{"id":14504,"date":"2023-02-22T18:07:28","date_gmt":"2023-02-22T17:07:28","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14504"},"modified":"2024-07-16T12:08:01","modified_gmt":"2024-07-16T10:08:01","slug":"organ-on-chip-for-blood-brain-barrier-research","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/","title":{"rendered":"Organ-on-chip for blood-brain barrier research"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14504\" class=\"elementor elementor-14504\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-33f9a85 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"33f9a85\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-317c52a\" data-id=\"317c52a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-dd6f8cc elementor-widget elementor-widget-text-editor\" data-id=\"dd6f8cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>En combinant les principes de la microfluidique, de la microfabrication et des techniques de culture cellulaire, une nouvelle génération de plateformes de laboratoire a émergé, connue sous le nom d'« organe-sur-puce ». Les systèmes organe-sur-puce sont des dispositifs microfluidiques contenant des cellules vivantes. Ces dispositifs microfluidiques peuvent mieux récapituler les microenvironnements par rapport aux modèles in vitro précédents. Les dispositifs microfluidiques sont particulièrement adaptés à la modélisation des barrières biologiques, telles que la barrière hémato-encéphalique, car ils peuvent modéliser le flux sanguin.</p><h2>Structure et fonction de la barrière hémato-encéphalique</h2><p>La barrière hémato-encéphalique (BHE) est la couche limite de cellules qui tapisse les microvaisseaux cérébraux et sépare le sang des fluides interstitiels cérébraux. La fonction principale de la barrière hémato-encéphalique est d'agir comme une barrière physique et métabolique en permettant le transport sélectif des nutriments, mais en empêchant les substances toxiques présentes dans le sang de pénétrer dans le cerveau.</p><p>La BHE est composée de cellules endothéliales spécialisées qui sont entourées d'une membrane basale et de quatre autres types de cellules : les astrocytes, les péricytes, les neurones et la microglie. Ces cinq types de cellules et la membrane basale constituent ensemble l'unité neurovasculaire (figure 1) [1]. Des complexes protéiques d'étanchéité appelés jonctions serrées se forment entre les cellules endothéliales adjacentes de la BHE. En conséquence, les cellules sont maintenues en étroite proximité les unes des autres, occluant ainsi les espaces intracellulaires et empêchant le transport paracellulaire. Cette forte étanchéité de la barrière est caractéristique de la BHE et cruciale pour le maintien de l'homéostasie cérébrale. Une perturbation locale de l'étanchéité de la barrière, entraînant une fuite à travers celle-ci, est associée à plusieurs maladies du système nerveux central (SNC) [2]. Comprendre et surmonter la BHE est essentiel pour le traitement des maladies du SNC. Les systèmes d'administration de médicaments qui peuvent temporairement ouvrir la barrière, permettant aux médicaments de passer et d'atteindre le cerveau, constituent un domaine de recherche clé pour le traitement des maladies du SNC.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd8c56f elementor-widget elementor-widget-image\" data-id=\"dd8c56f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"321\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1-768x385.webp\" class=\"attachment-medium_large size-medium_large wp-image-14506\" alt=\"Illustration de l'unité neurovasculaire\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1-768x385.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1-300x150.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp 940w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1. Illustration de l'unité neurovasculaire [1]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea79704 elementor-widget elementor-widget-text-editor\" data-id=\"ea79704\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Modèles in vitro de la barrière hémato-encéphalique</h2><p>Dans des environnements artificiels, les conditions peuvent être maintenues sous un contrôle strict et des comportements spécifiques peuvent être étudiés indépendamment avec peu d'interférence d'autres facteurs. Traditionnellement, la BHE a été reconstruite in vitro sous forme de modèles statiques utilisant des configurations de culture cellulaire conventionnelles. Les dispositifs microfluidiques organe-sur-puce offrent des solutions à de nombreuses lacunes des modèles in vitro précédents. Ces dispositifs peuvent être conçus avec des architectures plus réalistes et leurs petites dimensions représentent mieux la géométrie des capillaires dans l'unité neurovasculaire. De plus, en employant la microfluidique au lieu de mener des expériences dans une solution en vrac, les modèles peuvent présenter des phénomènes physiologiques tels que les flux de fluides et les contraintes de cisaillement. Un autre avantage des modèles BHE-sur-puce est que des capteurs pour la surveillance en temps réel peuvent être intégrés [3].