{"id":14296,"date":"2023-02-22T11:23:19","date_gmt":"2023-02-22T10:23:19","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14296"},"modified":"2024-02-27T12:12:58","modified_gmt":"2024-02-27T11:12:58","slug":"step-emulsification-for-high-throughput-droplet-generation-a-review","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/","title":{"rendered":"Step emulsification for high-throughput droplet generation: a review"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14296\" class=\"elementor elementor-14296\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5195888 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5195888\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6ac86e1\" data-id=\"6ac86e1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0f534f3 elementor-widget elementor-widget-text-editor\" data-id=\"0f534f3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L'émulsification par étapes est une variante de la technique de génération de gouttelettes dite « co-flow ». Cette nouvelle technique repose sur l'instabilité d'un fil liquide biphasique provoquée par un changement brusque du confinement de l'écoulement (figure 1). Elle s'inspire plus directement de l'émulsification <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">par microcanaux</a>, puisqu'elle utilise des réseaux d'canal s microfabriqués qui permettent un contrôle géométrique extrêmement précis de la taille des gouttelettes.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a511b2 elementor-widget elementor-widget-image\" data-id=\"5a511b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"160\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1-300x160.webp\" class=\"attachment-medium size-medium wp-image-14298\" alt=\"Illustration schématique d'un canal d'émulsification par étape\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1-300x160.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp 660w\" sizes=\"(max-width: 300px) 100vw, 300px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1 : Illustration schématique d'un canal d'émulsification par étape. La rupture de goutte se produit à l'étape entre la buse et le canal de phase continue. Ofner et al. 2016 Macromol. Chem. Phys.</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8294f01 elementor-widget elementor-widget-text-editor\" data-id=\"8294f01\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Mécanisme d'émulsification par étapes</h2><p>La technique d’émulsification par étapes est utilisée pour générer des gouttelettes dont le diamètre varie de quelques nanomètres à plusieurs centaines de micromètres. Pour mettre en œuvre ce procédé, l’équipement nécessaire comprend un canal de la phase dispersée, un réservoir de la phase continue et une buse dont la hauteur diffère considérablement de celle de l’ réservoir.</p><p>Pour caractériser cette technique, plusieurs modèles géométriques ont été établis. Parmi ces modèles, c'est le mécanisme quasi-statique qui a été retenu par la plupart des chercheurs pour comprendre comment les gouttes sont générées. Selon Dangla et al. 2013 J Phys D Appl Phys, ce modèle est conditionné par trois hypothèses :</p><ol><li>la phase dispersée n'est pas capable de mouiller les parois du canal pour la formation de gouttelettes,</li><li>l'effet gravitationnel est négligeable,</li><li>le système évolue de manière quasi-statique.</li></ol><p>Pour réussir à générer des gouttelettes par émulsification par paliers, la phase continue contenant l’ surfactant doit être injectée en premier afin de remplir l’ réservoir. La phase dispersée non miscible est ensuite injectée dans l’ canal. Ainsi, à mesure que le filet de la phase dispersée traverse le palier, une bulle se forme en aval de celui-ci. Au fur et à mesure que la phase dispersée est injectée en continu, la courbure moyenne de la bulle diminue, tandis que sa taille augmente (figure 2).</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03cc5a1 elementor-widget elementor-widget-image\" data-id=\"03cc5a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"260\" height=\"221\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-section_views_of_the_nozzle_in_two_lateral_direction-1.webp\" class=\"attachment-medium size-medium wp-image-14302\" alt=\"\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 2: Vues en coupe de la buse dans deux directions latérales. I. La phase dispersée est injectée dans la buse. II. Le rayon du bulbe atteint la valeur critique et commence à former la région de striction. III. Le diamètre du col diminue jusqu'à la hauteur de la buse après striction. IV. La gouttelette se détache de la phase dispersée dans la phase continue. Shi et al. 2020. R. Soc. Chem.</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-348c523 elementor-widget elementor-widget-global elementor-global-18298 elementor-widget-pix-promo-box\" data-id=\"348c523\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Droplet-generators_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"VOUS SOUHAITEZ SIMPLIFIER LA GÉNÉRATION DE GOUTTELETTES EN MICROFLUIDIQUE ?\"><a href=\"https://darwin-microfluidics.com/fr/collections/controleur-de-pression/produits/ob1-droplet-pack-microfluidique\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Découvrez notre sélection !