{"id":14504,"date":"2023-02-22T18:07:28","date_gmt":"2023-02-22T17:07:28","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14504"},"modified":"2024-07-16T12:08:01","modified_gmt":"2024-07-16T10:08:01","slug":"organ-on-chip-for-blood-brain-barrier-research","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/","title":{"rendered":"Organ-on-chip for blood-brain barrier research"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14504\" class=\"elementor elementor-14504\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-33f9a85 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"33f9a85\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-317c52a\" data-id=\"317c52a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-dd6f8cc elementor-widget elementor-widget-text-editor\" data-id=\"dd6f8cc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Combinando i principi della microfluidica, della microfabbricazione e delle tecniche di coltura cellulare, è emersa una nuova generazione di piattaforme di laboratorio, nota come \"organ-on-chip\". I sistemi organ-on-chip sono dispositivi microfluidici contenenti cellule vive. Questi dispositivi microfluidici sono in grado di ricreare i microambienti in modo più fedele rispetto ai precedenti modelli in vitro. I dispositivi microfluidici sono particolarmente adatti per modellare barriere biologiche, come la barriera emato-encefalica, poiché consentono di simulare il flusso sanguigno.</p><h2>Struttura e funzione della barriera emato-encefalica</h2><p>La barriera emato-encefalica (BBB) è lo strato di cellule che riveste i microvasi cerebrali e separa il sangue dai liquidi interstiziali del cervello. La funzione principale della barriera emato-encefalica è quella di fungere da barriera fisica e metabolica, consentendo il trasporto selettivo di sostanze nutritive ma impedendo alle sostanze tossiche presenti nel sangue di penetrare nel cervello.</p><p>La BBB è costituita da cellule endoteliali specializzate, circondate da una membrana basale e da altri quattro tipi di cellule: astrociti, periciti, neuroni e microglia. Questi cinque tipi di cellule, insieme alla membrana basale, costituiscono l’unità neurovascolare (figura 1) [1]. Tra le cellule endoteliali adiacenti della BBB si formano complessi proteici di tenuta denominati giunzioni strette. Di conseguenza, le cellule sono mantenute in stretta vicinanza l’una all’altra, occludendo così gli spazi intracellulari e impedendo il trasporto paracellulare. Questa elevata tenuta della barriera è caratteristica della BBB ed è fondamentale per il mantenimento dell’omeostasi cerebrale. Una compromissione locale della tenuta della barriera, con conseguente perdita attraverso la stessa, è associata a diverse malattie del sistema nervoso centrale (SNC) [2]. Comprendere e superare la BBB è essenziale per il trattamento delle malattie del SNC. I sistemi di somministrazione dei farmaci in grado di aprire temporaneamente la barriera, consentendo ai farmaci di attraversarla e raggiungere il cervello, rappresentano un’area di ricerca fondamentale per il trattamento delle malattie del SNC.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dd8c56f elementor-widget elementor-widget-image\" data-id=\"dd8c56f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"321\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1-768x385.webp\" class=\"attachment-medium_large size-medium_large wp-image-14506\" alt=\"Illustrazione dell'unità neurovascolare\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1-768x385.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1-300x150.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp 940w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figura 1. Illustrazione dell'unità neurovascolare [1]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ea79704 elementor-widget elementor-widget-text-editor\" data-id=\"ea79704\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Modelli in vitro della barriera emato-encefalica</h2><p>Negli ambienti artificiali, le condizioni possono essere mantenute sotto stretto controllo ed è possibile studiare comportamenti specifici in modo indipendente con interferenze minime da parte di altri fattori. Tradizionalmente, la BBB è stata ricostruita in vitro come modello statico utilizzando configurazioni di coltura cellulare convenzionali. I dispositivi microfluidici organ-on-chip offrono soluzioni a molti dei limiti dei precedenti modelli in vitro. Questi dispositivi possono essere progettati con architetture più realistiche e le loro ridotte dimensioni rappresentano meglio la geometria dei capillari nell'unità neurovascolare. Inoltre, impiegando la microfluidica anziché condurre esperimenti in una soluzione di volume (bulk solution), i modelli possono mostrare fenomeni fisiologici come flussi di fluidi e tensioni di taglio (shear stresses). Un altro vantaggio dei modelli di BBB-on-chip è la possibilità di integrare sensori per il monitoraggio in tempo reale [3].