</p><h2>Barrière hémato-encéphalique sur une puce microfluidique</h2><p>Deux des premiers dispositifs microfluidiques qui ont ouvert la voie au développement de la « barrière hémato-encéphalique surpuce » et ont permis de valider le principe de plusieurs concepts prometteurs sont présentés ci-dessous. Certains aspects importants de la conception et paramètres de validation à prendre en compte lors du développement d’un dispositif « organe surpuce » destiné à l’étude de la barrière hémato-encéphalique seront également abordés. Aujourd’hui, des puces prêtes à l’emploi pour les applications « organe surpuce » sont disponibles dans le commerce ou peuvent être commandées sur mesure.</p><p>À notre connaissance, Booth et al. ont été les premiers à publier, en 2012 [4], un modèle inpuce de la barrière hémato-encéphalique (BHE), suivi d’un article complémentaire en 2014 [5]. Leur dispositif, illustré à la figure 2, comprend deux canaux qui se croisent dans des couches d’ PDMS, d’une profondeur de 200 µm et d’une largeur de 2 mm et 5 mm respectivement. Les deux canaux étaient séparés par une membrane poreuse en polycarbonate recouverte de fibronectine. Les couches d’ canal étaient recouvertes de lames de verre sur lesquelles étaient placées des électrodes à couche mince Ag/AgCl dotées d’une structure de détection à quatre points, disposées au-dessus de la membrane. Des cellules endothéliales de souris (b.End3) et des astrocytes murins (C8D1A) ont été mis en coculture de part et d’autre de la membrane. Un débit d’ débit e de 2,6 mL/min a été appliqué dans les deux canaux, ce qui, selon les calculs présentés dans l’article, correspondait à une contrainte de cisaillement de 2 mPa sur les cellules endothéliales. La résistance électrique transendothéliale (TEER) a été mesurée entre 180 et 280 Vcm² à l’aide des électrodes à couche mince intégrées. De plus, la protéine de jonction serrée ZO-1 a été identifiée par immunofluorescence, et des études de perméabilité ont été réalisées pour confirmer la fonction de barrière.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c118f93 elementor-widget elementor-widget-image\" data-id=\"c118f93\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"574\" height=\"295\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-2-1.webp\" class=\"attachment-medium_large size-medium_large wp-image-14508\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-2-1.webp 574w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-2-1-300x154.webp 300w\" sizes=\"(max-width: 574px) 100vw, 574px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 2. Illustration schématique et image du dispositif BHE-sur-puce développé par Booth et al. (Reproduit de Booth et al. [5])</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c3267e elementor-widget elementor-widget-text-editor\" data-id=\"4c3267e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un autre dispositif BHE entièrement intégré a été publié par Griep et al. en 2013 [6]. Le dispositif était composé de deux couches de PDMS comprenant des canaux d'une largeur de 500 µm et d'une profondeur de 100 µm, avec une membrane de polycarbonate recouverte de collagène intercalée. Des cellules endothéliales microvasculaires cérébrales humaines (hCMEC/D3) ont été cultivées sur la membrane. Ils ont utilisé quatre fils de platine pour surveiller la valeur de TEER sur 7 jours à partir de mesures par spectroscopie d'impédance. Ils ont obtenu une valeur moyenne de TEER de 28 Vcm2 ± 1,3 SEM. Ils ont observé une augmentation de la TEER, jusqu'à 120 Vcm2, lorsqu'un débit de 2,5 mL/h était appliqué, correspondant à une contrainte de cisaillement calculée de 0,58 Pa.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-250128e elementor-widget elementor-widget-image\" data-id=\"250128e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"230\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-3-1.webp\" class=\"attachment-large size-large wp-image-14510\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-3-1.webp 940w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-3-1-300x108.