{"id":15987,"date":"2024-02-05T15:25:01","date_gmt":"2024-02-05T14:25:01","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=15987"},"modified":"2026-11-19T15:14:07","modified_gmt":"2026-11-19T14:14:07","slug":"choosing-the-right-materials-for-your-organ-on-a-chip-device","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","title":{"rendered":"Choosing the right materials for your organ-on-a-chip device"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"15987\" class=\"elementor elementor-15987\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-55eda1c3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"55eda1c3\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-433001d0\" data-id=\"433001d0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c2f8cea elementor-widget elementor-widget-text-editor\" data-id=\"c2f8cea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p></p>\n<p class=\"wp-block-paragraph\">Au cours des dernières années, des développements majeurs ont eu lieu dans les plateformes d'<strong> <a href=\"https://darwin-microfluidics.com/fr/collections/organe-sur-puce-microfluidique\">organes sur puce (OoC)</a></strong>. Pourtant, il n'existe pas de modèle 'universel', et il n'y en aura probablement jamais, compte tenu de la variété des applications pour lesquelles ces dispositifs peuvent être utilisés. Ainsi, il est judicieux de prendre en compte plusieurs paramètres clés lors du choix ou du développement d'une plateforme d'Organe sur puce afin d'obtenir un système le mieux adapté à la question scientifique à laquelle répondre. </p>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\"> Si vous souhaitez en savoir plus sur les organes sur puce, lisez notre article : <strong><a href=\"https://darwin-microfluidics.com/fr/blogs/avis/organe-sur-puce-presentation-generale\">Organe sur puce : un aperçu général</a></strong>. </p>\n<p></p>\n<p></p>\n<h2 class=\"wp-block-heading\">Conception du dispositif Organe sur puce</h2>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">La conception de la puce est un élément critique à prendre en compte lors du développement d'un modèle OoC. Elle dépend de l'application spécifique pour laquelle le dispositif sera utilisé. Cela déterminera les paramètres géométriques tels que le nombre, la forme et les dimensions des canaux, le nombre d'entrées/sorties, et la présence de chambres de culture, de ports, ou de tout autre élément nécessaire pour mener à bien l'étude prévue. Du côté biologique, le nombre de cellules, la densité et le volume de fluide doivent également être pris en compte lors du processus de conception. Une définition appropriée de ces éléments contribuera à une modélisation physiologique précise de l'organe/des cellules étudiées.</p>\n<p>Une autre question qui se pose lors de la mise en œuvre d'un modèle OoC est la nécessité du multiplexage – c'est-à-dire avoir plusieurs conceptions sur une seule plateforme – ce qui définira souvent le format de la plateforme. Disposer de plusieurs réplicats sur le même dispositif peut représenter un gain de temps considérable et même être nécessaire, en particulier pour les tests de médicaments.</p>\n<p>La conception de la plateforme doit également prendre en compte les paramètres que le chercheur souhaite tester/mesurer avec celle-ci. Certains résultats pertinents pour l'étude peuvent nécessiter un accès à des parties spécifiques de la puce pour effectuer des analyses. Par exemple, pour identifier un biomarqueur spécifique, il peut être utile de pouvoir collecter des effluents plusieurs fois au cours de l'étude et ainsi prévoir un port spécial pour faciliter la collecte des milieux. De plus, si une analyse doit être effectuée sur les cellules/tissus à la fin de l'expérience, il est important de pouvoir récupérer les cellules/tissus de la plateforme.</p>\n<p>Enfin, des paramètres logistiques supplémentaires tels que l'encombrement, l'utilisation en incubateur, la circulation du fluide, entre autres, peuvent influencer la manière dont la plateforme sera utilisée et, par conséquent, sa conception.</p>\n<p></p>\n<p></p>\n<h2 class=\"wp-block-heading\">Comment choisir le bon matériau pour votre dispositif organe sur puce ?</h2>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">Le choix du matériau est d'une grande importance, mais il n'est pas si facile de trouver un matériau qui répondra à toutes les exigences de l'expérience et des compromis pourraient être nécessaires dans cette sélection. Parmi les paramètres de cette sélection figurent la biocompatibilité, bien sûr, mais aussi la stratégie de microfabrication choisie ou disponible, les points finaux que le modèle doit atteindre, la rigidité du substrat, la perméabilité aux gaz, les considérations concernant la production de masse, et bien d'autres.</p>\n<p></p>\n<p></p>\n<h3 class=\"wp-block-heading\">Les principaux matériaux pour les dispositifs organe sur puce</h3>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">Actuellement, il n'existe pas de matériau idéal parfait pour les dispositifs OoC. En général, il est préférable que le matériau choisi ne soit pas toxique pour les cellules, soit perméable aux gaz et permette une observation optique. Plusieurs options de matériaux sont disponibles, chacune présentant des avantages et des inconvénients en termes de paramètres physico-chimiques, biologiques, économiques ou pratiques.</p>\n<p></p>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">&nbsp;</p>\n<p></p>\n<p><!