{"id":14403,"date":"2023-02-22T15:27:38","date_gmt":"2023-02-22T14:27:38","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14403"},"modified":"2026-11-19T15:12:54","modified_gmt":"2026-11-19T14:12:54","slug":"comparison-of-new-era-infusionone-and-syringeone","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/","title":{"rendered":"Comparison of New Era InfusionONE and SyringeONE"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14403\" class=\"elementor elementor-14403\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ca43699 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ca43699\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-91f86a5\" data-id=\"91f86a5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0d1f40c elementor-widget elementor-widget-text-editor\" data-id=\"0d1f40c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La bomba de jeringa es un dispositivo ajustable que genera un caudal mediante el desplazamiento volumétrico de líquido en el cuerpo de la jeringa. El caudal se calcula según la sección y la velocidad del movimiento del pistón <span class=\"katex-eq\" data-katex-display=\"false\">Q=S_{piston}\\times \\nu _{piston}</span>.</p><p>La presión aplicada al conjunto no está controlada y depende de su resistencia fluídica. Puede alcanzar valores elevados (&gt;100 bar) para jeringas de pequeño volumen, caudales elevados o conjuntos de alta resistencia fluídica (líquidos viscosos y canales de pequeñas dimensiones).</p><p>Con una jeringa de tipo « bomba de jeringa », el tiempo de estabilización puede ser prolongado. Esto puede deberse a la elasticidad de las paredes de la jeringa utilizada y, en menor medida, al tipo de tubo empleado.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-2031d12 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2031d12\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-1f14fac\" data-id=\"1f14fac\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7cd05c3 elementor-widget elementor-widget-image\" data-id=\"7cd05c3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"166\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_InfusionONE_Syringe_pump_NE-300-1-300x166.webp\" class=\"attachment-medium size-medium wp-image-14406\" alt=\"Fotografía del InfusionONE rojo bomba de jeringa\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_InfusionONE_Syringe_pump_NE-300-1-300x166.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_InfusionONE_Syringe_pump_NE-300-1.webp 568w\" sizes=\"(max-width: 300px) 100vw, 300px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-e90ee7c\" data-id=\"e90ee7c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c3a308e elementor-widget elementor-widget-image\" data-id=\"c3a308e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"300\" height=\"197\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_SyringeONE_Syringe_pump_NE-1000_from_New_Era-1-300x197.webp\" class=\"attachment-medium size-medium wp-image-14407\" alt=\"Fotografía de la SyringeONE roja bomba de jeringa\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_SyringeONE_Syringe_pump_NE-1000_from_New_Era-1-300x197.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/The_SyringeONE_Syringe_pump_NE-1000_from_New_Era-1.webp 720w\" sizes=\"(max-width: 300px) 100vw, 300px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<div class=\"elementor-element elementor-element-46bfd97 elementor-widget elementor-widget-text-editor\" data-id=\"46bfd97\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\"><em>Figura 1: (A) La bomba de jeringa InfusionONE NE-300 y (B) La bomba de jeringa SyringeONE NE-1000 de New Era</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-19fe9cd elementor-widget elementor-widget-global elementor-global-18289 elementor-widget-pix-promo-box\" data-id=\"19fe9cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Syringe-pumps_1920x600_DARWIIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"¿BUSCA OPCIONES DE BOMBEO VERSÁTILES?\"><a href=\"https://darwin-microfluidics.com/es/collections/bomba-de-jeringa\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">¡Descubra nuestra selección!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">¿BUSCA OPCIONES DE BOMBEO VERSÁTILES?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>¡Un control inigualable del suministro de fluidos gracias a nuestro sistema de control de flujo de alto rendimiento « bombas de jeringa »!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c35ea6 elementor-widget elementor-widget-text-editor\" data-id=\"2c35ea6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Características de las bombas de jeringa NE-300 y NE-1000 de New Era</h2><h3>La bomba de jeringa InfusionONE NE-300 de New Era Pump Systems</h3><p>La bomba de jeringa de 1 vía InfusionONE es fácil de usar gracias a su funcionamiento en 3 pasos. La unidad, la velocidad y la dirección del flujo son programables por el usuario.