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-3-1-768x276.webp 768w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 3. Illustration schématique des couches de la puce (a) et de la puce assemblée (b), et image du dispositif BHE-sur-puce développé par Griep et al. (Reproduit de Griep et al. [6])</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-991830b elementor-widget elementor-widget-global elementor-global-18295 elementor-widget-pix-promo-box\" data-id=\"991830b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/17424049-optimized-DDI-Chip_blue2_2048x2048.webp\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"ORGANE SUR PUCE : L'AVENIR DE LA RECHERCHE ?\"><a href=\"https://darwin-microfluidics.com/fr/collections/organe-sur-puce-microfluidique\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Découvrez notre sélection !</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">ORGANE SUR PUCE : L'AVENIR DE LA RECHERCHE ?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explorez nos solutions de pointe pour la recherche et le développement avancés !</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b9a967 elementor-widget elementor-widget-text-editor\" data-id=\"7b9a967\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Matériau de la puce pour organe-sur-puce</h2>\n<p>Le PDMS a été largement utilisé pour fabriquer des dispositifs organe-sur-puce. Parmi les avantages du PDMS, on compte sa biocompatibilité, sa transparence (240 nm – 1100 nm), son faible coût et sa facilité de cadre, sa capacité à être moulé avec une haute résolution, et sa faculté à se lier au verre ou au PDMS [7]. Il est cependant fortement <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/hydrophobic-microfluidic-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">hydrophobe</a>, ce qui peut être problématique lors du remplissage des canaux ou pour obtenir une liaison étanche pour des puces sans fuite. De plus, il est difficile de déposer des électrodes sur la surface du PDMS, et le verre est donc souvent utilisé dans les dispositifs dotés d'électrodes en couches minces structurées.</p>\n<h3>Cellules dans les modèles de barrière hémato-encéphalique sur puce</h3>\n<p>Le type de cellules utilisées revêt une grande importance pour la construction de modèles biologiquement pertinents. On ignore toutefois encore précisément comment les différentes cellules de l’unité neurovasculaire contribuent à la fonction de barrière [8]. Pour reproduire la BHE humaine, l’utilisation de cellules humaines serait évidemment la plus prédictive. Les cellules endothéliales de l’ capillaire e cérébrale humaine ont été largement caractérisées, mais leur disponibilité et leur reproductibilité sont faibles [1]. Les progrès récents dans la production de cellules souches pluripotentes induites humaines (hiPSC) sont très prometteurs pour surmonter ces difficultés [9].</p>\n<p>La co-culture de cellules endothéliales avec d'autres cellules de l'unité neurovasculaire est considérée comme une représentation plus pertinente sur le plan physiologique, car ces cellules influencent également la formation et le maintien de la barrière [10]. Plusieurs études de co-cultures dans des modèles microfluidiques de BBB ont déjà été publiées, principalement des cellules endothéliales avec des astrocytes [4] [11], mais aussi avec des neurones [12] et des péricytes. Les astrocytes et les cellules endothéliales ne sont pas en contact direct l'un avec l'autre mais sont séparés par la lame basale. Dans les dispositifs microfluidiques, elles peuvent être cultivées sur des côtés séparés de la membrane. Cependant, si la membrane du dispositif est trop épaisse, le contact cellule-cellule sera limité. Pour imiter l'environnement 3D de la matrice extracellulaire, des hydrogels ont été utilisés comme échafaudages d'ensemencement cellulaire à l'intérieur des chambres microfluidiques [12].</p>\n<h3>Contrainte de cisaillement sur les cellules endothéliales</h3>\n<p>Les cellules endothéliales de la BHE au sein de l'unité neurovasculaire sont soumises à une force normale à la paroi du vaisseau due à la pression sanguine, ainsi qu'à un <a href=\"https://darwin-microfluidics.com/fr/blogs/avis/contrainte-de-cisaillement-dans-les-dispositifs-microfluidiques\">cisaillement</a> résultant du flux sanguin, dans la direction du flux. Il a déjà été rapporté que les contraintes de cisaillement influencent la morphologie et la fonction des cellules endothéliales, et qu'elles ont un effet positif sur la formation de la barrière [13]. Les dispositifs organe-sur-puce ont le grand avantage d'être adaptés à l'incorporation d'un flux de fluide, contrairement à d'autres types de dispositifs. Les