{"id":13914,"date":"2023-02-07T12:30:38","date_gmt":"2023-02-07T11:30:38","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=13914"},"modified":"2026-11-19T15:11:50","modified_gmt":"2026-11-19T14:11:50","slug":"bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/","title":{"rendered":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"13914\" class=\"elementor elementor-13914\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5c6a384b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5c6a384b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-185bb4a0\" data-id=\"185bb4a0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3cf1d3fe elementor-widget elementor-widget-text-editor\" data-id=\"3cf1d3fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p></p>\n<p class=\"wp-block-paragraph\">En esta nota de aplicación, comparamos la precisión y la estabilidad del caudal a bajos caudales de dos controladores de micropompas diseñados por Bartels Mikrotechnik GmbH: el <strong>mp-Lowdriver</strong> y el <strong>mp-Highdriver</strong>. Montados en la mp-Multiboard (placa de control principal) y conectados a una micropompa Bartels, estos controladores de bomba ofrecen diversas formas de ajustar la señal eléctrica aplicada a la bomba.</p>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\"></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ea19279 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ea19279\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c3328f8\" data-id=\"c3328f8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ebdeb61 elementor-widget elementor-widget-video\" data-id=\"ebdeb61\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings=\"{&quot;youtube_url&quot;:&quot;https:\\/\\/youtu.be\\/47NXqs9URzs&quot;,&quot;lazy_load&quot;:&quot;yes&quot;,&quot;video_type&quot;:&quot;youtube&quot;,&quot;controls&quot;:&quot;yes&quot;}\" data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"></div>\t\t</div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-772b504 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"772b504\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-21c5604\" data-id=\"21c5604\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-250da34 elementor-widget elementor-widget-text-editor\" data-id=\"250da34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\"><em><strong>Introducción al entorno Bartels: e</strong></em><em><strong>l mp-Lowdriver y el mp-Highdriver se pueden interconectar fácilmente en la mp-Multiboard.</strong></em></p>\n<p>La mp-Multiboard es una interfaz completa con un microcontrolador Arduino, que permite conectar y controlar micropompas mp6, válvulas activas, sensores de caudal Sensirion SLF3S y sensores de presión desde el mismo software.</p>\n<p>Las micropompas de Bartels se basan en tecnología piezoeléctrica y la señal eléctrica de entrada influye en el rendimiento de la bomba. Por lo tanto, se han desarrollado 3 drive para bombas: el mp-Lowdriver, el mp-Highdriver y el mp-Highdriver4. A diferencia del mp-Lowdriver y el mp-Highdriver, el mp-Highdriver4 permite controlar 4 bombas simultáneamente, mientras que los otros dos solo permiten controlar una bomba a la vez. Nos centraremos en el mp-Lowdriver y el mp-Highdriver, ya que el mp-Highdriver4 cuenta con las mismas especificaciones que el mp-Highdriver.</p>\n<h2 style=\"margin: 0px 0px 1em; line-height: 1.4; color: #000000; font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; letter-spacing: normal;\">Bartels Multiboard App: una interfaz de usuario unificada</h2>\n<p style=\"margin-right: 0px; margin-bottom: 1em; margin-left: 0px; line-height: 1.4; color: #000000; font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; font-size: 15px; letter-spacing: normal;\">Basándose en un entorno Arduino, Bartels ha desarrollado una aplicación para controlar fácilmente cualquier dispositivo conectado a la mp-Multiboard. Permite variar la frecuencia y la amplitud de cada una de las 4 bombas, abrir o cerrar las 2 válvulas y supervisar el caudal o la presión en tiempo real.</p>\n<p style=\"margin-right: 0px; margin-bottom: 1em; margin-left: 0px; line-height: 1.4; color: #000000; font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; font-size: 15px; letter-spacing: normal;\">Además, es posible controlar el tiempo de activación de cada una de las bombas y determinar cuál debe apagarse primero. ¡Esta aplicación facilita la creación de pequeños programas de varios pasos sin necesidad de escribir código!