</p><h2>Barriera emato-encefalica su chip microfluidico</h2><p>Di seguito vengono presentati due dei primi dispositivi microfluidici che hanno fatto da pionieri nello sviluppo del BBB-on-chip e fornito la prova di principio (proof-of-principle) per diversi concetti promettenti. Verranno inoltre introdotti alcuni importanti aspetti di progettazione e parametri di validazione da considerare durante lo sviluppo di un dispositivo organ-on-chip per lo studio della BBB. Oggi, i chip pronti all'uso per applicazioni organ-on-chip sono disponibili in commercio o possono essere ordinati su misura.</p><p>Per quanto ci risulta, Booth e collaboratori sono stati i primi a pubblicare un modello di BBB su chip nel 2012 [4], seguito da un ulteriore articolo nel 2014 [5]. Il loro dispositivo, mostrato nella figura 2, comprende due canali incrociati in strati di PDMS, con una profondità di 200 µm e una larghezza rispettivamente di 2 mm e 5 mm. I due canali erano separati da una membrana di policarbonato poroso rivestita di fibronectina. Gli strati dei canali erano coperti da vetrini con elettrodi a film sottile in Ag/AgCl con una struttura di rilevamento a quattro punti posizionata sopra la membrana. Cellule endoteliali di topo (b.End3) e astrociti murini (C8D1A) sono stati co-coltivati sui lati opposti della membrana. È stata applicata una portata (flow rate) di 2,6 mL/min in entrambi i canali, che secondo i calcoli presentati nell'articolo corrispondeva a una tensione di taglio di 2 mPa sulle cellule endoteliali. La resistenza elettrica transendoteliale (TEER) è stata misurata tra 180 e 280 Vcm2 utilizzando gli elettrodi a film sottile integrati. Inoltre, la proteina di giunzione stretta ZO-1 è stata identificata mediante immunofluorescenza e sono stati condotti studi di permeabilità per confermare la funzione di barriera.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c118f93 elementor-widget elementor-widget-image\" data-id=\"c118f93\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"574\" height=\"295\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-2-1.webp\" class=\"attachment-medium_large size-medium_large wp-image-14508\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-2-1.webp 574w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-2-1-300x154.webp 300w\" sizes=\"(max-width: 574px) 100vw, 574px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figura 2. Illustrazione schematica e immagine del BBB-on-chip sviluppato da Booth et al. (Ristampato da Booth et al. [5])</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4c3267e elementor-widget elementor-widget-text-editor\" data-id=\"4c3267e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un altro dispositivo BBB completamente integrato è stato pubblicato da Griep et al. nel 2013 [6]. Il dispositivo era costituito da due strati di PDMS comprendenti canali con una larghezza di 500 µm e una profondità di 100 µm, con interposta una membrana in policarbonato rivestita di collagene. Cellule endoteliali microvascolari cerebrali umane (hCMEC/D3) sono state coltivate sulla sommità della membrana. Sono stati impiegati quattro fili di platino per monitorare il valore di TEER per un periodo di 7 giorni mediante misurazioni di spettroscopia d'impedenza. È stato ottenuto un valore medio di TEER pari a 28 Vcm2 ± 1,3 SEM). È stato osservato un incremento del TEER, fino a 120 Vcm2, applicando una portata di 2,5 mL/h, corrispondente a uno sforzo di taglio calcolato di 0,58 Pa.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-250128e elementor-widget elementor-widget-image\" data-id=\"250128e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"230\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-3-1.webp\" class=\"attachment-large size-large wp-image-14510\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-3-1.webp 940w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-3-1-300x108.