{"id":14373,"date":"2023-02-22T14:44:34","date_gmt":"2023-02-22T13:44:34","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14373"},"modified":"2024-02-27T12:10:11","modified_gmt":"2024-02-27T11:10:11","slug":"recirculation-for-cell-culture-in-microfluidics","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/","title":{"rendered":"Recirculation for cell culture in microfluidics"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14373\" class=\"elementor elementor-14373\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-734e162 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"734e162\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-d7908cb\" data-id=\"d7908cb\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0afd1be elementor-widget elementor-widget-text-editor\" data-id=\"0afd1be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>I chip microfluidici possono fornire un ambiente biomimetico per la coltura cellulare e tissutale, preservando gli aspetti fondamentali del sistema biologico e integrando al contempo le analisi a valle. È persino possibile spingersi oltre, integrando un apporto continuo di nutrienti tramite l’ ricircolo e del mezzo di coltura. In questo tutorial presenteremo le diverse tecniche di “ ricircolo ” e i metodi disponibili per realizzarle.</p><p>In breve, il ricircolo si ottiene solitamente utilizzando una pompa peristaltica per riportare l’eluente in uscita nel serbatoio di ingresso, in modo che la sospensione possa attraversare nuovamente il dispositivo.</p><h2>Vantaggi del ricircolo nella coltura cellulare:</h2><ul><li>L'integrazione di ricircolo all'interno di un dispositivo microfluidico ci consentirà di avvicinarci un po' di più alla realtà, oltre che di comprendere meglio <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">l'assorbimento</a> dei farmaci, distribuzione, il loro metabolismo e la loro eliminazione. Infatti, ogni organo, tessuto o cellula del corpo umano è costantemente irrigato dai fluidi corporei, sia in un circuito aperto (saliva, liquido gastrico fluido, urina…) sia in un circuito chiuso (sangue, linfa, liquido pleurico fluido…).</li><li>A seconda dell'installazione, ciò può consentire l'eliminazione degli scarti, il che può migliorare notevolmente le prestazioni dell'esperimento e, ancora una volta, riprodurre la realtà.</li><li>La tecnica “ ricircolo ” consente inoltre di risparmiare terreno di coltura, che può risultare molto costoso nel caso delle cellule primarie, e arricchisce il terreno con fattori secreti dalle cellule. Tuttavia, va notato che la circolazione chiusa richiede che il terreno venga alimentato con CO₂ all’interno dell’ chip. Ciò può essere ottenuto utilizzando un materiale permeabile al gas oppure un terreno indipendente dalla CO₂ per brevi periodi (circa 2 ore).</li></ul><h2>ricircolo con un \" pompa peristaltica \" nella coltura cellulare</h2><p>Le pompe peristaltiche sono ampiamente utilizzate nella coltura cellulare, in quanto sono facili da usare e da collegare. Possono essere impiegate in una varietà di situazioni, ma nella maggior parte dei casi servono a far ricircolare l'fluido e attraverso un chip. Il numero di campioni che possono essere infusi in parallelo varia generalmente da 1 a 24, a seconda del numero di canali presenti sul testa della pompa.</p><p>Per definizione, le pompe peristaltiche generano un flusso pulsante. La frequenza e l’ampiezza delle oscillazioni variano da una pompa all’altra a seconda del numero di rulli, della loro frequenza di rotazione e del diametro dell’ tube e utilizzato. La maggior parte delle pompe peristaltiche è controllata da un software che consente di automatizzare protocolli quali l’iniezione periodica o semplici variazioni di flusso.</p><p>Nella maggior parte dei casi, tutti i tubi sono avvolti attorno a un rotore e garantiscono quindi la stessa portata in ciascun chip, il che può rappresentare un limite per alcuni studi. Tuttavia, stanno arrivando sul mercato nuovi modelli che consentono di infondere contemporaneamente e in modo indipendente diversi campioni. Oggi, specifiche formulazioni di tube per le pompe peristaltiche ne aumentano notevolmente la durata, garantendo prestazioni ottimali e riproducibili.</p><p>L'ricircolo e dei fluidi è possibile anche con un sistema miniaturizzato on-chip pompa peristaltica  basato su microcanali a controllo pneumatico, come riportato da Balagadd´e et al. <strong>[Balagadd´e et al., Science 2005]</strong>.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2fc8ab4 elementor-widget elementor-widget-image\" data-id=\"2fc8ab4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"220\" height=\"300\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-220x300.webp\" class=\"attachment-medium size-medium wp-image-14376\" alt=\"Immagine di un sistema “ ricircolo ” con il Reglo ICC pompa peristaltica di Ismatec e la piattaforma “organ-on-a-chip ” di Mesobiotech. Il ricircolo viene realizzato tramite 3-stop adattatori in platinoreticolo in silicone tubo e scanalato per adattatori a slitta Luer da Darwin Microfluidics\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-220x300.webp 220w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-752x1024.webp 752w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-768x1046.