{"id":14324,"date":"2023-02-22T12:07:49","date_gmt":"2023-02-22T11:07:49","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14324"},"modified":"2024-02-27T12:11:34","modified_gmt":"2024-02-27T11:11:34","slug":"droplet-generation-in-microfluidics-the-most-used-designs","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/","title":{"rendered":"droplet generation in microfluidics: The most used designs"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14324\" class=\"elementor elementor-14324\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-dee3d57 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"dee3d57\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7f7271c\" data-id=\"7f7271c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-060f89b elementor-widget elementor-widget-text-editor\" data-id=\"060f89b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Les plateformes basées sur la microfabrication et la microfluidique ont été utilisées avec succès dans diverses applications telles que la découverte de médicaments, la réaction en chaîne par polymérase (PCR), l'analyse single-cell ou la cristallisation de protéines, pour n'en citer que quelques-unes. Pour toutes ces applications, la production de microgouttes à des tailles contrôlées ainsi qu'à des taux de génération contrôlés apparaît comme un facteur clé afin d'obtenir des résultats interprétables, fiables et robustes. En effet, la taille des microgouttes peut être affectée par de nombreux facteurs tels que la tension interfaciale ou la taille du canal.</p><p>Aujourd'hui, une large gamme de géométries a été développée, permettant la génération de gouttelettes en mode passif ou actif. Dans cette revue, nous nous concentrerons sur les conceptions de génération de gouttelettes les plus couramment utilisées.</p><h2>Modes passif et actif</h2><h3>Mode passif</h3><p>Les méthodes microfluidiques de formation de microgouttes peuvent être passives ou actives. Dans les méthodes passives, l'écoulement diphasique microfluidique est contrôlé par des pousse-seringues (qui fournissent des débits constants) ou des régulateurs de pression sans apport d'énergie supplémentaire. Pendant la formation des microgouttes, une partie de l'énergie introduite par les pousse-seringues ou les contrôleurs de pression est convertie en énergie interfaciale et facilite ainsi la déstabilisation de l'interface liquide-liquide, par laquelle se produit le détachement de microgouttes discrètes de la phase dispersée [Seemann R. et al. 2012 Rep Prog Phys.]. En pratique, la phase fluide à disperser est poussée dans un <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microcanal</a> par un écoulement commandé en pression dans lequel le débit volumique ou la pression appliquée est nécessairement contrôlé. Un second liquide non miscibles est poussé dans un <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microcanal</a> séparé via un écoulement contrôlé indépendamment. Les deux flux se rencontrent au niveau de la jonction. La géométrie de la jonction et les débits volumiques des deux fluides déterminent le champ d'écoulement, qui déforme l'interface <strong>[Christopher GF and Anna SL. 2007 J Phys Appl Phys]</strong>.</p><h3>Mode actif</h3><p>En mode actif, il est possible de moduler la génération de microgouttes avec un apport d'énergie supplémentaire grâce à des commandes actives comprenant des forces externes telles que des champs électriques, magnétiques ou centrifuges et des forces internes telles que des forces visqueuses et capillaires. Pour être plus précis, le déséquilibre énergétique module la nature de l'équilibre des forces sur l'interface pour la génération de microgouttes.</p><p>La génération active de microgouttes peut être induite par deux types de forces : la modification des forces intrinsèques ou l'introduction de forces supplémentaires. Les forces supplémentaires sont exploitées en appliquant des champs électriques, magnétiques et centrifuges externes, tandis que la modification des forces inertielles, visqueuses et capillaires intrinsèques peut être réalisée en manipulant la vitesse dynamique et les propriétés des matériaux, notamment la viscosité, la tension interfaciale, la mouillabilité du canal et la densité du fluide <strong>[Chong ZZ et al. 2016 Lab Chip.]</strong>.</p><h2>Conceptions de puces pour la génération de microgouttes</h2><h3>Flux transversal avec jonction en T</h3><p>On parle de cross-flow lorsque les fluides en phase dispersée et continue se rencontrent selon un angle θ compris entre 0 et 180° (voir Fig. 1). Généralement, la structure de cross-flow est associée à une <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">jonction en T</a>. Ainsi, les fluides dispersés et continus sont alimentés orthogonalement.</p><p>Il existe trois régimes de génération de microgouttes microfluidiques avec une <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-junction</a> : le régime d'égouttement (dripping), le régime d'étranglement (squeezing) et le régime de jet (jetting) (voir Fig. 2). En principe, les microgouttes générées en mode d'égouttement sont plus petites que la dimension du canal et hautement monodisperse. Pour le régime d'étranglement, les microgouttes sont plus grandes que le canal et monodisperse. Enfin, avec le mode de jet, la génération de microgouttes est polydisperse.</p><p>Le premier avantage du flux croisé (cross-flow) est la facilité avec laquelle les microgouttes peuvent être formées et l'uniformité des microgouttes obtenues. En effet, dans une large plage de débits, il est possible d'obtenir une formation de microgouttes régulière et périodique lorsqu'un canal unique en forme de T est utilisé. Cependant, dans certaines études <strong>[Garstecki P et al. 2005 Nature Phys ; Barbier et al. 2006 Phys Rev.]