</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9191814 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9191814\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-b8f9162\" data-id=\"b8f9162\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-63470c1 elementor-widget elementor-widget-image\" data-id=\"63470c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"632\" height=\"748\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Bartels_multiboard_application_1-1.webp\" class=\"attachment-large size-large wp-image-13920\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Bartels_multiboard_application_1-1.webp 632w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Bartels_multiboard_application_1-1-253x300.webp 253w\" sizes=\"(max-width: 632px) 100vw, 632px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-05a5e23\" data-id=\"05a5e23\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a24d0f1 elementor-widget elementor-widget-image\" data-id=\"a24d0f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"628\" height=\"728\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Bartels_multiboard_application_2-1.webp\" class=\"attachment-large size-large wp-image-13921\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Bartels_multiboard_application_2-1.webp 628w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Bartels_multiboard_application_2-1-259x300.webp 259w\" sizes=\"(max-width: 628px) 100vw, 628px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-d954ddf\" data-id=\"d954ddf\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6917be0 elementor-widget elementor-widget-image\" data-id=\"6917be0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"634\" height=\"712\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Bartels_multiboard_application_3-1.webp\" class=\"attachment-large size-large wp-image-13922\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Bartels_multiboard_application_3-1.webp 634w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Bartels_multiboard_application_3-1-267x300.webp 267w\" sizes=\"(max-width: 634px) 100vw, 634px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b9b142d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b9b142d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1e17ae7\" data-id=\"1e17ae7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ca68ca0 elementor-widget elementor-widget-text-editor\" data-id=\"ca68ca0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>mp-Lowdriver frente a mp-Highdriver: ¿qué drive debe elegir?</h2>\n<p>Los drive para micropompas mp-Lowdriver y mp-Highdriver se diseñaron para satisfacer las necesidades de los investigadores que trabajan entre 5 µl/min y 10 ml/min. En microfluídica, los caudales inferiores a 100 µl/min son de uso común, y las micropompas de Bartels representan una alternativa rentable frente a las tecnologías actuales. La comparación de ambos drive le ayudará a seleccionar el adecuado para su aplicación, además de demostrar la precisión que estas micropompas y drive pueden ofrecer.</p>\n<p>Tabla 1: Comparativa entre los drive para micropompas mp-Lowdriver y mp-Highdriver (Bartels Mikrotechnik GmbH).</p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td>&nbsp;</td>\n<td><strong>mp-Lowdriver</strong></td>\n<td><strong>mp-Highdriver</strong></td>\n</tr>\n<tr>\n<td><strong>Dimensiones</strong></td>\n<td>10,16 x 25,4 x 2,64 mm</td>\n<td>10,16 x 25,40 x 2,82 mm</td>\n</tr>\n<tr>\n<td><strong>Amplitud</strong></td>\n<td>0 a 150 Vpp</td>\n<td>10 a 150 Vpp</td>\n</tr>\n<tr>\n<td><strong>Frecuencia</strong></td>\n<td>8 a 2000 Hz</td>\n<td>50 a 800 Hz</td>\n</tr>\n<tr>\n<td><strong>Forma de señal</strong></td>\n<td>senoidal, personalizada</td>\n<td>senoidal, rectangular, personalizada</td>\n</tr>\n</tbody>\n</table>\n<p><em><strong>Tabla 1: Comparativa entre los drive para micropompas mp-Lowdriver y mp-Highdriver (Bartels Mikrotechnik GmbH).</strong></em></p>\n<p>Las siguientes mediciones de caudal se realizaron con un sensor de caudal térmico Sensirion SLF3S-0600F (precisión de +/- 5 % en un rango de +/- 2000 µl/min, precisión mín. de 0,5 µl/min), también utilizado en el sistema mpSmart-Lowdosing de Bartels.</p>\n<h3>Mediciones de caudal del mp-Lowdriver</h3>\n<p>Se realizaron dos mediciones a 5 y 10 µl/min con el mp-Lowdriver durante unos segundos. Estas mediciones nos permitieron evaluar las capacidades del mp-Lowdriver a caudales muy bajos. </p>\n<table>\n<tbody>\n<tr>\n<td><em>mp-Lowdriver</em></td>\n<td><strong>5 µl/min</strong></td>\n<td><strong>10 µl/min</strong></td>\n</tr>\n<tr>\n<td><strong>Valor medido (µl/min)</strong></td>\n<td>5.22</td>\n<td>10.86</td>\n</tr>\n<tr>\n<td><strong>Error estándar</strong></td>\n<td>0.57</td>\n<td>0.46</td>\n</tr>\n<tr>\n<td><strong>Error estándar (%)</strong></td>\n<td>10.89</td>\n<td>4.23</td>\n</tr>\n</tbody>\n</table>\n<p><em><strong>Tabla 2: Comparación entre los valores objetivo y medidos a 5 y 10 µl/min con una mp6-liq, mp-Multiboard y mp-Lowdriver (Bartels Mikrotechnik). Medido con un sensor de caudal térmico SLF3S-0600F (Sensirion).