vaisseaux sanguins vivants ont des sections transversales circulaires, tandis que les dispositifs microfluidiques ont généralement des sections transversales rectangulaires. Dans un tube de section transversale circulaire, la contrainte de cisaillement sera égale et uniforme sur les parois en raison de la symétrie cylindrique. Dans le cas d'une section transversale rectangulaire, cependant, la contrainte de cisaillement ne sera pas uniforme. Pour obtenir la contrainte la plus uniforme dans une section transversale rectangulaire, un profil de flux aussi plat que possible peut être réalisé en concevant les canaux de manière à ce que la hauteur du canal soit beaucoup plus petite que la largeur du canal [14]. La contrainte de cisaillement physiologique pour les capillaires cérébraux est de 0,3-2 Pa [2].</p>\n<p></p>\n<h3>Résistance électrique transendothéliale (TEER)</h3>\n<p></p>\n<p>La TEER décrit la résistance à travers une barrière cellulaire et est souvent utilisée comme paramètre de validation pour vérifier si les cellules endothéliales dans les modèles de BHE forment des complexes de jonctions serrées [15]. Si les cellules endothéliales se développent correctement et forment des jonctions serrées avec les cellules adjacentes, les espaces intercellulaires de la couche cellulaire sont occlus et le flux de courant est restreint [16]. Ceci induit une résistance plus élevée au courant, ce qui se reflète dans des valeurs de TEER plus élevées. La TEER est souvent exprimée normalisée à la surface de la membrane dans l'unité Ωcm<sup>2</sup>, comme indiqué ci-dessous, pour faciliter la comparaison directe avec d'autres modèles.</p>\n<p>𝑇𝐸𝐸𝑅 (Ω 𝑐𝑚<sup>2</sup>) = 𝑅𝑒𝑠𝑖𝑠𝑡𝑎𝑛𝑐𝑒 (Ω) × 𝐶𝑒𝑙𝑙 𝑐𝑢𝑙𝑡𝑢𝑟𝑒 𝑎𝑟𝑒𝑎 (𝑐𝑚<sup>2</sup>)</p>\n<p>Dans les modèles de BHE sur puce, la mesure de la TEER est une méthode rapide et non invasive permettant une évaluation en temps réel de la qualité de la barrière. Les mesures sont effectuées en appliquant un faible courant électrique à travers la couche cellulaire tout en mesurant l'impédance du courant par la couche cellulaire. Les dispositifs organe-sur-puce sont adaptés à l'intégration de capteurs où la TEER peut être surveillée en temps réel, ce qui est difficile avec d'autres types de dispositifs. Les modèles <em>in vitro</em> de la BHE doivent atteindre des valeurs de TEER supérieures à 150-200 Ωcm<sup>2</sup> pour être considérés comme des modèles acceptables [19]. Ceci est environ dix fois inférieur aux résultats rapportés <em>in vivo </em>. La raison pour laquelle une TEER beaucoup plus faible est acceptée est due aux conditions simplifiées <em>in vitro</em>.</p>\n<h3>Perméabilité des modèles de barrière hémato-encéphalique sur puce</h3>\n<p>Les modèles organe-sur-puce peuvent fournir directement des informations sur la fonction de barrière en testant la perméabilité de la barrière à différentes substances. Il est utile de quantifier la perméabilité de manière à ce qu'elle puisse être facilement comparée aux données <em>in vivo</em>. Le transport passif à travers la barrière peut être quantifié à partir du coefficient de perméabilité d'un analyte s'écoulant à travers la puce. Il convient de noter que des facteurs autres que la diffusion peuvent contribuer au transport, tels que le flux convectif s'il y a des lacunes dans la barrière cellulaire, et le flux osmotique dû aux différences de concentrations de solutés entre les canaux. Ceci peut être évité en contrôlant la concentration du soluté dans les canaux et en ayant la même pression dans les deux canaux pendant les expériences. Le transport des composés hydrophiles à travers la barrière étant très restreint, ces composés marqués par des traceurs fluorescents sont souvent utilisés pour les études de perméabilité. La perméabilité peut ensuite être visualisée à l'aide d'un microscope à fluorescence.</p>\n<p><strong>Rédigé par Emma Thomée, doctorante pour le projet MAMI, avec le financement du programme de recherche et d'innovation Horizon 2020 de l'Union européenne, au titre de la convention de subvention n° 766007.</strong></p>\n<h3>Bibliographie</h3>\n<p></p>\n<ol>\n<li>Abbott, N.J., et al., <em>Structure and function of the blood-brain barrier.</em> Neurobiol Dis, 2010. <strong>37</strong>(1): p. 13-25.</li>\n<li>Wong, A.D., et al., <em>La barrière hémato-encéphalique : une perspective d'ingénierie.</em> Front Neuroeng, 2013. <strong>6</strong>: p. 7.</li>\n<li>Bhatia, S.N. et D.E. Ingber, <em>Organes sur puce microfluidiques.</em> Nat Biotechnol, 2014. <strong>32</strong>(8): p. 760-72.</li>\n<li>Booth, R. et H. Kim, <em>Characterization of a microfluidic in vitro model of the blood-brain barrier ([small mu ]BBB).