{"id":14373,"date":"2023-02-22T14:44:34","date_gmt":"2023-02-22T13:44:34","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14373"},"modified":"2024-02-27T12:10:11","modified_gmt":"2024-02-27T11:10:11","slug":"recirculation-for-cell-culture-in-microfluidics","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/","title":{"rendered":"Recirculation for cell culture in microfluidics"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14373\" class=\"elementor elementor-14373\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-734e162 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"734e162\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-d7908cb\" data-id=\"d7908cb\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0afd1be elementor-widget elementor-widget-text-editor\" data-id=\"0afd1be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Los chips microfluídicos pueden proporcionar un entorno biomimético para el cultivo celular y de tejidos, preservando aspectos clave del sistema biológico al tiempo que integran análisis posteriores. Es posible ir más allá integrando un suministro continuo de nutrientes mediante la recirculación del medio. En este tutorial, presentaremos las diferentes técnicas de recirculación y las formas existentes para llevarlas a cabo.</p><p>En resumen, la recirculación se logra habitualmente utilizando una bomba peristáltica para devolver el efluente de salida al depósito de entrada, permitiendo que la suspensión pase de nuevo a través del dispositivo.</p><h2>Ventajas de la recirculación en el cultivo celular:</h2><ul><li>La integración de la recirculación en un dispositivo microfluídico nos permitirá acercarnos un poco más a la realidad, así como comprender la <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">absorción</a>, distribución, metabolismo y eliminación de fármacos. De hecho, cada órgano, tejido o célula del cuerpo humano es irrigado continuamente a través de fluidos corporales, ya sea en circuito abierto (saliva, líquido gástrico, orina...) o en circuito cerrado (sangre, linfa, líquido pleural...).</li><li>Dependiendo de la instalación, puede permitir la eliminación de los residuos, lo que puede mejorar considerablemente el rendimiento del experimento y, una vez más, imitar la realidad.</li><li>La técnica de recirculación también permite ahorrar medio de cultivo, que puede resultar muy costoso para las células primarias, y enriquece el medio con factores de secreción celular. No obstante, cabe destacar que la circulación cerrada requiere que el medio se suministre con CO2 dentro del chip. Esto puede hacerse utilizando un material permeable al gas o un medio independiente de CO2 durante periodos cortos (aproximadamente 2 horas).</li></ul><h2>Recirculación con una bomba peristáltica en cultivo celular</h2><p>Las bombas peristálticas se utilizan ampliamente en el cultivo celular por su facilidad de uso y conexión. Las bombas peristálticas se pueden utilizar en diversas situaciones, pero en la mayoría de los casos se emplean para recircular fluido a través de un chip. El número de muestras que se pueden infundir en paralelo suele oscilar entre 1 y 24, según el número de canales del cabezal de la bomba.</p><p>Por definición, las bombas peristálticas proporcionan un flujo pulsátil. La frecuencia y la amplitud de las oscilaciones varían de una bomba a otra según el número de rodillos, su frecuencia de rotación y el diámetro del tube utilizado. La mayoría de las bombas peristálticas se controlan mediante un software que permite automatizar protocolos como la inyección periódica o las variaciones simples de caudal.</p><p>En la mayoría de los casos, todos los tubes se enrollan alrededor de un rotor y, por lo tanto, proporcionan el mismo caudal en cada chip, lo que puede ser limitante para algunos estudios. Sin embargo, están saliendo al mercado nuevos modelos que permiten infundir varias muestras al mismo tiempo de forma independiente. Hoy en día, las formulaciones de tube específicas para bombas peristálticas aumentan considerablemente su vida útil, garantizando un rendimiento óptimo y reproducible.</p><p>La recirculación de medios también es posible con una bomba peristáltica miniaturizada en el chip basada en microcanales controlados neumáticamente, tal como informaron Balagaddé et al. <strong>[Balagaddé et al., Science 2005]</strong>.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2fc8ab4 elementor-widget elementor-widget-image\" data-id=\"2fc8ab4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"220\" height=\"300\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-220x300.webp\" class=\"attachment-medium size-medium wp-image-14376\" alt=\"Imagen de un sistema de recirculación con la bomba peristáltica Reglo ICC de Ismatec y la plataforma organe sur puce de Mesobiotech. La recirculación se establece a través de tube de silicona curada con platino de 3 topes y adaptadores cannelé (barbed) a Luer macho de Darwin Microfluidics\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-220x300.webp 220w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-752x1024.webp 752w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-768x1046.