{"id":30482,"date":"2024-11-21T10:40:02","date_gmt":"2024-11-21T09:40:02","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=30482"},"modified":"2026-11-19T15:33:40","modified_gmt":"2026-11-19T14:33:40","slug":"gamma-irradiation-sterilization-compatibility-chart","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/","title":{"rendered":"Gamma Irradiation – Sterilization Compatibility Chart"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"30482\" class=\"elementor elementor-30482\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-40a790d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"40a790d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0d74268\" data-id=\"0d74268\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-771b747 elementor-widget elementor-widget-text-editor\" data-id=\"771b747\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>L'irradiation gamma (γ-irradiation)</strong> est une méthode de <strong>stérilisation</strong> très efficace, particulièrement adaptée aux matériaux sensibles à la chaleur et à l'humidité. Elle est couramment utilisée dans les applications médicales, biologiques et <strong>microfluidiques</strong> car elle assure la stérilité sans soumettre les matériaux à des températures élevées.</p><p>Lors de l'irradiation gamma, les matériaux sont exposés à des rayons gamma de haute énergie dans un environnement contrôlé. Ces rayons pénètrent le matériau et perturbent l'ADN des micro-organismes, stérilisant efficacement les produits. Étant une méthode non thermique, l'irradiation gamma est particulièrement adaptée à la stérilisation des matériaux délicats qui ne peuvent pas supporter une chaleur élevée ou des processus de stérilisation à base de vapeur. Malgré son efficacité, une manipulation post-irradiation minutieuse est essentielle pour atténuer toute dégradation potentielle du matériau causée par l'exposition aux radiations.</p><p>Pour aider les ingénieurs et les chercheurs à évaluer le comportement de divers matériaux sous irradiation gamma, le tableau récapitulatif <a href=\"#chart\">ci-dessous</a>, issu de sources telles que <a href=\"https://www.qosina.com/\" target=\"_blank\" rel=\"noopener\">Qosina</a>, <a href=\"https://www.idex-hs.com/home\" target=\"_blank\" rel=\"noopener\">Idex</a>, et <a href=\"https://www.industrialspec.com/\" target=\"_blank\" rel=\"noopener\">Industrial Specialties Mfg.</a>, offre des évaluations de compatibilité.</p><p>Consultez ce tableau pour faire des choix éclairés et garantir des expériences sans contamination.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-c02c550 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"c02c550\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-473b577\" data-id=\"473b577\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-bb151e7 elementor-widget elementor-widget-text-editor\" data-id=\"bb151e7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>💡 La clé de notation de la compatibilité de stérilisation est la suivante :</p><ul><li>Bon = Peu ou Pas d'Effet</li><li>Modéré = Effet Léger à Modéré</li><li>Faible = Effet Modéré à Sévère (Non Recommandé)</li></ul><p>🚨 <em>Ce tableau est fourni à titre informatif uniquement et ne doit pas être considéré comme une garantie de performance des matériaux en stérilisation ou pour d'autres usages. Les utilisateurs sont responsables de l'évaluation de l'adéquation des matériaux et des processus pour leurs applications spécifiques, en tenant compte des considérations techniques et juridiques.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6265113 elementor-widget elementor-widget-heading\" data-id=\"6265113\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">☢️ Irradiation gamma : Tableau de Compatibilité de Stérilisation</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73d3c15 elementor-widget elementor-widget-shortcode\" data-id=\"73d3c15\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"chart\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-98\" class=\"tablepress tablepress-id-98\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Matériau</th><th class=\"column-2\">Irradiation gamma</th>\n</tr>\n</thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Aluminium</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Copolymère de Cyclo Oléfine (COC)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Polymère de Cyclo Oléfine (COP)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Éthylène Chlorotrifluoroéthylène (ECTFE)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Éthylène-Propylène-Diène Monomère (EPDM)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Éthylène Tétrafluoroéthylène (Tefzel - ETFE)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Éthylène Propylène Fluoré (FEP)</td><td class=\"column-2\">Acceptable</td>\n</tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Polyéthylène Haute Densité (PEHD)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Polypropylène Haute Densité (PPHD)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Polycarbonate Haute Température (PC)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Polyéthylène Basse Densité Linéaire (LLDP)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Polyéthylène Basse Densité (LDPE)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Néoprène</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Élastomère Thermoplastique Oléfinique (TPO)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Perfluoroalcoxy (PFA)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Perfluoroélastomère (FFKM)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Polyamide (Nylon)</td><td class=\"column-2\">Acceptable</td>\n</tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Élastomère Thermoplastique Polyamide (TPA)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">Polycarbonate (PC)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">Polychlorotrifluoroéthylène (PCTFE)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">Polydiméthylsiloxane (PDMS)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">Polyétheréthercétone (PEEK)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">Polyéthylène (PE)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">Polyméthacrylate de méthyle (PMMA)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">Polyoxyméthylène (Delrin)</td><td class=\"column-2\">Médiocre</td>\n</tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">Sulfure de Polyphénylène (PPS)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-28\">\n\t<td class=\"column-1\">Polyphénylsulfone (PPSU)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-29\">\n\t<td class=\"column-1\">Polypropylène (PP)</td><td class=\"column-2\">Acceptable</td>\n</tr>\n<tr class=\"row-30\">\n\t<td class=\"column-1\">Polystyrène (PS)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-31\">\n\t<td class=\"column-1\">Polysulfone (PSU)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-32\">\n\t<td class=\"column-1\">Polytétrafluoroéthylène (PTFE)</td><td class=\"column-2\">Médiocre</td>\n</tr>\n<tr class=\"row-33\">\n\t<td class=\"column-1\">Polyuréthane (PU)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-34\">\n\t<td class=\"column-1\">Polychlorure de Vinyle (PVC)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-35\">\n\t<td class=\"column-1\">Polychlorure de Vinyle (non plastifié - PVC)</td><td class=\"column-2\">Acceptable</td>\n</tr>\n<tr