{"id":28862,"date":"2024-10-01T17:21:51","date_gmt":"2024-10-01T15:21:51","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=28862"},"modified":"2026-11-19T15:26:58","modified_gmt":"2026-11-19T14:26:58","slug":"instructions-for-appropriate-handling-of-the-bp7-micropumps","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/","title":{"rendered":"Instructions for Appropriate Handling of the BP7 Micropumps"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"28862\" class=\"elementor elementor-28862\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4f36fa7 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4f36fa7\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4b0d991\" data-id=\"4b0d991\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-647c10c elementor-widget elementor-widget-text-editor\" data-id=\"647c10c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La manipulación adecuada de las <a href=\"https://darwin-microfluidics.com/es/productos/bartels-bp7-micropump/\">micropompas Bartels BP7</a> es fundamental para garantizar su rendimiento óptimo y su longevidad. Estas micropompas piezoeléctricas, desarrolladas por <a href=\"https://bartels-mikrotechnik.de/\" target=\"_blank\" rel=\"noopener\">Bartels Mikrotechnik</a>, representan un avance en la tecnología microfluídica, ya que proporcionan una solución compacta, eficiente y fiable para la gestión de líquidos y gases. Sin embargo, para aprovechar al máximo su potencial y evitar problemas operativos comunes, los usuarios deben seguir directrices específicas relativas a la instalación, la puesta en marcha, el funcionamiento y el mantenimiento.</p>\n<p>Aunque el manual del BP7 ofrece información muy útil, es posible que, al leerlo por encima, se pasen por alto algunos consejos e instrucciones fundamentales (🚨). En esta entrada del blog, destacaremos estos aspectos importantes (consejos relacionados con la mecánica, la electricidad, los fluidos y el software), ofreciendo orientación práctica que te ayude no solo a cumplir con las instrucciones generales, sino también a resolver algunos problemas.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-43ad5ee elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"43ad5ee\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-06e6182\" data-id=\"06e6182\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ea5e715 elementor-widget elementor-widget-heading\" data-id=\"ea5e715\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">⚙️ Instrucciones mecánicas para la micropompa BP7\n</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-66e1d65 elementor-widget elementor-widget-heading\" data-id=\"66e1d65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Manipulación del cable flexible\n</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5443a57 elementor-widget elementor-widget-text-editor\" data-id=\"5443a57\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"letter-spacing: -0.16px; color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1rem;\">🚨 </span>El cable flexible de la micropompa BP7 es delicado y debe manipularse con cuidado. Evite doblarlo o retorcerlo, especialmente alrededor de bordes afilados, para prevenir daños. Asegure la micropompa y la conexión del enchufe para reducir el estrés mecánico provocado por las vibraciones.</p><p><span style=\"letter-spacing: -0.16px; color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1rem;\">🚨 </span>El conector está diseñado para soportar unos 30 ciclos de conexión y desconexión, por lo que debe sustituirse regularmente para garantizar un rendimiento fiable.</p><p>🚨 No modifique el cable flexible, ya que hacerlo puede comprometer su funcionalidad y anular la garantía.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3b71760 elementor-widget elementor-widget-image\" data-id=\"3b71760\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"328\" height=\"121\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Do-not-bend-the-flex-cable.png\" class=\"attachment-large size-large wp-image-28979\" alt=\"No doble el cable flexible\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Do-not-bend-the-flex-cable.png 328w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Do-not-bend-the-flex-cable-300x111.png 300w\" sizes=\"(max-width: 328px) 100vw, 328px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f539a88 elementor-widget elementor-widget-heading\" data-id=\"f539a88\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Compatibilidad de la bomba</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cdd4e76 elementor-widget elementor-widget-text-editor\" data-id=\"cdd4e76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"letter-spacing: -0.16px; color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1rem;\">🚨 </span><span style=\"font-weight: 400;\">El rendimiento de la micropompa BP7 puede verse afectado por la <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">absorción</a> de moléculas de líquido, lo que puede alterar las propiedades mecánicas de sus componentes internos. Aunque este cambio puede influir en el proceso de bombeo, es importante señalar que el efecto es reversible y la bomba no sufre daños permanentes.</span></p><p>La siguiente tabla muestra la compatibilidad de la bomba con diferentes líquidos tras mediciones a largo plazo durante dos semanas a 250Vpp/100Hz.