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-1128x1536.webp 1128w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-1504x2048.webp 1504w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp 1880w\" sizes=\"(max-width: 220px) 100vw, 220px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figura 1: Imagen de un sistema de recirculación con la bomba peristáltica Reglo ICC de Ismatec y la plataforma de organe sur puce de Mesobiotech. La recirculación se establece a través de un tube de silicona curada con platino de 3 paradas y adaptadores cannelé (barbed) a Luer macho de Darwin Microfluidics</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3a06c8 elementor-widget elementor-widget-global elementor-global-18292 elementor-widget-pix-promo-box\" data-id=\"e3a06c8\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Peristatic-pumps_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"¿ESTÁ PREPARADO PARA UNA MANIPULACIÓN DE FLUIDOS FIABLE?\"><a href=\"https://darwin-microfluidics.com/es/collections/bombas-peristalticas\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">¡Descubra nuestra selección!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">¿ESTÁ PREPARADO PARA UNA MANIPULACIÓN DE FLUIDOS FIABLE?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explore nuestras bombas peristálticas para una impulsión de fluidos constante y precisa en su laboratorio</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90b245b elementor-widget elementor-widget-text-editor\" data-id=\"90b245b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Otras configuraciones</h2><p>Más allá del bombeo peristáltico, es posible crear un bucle de inyección utilizando otras tecnologías de bombeo. Este método consiste en una red de entradas/salidas que se pueden conectar entre sí en una configuración que permite un montaje de recirculación con un caudal que siempre atraviesa el dispositivo microfluídico en la misma dirección.</p><p>Para realizar este bucle de inyección, necesitará:</p><ul><li><span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https://darwin-microfluidics.com/es/productos/ob1-mk3-flow-controller?variant=7241063628845\">Controlador de presión</a></strong></span> (Sistema de control de flujo microfluídico de 4 canales)</li><li>Sensor de caudal (<span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https://darwin-microfluidics.com/es/productos/microfluidic-thermal-flow-sensor?variant=36067511105\">Sensor de flujo térmico microfluídico MFS</a></strong></span>)</li><li>Válvula de inyección (<span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https://darwin-microfluidics.com/es/productos/mux-recirculation?variant=37496408506532\">MUX Recirculación</a></strong></span>)</li><li>Dispositivo microfluídico (<a href=\"https://darwin-microfluidics.com/es/collections/organ-on-a-chip-microfluidico/productos/organ-on-a-chip-top-and-bottom-layers-pack-of-4\"><span style=\"text-decoration: underline; color: #0000ff;\"><strong>Organe sur puce microfluídico</strong></span></a>)</li><li>Reservorios de muestras (<span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https://darwin-microfluidics.com/es/productos/50-ml-falcon-tube-microfluidic-reservoir-m-2-4-port\">Reservorio microfluídico</a></strong></span>)</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e541bc7 elementor-widget elementor-widget-image\" data-id=\"e541bc7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https://www.elveflow.com/microfluidics-application-packs/biology-packs/one-way-recirculation/\" target=\"_blank\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"264\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Recirculation-setup-Elveflow-1-300x264.webp\" class=\"attachment-medium size-medium wp-image-14377\" alt=\"Esquema de la configuración de recirculación - Elveflow OB1\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Recirculation-setup-Elveflow-1-300x264.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Recirculation-setup-Elveflow-1-1024x900.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Recirculation-setup-Elveflow-1-768x675.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Recirculation-setup-Elveflow-1.webp 1050w\" sizes=\"(max-width: 300px) 100vw, 300px\">\t\t\t\t\t\t\t\t</a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figura 2: Ilustración de un montaje de recirculación del pack de recirculación de ELVEFLOW próximamente disponible. El uso de la válvula de inyección permite la recirculación multiposición. Extraído del sitio web de ELVEFLOW. </figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1362c85 elementor-widget elementor-widget-text-editor\" data-id=\"1362c85\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Mediante el uso de un controlador de presión, el flujo será mucho más regular y sin impulsos, a diferencia del uso de una bomba peristáltica. Esta configuración permitirá la automatización completa de sus experimentos, ya duren 2 horas o 1 semana, con volúmenes de medios limitados o aplicaciones más avanzadas como la modelización de flujos biológicos complejos.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Microfluidic chips can provide a biomimetic environment for cell and tissue culture, preserving key aspects of the biological system while integrating downstream analysis. It is even possible to go further by integrating a continuous supply of nutrients via recirculation of…</p>\n","protected":false},"author":3,"featured_media":14376,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[27,21],"tags":[],"class_list":["post-14373","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Recirculación para cultivo celular en microfluídica - Darwin Microfluidics</title>\n<meta name=\"description\" content=\"La recirculación se logra habitualmente devolviendo el efluente de salida al depósito de entrada para que la suspensión pueda atravesar el dispositivo de nuevo.