-- /wp:list --></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b11b3b elementor-widget elementor-widget-image\" data-id=\"5b11b3b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"447\" height=\"480\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\" class=\"attachment-large size-large wp-image-18533\" alt=\"tableau des matériaux pour les organes sur puces\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp 447w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480-279x300.webp 279w\" sizes=\"(max-width: 447px) 100vw, 447px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ead827 elementor-widget elementor-widget-text-editor\" data-id=\"7ead827\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"color: #252525; letter-spacing: -0.16px;\"><em>D'après Campbell et al., 2021 – Vert : bon, jaune : moyen, rouge : mauvais</em></p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Le matériau le plus utilisé pour les puces microfluidiques et les OoC est le <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://darwin-microfluidics.com/fr/produits/pdms-sylgard-184-elsatomer\">PDMS</a></span> (Polydiméthylsiloxane), principalement en raison de sa facilité d'utilisation, de son faible coût et de sa transparence optique. Il présente également une perméabilité élevée qui peut être à la fois un avantage et un inconvénient. Bien qu'il permette un apport adéquat en oxygène aux cultures cellulaires, il peut également interférer avec le métabolisme des médicaments ou la production de métabolites par les tissus, avec un risque accru que les petites molécules d'intérêt soient absorbées dans la matrice polymère.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">D'autres matériaux couramment utilisés dans la fabrication de puces sont les <span style=\"font-weight: bolder;\">thermoplastiques.</span> Leur faible coût, leur faible <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">absorption</a> et leurs propriétés de transparence optique constituent des avantages importants pour la production (de masse) d'OoC. Cependant, la rigidité des thermoplastiques peut poser problème pour la modélisation physiologique. Dans le corps, la rigidité des tissus peut descendre jusqu'à quelques kPa pour le tissu adipeux ou le cerveau, comparativement aux quelques GPa des thermoplastiques courants. Il peut également être difficile de créer des géométries complexes avec les thermoplastiques, ce qui peut constituer une limitation pour la conception de la puce.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Un autre matériau utilisé pour les dispositifs OoC est le verre, qui présente l'avantage d'être hautement transparent, inerte, biocompatible et de posséder une faible autofluorescence. La surface du verre peut également être facilement modifiée pour ajuster l'adhésion cellulaire. Cependant, les dispositifs en verre sont beaucoup plus fragiles et coûteux, en plus d'un processus de fabrication plus laborieux.</p>\n<h3 class=\"wp-block-heading\" style=\"font-family: Lato, sans-serif; letter-spacing: -0.16px;\">Stérilisation des matériaux et traitement de surface</h3>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Une fois qu'un matériau a été choisi, des questions concernant sa stérilisation ou sa fonctionnalisation peuvent se poser.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">La stérilisation peut s'avérer nécessaire afin d'éviter toute contamination microbienne du dispositif, laquelle pourrait interférer avec l'étude menée et ses résultats. De nombreuses techniques de stérilisation existent, telles que l'autoclavage, l'exposition aux UV, le traitement à l'éthanol, l'irradiation gamma ou le traitement à l'oxyde d'éthylène. Cependant, toutes ces méthodes ne sont pas compatibles avec l'ensemble des matériaux mentionnés ci-dessus. Par exemple, bien qu'il soit sûr d'autoclaver le polycarbonate (PC), cela pourrait ne pas être le cas pour le PMMA. Il est donc crucial de choisir la technique de stérilisation appropriée pour prévenir tout dommage au matériau sélectionné.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Le traitement de surface peut également être une étape nécessaire dans le développement des dispositifs OoC pour plusieurs raisons : assurer la biocompatibilité, et améliorer ou prévenir l'adhésion cellulaire. Là encore, plusieurs techniques peuvent être disponibles pour remplir ces fonctions, et la compatibilité avec le matériau de la puce ainsi qu'avec les cellules/tissus est requise.</p>\n<h2 class=\"wp-block-heading\" style=\"font-family: Lato, sans-serif; letter-spacing: -0.16px;\">Références :</h2>\n<ol style=\"letter-spacing: -0.16px;\">\n<li>Scott B. Campbell, Qinghua Wu, Joshua Yazbeck, Chuan Liu, Sargol Okhovatian, and Milica Radisic – ACS Biomaterials Science & Engineering <span style=\"font-weight: bolder;\">2021</span> <em>7</em> (7), 2880-2899 – DOI: <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://pubs.acs.org/doi/10.1021/acsbiomaterials.0c00640\">10.1021/acsbiomaterials.0c00640</a></span></li>\n<li>Toepke, Michael W., et David J. Beebe. «<a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">Absorption</a> de petites molécules<a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\" data-wg-splitted>par le «</a>PDMS <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\" data-wg-splitted>»</a> et ses conséquences dans les applications microfluidiques ».<em>Lab on a puce</em>, novembre 2006.<em>The Royal Society of Chemistry</em>, <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://doi.org/10.1039/b612140c\">https://doi.org/10.1039/b612140c</a></span></li>\n<li>Leung C.M., de Haan, P., Ronaldson-Bouchard, K. <em>et al.</em> Un guide de l'organe sur puce. <em>Nat Rev Methods Primers</em> <span style=\"font-weight: bolder;\">2</span>, 33 (2022). <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://doi.org/10.1038/s43586-022-00118-6\">https://doi.org/10.1038/s43586-022-00118-6</a></span></li>\n<li>Yanping Wang, Yanfeng Gao, Yongchun Pan, Dongtao Zhou, Yuta Liu, et al., « Tendances émergentes dans les systèmes « organ-on-a-puce » pour le criblage de médicaments », Acta Pharmaceutica Sinica B, volume 13, numéro 6, 2023, pages 2483-2509, ISSN 2211-3835, <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://doi.org/10.1016/j.apsb.2023.02.006\">https://doi.org/10.1016/j.apsb.2023.02.006</a></span>.