</strong></em></p>\n<p>&nbsp;</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-fa36fdf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"fa36fdf\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-7856e43\" data-id=\"7856e43\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f6744f2 elementor-widget elementor-widget-image\" data-id=\"f6744f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"456\" height=\"274\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/5_ulmin_Lowdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13929\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/5_ulmin_Lowdriver_mesure.webp 456w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/5_ulmin_Lowdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 456px) 100vw, 456px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-7baaed1\" data-id=\"7baaed1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4db9992 elementor-widget elementor-widget-image\" data-id=\"4db9992\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"464\" height=\"279\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/10_ulmin_Lowdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13930\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/10_ulmin_Lowdriver_mesure.webp 464w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/10_ulmin_Lowdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 464px) 100vw, 464px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-748d87f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"748d87f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c028350\" data-id=\"c028350\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-bc8e33c elementor-widget elementor-widget-text-editor\" data-id=\"bc8e33c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong><em>Figura 2: Caudales reales con una micropompa mp6-liq y mp-Lowdriver (Bartels Mikrotechnik) para caudales objetivo de 5 y 10 µl/min. Medido con un sensor de caudal SLF3S-0600F (Sensirion).</em></strong></p>\n<p>Las micropompas de Bartels están indicadas para caudales superiores a 5 µl/min. Aunque el mp-Lowdriver puede alcanzar valores inferiores, el sensor de caudal SLF3S-0600F tiene una precisión mínima de +/- 5% o 0,5 µl/min, lo cual solo es relevante para caudales superiores a 5 µl/min. Las mediciones realizadas a 5 y 10 µl/min muestran que la precisión del sensor de caudal constituye la limitación para medir con exactitud los caudales de salida, pero la precisión del caudal es lo suficientemente baja como para abordar la mayoría de las aplicaciones en microfluídica.</p>\n<p>Con el fin de evaluar mejor las capacidades del mp-Lowdriver, hemos ampliado el rango de medición más allá de 10 µl/min hasta 50 µl/min. Los resultados se muestran a continuación.</p>\n<table>\n<tbody>\n<tr>\n<td>\n<p><em>mp-Lowdriver</em></p>\n</td>\n<td>\n<p><strong>20 µl/min</strong></p>\n</td>\n<td>\n<p><strong>30 µl/min</strong></p>\n</td>\n<td>\n<p><strong>40 µl/min</strong></p>\n</td>\n<td>\n<p><strong>50 µl/min</strong></p>\n</td>\n</tr>\n<tr>\n<td>\n<p><strong>Valor medido (µl/min)</strong></p>\n</td>\n<td>\n<p>21.04</p>\n</td>\n<td>\n<p>30.57</p>\n</td>\n<td>\n<p>39.99</p>\n</td>\n<td>\n<p>51.21</p>\n</td>\n</tr>\n<tr>\n<td>\n<p><strong>Error estándar</strong></p>\n</td>\n<td>\n<p>0.53</p>\n</td>\n<td>\n<p>1.30</p>\n</td>\n<td>\n<p>1.47</p>\n</td>\n<td>\n<p>0.89</p>\n</td>\n</tr>\n<tr>\n<td>\n<p><strong>Error estándar (%)</strong></p>\n</td>\n<td>\n<p>2.51</p>\n</td>\n<td>\n<p>4.24</p>\n</td>\n<td>\n<p>3.68</p>\n</td>\n<td>\n<p>1.74</p>\n</td>\n</tr>\n</tbody>\n</table>\n<p><em><strong> Tabla 3: Comparación entre los valores objetivo y medidos a 20, 30, 40 y 50 µl/min con una mp6-liq, mp-Multiboard y mp-Lowdriver (Bartels Mikrotechnik). Medido con un sensor de caudal térmico SLF3S-0600F (Sensirion).</strong></em></p>\n<p>&nbsp;</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0dfb1ca elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0dfb1ca\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-76ade63\" data-id=\"76ade63\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d752c0b elementor-widget elementor-widget-image\" data-id=\"d752c0b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"385\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/20_ulmin_Lowdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13931\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/20_ulmin_Lowdriver_mesure.webp 752w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/20_ulmin_Lowdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-8c61b9f\" data-id=\"8c61b9f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-37bf30d elementor-widget elementor-widget-image\" data-id=\"37bf30d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"385\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/30_ulmin_Lowdriver_measure.webp\" class=\"attachment-large size-large wp-image-13932\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/30_ulmin_Lowdriver_measure.webp 752w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/30_ulmin_Lowdriver_measure-300x180.