{"id":27560,"date":"2024-08-26T17:21:41","date_gmt":"2024-08-26T15:21:41","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=27560"},"modified":"2026-11-19T15:26:11","modified_gmt":"2026-11-19T14:26:11","slug":"delrin-chemical-compatibility-chart","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/","title":{"rendered":"Delrin (polyoxymethylene) – Chemical Compatibility Chart"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"27560\" class=\"elementor elementor-27560\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2f1a789 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2f1a789\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-bae74a2\" data-id=\"bae74a2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-18fddb1 elementor-widget elementor-widget-text-editor\" data-id=\"18fddb1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>A la hora de seleccionar <a href=\"https://darwin-microfluidics.com/es/categorias/racores-y-conectores-microfluidicos/\"><strong>racores y conectores</strong></a> para aplicaciones <strong>microfluídicas</strong>, garantizar la compatibilidad química es fundamental para mantener la integridad y el rendimiento del sistema. <a href=\"https://darwin-microfluidics.com/es/categorias/racores-y-conectores-microfluidicos/?page=1&amp;rb_custom_field_eec34d804c9ce6c89cff596be555e6a4=Delrin\"><strong>El polioximetileno</strong></a>, un homopolímero de acetal conocido comúnmente como <a href=\"https://darwin-microfluidics.com/es/categorias/racores-y-conectores-microfluidicos/?page=1&amp;rb_custom_field_eec34d804c9ce6c89cff596be555e6a4=Delrin\"><strong>Delrin</strong></a>, se utiliza ampliamente en la fabricación de racores es y conectores debido a su extraordinario equilibrio de propiedades, que sirve de puente entre el metal y el plástico. El Delrin ofrece excelentes propiedades mecánicas, entre las que se incluyen <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">una</a> baja <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\" data-wg-splitted>absorción</a> de humedad, una alta resistencia a la tracción, resistencia a la fluencia y durabilidad. Su extrema resistencia química a los hidrocarburos, los disolventes y las sustancias químicas naturales lo hace ideal para entornos exigentes.</p>\n<p>Sin embargo, al igual que todos los materiales, el Delrin tiene sus limitaciones, y no todas las sustancias químicas son compatibles con él. Por lo tanto, comprender la compatibilidad es esencial para prevenir la degradación y garantizar la seguridad. En esta guía, presentamos una tabla exhaustiva de compatibilidad química para los racores y conectores de Delrin. Esta tabla, basada en los datos de compatibilidad química facilitados por <a href=\"https://www.idex-hs.com/resources/resources-detail/chemical-compatibility\" target=\"_blank\" rel=\"noopener\">IDEX</a>, está diseñada para ayudar a ingenieros, técnicos e investigadores a determinar rápidamente si el Delrin es adecuado para sus aplicaciones específicas, garantizando un rendimiento fiable y duradero en diversos entornos químicos.</p>\n<p>Consulte esta tabla para tomar decisiones informadas y mantener la eficiencia y la seguridad de su sistema.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-978a0ab elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"978a0ab\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-af28467\" data-id=\"af28467\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8a690f6 elementor-widget elementor-widget-text-editor\" data-id=\"8a690f6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>💡 La clave de clasificación de la compatibilidad química es la siguiente:</p><ul><li>A = Sin efecto o efecto mínimo</li><li>B = Efecto leve (decoloración o corrosión menor)</li><li>C = Efecto moderado a severo (No recomendado)</li></ul><p>🚨 <em>Las clasificaciones de compatibilidad proporcionadas en estas tablas son meramente orientativas y es posible que no sean completas ni precisas. No contemplan la posible contaminación ni las alteraciones en las propiedades de los fluidos derivadas de la interacción con el tube. No garantizamos la idoneidad de ningún material para aplicaciones específicas ni el impacto del tube en la calidad del fluido. Para aplicaciones críticas, realice pruebas específicas o consulte a un experto.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6a694e9 elementor-widget elementor-widget-text-editor\" data-id=\"6a694e9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 data-class=\"text-heading-default\">Accesorios y conectores de Delrin: Tabla de compatibilidad química</h2>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bd90aab elementor-widget elementor-widget-shortcode\" data-id=\"bd90aab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-59\" class=\"tablepress tablepress-id-59\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Sustancia química</th><th class=\"column-2\">Compatibilidad</th><th class=\"column-3\">Notas</th>\n</tr>\n</thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">A</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Ácido acético</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Acetona</td><td class=\"column-2\">A</td><td class=\"column-3\">Las temperaturas elevadas reducen la resistencia.</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Ácido adípico, 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Sulfato de aluminio, 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Cloruro de amonio, al 10 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Las temperaturas elevadas reducen la resistencia.</td>\n</tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Hidróxido de amonio, al 10 %</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Ortofosfato de amonio, al 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Tioglicolato de amonio, 8 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Anilina</td><td class=\"column-2\">B</td><td class=\"column-3\">Las temperaturas elevadas reducen la resistencia.