</li>\n</ol>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ff60da elementor-widget elementor-widget-global elementor-global-18295 elementor-widget-pix-promo-box\" data-id=\"1ff60da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/17424049-optimized-DDI-Chip_blue2_2048x2048.webp\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"ORGANE SUR PUCE : L'AVENIR DE LA RECHERCHE ?\"><a href=\"https://darwin-microfluidics.com/fr/collections/organe-sur-puce-microfluidique\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Découvrez notre sélection !</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">ORGANE SUR PUCE : L'AVENIR DE LA RECHERCHE ?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explorez nos solutions de pointe pour la recherche et le développement avancés !</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Over the last few years, there have been major developments in organ-on-chip (OoC) platforms. Yet, there is no ‘one-fits-all’ model, and probably will never be considering the variety of applications for which those devices can be used. Thus, it is…</p>\n","protected":false},"author":3,"featured_media":18533,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[27,67],"tags":[],"class_list":["post-15987","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-comparisons"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Choisir les bons matériaux pour votre dispositif d'organe sur puce</title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Choisir les bons matériaux pour votre dispositif d'organe sur puce\">\n<meta property=\"og:description\" content=\"Au cours des dernières années, les plateformes « organ-on-puce  » (OoC) ont connu des avancées majeures. Il n’existe toutefois pas de modèle « universel », et il n’y en aura probablement jamais, compte tenu de la diversité des applications auxquelles ces dispositifs peuvent se prêter. Ainsi, il s’agit…\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-02-05T14:25:01+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:14:07+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\">\n\t<meta property=\"og:image:width\" content=\"447\">\n\t<meta property=\"og:image:height\" content=\"480\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"5 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Choosing the right materials for your organ-on-a-chip device\",\"datePublished\":\"2024-02-05T14:25:01+00:00\",\"dateModified\":\"2026-11-19T14:14:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\"},\"wordCount\":1049,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Comparisons &amp; buying guides\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\",\"url\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\",\"name\":\"Choosing the right materials for your organ-on-a-chip device\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"datePublished\":\"2024-02-05T14:25:01+00:00\",\"dateModified\":\"2026-11-19T14:14:07+00:00\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"width\":447,\"height\":480,\"caption\":\"table of materials for organ on chips\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Choosing the right materials for your organ-on-a-chip device\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Notre blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/fr\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Choosing the right materials for your organ-on-a-chip device","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","og_locale":"en_US","og_type":"article","og_title":"Choosing the right materials for your organ-on-a-chip device","og_description":"Over the last few years, there have been major developments in organ-on-chip (OoC) platforms. Yet, there is no &lsquo;one-fits-all&rsquo; model, and probably will never be considering the variety of applications for which those devices can be used. Thus, it is...","og_url":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-02-05T14:25:01+00:00","article_modified_time":"2026-11-19T14:14:07+00:00","og_image":[{"width":447,"height":480,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"5 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Choosing the right materials for your organ-on-a-chip device","datePublished":"2024-02-05T14:25:01+00:00","dateModified":"2026-11-19T14:14:07+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/"},"wordCount":1049,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","articleSection":["Cell culture &amp; organ-on-chip","Comparisons &amp; buying guides"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","url":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","name":"Choosing the right materials for your organ-on-a-chip device","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","datePublished":"2024-02-05T14:25:01+00:00","dateModified":"2026-11-19T14:14:07+00:00","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","width":447,"height":480,"caption":"table of materials for organ on chips"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Choosing the right materials for your organ-on-a-chip device"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Notre blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/15987","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=15987"}],"version-history":[{"count":8,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/15987/revisions"}],"predecessor-version":[{"id":19548,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/15987/revisions/19548"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/18533"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=15987"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=15987"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=15987"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}