</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">VOUS SOUHAITEZ SIMPLIFIER LA GÉNÉRATION DE GOUTTELETTES EN MICROFLUIDIQUE ?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Libérez le potentiel de nos systèmes user-friendly pour une génération de gouttelettes sans effort</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08c8378 elementor-widget elementor-widget-text-editor\" data-id=\"08c8378\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Types de procédés d'émulsification par étapes</h2><p>L'étape d'émulsification en <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microcanal</a> de type rainuré est régie par la tension interfaciale pour la formation de gouttelettes lors de l'utilisation de la pression ou du débit. Classiquement, le <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microcanal</a> rainuré comprend un canal de phase dispersée, une buse, une terrasse et un réservoir de phase continue (Figure 3a). Ce type de dispositif peut être fabriqué sur une plaquette de silicium par <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/photolithography-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">photolithographie</a> et gravure dépendante de l'orientation.</p><p>Un deuxième exemple est l'utilisation d'un <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microcanal</a> droit pour l'émulsification par étapes, dont la structure comprend des trous droits allongés pour la formation de gouttelettes (Figure 3b). Le diamètre des gouttelettes est linéairement lié à la profondeur du trou droit, qui est approximativement un multiple de 4. Pour la fabrication de ce dispositif, la gravure ionique réactive profonde (DRIE) sur une tranche de silicium peut être utilisée.</p><p>Une autre structure d'émulsification par étapes permettant la génération de gouttelettes à des débits élevés est le dispositif de génération de gouttelettes Edge (EDGE). Cette fois, il ne s'agira plus d'un trou droit, mais d'un large plateau peu profond servant de buse, dans lequel des gouttelettes parallèles sont générées simultanément à partir d'une seule buse (Figure 3c). Pour fabriquer ce dispositif, une tranche de silicium est gravée en utilisant la technique de gravure ionique réactive profonde (DRIE), puis liée à une plaque de verre.</p><p>Jusqu'à présent, seules des buses rectangulaires ont été utilisées dans les dispositifs susmentionnés. Cependant, les buses triangulaires ont démontré des performances bien supérieures. La buse triangulaire agit alors comme une terrasse pour le reflux de la phase continue avec la section transversale étirée (Figure 3d). De cette manière, la buse triangulaire offre une zone locale indépendante pour la formation de gouttelettes afin d'éviter toute interférence indésirable des phases dispersée et continue.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b7a3925 elementor-widget elementor-widget-image\" data-id=\"b7a3925\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"148\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_of_microfluidic_step_emulsification_devices-1.webp\" class=\"attachment-medium_large size-medium_large wp-image-14303\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_of_microfluidic_step_emulsification_devices-1.webp 704w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_of_microfluidic_step_emulsification_devices-1-300x69.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63c206b elementor-widget elementor-widget-text-editor\" data-id=\"63c206b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>En émulsification par étapes, il est important de noter que la taille des gouttelettes monodisperses est liée aux caractérisations géométriques du <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microcanal</a>, ce qui signifie que le diamètre des gouttelettes est difficile à ajuster une fois le <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microcanal</a> conçu.</p><p>Bien que limitée en taille de gouttelettes par la géométrie, l'émulsification par étapes est un outil robuste, surtout lorsqu'elle est combinée aux technologies de détection, d'identification et d'information, ce qui améliorera la mesure de la bio-information.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b68076 elementor-widget elementor-widget-global elementor-global-18301 elementor-widget-pix-promo-box\" data-id=\"5b68076\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Droplet-generators_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"VOUS SOUHAITEZ AUGMENTER VOTRE PRODUCTION DE GOUTTELETTES ?\"><div class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Découvrez notre sélection !</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">VOUS SOUHAITEZ AUGMENTER VOTRE PRODUCTION DE GOUTTELETTES ?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explorez nos solutions évolutives conçues pour répondre facilement aux exigences de la génération de gouttelettes à haut débit.