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-1128x1536.webp 1128w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-1504x2048.webp 1504w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp 1880w\" sizes=\"(max-width: 220px) 100vw, 220px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figura 1: Immagine di un sistema di ricircolo con la pompa peristaltica Reglo ICC di Ismatec e la piattaforma organe sur puce di Mesobiotech. Il ricircolo è realizzato tramite tubi in silicone vulcanizzato al platino a 3 vie tube e cannelé (barbed) collegati ad adattatori Luer Slip maschi di Darwin Microfluidics</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3a06c8 elementor-widget elementor-widget-global elementor-global-18292 elementor-widget-pix-promo-box\" data-id=\"e3a06c8\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Peristatic-pumps_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"PRONTO PER UNA GESTIONE DEI FLUIDI AFFIDABILE?\"><a href=\"https://darwin-microfluidics.com/it/collections/pompe-peristaltiche\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Scoprite la nostra selezione!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">PRONTO PER UNA GESTIONE DEI FLUIDI AFFIDABILE?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Esplora le nostre pompe peristaltiche per un'erogazione di fluidi costante e precisa nel tuo laboratorio</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-90b245b elementor-widget elementor-widget-text-editor\" data-id=\"90b245b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Altre configurazioni</h2><p>Oltre al pompaggio peristaltico, è possibile creare un circuito di iniezione utilizzando altre tecnologie di pompaggio. Questo metodo consiste in una rete di ingressi/uscite che possono essere collegati tra loro in una configurazione che consente un sistema a ricircolo con una portata che attraversa sempre il dispositivo microfluidico nella stessa direzione.</p><p>Per eseguire questo ciclo di iniezione, ti serviranno:</p><ul><li><span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https://darwin-microfluidics.com/it/prodotti/ob1-mk3-flow-controller?variant=7241063628845\">Regolatore di pressione</a></strong></span> (Sistema di controllo del flusso microfluidico a 4 canali)</li><li>Sensore di flusso (<span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https://darwin-microfluidics.com/it/prodotti/sensore-flusso-termico-microfluidico?variant=36067511105\">Sensore di flusso termico microfluidico MFS</a></strong></span>)</li><li>Valvola di iniezione (<span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https://darwin-microfluidics.com/it/prodotti/mux-ricircolo?variant=37496408506532\">Ricircolo MUX</a></strong></span>)</li><li>Dispositivo microfluidico (<a href=\"https://darwin-microfluidics.com/it/collections/organo-su-chip-microfluidico/prodotti/organ-on-a-chip-top-and-bottom-layers-pack-of-4\"><span style=\"text-decoration: underline; color: #0000ff;\"><strong>Organo microfluidico suChip</strong></span></a>)</li><li>Serbatoi di campione (<span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https://darwin-microfluidics.com/it/prodotti/50-ml-falcon-tubo-serbatoio-microfluidico-m-2-4-porta\">Serbatoio microfluidico</a></strong></span>)</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e541bc7 elementor-widget elementor-widget-image\" data-id=\"e541bc7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https://www.elveflow.com/microfluidics-application-packs/biology-packs/one-way-recirculation/\" target=\"_blank\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"264\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Recirculation-setup-Elveflow-1-300x264.webp\" class=\"attachment-medium size-medium wp-image-14377\" alt=\"Schema della configurazione “ ricircolo ” - Elveflow OB1\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Recirculation-setup-Elveflow-1-300x264.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Recirculation-setup-Elveflow-1-1024x900.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Recirculation-setup-Elveflow-1-768x675.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Recirculation-setup-Elveflow-1.webp 1050w\" sizes=\"(max-width: 300px) 100vw, 300px\">\t\t\t\t\t\t\t\t</a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figura 2: Illustrazione di un gruppo di ricircolo del kit di ricircolo Elveflow, presto disponibile. L'uso della valvola di iniezione consente il ricircolo in più posizioni. Tratto dal sito web di Elveflow. </figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1362c85 elementor-widget elementor-widget-text-editor\" data-id=\"1362c85\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Utilizzando un regolatore di pressione, il flusso risulterà ancora più regolare e privo di impulsi rispetto all’uso della pompa peristaltica. Questa configurazione consentirà la completa automazione dei vostri esperimenti, sia che durino 2 ore o 1 settimana con volumi limitati di terreno di coltura, sia che si tratti di applicazioni più avanzate come la modellizzazione di flussi biologici complessi.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Microfluidic chips can provide a biomimetic environment for cell and tissue culture, preserving key aspects of the biological system while integrating downstream analysis. It is even possible to go further by integrating a continuous supply of nutrients via recirculation of…</p>\n","protected":false},"author":3,"featured_media":14376,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[27,21],"tags":[],"class_list":["post-14373","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Ricircolo per la coltura cellulare nella microfluidica - Darwin Microfluidics</title>\n<meta name=\"description\" content=\"ricircolo Si ottiene solitamente reimmettendo l'eluente in uscita nel serbatoio di ingresso, in modo che la sospensione possa attraversare nuovamente il dispositivo.