</p><ul><li>Volumen de la jeringa: hasta 60 mL</li><li>Rango de diámetro interior de la jeringa: de 0.100 a 50 mm</li><li>Rango de caudal: de 0.73 µl/h a 1500 ml/h</li><li>Precisión del caudal: +/- 1 %</li></ul><h3>La bomba de jeringa SyringeONE NE-1000 de New Era Pump Systems</h3><p>La bomba SyringeONE es totalmente programable, ya sea de forma autónoma o a través de un ordenador. Según las necesidades del usuario, la SyringeONE está disponible en diferentes versiones en función del número de canales y de la fuerza lineal. En este artículo nos centraremos en la versión estándar (NE-2000).</p><ul><li>Volumen de la jeringa: hasta 140 mL</li><li>Rango de caudal: de 8 pL/h a 1961 mL/min</li><li>Precisión del caudal: +/- 1 %</li></ul><h2>Pruebas de medición de la precisión del caudal</h2><p>Para nuestras pruebas, decidimos comparar dos bombas de jeringa de New Era Pump Systems: la NE-300 y la NE-1000. La serie de bombas de jeringa de New Era Pump Systems constituye una solución rentable para dispensar un control preciso de fluidos. Nuestro objetivo aquí es comparar la precisión con la que ambas bombas de jeringa suministran caudal a partir de un valor de caudal establecido (de 50 a 500 µl/min). Se utiliza una jeringa de 2,5 mL en cada bomba de jeringa, y la precisión se mide utilizando el sensor de caudal ELVEFLOW MFS4.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-342af2b elementor-widget elementor-widget-image\" data-id=\"342af2b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"386\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Graph_of_the_deviation_from_the_value_of_50_l-min-1.webp\" class=\"attachment-medium_large size-medium_large wp-image-14411\" alt=\"Gráfico de estabilidad del caudal de la syringeONE y la infusionONE a 50 ul/min\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Graph_of_the_deviation_from_the_value_of_50_l-min-1.webp 752w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Graph_of_the_deviation_from_the_value_of_50_l-min-1-300x181.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-36bc2c4 elementor-widget elementor-widget-text-editor\" data-id=\"36bc2c4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A caudales bajos, ambas bombas de jeringa parecen tener la misma sensibilidad, especialmente tras un periodo de estabilización de unos 4 segundos. En general, a 50 µl/min, las dos bombas de jeringa proporcionan caudales un 5 % superiores al valor establecido.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-42ab144 elementor-widget elementor-widget-image\" data-id=\"42ab144\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"388\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Graph_of_the_deviation_from_the_value_of_100_l-min-1.webp\" class=\"attachment-large size-large wp-image-14415\" alt=\"Gráfico de estabilidad del caudal de la syringeONE y la infusionONE a 100 ul/min\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Graph_of_the_deviation_from_the_value_of_100_l-min-1.webp 746w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Graph_of_the_deviation_from_the_value_of_100_l-min-1-300x182.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-322e731 elementor-widget elementor-widget-text-editor\" data-id=\"322e731\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Para un valor intermedio de 100 µl/min, la NE-1000 parece más adecuada, ya que presenta un perfil de caudal con una desviación generalmente inferior al 2 % respecto al valor de 100 µl/min.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ac42c9e elementor-widget elementor-widget-image\" data-id=\"ac42c9e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"386\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Graph_of_the_deviation_from_the_value_of_500_l-min-1.webp\" class=\"attachment-large size-large wp-image-14419\" alt=\"Gráfico de estabilidad del caudal de la syringeONE y la infusionONE a 500 ul/min\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Graph_of_the_deviation_from_the_value_of_500_l-min-1.webp 752w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Graph_of_the_deviation_from_the_value_of_500_l-min-1-300x181.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8fec7ec elementor-widget elementor-widget-text-editor\" data-id=\"8fec7ec\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Por último, para valores elevados, la bomba de jeringa NE-1000 sigue siendo el instrumento más preciso en términos de caudal, con un perfil de desviación global inferior al 2 %.</p><p>Evidentemente, la elección del instrumento y su precisión dependerán de su aplicación. Las bombas de jeringa de New Era Pump Systems son instrumentos robustos y de alto rendimiento, con una excelente relación calidad-precio.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>La bomba de jeringa es un dispositivo regulable que genera un caudal mediante el desplazamiento volumétrico del líquido en el cuerpo de la jeringa. El caudal se calcula en función de la sección transversal y la velocidad de movimiento del pistón: Q = S_{pistón} × ν_{pistón}. El…</p>\n","protected":false},"author":3,"featured_media":14795,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[67,24],"tags":[],"class_list":["post-14403","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-comparisons","category-flow-control"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Comparación entre New Era InfusionONE y SyringeONE</title>\n<meta name=\"description\" content=\"Nuestro objetivo aquí es comparar la precisión con la que las dos bombas de jeringa suministran el caudal.