Microfluidics quedan a su servicio para asesorarle!</p>\n<p></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b2561b elementor-widget elementor-widget-global elementor-global-18307 elementor-widget-pix-promo-box\" data-id=\"8b2561b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Valves_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"¿QUIERES SIMPLIFICAR LA CONFIGURACIÓN DE TU LABORATORIO?\"><a href=\"https://darwin-microfluidics.com/es/collections/valvulas-microfluidicas\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">¡Descubra nuestra selección!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">¿QUIERES SIMPLIFICAR LA CONFIGURACIÓN DE TU LABORATORIO?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>¡Descubra cómo nuestras válvulas microfluídicas ofrecen un control preciso sobre la dinámica de fluidos, garantizando un rendimiento óptimo!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>El surgimiento de la microfluídica ha propiciado la integración de dispositivos microfluídicos y nanofluídicos en numerosas aplicaciones, como el análisis biomédico y químico. En esta revisión, analizaremos diferentes métodos para integrar bombas y válvulas en un chip microfluídico a través de diversos ejemplos extraídos de la literatura científica.</p>\n","protected":false},"author":3,"featured_media":13908,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[24,21],"tags":[],"class_list":["post-13907","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-control","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Bomba y válvula en el chip en microfluídica - Darwin Microfluidics</title>\n<meta name=\"description\" content=\"En esta revisión, conocerá diferentes métodos para integrar bombas y válvulas en un chip microfluídico a través de varios ejemplos.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Bomba y válvula en el chip en microfluídica - Darwin Microfluidics\">\n<meta property=\"og:description\" content=\"En esta revisión, conocerá diferentes métodos para integrar bombas y válvulas en un chip microfluídico a través de varios ejemplos.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-07T10:12:30+00:00\">\n<meta property=\"article:modified_time\" content=\"2024-10-23T15:22:38+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system-e1677593149673.webp\">\n\t<meta property=\"og:image:width\" content=\"470\">\n\t<meta property=\"og:image:height\" content=\"607\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"6 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"On-chip pump and valve in microfluidics\",\"datePublished\":\"2023-02-07T10:12:30+00:00\",\"dateModified\":\"2024-10-23T15:22:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/\"},\"wordCount\":1120,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system-e1677593149673.webp\",\"articleSection\":[\"Flow control\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/\",\"url\":\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/\",\"name\":\"On-chip pump and valve in microfluidics - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system-e1677593149673.webp\",\"datePublished\":\"2023-02-07T10:12:30+00:00\",\"dateModified\":\"2024-10-23T15:22:38+00:00\",\"description\":\"En esta revisión, conocerá diferentes métodos para integrar bombas y válvulas en un chip microfluídico a través de varios ejemplos.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system-e1677593149673.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system-e1677593149673.webp\",\"width\":470,\"height\":607,\"caption\":\"Design of the multi-valve system for controlling the inlet flows into microfluidic system\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"On-chip pump and valve in microfluidics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Nuestro blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/es\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"On-chip pump and valve in microfluidics - Darwin Microfluidics","description":"En esta revisión, conocerá diferentes métodos para integrar bombas y válvulas en un chip microfluídico a través de varios ejemplos.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/","og_locale":"en_US","og_type":"article","og_title":"On-chip pump and valve in microfluidics - Darwin Microfluidics","og_description":"In this review, you will learn different methods to integrate pumps and valves on a microfluidic chip through various examples.","og_url":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-07T10:12:30+00:00","article_modified_time":"2024-10-23T15:22:38+00:00","og_image":[{"width":470,"height":607,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system-e1677593149673.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"6 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"On-chip pump and valve in microfluidics","datePublished":"2023-02-07T10:12:30+00:00","dateModified":"2024-10-23T15:22:38+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/"},"wordCount":1120,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system-e1677593149673.webp","articleSection":["Flow control","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/","url":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/","name":"On-chip pump and valve in microfluidics - Darwin Microfluidics","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system-e1677593149673.webp","datePublished":"2023-02-07T10:12:30+00:00","dateModified":"2024-10-23T15:22:38+00:00","description":"En esta revisión, conocerá diferentes métodos para integrar bombas y válvulas en un chip microfluídico a través de varios ejemplos.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system-e1677593149673.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system-e1677593149673.webp","width":470,"height":607,"caption":"Design of the multi-valve system for controlling the inlet flows into microfluidic system"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/on-chip-pump-and-valve-in-microfluidics/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"On-chip pump and valve in microfluidics"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Nuestro blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Design_of_the_multi-valve_system_for_controlling_the_inlet_flows_into_microfluidic_system-e1677593149673.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/13907","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=13907"}],"version-history":[{"count":11,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/13907/revisions"}],"predecessor-version":[{"id":29722,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/13907/revisions/29722"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/13908"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=13907"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=13907"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=13907"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}