</td>\n</tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">B</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Benceno</td><td class=\"column-2\">A</td><td class=\"column-3\">Las temperaturas elevadas reducen la resistencia.</td>\n</tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Líquido de frenos</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Líquido de frenos (Lockheed 21)</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Líquido de frenos (Super 9)</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Tampón con pH 10</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Tampón con pH 4</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Butilcarbitol</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">Butilaldehído</td><td class=\"column-2\">A</td><td class=\"column-3\">Las temperaturas elevadas reducen la resistencia.</td>\n</tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">Butilamina</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">C</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">Cloruro de calcio, al 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">Cloruro de calcio, 10%</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">Tetracloruro de carbono</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">Aceite de ricino</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">Acetato de cellosolve, 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-28\">\n\t<td class=\"column-1\">Cellosolve, 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-29\">\n\t<td class=\"column-1\">Cloro &gt;3 ppm</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-30\">\n\t<td class=\"column-1\">Limpiador (igepal), 1 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-31\">\n\t<td class=\"column-1\">Limpiador (igepal), 25 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-32\">\n\t<td class=\"column-1\">Cloruro de cobre, al 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-33\">\n\t<td class=\"column-1\">D</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-34\">\n\t<td class=\"column-1\">Dimetilformamida</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-35\">\n\t<td class=\"column-1\">Dioxano</td><td class=\"column-2\">B</td><td class=\"column-3\">Las temperaturas elevadas reducen la resistencia.</td>\n</tr>\n<tr class=\"row-36\">\n\t<td class=\"column-1\">E</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-37\">\n\t<td class=\"column-1\">Etanol</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-38\">\n\t<td class=\"column-1\">Acetato de etilo</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-39\">\n\t<td class=\"column-1\">Cloruro de etileno</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-40\">\n\t<td class=\"column-1\">F</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-41\">\n\t<td class=\"column-1\">Cloruro férrico, al 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-42\">\n\t<td class=\"column-1\">Cloruro ferroso, al 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-43\">\n\t<td class=\"column-1\">Formaldehído, 37 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-44\">\n\t<td class=\"column-1\">Ácido fórmico</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-45\">\n\t<td class=\"column-1\">Fungicida (captan), 5 g/cuarto de galón</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-46\">\n\t<td class=\"column-1\">G</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-47\">\n\t<td class=\"column-1\">Gasolina de alto octanaje</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-48\">\n\t<td class=\"column-1\">Gasolina normal</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-49\">\n\t<td class=\"column-1\">H</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-50\">\n\t<td class=\"column-1\">Hexano</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-51\">\n\t<td class=\"column-1\">Ácido clorhídrico, al 10 %</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-52\">\n\t<td class=\"column-1\">Peróxido de hidrógeno, al 1 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-53\">\n\t<td class=\"column-1\">Peróxido de hidrógeno, al 90 %</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-54\">\n\t<td class=\"column-1\">I</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-55\">\n\t<td class=\"column-1\">Insecticida (DDT), 2 cucharaditas por cuarto de galón</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-56\">\n\t<td class=\"column-1\">Insecticida (arseniato de plomo), 1 cucharadita por cuarto de galón</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-57\">\n\t<td class=\"column-1\">Insecticida (Malathlon, fosforo orgánico), 6 cucharaditas por cuarto de galón</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-58\">\n\t<td class=\"column-1\">Isooctano</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-59\">\n\t<td class=\"column-1\">Alcohol isoamílico</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-60\">\n\t<td class=\"column-1\">K</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-61\">\n\t<td class=\"column-1\">Queroseno</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-62\">\n\t<td class=\"column-1\">L</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-63\">\n\t<td class=\"column-1\">Lestoll, 0,25 tazas por galón</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-64\">\n\t<td class=\"column-1\">Drano líquido, 0,25 taza por galón</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-65\">\n\t<td class=\"column-1\">Cloruro de litio, 43 %</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-66\">\n\t<td class=\"column-1\">Lysol, 0,25 tazas por galón</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-67\">\n\t<td class=\"column-1\">M</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-68\">\n\t<td class=\"column-1\">Metanol</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-69\">\n\t<td