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-3-1-768x276.webp 768w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figura 3. Illustrazione schematica degli strati del chip (a) e del chip assemblato (b), e immagine del BBB-on-chip sviluppato da Griep et al. (Ristampato da Griep et al. [6])</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-991830b elementor-widget elementor-widget-global elementor-global-18295 elementor-widget-pix-promo-box\" data-id=\"991830b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/17424049-optimized-DDI-Chip_blue2_2048x2048.webp\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"ORGANE SUR PUCE: IL FUTURO DELLA RICERCA?\"><a href=\"https://darwin-microfluidics.com/it/collections/organo-su-chip-microfluidico\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Scoprite la nostra selezione!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">ORGANE SUR PUCE: IL FUTURO DELLA RICERCA?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Esplora le nostre soluzioni all'avanguardia per la ricerca e lo sviluppo avanzati!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7b9a967 elementor-widget elementor-widget-text-editor\" data-id=\"7b9a967\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Materiale del chip per organ-on-chip</h2>\n<p>Il PDMS è stato ampiamente utilizzato per la fabbricazione di dispositivi organ-on-chip. Tra i vantaggi del PDMS vi sono la biocompatibilità e la trasparenza (240 nm – 1100 nm), il costo contenuto e la facilità di manipolazione, la possibilità di essere stampato ad alta risoluzione e la capacità di legarsi al vetro o al PDMS [7]. Tuttavia, esso risulta fortemente <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/hydrophobic-microfluidic-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">idrofobico</a>, il che può rappresentare un problema durante il riempimento dei canali o nell'ottenimento di un'adesione ermetica per evitare perdite nei chip. Inoltre, il deposito di elettrodi sulla superficie del PDMS risulta difficoltoso; pertanto, nei dispositivi dotati di elettrodi a film sottile strutturati viene spesso impiegato il vetro.</p>\n<h3>Cellule nei modelli di barriera emato-encefalica su chip</h3>\n<p>Il tipo di cellule utilizzate riveste grande importanza per la costruzione di modelli biologicamente rilevanti. Tuttavia, non è ancora chiaro in che modo le diverse cellule dell’unità neurovascolare contribuiscano alla funzione di barriera [8]. Per simulare la BBB umana, l’uso di cellule umane sarebbe ovviamente l’approccio più predittivo. Le cellule endoteliali dell’ capillare e cerebrale umano sono state ampiamente caratterizzate, ma presentano scarsa disponibilità e riproducibilità [1]. I recenti progressi nella derivazione di cellule staminali pluripotenti indotte umane (hiPSC) sono molto promettenti per superare tali difficoltà [9].</p>\n<p>La co-coltura di cellule endoteliali con altri tipi cellulari dell'unità neurovascolare promette di fornire una rappresentazione fisiologicamente più rilevante, poiché tali cellule influenzano anche la formazione e il mantenimento della barriera [10]. Numerosi studi su co-colture in modelli microfluidici di BBB sono già stati pubblicati, riguardanti principalmente cellule endoteliali con astrociti [4] [11], ma anche con neuroni [12] e periciti. Gli astrociti e le cellule endoteliali non sono in contatto diretto tra loro, bensì separati dalla lamina basale. All'interno dei dispositivi microfluidici, possono essere coltivati su lati opposti della membrana. Tuttavia, se lo spessore della membrana nel dispositivo risulta eccessivo, il contatto cellula-cellula sarà limitato. Per mimare l'ambiente tridimensionale della matrice extracellulare, sono stati impiegati idrogel come supporti (scaffold) per la semina cellulare all'interno delle camere microfluidiche [12].</p>\n<h3>Sforzo di taglio sulle cellule endoteliali</h3>\n<p>Le cellule endoteliali della BBB nell'unità neurovascolare sono sottoposte a una forza normale rispetto alla parete del vaso a causa della pressione sanguigna, nonché a uno <a href=\"https://darwin-microfluidics.com/it/blogs/reviews/sforzo-di-taglio-nei-dispositivi-microfluidici\">sforzo di taglio</a> (shear stress) generato dal flusso sanguigno, nella direzione del flusso stesso. È già stato documentato che gli sforzi di taglio influenzano la morfologia e la funzione delle cellule endoteliali, esercitando un effetto positivo sulla formazione della barriera [13]. I dispositivi organ-on-chip offrono il grande vantaggio di ben si prestare all'incorporazione del flusso di fluidi, a differenza di