</strong>, il apparaît que les microgouttes ne sont pas nécessairement régulières lorsque plusieurs générateurs de microgouttes sont couplés à un seul ensemble de pousse-seringues, ce qui peut poser un problème critique dans le cas d'une étude où il est nécessaire de contrôler précisément la taille des microgouttes.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a576702 elementor-widget elementor-widget-image\" data-id=\"a576702\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"107\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-flow-chip-designs-1-1024x171.webp\" class=\"attachment-large size-large wp-image-14326\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-flow-chip-designs-1-1024x171.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-flow-chip-designs-1-300x50.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-flow-chip-designs-1-768x128.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-flow-chip-designs-1.webp 1481w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1 : Schematic of various microfluidic device geometries (not to scale). (a) Cross-flow. (i) &ldquo;T-junction&rdquo; where the continuous and dispersed phase fluids meet perpendicularly (&theta; = 90&deg;). (ii) &ldquo;T-junction&rdquo; in which the two fluids intersect at an angle &theta; (0&deg; &lt; &theta; &lt; 90&deg;). (iii) &ldquo;Head-on&rdquo; geometry (&theta; = 180&deg;). (iv) Y-shaped junction with intersection angle of &theta; (0&deg; &lt; &theta; &lt; 180&deg;). [Zhu et Wang, Lab on Chip, 2017]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50510a1 elementor-widget elementor-widget-image\" data-id=\"50510a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"106\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-modes-cross-flow-1-1024x169.webp\" class=\"attachment-large size-large wp-image-14330\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-modes-cross-flow-1-1024x169.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-modes-cross-flow-1-300x50.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-modes-cross-flow-1-768x127.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-modes-cross-flow-1.webp 1070w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 2 : Images de la génération de microgouttes avec différents modes en flux croisé. (a) Mode d'étranglement. (b) Mode d'égouttement. (c) Mode de jet. [Zhu et Wang, Lab on Chip, 2017]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a4b9153 elementor-widget elementor-widget-global elementor-global-18298 elementor-widget-pix-promo-box\" data-id=\"a4b9153\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Droplet-generators_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"VOUS SOUHAITEZ SIMPLIFIER LA GÉNÉRATION DE GOUTTELETTES EN MICROFLUIDIQUE ?\"><a href=\"https://darwin-microfluidics.com/fr/collections/controleur-de-pression/produits/ob1-droplet-pack-microfluidique\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Découvrez notre sélection !</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">VOUS SOUHAITEZ SIMPLIFIER LA GÉNÉRATION DE GOUTTELETTES EN MICROFLUIDIQUE ?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Libérez le potentiel de nos systèmes user-friendly pour une génération de gouttelettes sans effort</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ec2db6 elementor-widget elementor-widget-text-editor\" data-id=\"6ec2db6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Focalisation de flux</h3><p>La focalisation de flux (flow focusing) correspond à la formation de microgouttes dispersées d'un fluide dans un flux continu d'un autre fluide. Il existe deux variantes de systèmes de focalisation de flux microfluidiques géométriques : la simple jonction en croix et la jonction en croix suivie d'un rétrécissement (également appelé buse). En outre, il est possible de distinguer une configuration planaire quasi-2D (voir Fig. 3 (i) (ii)) et une configuration 3D axisymétrique (voir Fig. 3 (iii) (iv)).</p><p>Par rapport aux dispositifs de focalisation de flux planaires, les dispositifs de focalisation de flux axisymétriques 3D évitent des problèmes tels que le mouillage des parois du canal par la phase dispersée, produisant ainsi des microgouttes monodisperse à des débits plus élevés.</p><p>Ensuite, en ce qui concerne la géométrie à écoulement transversal, on peut distinguer trois modes différents : les modes de compression, de gouttage et de projection (voir fig. 4). L’avantage de la focalisation du flux réside dans sa simplicité géométrique, d’où ses nombreuses variantes de conception. Cependant, il n’existe pas de modèle mécanistique simple permettant de prédire la taille des gouttelettes sur une large gamme de conditions d’écoulement. Un autre problème bien connu est la fusion indésirable des gouttelettes, qui peut être évitée par l’utilisation d’agents tensioactifs. Cependant, ces derniers peuvent également interférer avec les réactions biochimiques ou les inhiber.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2c254e elementor-widget elementor-widget-image\" data-id=\"f2c254e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"127\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1-1024x203.webp\" class=\"attachment-large size-large wp-image-14332\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1-1024x203.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1-300x59.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1-768x152.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1-1536x304.webp 1536w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1.webp 1601w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 4 : Focalisation de flux. (i) Géométrie de focalisation de flux axisymétrique. (ii) Géométrie de focalisation de flux planaire. (iii) Dispositif de focalisation de flux microcapillaire. (iv) Dispositif microcapillaire combinant des géométries de co-flux et de focalisation de flux. [Zhu et Wang, Lab on Chip, 2017]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77b2fd0 elementor-widget elementor-widget-image\" data-id=\"77b2fd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"76\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1-1024x122.webp\" class=\"attachment-large size-large wp-image-14336\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1-1024x122.