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Recirculación para cultivo celular en microfluídica - Darwin Microfluidics\">\n<meta property=\"og:description\" content=\"La recirculación se logra habitualmente devolviendo el efluente de salida al depósito de entrada para que la suspensión pueda atravesar el dispositivo de nuevo.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-22T13:44:34+00:00\">\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:10:11+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp\">\n\t<meta property=\"og:image:width\" content=\"1880\">\n\t<meta property=\"og:image:height\" content=\"2560\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"4 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Recirculation for cell culture in microfluidics\",\"datePublished\":\"2023-02-22T13:44:34+00:00\",\"dateModified\":\"2024-02-27T11:10:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\"},\"wordCount\":697,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\",\"url\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\",\"name\":\"Recirculation for cell culture in microfluidics - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp\",\"datePublished\":\"2023-02-22T13:44:34+00:00\",\"dateModified\":\"2024-02-27T11:10:11+00:00\",\"description\":\"La recirculación se logra habitualmente devolviendo el efluente de salida al depósito de entrada para que la suspensión pueda atravesar el dispositivo de nuevo.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp\",\"width\":1880,\"height\":2560,\"caption\":\"Picture of a recirculation system with the Reglo ICC peristaltic pump from Ismatec and the organ-on-a-chip platform from Mesobiotech. The recirculation is established through 3-stop platinum-cured silicone tubing and barbed to male Luer slip adaptaters from Darwin Microfluidics\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Recirculation for cell culture in microfluidics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Nuestro blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/es\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Recirculation for cell culture in microfluidics - Darwin Microfluidics","description":"La recirculación se logra habitualmente devolviendo el efluente de salida al depósito de entrada para que la suspensión pueda atravesar el dispositivo de nuevo.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/","og_locale":"en_US","og_type":"article","og_title":"Recirculation for cell culture in microfluidics - Darwin Microfluidics","og_description":"Recirculation is usually achieved by returning the outlet eluent to the inlet tank so that the suspension can pass through the device again.","og_url":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T13:44:34+00:00","article_modified_time":"2024-02-27T11:10:11+00:00","og_image":[{"width":1880,"height":2560,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"4 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Recirculation for cell culture in microfluidics","datePublished":"2023-02-22T13:44:34+00:00","dateModified":"2024-02-27T11:10:11+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/"},"wordCount":697,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","articleSection":["Cell culture &amp; organ-on-chip","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/","url":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/","name":"Recirculation for cell culture in microfluidics - Darwin Microfluidics","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","datePublished":"2023-02-22T13:44:34+00:00","dateModified":"2024-02-27T11:10:11+00:00","description":"La recirculación se logra habitualmente devolviendo el efluente de salida al depósito de entrada para que la suspensión pueda atravesar el dispositivo de nuevo.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","width":1880,"height":2560,"caption":"Picture of a recirculation system with the Reglo ICC peristaltic pump from Ismatec and the organ-on-a-chip platform from Mesobiotech. The recirculation is established through 3-stop platinum-cured silicone tubing and barbed to male Luer slip adaptaters from Darwin Microfluidics"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Recirculation for cell culture in microfluidics"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Nuestro blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14373","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14373"}],"version-history":[{"count":18,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14373/revisions"}],"predecessor-version":[{"id":18443,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14373/revisions/18443"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14376"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14373"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14373"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14373"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}