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef5dc59 elementor-widget elementor-widget-shortcode\" data-id=\"ef5dc59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-69\" class=\"tablepress tablepress-id-69\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Sustancia química</th><th class=\"column-2\">Concentración (%)</th><th class=\"column-3\">Compatibilidad química de la PPSU</th>\n</tr>\n</thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Ácido acético</td><td class=\"column-2\">100</td><td class=\"column-3\">F</td>\n</tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Acetona</td><td class=\"column-2\">100</td><td class=\"column-3\">X</td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Gasolina de limpieza</td><td class=\"column-2\">100</td><td class=\"column-3\">F</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Etanol</td><td class=\"column-2\">100</td><td class=\"column-3\">X</td>\n</tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Acetato de etilo</td><td class=\"column-2\">100</td><td class=\"column-3\">X</td>\n</tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Glicerina</td><td class=\"column-2\">60</td><td class=\"column-3\">E</td>\n</tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Isopropanol</td><td class=\"column-2\">100</td><td class=\"column-3\">F</td>\n</tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Metanol</td><td class=\"column-2\">100</td><td class=\"column-3\">X</td>\n</tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Hidróxido de sodio</td><td class=\"column-2\">0.2</td><td class=\"column-3\">E</td>\n</tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Aceite para bombas de vide</td><td class=\"column-2\">100</td><td class=\"column-3\">G</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-69 from cache -->\n<tr>\n    <td colspan=\"2\">\n      <strong>Notas:</strong><br>\n      <span style=\"color: red;\">E</span> = Excelente; Efecto nulo o mínimo.<br>\n      <span style=\"color: red;\">G</span> = Bueno; Sin pérdida grave de propiedades.<br>\n<span style=\"color: red;\">F</span> = Aceptable; Algunos efectos negativos, se conservan algunas propiedades útiles.<br>\n<span style=\"color: red;\">X</span> = Deficiente; Ataque severo o rotura.\n    </td>\n</tr></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ebd7cee elementor-widget elementor-widget-heading\" data-id=\"ebd7cee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Compatibilidad química del PPSU</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59854d0 elementor-widget elementor-widget-text-editor\" data-id=\"59854d0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>El cuerpo de la micropompa BP7, fabricado en PPSU (polifenilsulfona), ofrece una excelente resistencia a los ácidos diluidos, las soluciones alcalinas y muchos disolventes orgánicos. Sin embargo, es menos resistente a los ácidos concentrados y a las cetonas. Para consultar la compatibilidad química detallada, consulte nuestra <a href=\"https://blog.darwin-microfluidics.com/ppsu-polyphenylsulfone-chemical-compatibility-chart/\">guía completa</a>.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-243d6d1 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"243d6d1\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-997a08c\" data-id=\"997a08c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9b902e4 elementor-widget elementor-widget-heading\" data-id=\"9b902e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">⚡ Instrucciones eléctricas para la micropompa BP7\n</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a615abf elementor-widget elementor-widget-heading\" data-id=\"a615abf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Precauciones de conexión y manipulación\n</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63cd9ac elementor-widget elementor-widget-text-editor\" data-id=\"63cd9ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Una conexión incorrecta o una manipulación inadecuada pueden provocar fallos en la bomba o en los componentes electrónicos. Por lo tanto, es fundamental mantener una conexión segura entre la micropompa y el conector de la placa.</p><p>🚨 Al conectar el driver de la bomba (mp-Lowdriver, mp-Highdriver, mp-Highdriver4, mp-Driver, mp-Valvedriver), alinee el <strong>punto blanco en la esquina superior izquierda del driver</strong> con el <strong>marcador blanco en la mp-Multiboard2</strong> para ubicar correctamente el Pin 1.</p><p>🚨 Manipule con cuidado el driver de la bomba al retirarlo para evitar doblar los pines y afectar a su funcionalidad.</p><p>🚨 Limite la longitud del cable entre el controlador y la bomba a un máximo de 1 metro para garantizar un rendimiento óptimo.</p><p>🚨 Inserte el cable de la bomba en el conector con las <strong>superficies de contacto hacia abajo</strong>; una orientación incorrecta impedirá que la bomba funcione. Asegure la conexión cerrando el conector blanco. Para desconectar, abra primero el conector Molex.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-562ca31 elementor-widget elementor-widget-image\" data-id=\"562ca31\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"275\" height=\"418\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Good-Connection.png\" class=\"attachment-large size-large wp-image-28981\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Good-Connection.png 275w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Good-Connection-197x300.png 197w\" sizes=\"(max-width: 275px) 100vw, 275px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb0f254 elementor-widget elementor-widget-heading\" data-id=\"bb0f254\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Protección contra factores ambientales</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77c10da elementor-widget elementor-widget-text-editor\" data-id=\"77c10da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>🚨 Asegúrese de que la toma de tierra esté conectada correctamente antes de aplicar la tensión de alimentación para evitar daños, ya que los chips de los driver son sensibles a las descargas electrostáticas.