</em> Lab on a Chip, 2012. <strong>12</strong>(10): p. 1784-1792.</li>\n<li>Booth, R. et H. Kim, <em>Analyse de la perméabilité des médicaments neuroactifs à travers un modèle dynamique de barrière hémato-encéphalique in vitro microfluidique.</em> Ann Biomed Eng, 2014. <strong>42</strong>(12): p. 2379-91.</li>\n<li>Griep, L.M., et al., <em>BBB on chip: microfluidic platform to mechanically and biochemically modulate blood-brain barrier function.</em> Biomed Microdevices, 2013. <strong>15</strong>(1): p. 145-50.</li>\n<li>Sia, S.K. et G.M. Whitesides, <em>Dispositifs microfluidiques fabriqués en poly(diméthylsiloxane) pour les études biologiques.</em> Electrophoresis, 2003. <strong>24</strong>(21): p. 3563-76.</li>\n<li>Hawkins, B.T. et T.P. Davis, <em>The Blood-Brain Barrier/Neurovascular Unit in Health and Disease.</em> Pharmacological Reviews, 2005. <strong>57</strong>(2): p. 173.</li>\n<li>Pamies, D., T. Hartung, et H.T. Hogberg, <em>Biological and medical applications of a brain-on-a-chip.</em> Experimental Biology and Medicine, 2014. <strong>239</strong>(9): p. 1096-1107.</li>\n<li>Serlin, Y., et al., <em>Anatomie et physiologie de la barrière hémato-encéphalique.</em> Seminars in cell & developmental biology, 2015. <strong>38</strong>: p. 2-6.</li>\n<li>Bang, S., et al., <em>Une plateforme microfluidique de barrière hémato-encéphalique à faible perméabilité avec contact direct entre le réseau vasculaire perfusable et les astrocytes.</em> Scientific Reports, 2017. <strong>7</strong>(1): p. 8083.</li>\n<li>Adriani, G., et al., <em>A 3D neurovascular microfluidic model consisting of neurons, astrocytes and cerebral endothelial cells as a blood-brain barrier.</em> Lab On A Chip, 2017. <strong>17</strong>(3): p. 448-459.</li>\n<li>Dewey, C.F., et al., <em>The dynamic response of vascular endothelial cells to fluid shear stress.</em> J Biomech Eng, 1981. <strong>103</strong>(3): p. 177-85.</li>\n<li>van der Helm, M.W., et al.,<em>Technologie microfluidique « organ-on-puce » pour la recherche sur la barrière hémato-encéphalique.</em>Tissue Barriers, 2016.<strong>4</strong>(1) : p. e1142493.</li>\n<li>Srinivasan, B., et al., <em>TEER measurement techniques for in vitro barrier model systems.</em> J Lab Autom, 2015. <strong>20</strong>(2): p. 107-26.</li>\n<li>Thuenauer, R., E. Rodriguez-Boulan, et W. Römer, <em>Approches microfluidiques pour la culture et la caractérisation de couches de cellules épithéliales.</em> Analyst, 2014. <strong>139</strong>(13): p. 3206-18.</li>\n<li>Benson, K., S. Cramer, et H.J. Galla, <em>Surveillance cellulaire basée sur l'impédance : propriétés de barrière et au-delà.</em> Fluids Barriers CNS, 2013. <strong>10</strong>(1): p. 5.</li>\n<li>Wegener, J. et J. Seebach, <em>Outils expérimentaux pour surveiller la dynamique de la fonction de barrière endothéliale : une revue des approches in vitro.</em> Cell Tissue Res, 2014. <strong>355</strong>(3): p. 485-514.</li>\n<li>Reichel, A., D.J. Begley, and N.J. Abbott, <em>An overview of in vitro techniques for blood-brain barrier studies.</em> Methods Mol Med, 2003. <strong>89</strong>: p. 307-24.</li>\n</ol>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-523c045 elementor-widget elementor-widget-global elementor-global-18295 elementor-widget-pix-promo-box\" data-id=\"523c045\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/17424049-optimized-DDI-Chip_blue2_2048x2048.webp\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"ORGANE SUR PUCE : L'AVENIR DE LA RECHERCHE ?\"><a href=\"https://darwin-microfluidics.com/fr/collections/organe-sur-puce-microfluidique\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Découvrez notre sélection !</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">ORGANE SUR PUCE : L'AVENIR DE LA RECHERCHE ?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explorez nos solutions de pointe pour la recherche et le développement avancés !</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>By combining the principles of microfluidics, microfabrication, and cell culturing techniques, a new generation of laboratory platforms has emerged, known as “organ-on-chip”. Organ-on-chip systems are microfluidic devices containing living cells. These microfluidic devices can better recapitulate microenvironments compared to previous…</p>\n","protected":false},"author":3,"featured_media":14506,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[27,21],"tags":[],"class_list":["post-14504","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>« Organ-on-puce » pour la recherche sur la barrière hémato-encéphalique</title>\n<meta name=\"description\" content=\"Les systèmes organe-sur-puce sont des dispositifs microfluidiques contenant des cellules vivantes. Découvrez comment ils peuvent répliquer la barrière hémato-encéphalique !