class=\"column-1\">Metiletilcetona (MEK)</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-70\">\n\t<td class=\"column-1\">Cloruro de metilo</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-71\">\n\t<td class=\"column-1\">Salicilato de metilo</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-72\">\n\t<td class=\"column-1\">Aceite de motor</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-73\">\n\t<td class=\"column-1\">N</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-74\">\n\t<td class=\"column-1\">Sulfato de nicotina, 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-75\">\n\t<td class=\"column-1\">Ácido nítrico, al 10 %</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-76\">\n\t<td class=\"column-1\">O</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-77\">\n\t<td class=\"column-1\">Aceite (cárter)</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-78\">\n\t<td class=\"column-1\">Aceite, 10W30</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-79\">\n\t<td class=\"column-1\">P</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-80\">\n\t<td class=\"column-1\">Percloroetileno</td><td class=\"column-2\">B</td><td class=\"column-3\">Las temperaturas elevadas reducen la resistencia.</td>\n</tr>\n<tr class=\"row-81\">\n\t<td class=\"column-1\">Fenol</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-82\">\n\t<td class=\"column-1\">Ácido fosfórico, al 10 %</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-83\">\n\t<td class=\"column-1\">Permanganato potásico, al 10 %</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-84\">\n\t<td class=\"column-1\">Piridina</td><td class=\"column-2\">B</td><td class=\"column-3\">Las temperaturas elevadas reducen la resistencia.</td>\n</tr>\n<tr class=\"row-85\">\n\t<td class=\"column-1\">S</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-86\">\n\t<td class=\"column-1\">Bisulfato de sodio, al 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-87\">\n\t<td class=\"column-1\">Bisulfito de sodio, al 5 %</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-88\">\n\t<td class=\"column-1\">Bromato de sodio, 14 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-89\">\n\t<td class=\"column-1\">Bromuro de sodio, al 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-90\">\n\t<td class=\"column-1\">Clorato de sodio, al 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-91\">\n\t<td class=\"column-1\">Cloruro de sodio, 10 %</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-92\">\n\t<td class=\"column-1\">Hidróxido de sodio, al 10 %</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-93\">\n\t<td class=\"column-1\">Hipoclorito de sodio al 5%</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-94\">\n\t<td class=\"column-1\">Sulfuro de sodio, 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-95\">\n\t<td class=\"column-1\">Sulfito de sodio, 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-96\">\n\t<td class=\"column-1\">Tiosulfato de sodio, 26 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Las temperaturas elevadas reducen la resistencia.</td>\n</tr>\n<tr class=\"row-97\">\n\t<td class=\"column-1\">Cloruro de estaño (II), 5 %</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-98\">\n\t<td class=\"column-1\">Ácido sulfúrico, al 1 %</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-99\">\n\t<td class=\"column-1\">T</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-100\">\n\t<td class=\"column-1\">Ácido tartárico, 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-101\">\n\t<td class=\"column-1\">Tetrahidrofurano (THF)</td><td class=\"column-2\">A</td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-102\">\n\t<td class=\"column-1\">Tolueno</td><td class=\"column-2\">A</td><td class=\"column-3\">Las temperaturas elevadas reducen la resistencia.</td>\n</tr>\n<tr class=\"row-103\">\n\t<td class=\"column-1\">Trietilamina</td><td class=\"column-2\">A</td><td class=\"column-3\">Las temperaturas elevadas reducen la resistencia.</td>\n</tr>\n<tr class=\"row-104\">\n\t<td class=\"column-1\">U</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-105\">\n\t<td class=\"column-1\">Urea, 5 %</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-106\">\n\t<td class=\"column-1\">W</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-107\">\n\t<td class=\"column-1\">Herbicida (sulfamato-amato de amonio), 2 tazas por cuarto de galón</td><td class=\"column-2\">A</td><td class=\"column-3\">Solo a temperatura ambiente.</td>\n</tr>\n<tr class=\"row-108\">\n\t<td class=\"column-1\">Z</td><td class=\"column-2\"></td><td class=\"column-3\"></td>\n</tr>\n<tr class=\"row-109\">\n\t<td class=\"column-1\">Cloruro de zinc</td><td class=\"column-2\">C</td><td class=\"column-3\"></td>\n</tr>\n</tbody>\n</table>\n</div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5b46494 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5b46494\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f5c37c1\" data-id=\"f5c37c1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8e650eb elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"8e650eb\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"¿Necesitas ayuda con tu proyecto de microfluídica?\"><a href=\"https://darwin-microfluidics.com/es/contacto\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">¡Ponte en contacto con nuestros expertos!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">¿Necesitas ayuda con tu proyecto de microfluídica?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>¡Podemos facilitarte el uso de la microfluídica!