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-522bdf6 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"522bdf6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-87c9887\" data-id=\"87c9887\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6f53318 elementor-widget elementor-widget-image\" data-id=\"6f53318\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"385\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/40_ulmin_Lowdriver_measure.webp\" class=\"attachment-large size-large wp-image-13933\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/40_ulmin_Lowdriver_measure.webp 752w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/40_ulmin_Lowdriver_measure-300x180.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-3ffa527\" data-id=\"3ffa527\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ec94af1 elementor-widget elementor-widget-image\" data-id=\"ec94af1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"385\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/50_ulmin_Lowdriver_measure.webp\" class=\"attachment-large size-large wp-image-13934\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/50_ulmin_Lowdriver_measure.webp 752w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/50_ulmin_Lowdriver_measure-300x180.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-109de36 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"109de36\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4e33c9c\" data-id=\"4e33c9c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6ed9bb3 elementor-widget elementor-widget-text-editor\" data-id=\"6ed9bb3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em><strong>Figura 3: Caudales reales con una micropompa mp6-liq y mp-Lowdriver (Bartels Mikrotechnik) para caudales objetivo de 20, 30, 40 y 50 µl/min. Medido con un sensor de caudal SLF3S-0600F (Sensirion).</strong></em></p>\n<p>Estos resultados demuestran que el mp-Lowdriver es muy adecuado para caudales de entre 20 y 50 µl/min. De hecho, el error, en todos los casos, es inferior al 5% (límite del sensor de caudal).</p>\n<p>Por lo tanto, podemos concluir que el mp-Lowdriver se puede utilizar para aplicaciones que requieran caudales superiores a 5 µl/min. Deben realizarse pruebas adicionales para abordar caudales inferiores a 5 µl/min utilizando sensores de caudal más precisos.</p>\n<h3>Mediciones de caudal del mp-Highdriver</h3>\n<p>Realizamos 4 mediciones (50, 200, 500 y 850 µl/min) durante unos segundos para evaluar las capacidades del mp-Highdriver para caudales más elevados. Los resultados se muestran a continuación.</p>\n<table>\n<tbody>\n<tr>\n<td>\n<p><em>mp-Highdriver</em></p>\n</td>\n<td>\n<p><strong>50 µl/min</strong></p>\n</td>\n<td>\n<p><strong>200 µl/min</strong></p>\n</td>\n<td>\n<p><strong>500 µl/min</strong></p>\n</td>\n<td>\n<p><strong>850 µl/min</strong></p>\n</td>\n</tr>\n<tr>\n<td>\n<p><strong>Valor medido (µl/min)</strong></p>\n</td>\n<td>\n<p>51.62</p>\n</td>\n<td>\n<p>202.86</p>\n</td>\n<td>\n<p>498.09</p>\n</td>\n<td>\n<p>849.35</p>\n</td>\n</tr>\n<tr>\n<td>\n<p><strong>Error estándar</strong></p>\n</td>\n<td>\n<p>0.96</p>\n</td>\n<td>\n<p>1.05</p>\n</td>\n<td>\n<p>1.86</p>\n</td>\n<td>\n<p>2.79</p>\n</td>\n</tr>\n<tr>\n<td>\n<p><strong>Error estándar (%)</strong></p>\n</td>\n<td>\n<p>1.86</p>\n</td>\n<td>\n<p>0.51</p>\n</td>\n<td>\n<p>0.37</p>\n</td>\n<td>\n<p>0.33</p>\n</td>\n</tr>\n</tbody>\n</table>\n<p><em><strong> Tabla 4: Comparación entre los valores objetivo y medidos a 50, 200, 500 y 850 µl/min con una mp6-liq, mp-Multiboard y mp-Lowdriver (Bartels Mikrotechnik). Medido con un sensor de caudal térmico SLF3S-0600F (Sensirion).</strong></em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-018e838 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"018e838\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-50c35f7\" data-id=\"50c35f7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8e1ae73 elementor-widget elementor-widget-image\" data-id=\"8e1ae73\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"458\" height=\"275\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/50_ulmin_highdriver_mesure_25bceb57-00f0-424d-ad95-d958746de7b5.webp\" class=\"attachment-large size-large wp-image-13935\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/50_ulmin_highdriver_mesure_25bceb57-00f0-424d-ad95-d958746de7b5.webp 