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1-300x36.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1-768x91.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1-1536x182.webp 1536w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1.webp 1600w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 5 : Images de la génération de microgouttes avec différents modes en focalisation de flux. (a) Mode d'étranglement. (b) Mode d'égouttement. (c) Mode de jet. [Zhu et Wang, Lab on Chip, 2017]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf402bf elementor-widget elementor-widget-text-editor\" data-id=\"cf402bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Interface dynamique multi-canaux</h3><p>Les géométries les plus couramment utilisées dans le domaine des gouttelettes microfluidiques sont la focalisation du flux et les jonctions en T. Il convient de noter que ces techniques exigent des compétences techniques avancées et un équipement spécialisé, ce qui peut constituer un obstacle pour les laboratoires non spécialisés en microfluidique. Par ailleurs, la taille des gouttelettes peut être influencée par de nombreux facteurs tels que l’ fluide , la viscosité, la tension interfaciale, la taille de l’ canal , etc.</p><p>Ici, une technique active (électrique) simple pour générer des microgouttes en utilisant le cisaillement interfacial dynamique piloté par un dispositif mécanique (voir Fig. 1) est utilisée. En pratique, les composants liquides convergent sur la buse et génèrent des microgouttes grâce au cisaillement interfacial dû à la vibration d'un capillaire multi-canaux.</p><p>&nbsp;</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ab6cd3b elementor-widget elementor-widget-image\" data-id=\"ab6cd3b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"480\" height=\"309\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/multichannel_dynamic_interface_480x480-1.webp\" class=\"attachment-large size-large wp-image-14340\" alt=\"Schéma de l'interface dynamique multi-canaux\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/multichannel_dynamic_interface_480x480-1.webp 480w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/multichannel_dynamic_interface_480x480-1-300x193.webp 300w\" sizes=\"(max-width: 480px) 100vw, 480px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1 : Schéma de l'interface dynamique multi-canaux. Un capillaire conique à 3 canaux connectés à trois seringues chargeant différents composants est autorisé à vibrer à la surface de l'huile. En raison du processus de cisaillement interfacial, les microgouttes mélangées à trois composants distincts sont « imprimées » dans une plaque de 96 puits. Les composants des microgouttes peuvent être précisément contrôlés en ajustant le débit des canaux discrets. [Liao et al, American Chemical Society, 2017]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c77f014 elementor-widget elementor-widget-global elementor-global-18301 elementor-widget-pix-promo-box\" data-id=\"c77f014\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Droplet-generators_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"VOUS SOUHAITEZ AUGMENTER VOTRE PRODUCTION DE GOUTTELETTES ?\"><div class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Découvrez notre sélection !</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">VOUS SOUHAITEZ AUGMENTER VOTRE PRODUCTION DE GOUTTELETTES ?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explorez nos solutions évolutives conçues pour répondre facilement aux exigences de la génération de gouttelettes à haut débit.</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></div></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b70bdb elementor-widget elementor-widget-text-editor\" data-id=\"6b70bdb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>L'un des premiers avantages est que le dispositif repose simplement sur un vibreur bon marché et un capillaire multi-canaux conique fait main, qui est facile à assembler et utilisable par tous sans aucune expertise en matière de génération de microgouttes. L'autre avantage est que la technique présente d'excellentes performances pour générer des microgouttes uniformes avec des tailles et des composants prédéfinis. Bien que la fabrication et l'assemblage soient faciles, le fait que les microcanaux soient fabriqués à la main peut représenter un biais dans la reproductibilité du dispositif mais peut également influer sur la taille des microgouttes générées par deux dispositifs différents utilisant les mêmes réglages. De plus, cette technique est limitée à un petit nombre d'applications biologiques telles que l'étude des bactéries, car le diamètre des microgouttes diminue à mesure que le nombre capillaire augmente, en raison des contraintes visqueuses accrues agissant pour déformer la microgoutte.</p><h3>Conclusion</h3><p>Dans cette revue, nous avons vu une très petite partie des géométries existantes et de leurs variations pour générer des microgouttes microfluidiques. Chacune d'entre elles possède des caractéristiques uniques en termes d'instabilités d'écoulement, de taille de microgoutte ou de comportements de microgouttes. Pour une production efficace de microgouttes avec le résultat souhaité, il est important d'avoir une compréhension approfondie des effets des forces visqueuses, inertielles et capillaires. Ainsi, comme la dépendance précise de la taille des microgouttes vis-à-vis des paramètres d'écoulement dépend de la géométrie spécifique considérée, il est important de prendre en compte les besoins et les contraintes précis de l'application de recherche souhaitée pour choisir la conception parfaite de génération de microgouttes.