class=\"row-36\">\n\t<td class=\"column-1\">Polyfluorure de Vinyle (PVF)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-37\">\n\t<td class=\"column-1\">Silicone</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-38\">\n\t<td class=\"column-1\">Acier Inoxydable 316</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-39\">\n\t<td class=\"column-1\">Polyoléfine Thermoplastique (TPO)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-40\">\n\t<td class=\"column-1\">Polyuréthane Thermoplastique (TPU)</td><td class=\"column-2\">Bonne</td>\n</tr>\n<tr class=\"row-41\">\n\t<td class=\"column-1\">Polyéthylène à Très Haut Poids Moléculaire (UHMWPE)</td><td class=\"column-2\">Bonne</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-98 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4b0cce6 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4b0cce6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-fd6a542\" data-id=\"fd6a542\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-100b387 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"100b387\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Besoin d'aide pour votre projet microfluidique ?\"><a href=\"https://darwin-microfluidics.com/fr/contactez-nous\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Contactez nos experts !</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Besoin d'aide pour votre projet microfluidique ?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Nous pouvons vous simplifier la microfluidique !</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Gamma Irradiation (γ-irradiation) is a highly effective sterilization method, particularly suitable for materials that are sensitive to both heat and moisture. It is commonly used in medical, biological, and microfluidic applications because it ensures sterility without subjecting materials to high…</p>\n","protected":false},"author":4,"featured_media":30568,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[27,66,72],"tags":[],"class_list":["post-30482","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-chemical-compatibility","category-sterilization"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Irradiation gamma – Tableau de compatibilité pour la stérilisation</title>\n<meta name=\"description\" content=\"Consultez le tableau de compatibilité de stérilisation par irradiation gamma pour savoir quels matériaux sont compatibles avec les processus de stérilisation gamma.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Irradiation gamma – Tableau de compatibilité pour la stérilisation\">\n<meta property=\"og:description\" content=\"Consultez le tableau de compatibilité de stérilisation par irradiation gamma pour savoir quels matériaux sont compatibles avec les processus de stérilisation gamma.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-11-21T09:40:02+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:33:40+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization-1024x585.png\">\n\t<meta property=\"og:image:width\" content=\"1024\">\n\t<meta property=\"og:image:height\" content=\"585\">\n\t<meta property=\"og:image:type\" content=\"image/png\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"2 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"Gamma Irradiation – Sterilization Compatibility Chart\",\"datePublished\":\"2024-11-21T09:40:02+00:00\",\"dateModified\":\"2026-11-19T14:33:40+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\"},\"wordCount\":257,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Chemical compatibility charts\",\"Sterilization\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\",\"url\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\",\"name\":\"Gamma Irradiation – Sterilization Compatibility Chart\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png\",\"datePublished\":\"2024-11-21T09:40:02+00:00\",\"dateModified\":\"2026-11-19T14:33:40+00:00\",\"description\":\"Consultez le tableau de compatibilité de stérilisation par irradiation gamma pour savoir quels matériaux sont compatibles avec les processus de stérilisation gamma.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png\",\"width\":1792,\"height\":1024,\"caption\":\"Gamma irradiation sterilization\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Gamma Irradiation – Sterilization Compatibility Chart\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Notre blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/fr\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Gamma Irradiation – Sterilization Compatibility Chart","description":"Consultez le tableau de compatibilité de stérilisation par irradiation gamma pour savoir quels matériaux sont compatibles avec les processus de stérilisation gamma.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/","og_locale":"en_US","og_type":"article","og_title":"Gamma Irradiation – Sterilization Compatibility Chart","og_description":"Check out the Gamma Irradiation Sterilization Compatibility Chart to learn which materials are compatible with gamma sterilization processes.","og_url":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-11-21T09:40:02+00:00","article_modified_time":"2026-11-19T14:33:40+00:00","og_image":[{"width":1024,"height":585,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization-1024x585.png","type":"image/png"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"2 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"Gamma Irradiation – Sterilization Compatibility Chart","datePublished":"2024-11-21T09:40:02+00:00","dateModified":"2026-11-19T14:33:40+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/"},"wordCount":257,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png","articleSection":["Cell culture &amp; organ-on-chip","Chemical compatibility charts","Sterilization"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/","url":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/","name":"Gamma Irradiation – Sterilization Compatibility Chart","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png","datePublished":"2024-11-21T09:40:02+00:00","dateModified":"2026-11-19T14:33:40+00:00","description":"Consultez le tableau de compatibilité de stérilisation par irradiation gamma pour savoir quels matériaux sont compatibles avec les processus de stérilisation gamma.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png","width":1792,"height":1024,"caption":"Gamma irradiation sterilization"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/gamma-irradiation-sterilization-compatibility-chart/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Gamma Irradiation – Sterilization Compatibility Chart"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Notre blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Gamma-irradiation-sterilization.png","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30482","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=30482"}],"version-history":[{"count":19,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30482/revisions"}],"predecessor-version":[{"id":30593,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30482/revisions/30593"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/30568"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=30482"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=30482"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=30482"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}