altre tipologie di dispositivi. I vasi sanguigni viventi presentano sezioni trasversali circolari, mentre i dispositivi microfluidici possiedono tipicamente sezioni trasversali rettangolari. In un tubo a sezione circolare, lo sforzo di taglio risulterà uniforme e costante sulle pareti a causa della simmetria cilindrica. Nel caso di una sezione rettangolare, invece, lo sforzo di taglio non sarà uniforme. Per ottenere lo sforzo più uniforme possibile in una sezione rettangolare, è possibile realizzare un profilo di flusso quanto più piatto possibile progettando canali in cui l'altezza sia notevolmente inferiore alla larghezza [14]. Lo sforzo di taglio fisiologico per i capillari cerebrali è pari a 0,3-2 Pa [2].</p>\n<p></p>\n<h3>Resistenza elettrica transendoteliale (TEER)</h3>\n<p></p>\n<p>Il TEER descrive la resistenza attraverso una barriera cellulare ed è spesso utilizzato come parametro di validazione per verificare se le cellule endoteliali nei modelli di BBB formino complessi di giunzioni strette [15]. Se le cellule endoteliali crescono correttamente e formano giunzioni strette con le cellule adiacenti, gli spazi intercellulari dello strato cellulare vengono occlusi e il flusso di corrente attraverso di esso viene limitato [16]. Ciò induce una maggiore resistenza alla corrente, che si riflette in valori di TEER più elevati. Il TEER viene spesso espresso normalizzato rispetto all’area della membrana nell’unità<sup>Ωcm²</sup>, come riportato di seguito, per facilitare il confronto diretto con altri modelli.</p>\n<p>𝑇𝐸𝐸𝑅 (Ω 𝑐𝑚<sup>2</sup>) = 𝑅𝑒𝑠𝑖𝑠𝑡𝑎𝑛𝑐𝑒 (Ω) × 𝐶𝑒𝑙𝑙 𝑐𝑢𝑙𝑡𝑢𝑟𝑒 𝑎𝑟𝑒𝑎 (𝑐𝑚<sup>2</sup>)</p>\n<p>Nei modelli di BBB on-chip, la misurazione del TEER costituisce un metodo rapido e non invasivo che consente una valutazione in tempo reale della qualità della barriera. Le misurazioni vengono eseguite applicando una bassa corrente elettrica attraverso lo strato cellulare e misurando l'entità dell'ostacolo opposto dalla barriera cellulare al passaggio della corrente stessa. I dispositivi organ-on-chip sono particolarmente adatti all'integrazione di sensori in grado di monitorare il TEER in tempo reale, operazione complessa in altre tipologie di dispositivi. I modelli <em>in vitro</em> della BBB devono raggiungere valori di TEER superiori a 150-200 Ωcm<sup>2</sup> per essere considerati accettabili [19]. Tale valore risulta inferiore di circa un fattore dieci rispetto ai risultati <em>in vivo</em> riportati in letteratura. La ragione per cui si accetta un valore di TEER sensibilmente inferiore è da attribuire alle condizioni semplificate proprie dei sistemi <em>in vitro</em>.</p>\n<h3>Permeabilità dei modelli di barriera emato-encefalica su chip</h3>\n<p>I modelli organ-on-chip possono fornire direttamente informazioni sulla funzione di barriera testandone la permeabilità a diverse sostanze. Risulta utile quantificare la permeabilità in modo tale da poterla agevolmente confrontare con i dati <em>in vivo</em>. Il trasporto passivo attraverso la barriera può essere quantificato a partire dal coefficiente di permeabilità di un analita che fluisce attraverso il chip. È opportuno evidenziare che fattori diversi dalla diffusione possono contribuire al trasporto, quali il flusso convettivo in presenza di discontinuità nella barriera cellulare e il flusso osmotico dovuto a differenze di concentrazione dei soluti tra i canali. Tale inconveniente può essere evitato controllando la concentrazione dei soluti nei canali e mantenendo la medesima pressione in entrambi i canali durante gli esperimenti. Poiché il trasporto di composti idrofili attraverso la barriera risulta fortemente limitato, tali composti, marcati con traccianti fluorescenti, vengono frequentemente impiegati negli studi di permeabilità. La permeabilità può quindi essere visualizzata mediante microscopia a fluorescenza.</p>\n<p><strong>Scritto da Emma Thomée, dottoranda del progetto MAMI, con il finanziamento del programma di ricerca e innovazione “Orizzonte 2020” dell’Unione Europea, nell’ambito dell’accordo di sovvenzione n. 766007.</strong></p>\n<h3>Bibliografia</h3>\n<p></p>\n<ol>\n<li>Abbott, N.J., et al., <em>Structure and function of the blood-brain barrier.</em> Neurobiol Dis, 2010. <strong>37</strong>(1): p. 13-25.</li>\n<li>Wong, A.D., et al.,<em>La barriera emato-encefalica: una prospettiva ingegneristica.</em>Front Neuroeng, 2013.<strong>6</strong>: p. 7.</li>\n<li>Bhatia, S.N. and D.E. Ingber, <em>Microfluidic organs-on-chips.</em> Nat Biotechnol, 2014. <strong>32</strong>(8): p. 760-72.