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Comparación entre New Era InfusionONE y SyringeONE\">\n<meta property=\"og:description\" content=\"Nuestro objetivo aquí es comparar la precisión con la que las dos bombas de jeringa suministran el caudal.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-22T14:27:38+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:12:54+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/NE-1000-New-Era-Darwin-Microfluidics.webp\">\n\t<meta property=\"og:image:width\" content=\"1000\">\n\t<meta property=\"og:image:height\" content=\"1000\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"4 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Comparison of New Era InfusionONE and SyringeONE\",\"datePublished\":\"2023-02-22T14:27:38+00:00\",\"dateModified\":\"2026-11-19T14:12:54+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/\"},\"wordCount\":500,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/NE-1000-New-Era-Darwin-Microfluidics.webp\",\"articleSection\":[\"Comparisons &amp; buying guides\",\"Flow control\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/\",\"url\":\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/\",\"name\":\"Comparison of New Era InfusionONE and SyringeONE\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/NE-1000-New-Era-Darwin-Microfluidics.webp\",\"datePublished\":\"2023-02-22T14:27:38+00:00\",\"dateModified\":\"2026-11-19T14:12:54+00:00\",\"description\":\"Nuestro objetivo aquí es comparar la precisión con la que las dos bombas de jeringa suministran el caudal.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/NE-1000-New-Era-Darwin-Microfluidics.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/NE-1000-New-Era-Darwin-Microfluidics.webp\",\"width\":1000,\"height\":1000},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Comparison of New Era InfusionONE and SyringeONE\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Nuestro blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/es\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Comparison of New Era InfusionONE and SyringeONE","description":"Nuestro objetivo aquí es comparar la precisión con la que las dos bombas de jeringa suministran el caudal.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/","og_locale":"en_US","og_type":"article","og_title":"Comparison of New Era InfusionONE and SyringeONE","og_description":"Our aim here is to compare the accuracy with which the two syringe pumps deliver the flow.","og_url":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T14:27:38+00:00","article_modified_time":"2026-11-19T14:12:54+00:00","og_image":[{"width":1000,"height":1000,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/NE-1000-New-Era-Darwin-Microfluidics.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"4 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Comparison of New Era InfusionONE and SyringeONE","datePublished":"2023-02-22T14:27:38+00:00","dateModified":"2026-11-19T14:12:54+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/"},"wordCount":500,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/NE-1000-New-Era-Darwin-Microfluidics.webp","articleSection":["Comparisons &amp; buying guides","Flow control"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/","url":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/","name":"Comparison of New Era InfusionONE and SyringeONE","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/NE-1000-New-Era-Darwin-Microfluidics.webp","datePublished":"2023-02-22T14:27:38+00:00","dateModified":"2026-11-19T14:12:54+00:00","description":"Nuestro objetivo aquí es comparar la precisión con la que las dos bombas de jeringa suministran el caudal.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/NE-1000-New-Era-Darwin-Microfluidics.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/NE-1000-New-Era-Darwin-Microfluidics.webp","width":1000,"height":1000},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/comparison-of-new-era-infusionone-and-syringeone/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Comparison of New Era InfusionONE and SyringeONE"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Nuestro blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/NE-1000-New-Era-Darwin-Microfluidics.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14403","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14403"}],"version-history":[{"count":18,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14403/revisions"}],"predecessor-version":[{"id":18437,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14403/revisions/18437"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14795"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14403"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14403"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14403"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}