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>A la hora de seleccionar accesorios y conectores para aplicaciones microfluídicas, garantizar la compatibilidad química es fundamental para mantener la integridad y el rendimiento del sistema. El polioximetileno, un homopolímero de acetal conocido comúnmente como Delrin, se utiliza ampliamente en accesorios y conectores debido a su excelente equilibrio de propiedades…</p>\n","protected":false},"author":4,"featured_media":27568,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[66,28,70],"tags":[],"class_list":["post-27560","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-chemical-compatibility","category-connectors-tubing","category-materials"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Delrin (polioximetileno) – Tabla de compatibilidad química</title>\n<meta name=\"description\" content=\"Explore la compatibilidad química del Delrin con diversas sustancias mediante nuestra tabla completa para lograr una selección de materiales y un rendimiento óptimos.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Delrin (polioximetileno) – Tabla de compatibilidad química\">\n<meta property=\"og:description\" content=\"Explore la compatibilidad química del Delrin con diversas sustancias mediante nuestra tabla completa para lograr una selección de materiales y un rendimiento óptimos.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-08-26T15:21:41+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:26:11+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/08/Delrin-plug.jpg\">\n\t<meta property=\"og:image:width\" content=\"1920\">\n\t<meta property=\"og:image:height\" content=\"1920\">\n\t<meta property=\"og:image:type\" content=\"image/jpeg\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"2 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"Delrin (polyoxymethylene) – Chemical Compatibility Chart\",\"datePublished\":\"2024-08-26T15:21:41+00:00\",\"dateModified\":\"2026-11-19T14:26:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/\"},\"wordCount\":301,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/08/Delrin-plug.jpg\",\"articleSection\":[\"Chemical compatibility charts\",\"Connectors &amp; tubing\",\"Materials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/\",\"url\":\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/\",\"name\":\"Delrin (polyoxymethylene) – Chemical Compatibility Chart\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/08/Delrin-plug.jpg\",\"datePublished\":\"2024-08-26T15:21:41+00:00\",\"dateModified\":\"2026-11-19T14:26:11+00:00\",\"description\":\"Explore la compatibilidad química del Delrin con diversas sustancias mediante nuestra tabla completa para lograr una selección de materiales y un rendimiento óptimos.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/08/Delrin-plug.jpg\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/08/Delrin-plug.jpg\",\"width\":1920,\"height\":1920,\"caption\":\"Delrin plug\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Delrin (polyoxymethylene) – Chemical Compatibility Chart\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Nuestro blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/es\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Delrin (polyoxymethylene) – Chemical Compatibility Chart","description":"Explore la compatibilidad química del Delrin con diversas sustancias mediante nuestra tabla completa para lograr una selección de materiales y un rendimiento óptimos.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/","og_locale":"en_US","og_type":"article","og_title":"Delrin (polyoxymethylene) – Chemical Compatibility Chart","og_description":"Explore Delrin's chemical compatibility with various substances using our comprehensive chart for optimal material selection and performance.","og_url":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-08-26T15:21:41+00:00","article_modified_time":"2026-11-19T14:26:11+00:00","og_image":[{"width":1920,"height":1920,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/08/Delrin-plug.jpg","type":"image/jpeg"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"2 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"Delrin (polyoxymethylene) – Chemical Compatibility Chart","datePublished":"2024-08-26T15:21:41+00:00","dateModified":"2026-11-19T14:26:11+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/"},"wordCount":301,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/08/Delrin-plug.jpg","articleSection":["Chemical compatibility charts","Connectors &amp; tubing","Materials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/","url":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/","name":"Delrin (polyoxymethylene) – Chemical Compatibility Chart","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/08/Delrin-plug.jpg","datePublished":"2024-08-26T15:21:41+00:00","dateModified":"2026-11-19T14:26:11+00:00","description":"Explore la compatibilidad química del Delrin con diversas sustancias mediante nuestra tabla completa para lograr una selección de materiales y un rendimiento óptimos.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/08/Delrin-plug.jpg","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/08/Delrin-plug.jpg","width":1920,"height":1920,"caption":"Delrin plug"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/delrin-chemical-compatibility-chart/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Delrin (polyoxymethylene) – Chemical Compatibility Chart"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Nuestro blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/08/Delrin-plug.jpg","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/27560","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=27560"}],"version-history":[{"count":29,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/27560/revisions"}],"predecessor-version":[{"id":33676,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/27560/revisions/33676"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/27568"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=27560"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=27560"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=27560"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}