458w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/50_ulmin_highdriver_mesure_25bceb57-00f0-424d-ad95-d958746de7b5-300x180.webp 300w\" sizes=\"(max-width: 458px) 100vw, 458px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-9db952d\" data-id=\"9db952d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-23ed340 elementor-widget elementor-widget-image\" data-id=\"23ed340\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"459\" height=\"276\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/200_ulmin_highdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13936\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/200_ulmin_highdriver_mesure.webp 459w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/200_ulmin_highdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 459px) 100vw, 459px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f2951a3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f2951a3\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-79c8410\" data-id=\"79c8410\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3bb05dd elementor-widget elementor-widget-image\" data-id=\"3bb05dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"464\" height=\"279\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/500_ulmin_highdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13937\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/500_ulmin_highdriver_mesure.webp 464w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/500_ulmin_highdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 464px) 100vw, 464px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-06d04cf\" data-id=\"06d04cf\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7a1d3d4 elementor-widget elementor-widget-image\" data-id=\"7a1d3d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"461\" height=\"277\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/850_ulmin_highdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13938\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/850_ulmin_highdriver_mesure.webp 461w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/850_ulmin_highdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 461px) 100vw, 461px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-40442b0 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"40442b0\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b1f4bbc\" data-id=\"b1f4bbc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4168d1d elementor-widget elementor-widget-text-editor\" data-id=\"4168d1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em><b>Figura 2: Caudales reales con una micropompa mp6-liq y mp-Highdriver (Bartels Mikrotechnik) para caudales objetivo de 50, 200, 500 y 850 µl/min. Medido con un sensor de caudal SLF3S-0600F (Sensirion).<br></b></em></p>\n<p>Los resultados obtenidos con el mp-Highdriver son muy satisfactorios para el rango probado. De hecho, el error, sea cual sea el caudal probado, es muy inferior al 2% (por debajo del límite de precisión del sensor de caudal), lo que pone de manifiesto una excelente estabilidad del dispositivo.</p>\n<p>Al analizar el valor objetivo de 50 µl/min medido tanto con el mp-Lowdriver como con el mp-Highdriver, los resultados muestran valores medidos muy similares. Para este caudal, el usuario puede elegir entre el mp-Lowdriver y el mp-Highdriver.</p>\n<h3>Conclusión</h3>\n<p>Bartels Mikrotechnik ha creado un entorno potente y fácil de usar para controlar y monitorizar fluidos en una amplia gama de aplicaciones, desde la milifluídica hasta la microfluídica. Combinados con la mp-Multiboard y una micropompa, tanto el mp-Lowdriver como el mp-Highdriver ofrecen formas eficaces de impulsar fluidos en un sistema microfluídico, con una excelente relación precio-precisión.</p>\n<p>Darwin Microfluidics es un distribuidor mundial de productos Bartels. ¡Encuentre todos los componentes para crear su configuración microfluídica <a href=\"https://darwin-microfluidics.com/es/collections/bartels\"><strong><span style=\"color: #0000ff;\">aquí</span></strong></a>!</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>En esta nota de aplicación, comparamos la precisión y la estabilidad del caudal a caudales bajos de dos controladores de microbombas diseñados por Bartels Mikrotechnik GmbH: el mp-Lowdriver y el mp-Highdriver. Montados en la mp-Multiboard (placa de control principal) y conectados a una microbomba Bartels, estas bombas…</p>\n","protected":false},"author":3,"featured_media":14796,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[29,24],"tags":[],"class_list":["post-13914","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","category-flow-control"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Comparativa de Bartels mp-Lowdriver y mp-Highdriver para bajos caudales - Darwin Microfluidics</title>\n<meta name=\"description\" content=\"En esta revisión, comparamos la precisión y la estabilidad del caudal a bajos caudales de dos controladores de micropompas diseñados por Bartels Mikrotechnik GmbH.