</p><p>🚨 <strong>Evite tocar los controles durante el funcionamiento</strong>, ya que operan a altos voltajes y el contacto puede provocar lesiones o daños en el equipo.</p><p>🚨 Evite cualquier contacto entre el cable flexible, los conectores o la electrónica de la micropompa con líquidos o humedad, ya que esto puede provocar cortocircuitos y fallos en la bomba.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1814db3 elementor-widget elementor-widget-heading\" data-id=\"1814db3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Gestión de energía y temperatura</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-af991bd elementor-widget elementor-widget-text-editor\" data-id=\"af991bd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>🚨 Si se requiere más corriente, conecte una fuente de alimentación externa a través del conector USB-C.</p><p>🚨 Asegúrese de que la plataforma Highdriver funcione por debajo de 160 °C para evitar que entre en modo de no funcionamiento.</p><p>🚨 Utilice <strong>señales rectangulares de flancos cuadrados</strong> brevemente para evitar un estrés mecánico excesivo en los piezoactuadores, lo que podría provocar el fallo de la bomba.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4132294 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4132294\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-736529d\" data-id=\"736529d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b37aa50 elementor-widget elementor-widget-heading\" data-id=\"b37aa50\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">💻 Instrucciones de software para la micropompa BP7</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24321cd elementor-widget elementor-widget-heading\" data-id=\"24321cd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Detección y activación de canales</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-809a35e elementor-widget elementor-widget-text-editor\" data-id=\"809a35e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Tras instalar con éxito el driver usb, la aplicación Multiboard2 detectará automáticamente el driver conectado y habilitará los canales correspondientes:</p><ul><li><strong>Highdriver4</strong>: Habilita los canales <strong>CH1 a CH4</strong>.</li><li><strong>mp-Highdriver</strong>: Permite el control del canal <strong>CH5</strong> únicamente.</li><li><strong>mp-Lowdriver</strong>: Permite el control del canal <strong>CH5</strong> únicamente.</li><li><strong>mp-Driver</strong>: Habilita el canal <strong>CH6</strong> únicamente.</li></ul><p> 🚨 Por ejemplo, al utilizar el Lowdriver para controlar una bomba BP7, esta bomba debe conectarse a CH5 en la Multiboard2.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bc0518f elementor-widget elementor-widget-heading\" data-id=\"bc0518f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Instalación del usb drive (Windows)</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-52741b2 elementor-widget elementor-widget-text-editor\" data-id=\"52741b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>🚨 Si su PC no reconoce automáticamente el microcontrolador ESP32, deberá instalar el usb drive de forma manual. Siga estos pasos:</p><ol><li>Visite el sitio web de Bartels y vaya a la <a href=\"https://bartels-mikrotechnik.de/download-area-en/\" target=\"_blank\" rel=\"noopener\">sección de descargas</a>.</li><li>Descargue el archivo mp-Multiboard2_USB_Driver.zip.</li><li>Descomprima el archivo y haga clic con el botón derecho en el archivo de información de configuración <strong>silabser.inf</strong>.</li><li>Seleccione Instalar en el menú contextual para instalar los drivers en su dispositivo.</li></ol>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-27aee45 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"27aee45\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8072e60\" data-id=\"8072e60\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-cce9aad elementor-widget elementor-widget-heading\" data-id=\"cce9aad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">💧 Instrucciones fluídicas para la micropompa BP7</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-460968c elementor-widget elementor-widget-heading\" data-id=\"460968c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Conexión de tube</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b2f232 elementor-widget elementor-widget-text-editor\" data-id=\"9b2f232\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>🚨 Conecte los tube adecuados a la entrada y salida de la micropompa BP7. Bartels Mikrotechnik recomienda utilizar <strong>Tygon LMT-55</strong> para soluciones acuosas o <strong>F4040</strong> para disolventes, ambos con un <strong>diámetro interior (ID) de 1,3 mm</strong> y un diámetro exterior (OD) de 3 mm.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd985c1 elementor-widget elementor-widget-heading\" data-id=\"dd985c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Conexiones en paralelo y en serie</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9563a91 elementor-widget elementor-widget-text-editor\" data-id=\"9563a91\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>🚨 Configure las micropompas BP7 en conexiones en paralelo o en serie según los requisitos de su aplicación:</p><ul><li>Para un mayor caudal, conecte varias bombas en paralelo con el fin de incrementar el caudal total.</li><li>Para aplicaciones que requieran una presión elevada, conecte las bombas en serie para aumentar la presión máxima del sistema.