</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></div></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>The step emulsification is a variant of the droplet generation technique called co-flow. This new technique is based on the instability of a two-phase liquid wire triggered by an abrupt change in the flow confinement (Figure 1). It is more…</p>\n","protected":false},"author":3,"featured_media":14298,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[23,21],"tags":[],"class_list":["post-14296","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-droplet-generation","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Émulsification par étapes pour la production de gouttelettes à haut débit : une synthèse</title>\n<meta name=\"description\" content=\"L'émulsification par étapes est une variante de la génération de gouttelettes. Cette technique permet un débit élevé de petites gouttelettes. Découvrez comment !\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Émulsification par étapes pour la production de gouttelettes à haut débit : une synthèse\">\n<meta property=\"og:description\" content=\"L'émulsification par étapes est une variante de la génération de gouttelettes. Cette technique permet un débit élevé de petites gouttelettes. Découvrez comment !\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-22T10:23:19+00:00\">\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:12:58+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp\">\n\t<meta property=\"og:image:width\" content=\"660\">\n\t<meta property=\"og:image:height\" content=\"351\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"4 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Step emulsification for high-throughput droplet generation: a review\",\"datePublished\":\"2023-02-22T10:23:19+00:00\",\"dateModified\":\"2024-02-27T11:12:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\"},\"wordCount\":745,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"articleSection\":[\"Droplet generation\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\",\"url\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\",\"name\":\"Step emulsification for high-throughput droplet generation: a review\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"datePublished\":\"2023-02-22T10:23:19+00:00\",\"dateModified\":\"2024-02-27T11:12:58+00:00\",\"description\":\"L'émulsification par étapes est une variante de la génération de gouttelettes. Cette technique permet un débit élevé de petites gouttelettes. Découvrez comment !\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"width\":660,\"height\":351,\"caption\":\"Schematic illustration of a step emulsification channel\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Step emulsification for high-throughput droplet generation: a review\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Notre blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/fr\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Step emulsification for high-throughput droplet generation: a review","description":"L'émulsification par étapes est une variante de la génération de gouttelettes. Cette technique permet un débit élevé de petites gouttelettes. Découvrez comment !","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/","og_locale":"en_US","og_type":"article","og_title":"Step emulsification for high-throughput droplet generation: a review","og_description":"Step emulsification is a variant of droplet generation. This technique allows a high throughput of small droplets. Find out how!","og_url":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T10:23:19+00:00","article_modified_time":"2024-02-27T11:12:58+00:00","og_image":[{"width":660,"height":351,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"4 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Step emulsification for high-throughput droplet generation: a review","datePublished":"2023-02-22T10:23:19+00:00","dateModified":"2024-02-27T11:12:58+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/"},"wordCount":745,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","articleSection":["Droplet generation","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/","url":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/","name":"Step emulsification for high-throughput droplet generation: a review","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","datePublished":"2023-02-22T10:23:19+00:00","dateModified":"2024-02-27T11:12:58+00:00","description":"L'émulsification par étapes est une variante de la génération de gouttelettes. Cette technique permet un débit élevé de petites gouttelettes. Découvrez comment !","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","width":660,"height":351,"caption":"Schematic illustration of a step emulsification channel"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Step emulsification for high-throughput droplet generation: a review"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Notre blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14296"}],"version-history":[{"count":11,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14296/revisions"}],"predecessor-version":[{"id":18460,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14296/revisions/18460"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14298"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14296"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14296"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14296"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}