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Comparativa de Bartels mp-Lowdriver y mp-Highdriver para bajos caudales - Darwin Microfluidics\">\n<meta property=\"og:description\" content=\"En esta revisión, comparamos la precisión y la estabilidad del caudal a bajos caudales de dos controladores de micropompas diseñados por Bartels Mikrotechnik GmbH.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-07T11:30:38+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:11:50+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/mp-Highdriver4-Pump-Driver_2048x2048-1.webp\">\n\t<meta property=\"og:image:width\" content=\"1000\">\n\t<meta property=\"og:image:height\" content=\"1000\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"8 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates\",\"datePublished\":\"2023-02-07T11:30:38+00:00\",\"dateModified\":\"2026-11-19T14:11:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/\"},\"wordCount\":1084,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/mp-Highdriver4-Pump-Driver_2048x2048-1.webp\",\"articleSection\":[\"Application notes\",\"Flow control\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/\",\"url\":\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/\",\"name\":\"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/mp-Highdriver4-Pump-Driver_2048x2048-1.webp\",\"datePublished\":\"2023-02-07T11:30:38+00:00\",\"dateModified\":\"2026-11-19T14:11:50+00:00\",\"description\":\"En esta revisión, comparamos la precisión y la estabilidad del caudal a bajos caudales de dos controladores de micropompas diseñados por Bartels Mikrotechnik GmbH.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/mp-Highdriver4-Pump-Driver_2048x2048-1.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/mp-Highdriver4-Pump-Driver_2048x2048-1.webp\",\"width\":1000,\"height\":1000,\"caption\":\"Photograph of a Bartels Highdriver4. White Backkground\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Nuestro blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/es\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates - Darwin Microfluidics","description":"En esta revisión, comparamos la precisión y la estabilidad del caudal a bajos caudales de dos controladores de micropompas diseñados por Bartels Mikrotechnik GmbH.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/","og_locale":"en_US","og_type":"article","og_title":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates - Darwin Microfluidics","og_description":"In this review, we compare the flow accuracy and stability at low flow rates of two micropump drivers designed by Bartels Mikrotechnik GmbH.","og_url":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-07T11:30:38+00:00","article_modified_time":"2026-11-19T14:11:50+00:00","og_image":[{"width":1000,"height":1000,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"8 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates","datePublished":"2023-02-07T11:30:38+00:00","dateModified":"2026-11-19T14:11:50+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/"},"wordCount":1084,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","articleSection":["Application notes","Flow control"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/","url":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/","name":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates - Darwin Microfluidics","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","datePublished":"2023-02-07T11:30:38+00:00","dateModified":"2026-11-19T14:11:50+00:00","description":"En esta revisión, comparamos la precisión y la estabilidad del caudal a bajos caudales de dos controladores de micropompas diseñados por Bartels Mikrotechnik GmbH.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","width":1000,"height":1000,"caption":"Photograph of a Bartels Highdriver4. White Backkground"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Nuestro blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/13914","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=13914"}],"version-history":[{"count":14,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/13914/revisions"}],"predecessor-version":[{"id":15224,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/13914/revisions/15224"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14796"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=13914"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=13914"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=13914"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}