</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2f9a255 elementor-widget elementor-widget-image\" data-id=\"2f9a255\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"314\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Series-Parallel-1024x502.png\" class=\"attachment-large size-large wp-image-28980\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Series-Parallel-1024x502.png 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Series-Parallel-300x147.png 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Series-Parallel-768x377.png 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Series-Parallel.png 1150w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Micropompas BP7 configuradas en conexiones en serie y en paralelo respectivamente.</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd46a46 elementor-widget elementor-widget-heading\" data-id=\"dd46a46\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Limpieza de la micropomba</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea3cffb elementor-widget elementor-widget-text-editor\" data-id=\"ea3cffb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>🚨 Para limpiar a fondo la micropomba BP7, utilice alcohol isopropílico (IPA). Puede aspirar IPA a través del sistema utilizando una jeringa desde la salida o hacer funcionar la micropomba con IPA o etanol durante varios minutos. Después de la limpieza, enjuague la micropomba con agua destilada para eliminar cualquier residuo de alcohol de los canales y cámaras de la bomba.</p><p>🚨 Enjuague siempre en la dirección de funcionamiento de la bomba, ya que se prefiere la presión negativa en la salida frente a la presión positiva en la entrada.</p><p>🚨 Enjuague o llene siempre la micropomba BP7 desde la salida (succión) para evitar superar la presión máxima de 1 bar, lo que podría provocar un fallo de la bomba.</p><p>🚨 Manipule la micropomba en un entorno limpio y utilice filtros para prevenir la contaminación. Asegúrese de bombear únicamente líquidos con tamaños de partícula inferiores a 50 μm, ya que las partículas más grandes pueden perjudicar su funcionalidad.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ccdf91 elementor-widget elementor-widget-heading\" data-id=\"5ccdf91\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Cebado de la micropomba</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea2d0cb elementor-widget elementor-widget-text-editor\" data-id=\"ea2d0cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>🚨 Para cebar la micropomba BP7 para el transporte de líquidos y gases:</p><ul><li>Comience con el voltaje más alto y una frecuencia de al menos 300 Hz para eliminar el aire del sistema. Una vez que el líquido llegue a la micropomba, reduzca la frecuencia a 100 Hz para obtener un rendimiento óptimo.</li><li>Para el cebado manual, aplique presión negativa en la salida utilizando una jeringa o conecte una bomba externa (por ejemplo, una segunda BP7) para cebar la primera BP7.</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b7c880d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b7c880d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cfad54c\" data-id=\"cfad54c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0b0ef8e elementor-widget elementor-widget-heading\" data-id=\"0b0ef8e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusión</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ae7a8ed elementor-widget elementor-widget-text-editor\" data-id=\"ae7a8ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Manejar la micropomba BP7 con cuidado es clave para aprovecharla al máximo. Al prestar atención a los consejos e instrucciones —ya sea realizar conexiones seguras, mantener la bomba limpia o configurarla correctamente— garantizará un funcionamiento más fluido y un Longer tiempo de vida útil. Los pasos sencillos pueden marcar una gran diferencia. Con estos consejos prácticos, puede evitar problemas comunes y sacar el máximo provecho de su micropomba BP7 en cualquier aplicación.</p><p>Para obtener una visión general más detallada de la micropompa BP7, su gama completa de características y los componentes del sistema, consulte nuestro <a href=\"https://blog.darwin-microfluidics.com/bartels-bp7-piezoelectric-micropumps-an-overview/\">blog de presentación de la Bartels BP7</a>. También encontrará otras guías útiles en esta serie, incluidas publicaciones detalladas sobre temas como la <a href=\"https://blog.darwin-microfluidics.com/bartels-mp-multiboard2-and-comparison-of-the-mp-drivers/\">mp-Multiboard2 y los mp-Drivers</a>, y más información sobre cómo controlar la BP7 con la aplicación Multiboard2.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6fa68d9 elementor-widget elementor-widget-text-editor\" data-id=\"6fa68d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>📧 Si tiene alguna pregunta o comentario, no dude en ponerse en contacto con nosotros en <a href=\"https://darwin-microfluidics.com/es/pages/contacto\">support@darwin-microfluidics.com.</a></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0eaa8b3 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"0eaa8b3\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"¿Necesitas ayuda con tu proyecto de microfluídica?\"><a href=\"https://darwin-microfluidics.com/es/contacto\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">¡Ponte en contacto con nuestros expertos!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">¿Necesitas ayuda con tu proyecto de microfluídica?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>¡Podemos facilitarte el uso de la microfluídica!