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Les plates-formes basées sur la microfabrication et la microfluidique ont été utilisées avec succès dans diverses applications telles que la découverte de médicaments, la réaction en chaîne par polymérase (PCR), l'analyse single-cell ou la cristallisation des protéines, pour n'en citer que quelques-unes. Pour l'ensemble de ces applications, la production de gouttes à…</p>\n","protected":false},"author":3,"featured_media":14217,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[23,21],"tags":[],"class_list":["post-14324","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-droplet-generation","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Génération de gouttelettes en microfluidique : les configurations les plus couramment utilisées</title>\n<meta name=\"description\" content=\"Aujourd'hui, une large gamme de géométries a été développée, permettant la génération de gouttelettes. Nous nous concentrerons sur la conception la plus couramment utilisée.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Génération de gouttelettes en microfluidique : les configurations les plus couramment utilisées\">\n<meta property=\"og:description\" content=\"Aujourd'hui, une large gamme de géométries a été développée, permettant la génération de gouttelettes. Nous nous concentrerons sur la conception la plus couramment utilisée.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-22T11:07:49+00:00\">\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:11:34+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp\">\n\t<meta property=\"og:image:width\" content=\"1000\">\n\t<meta property=\"og:image:height\" content=\"1000\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"8 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"droplet generation in microfluidics: The most used designs\",\"datePublished\":\"2023-02-22T11:07:49+00:00\",\"dateModified\":\"2024-02-27T11:11:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\"},\"wordCount\":1399,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp\",\"articleSection\":[\"Droplet generation\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\",\"url\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\",\"name\":\"droplet generation in microfluidics: The most used designs\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp\",\"datePublished\":\"2023-02-22T11:07:49+00:00\",\"dateModified\":\"2024-02-27T11:11:34+00:00\",\"description\":\"Aujourd'hui, une large gamme de géométries a été développée, permettant la génération de gouttelettes. Nous nous concentrerons sur la conception la plus couramment utilisée.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp\",\"width\":1000,\"height\":1000,\"caption\":\"Photograph of a droplet generator from Droplet Genomics\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"droplet generation in microfluidics: The most used designs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Notre blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/fr\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"droplet generation in microfluidics: The most used designs","description":"Aujourd'hui, une large gamme de géométries a été développée, permettant la génération de gouttelettes. Nous nous concentrerons sur la conception la plus couramment utilisée.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/","og_locale":"en_US","og_type":"article","og_title":"droplet generation in microfluidics: The most used designs","og_description":"Today, a wide range of geometries have been developed, allowing the generation of droplets. We will focus on the most widely used design.","og_url":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T11:07:49+00:00","article_modified_time":"2024-02-27T11:11:34+00:00","og_image":[{"width":1000,"height":1000,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"8 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"droplet generation in microfluidics: The most used designs","datePublished":"2023-02-22T11:07:49+00:00","dateModified":"2024-02-27T11:11:34+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/"},"wordCount":1399,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","articleSection":["Droplet generation","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/","url":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/","name":"droplet generation in microfluidics: The most used designs","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","datePublished":"2023-02-22T11:07:49+00:00","dateModified":"2024-02-27T11:11:34+00:00","description":"Aujourd'hui, une large gamme de géométries a été développée, permettant la génération de gouttelettes. Nous nous concentrerons sur la conception la plus couramment utilisée.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","width":1000,"height":1000,"caption":"Photograph of a droplet generator from Droplet Genomics"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"droplet generation in microfluidics: The most used designs"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Notre blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14324"}],"version-history":[{"count":20,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14324/revisions"}],"predecessor-version":[{"id":18450,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14324/revisions/18450"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14217"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14324"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14324"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}