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Ricircolo per la coltura cellulare nella microfluidica - Darwin Microfluidics\">\n<meta property=\"og:description\" content=\"ricircolo Si ottiene solitamente reimmettendo l'eluente in uscita nel serbatoio di ingresso, in modo che la sospensione possa attraversare nuovamente il dispositivo.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-22T13:44:34+00:00\">\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:10:11+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp\">\n\t<meta property=\"og:image:width\" content=\"1880\">\n\t<meta property=\"og:image:height\" content=\"2560\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"4 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Recirculation for cell culture in microfluidics\",\"datePublished\":\"2023-02-22T13:44:34+00:00\",\"dateModified\":\"2024-02-27T11:10:11+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\"},\"wordCount\":697,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\",\"url\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\",\"name\":\"Recirculation for cell culture in microfluidics - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp\",\"datePublished\":\"2023-02-22T13:44:34+00:00\",\"dateModified\":\"2024-02-27T11:10:11+00:00\",\"description\":\"ricircolo Si ottiene solitamente reimmettendo l'eluente in uscita nel serbatoio di ingresso, in modo che la sospensione possa attraversare nuovamente il dispositivo.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp\",\"width\":1880,\"height\":2560,\"caption\":\"Picture of a recirculation system with the Reglo ICC peristaltic pump from Ismatec and the organ-on-a-chip platform from Mesobiotech. The recirculation is established through 3-stop platinum-cured silicone tubing and barbed to male Luer slip adaptaters from Darwin Microfluidics\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Recirculation for cell culture in microfluidics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Il nostro blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/it\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Recirculation for cell culture in microfluidics - Darwin Microfluidics","description":"ricircolo Si ottiene solitamente reimmettendo l'eluente in uscita nel serbatoio di ingresso, in modo che la sospensione possa attraversare nuovamente il dispositivo.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/","og_locale":"en_US","og_type":"article","og_title":"Recirculation for cell culture in microfluidics - Darwin Microfluidics","og_description":"Recirculation is usually achieved by returning the outlet eluent to the inlet tank so that the suspension can pass through the device again.","og_url":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T13:44:34+00:00","article_modified_time":"2024-02-27T11:10:11+00:00","og_image":[{"width":1880,"height":2560,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"4 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Recirculation for cell culture in microfluidics","datePublished":"2023-02-22T13:44:34+00:00","dateModified":"2024-02-27T11:10:11+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/"},"wordCount":697,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","articleSection":["Cell culture &amp; organ-on-chip","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/","url":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/","name":"Recirculation for cell culture in microfluidics - Darwin Microfluidics","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","datePublished":"2023-02-22T13:44:34+00:00","dateModified":"2024-02-27T11:10:11+00:00","description":"ricircolo Si ottiene solitamente reimmettendo l'eluente in uscita nel serbatoio di ingresso, in modo che la sospensione possa attraversare nuovamente il dispositivo.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","width":1880,"height":2560,"caption":"Picture of a recirculation system with the Reglo ICC peristaltic pump from Ismatec and the organ-on-a-chip platform from Mesobiotech. The recirculation is established through 3-stop platinum-cured silicone tubing and barbed to male Luer slip adaptaters from Darwin Microfluidics"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/recirculation-for-cell-culture-in-microfluidics/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Recirculation for cell culture in microfluidics"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Il nostro blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photography-of-a-recirculation-mesobiotech-device-with-a-reglo-ICC-peristaltic-pump-1-scaled.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14373","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14373"}],"version-history":[{"count":18,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14373/revisions"}],"predecessor-version":[{"id":18443,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14373/revisions/18443"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14376"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14373"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14373"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14373"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}