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Proper handling of the Bartels BP7 micropumps is essential to ensure their optimal performance and longevity. These piezoelectric micropumps, developed by Bartels Mikrotechnik, represent a breakthrough in microfluidic technology, providing a compact, efficient, and reliable solution for managing liquids and…</p>\n","protected":false},"author":4,"featured_media":28864,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[24,33],"tags":[],"class_list":["post-28862","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-control","category-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Instrucciones para la manipulación adecuada del BP7 microbombas</title>\n<meta name=\"description\" content=\"Conozca las directrices esenciales para la manipulación y el funcionamiento seguros de las micropompas BP7, garantizando un rendimiento óptimo y una larga vida útil.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Instrucciones para la manipulación adecuada del BP7 microbombas\">\n<meta property=\"og:description\" content=\"Conozca las directrices esenciales para la manipulación y el funcionamiento seguros de las micropompas BP7, garantizando un rendimiento óptimo y una larga vida útil.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-10-01T15:21:51+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:26:58+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/09/Instructions.png\">\n\t<meta property=\"og:image:width\" content=\"283\">\n\t<meta property=\"og:image:height\" content=\"207\">\n\t<meta property=\"og:image:type\" content=\"image/png\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"7 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"Instructions for Appropriate Handling of the BP7 Micropumps\",\"datePublished\":\"2024-10-01T15:21:51+00:00\",\"dateModified\":\"2026-11-19T14:26:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/\"},\"wordCount\":1231,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/09/Instructions.png\",\"articleSection\":[\"Flow control\",\"Guides &amp; tutorials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/\",\"url\":\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/\",\"name\":\"Instructions for Appropriate Handling of the BP7 Micropumps\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/09/Instructions.png\",\"datePublished\":\"2024-10-01T15:21:51+00:00\",\"dateModified\":\"2026-11-19T14:26:58+00:00\",\"description\":\"Conozca las directrices esenciales para la manipulación y el funcionamiento seguros de las micropompas BP7, garantizando un rendimiento óptimo y una larga vida útil.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/09/Instructions.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/09/Instructions.png\",\"width\":283,\"height\":207,\"caption\":\"Instructions\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Instructions for Appropriate Handling of the BP7 Micropumps\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Nuestro blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/es\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Instructions for Appropriate Handling of the BP7 Micropumps","description":"Conozca las directrices esenciales para la manipulación y el funcionamiento seguros de las micropompas BP7, garantizando un rendimiento óptimo y una larga vida útil.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/","og_locale":"en_US","og_type":"article","og_title":"Instructions for Appropriate Handling of the BP7 Micropumps","og_description":"Learn essential guidelines for safely handling and operating BP7 Micropumps, ensuring optimal performance and longevity.","og_url":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-10-01T15:21:51+00:00","article_modified_time":"2026-11-19T14:26:58+00:00","og_image":[{"width":283,"height":207,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/09/Instructions.png","type":"image/png"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"7 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"Instructions for Appropriate Handling of the BP7 Micropumps","datePublished":"2024-10-01T15:21:51+00:00","dateModified":"2026-11-19T14:26:58+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/"},"wordCount":1231,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/09/Instructions.png","articleSection":["Flow control","Guides &amp; tutorials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/","url":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/","name":"Instructions for Appropriate Handling of the BP7 Micropumps","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/09/Instructions.png","datePublished":"2024-10-01T15:21:51+00:00","dateModified":"2026-11-19T14:26:58+00:00","description":"Conozca las directrices esenciales para la manipulación y el funcionamiento seguros de las micropompas BP7, garantizando un rendimiento óptimo y una larga vida útil.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/09/Instructions.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/09/Instructions.png","width":283,"height":207,"caption":"Instructions"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/instructions-for-appropriate-handling-of-the-bp7-micropumps/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Instructions for Appropriate Handling of the BP7 Micropumps"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Nuestro blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/09/Instructions.png","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/28862","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=28862"}],"version-history":[{"count":110,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/28862/revisions"}],"predecessor-version":[{"id":29347,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/28862/revisions/29347"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/28864"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=28862"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=28862"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=28862"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}