\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"« Organ-on-puce » pour la recherche sur la barrière hémato-encéphalique\">\n<meta property=\"og:description\" content=\"Les systèmes organe-sur-puce sont des dispositifs microfluidiques contenant des cellules vivantes. Découvrez comment ils peuvent répliquer la barrière hémato-encéphalique !\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-22T17:07:28+00:00\">\n<meta property=\"article:modified_time\" content=\"2024-07-16T10:08:01+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp\">\n\t<meta property=\"og:image:width\" content=\"940\">\n\t<meta property=\"og:image:height\" content=\"471\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"11 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Organ-on-chip for blood-brain barrier research\",\"datePublished\":\"2023-02-22T17:07:28+00:00\",\"dateModified\":\"2024-07-16T10:08:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\"},\"wordCount\":2184,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\",\"url\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\",\"name\":\"Organ-on-chip for blood-brain barrier research\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp\",\"datePublished\":\"2023-02-22T17:07:28+00:00\",\"dateModified\":\"2024-07-16T10:08:01+00:00\",\"description\":\"Les systèmes organe-sur-puce sont des dispositifs microfluidiques contenant des cellules vivantes. Découvrez comment ils peuvent répliquer la barrière hémato-encéphalique !\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp\",\"width\":940,\"height\":471,\"caption\":\"Illustration of the neurovascular unit\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Organ-on-chip for blood-brain barrier research\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Notre blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/fr\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Organ-on-chip for blood-brain barrier research","description":"Les systèmes organe-sur-puce sont des dispositifs microfluidiques contenant des cellules vivantes. Découvrez comment ils peuvent répliquer la barrière hémato-encéphalique !","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/","og_locale":"en_US","og_type":"article","og_title":"Organ-on-chip for blood-brain barrier research","og_description":"Organ-on-chip systems are microfluidic devices containing living cells. Find out how they can replicate the blood-brain barrier!","og_url":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T17:07:28+00:00","article_modified_time":"2024-07-16T10:08:01+00:00","og_image":[{"width":940,"height":471,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"11 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Organ-on-chip for blood-brain barrier research","datePublished":"2023-02-22T17:07:28+00:00","dateModified":"2024-07-16T10:08:01+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/"},"wordCount":2184,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","articleSection":["Cell culture &amp; organ-on-chip","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/","url":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/","name":"Organ-on-chip for blood-brain barrier research","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","datePublished":"2023-02-22T17:07:28+00:00","dateModified":"2024-07-16T10:08:01+00:00","description":"Les systèmes organe-sur-puce sont des dispositifs microfluidiques contenant des cellules vivantes. Découvrez comment ils peuvent répliquer la barrière hémato-encéphalique !","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","width":940,"height":471,"caption":"Illustration of the neurovascular unit"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Organ-on-chip for blood-brain barrier research"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Notre blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14504","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14504"}],"version-history":[{"count":15,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14504/revisions"}],"predecessor-version":[{"id":25608,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14504/revisions/25608"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14506"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14504"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14504"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14504"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}