</li>\n<li>Booth, R. and H. Kim, <em>Characterization of a microfluidic in vitro model of the blood-brain barrier ([small mu ]BBB).</em> Lab on a Chip, 2012. <strong>12</strong>(10): p. 1784-1792.</li>\n<li>Booth, R. and H. Kim, <em>Permeability analysis of neuroactive drugs through a dynamic microfluidic in vitro blood-brain barrier model.</em> Ann Biomed Eng, 2014. <strong>42</strong>(12): p. 2379-91.</li>\n<li>Griep, L.M., et al., <em>BBB on chip: microfluidic platform to mechanically and biochemically modulate blood-brain barrier function.</em> Biomed Microdevices, 2013. <strong>15</strong>(1): p. 145-50.</li>\n<li>Sia, S.K. e G.M. Whitesides,<em>Dispositivi microfluidici realizzati in poli(dimetilsilossano) per studi biologici.</em>Electrophoresis, 2003.<strong>24</strong>(21): pagg. 3563-76.</li>\n<li>Hawkins, B.T. and T.P. Davis, <em>The Blood-Brain Barrier/Neurovascular Unit in Health and Disease.</em> Pharmacological Reviews, 2005. <strong>57</strong>(2): p. 173.</li>\n<li>Pamies, D., T. Hartung, e H.T. Hogberg, <em>Biological and medical applications of a brain-on-a-chip.</em> Experimental Biology and Medicine, 2014. <strong>239</strong>(9): p. 1096-1107.</li>\n<li>Serlin, Y., et al., <em>Anatomy and Physiology of the Blood-Brain Barrier.</em> Seminars in cell & developmental biology, 2015. <strong>38</strong>: p. 2-6.</li>\n<li>Bang, S., et al., <em>A Low Permeability Microfluidic Blood-Brain Barrier Platform with Direct Contact between Perfusable Vascular Network and Astrocytes.</em> Scientific Reports, 2017. <strong>7</strong>(1): p. 8083.</li>\n<li>Adriani, G., et al., <em>A 3D neurovascular microfluidic model consisting of neurons, astrocytes and cerebral endothelial cells as a blood-brain barrier.</em> Lab On A Chip, 2017. <strong>17</strong>(3): p. 448-459.</li>\n<li>Dewey, C.F., et al., <em>The dynamic response of vascular endothelial cells to fluid shear stress.</em> J Biomech Eng, 1981. <strong>103</strong>(3): p. 177-85.</li>\n<li>van der Helm, M.W., et al., <em>Microfluidic organ-on-chip technology for blood-brain barrier research.</em> Tissue Barriers, 2016. <strong>4</strong>(1): p. e1142493.</li>\n<li>Srinivasan, B., et al., <em>TEER measurement techniques for in vitro barrier model systems.</em> J Lab Autom, 2015. <strong>20</strong>(2): p. 107-26.</li>\n<li>Thuenauer, R., E. Rodriguez-Boulan, e W. Römer, <em>Microfluidic approaches for epithelial cell layer culture and characterisation.</em> Analyst, 2014. <strong>139</strong>(13): p. 3206-18.</li>\n<li>Benson, K., S. Cramer, e H.J. Galla, <em>Impedance-based cell monitoring: barrier properties and beyond.</em> Fluids Barriers CNS, 2013. <strong>10</strong>(1): p. 5.</li>\n<li>Wegener, J. e J. Seebach, <em>Experimental tools to monitor the dynamics of endothelial barrier function: a survey of in vitro approaches.</em> Cell Tissue Res, 2014. <strong>355</strong>(3): p. 485-514.</li>\n<li>Reichel, A., D.J. Begley, e N.J. Abbott, <em>An overview of in vitro techniques for blood-brain barrier studies.</em> Methods Mol Med, 2003. <strong>89</strong>: p. 307-24.</li>\n</ol>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-523c045 elementor-widget elementor-widget-global elementor-global-18295 elementor-widget-pix-promo-box\" data-id=\"523c045\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/17424049-optimized-DDI-Chip_blue2_2048x2048.webp\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"ORGANE SUR PUCE: IL FUTURO DELLA RICERCA?\"><a href=\"https://darwin-microfluidics.com/it/collections/organo-su-chip-microfluidico\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Scoprite la nostra selezione!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">ORGANE SUR PUCE: IL FUTURO DELLA RICERCA?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Esplora le nostre soluzioni all'avanguardia per la ricerca e lo sviluppo avanzati!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>By combining the principles of microfluidics, microfabrication, and cell culturing techniques, a new generation of laboratory platforms has emerged, known as “organ-on-chip”. Organ-on-chip systems are microfluidic devices containing living cells. These microfluidic devices can better recapitulate microenvironments compared to previous…</p>\n","protected":false},"author":3,"featured_media":14506,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[27,21],"tags":[],"class_list":["post-14504","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Organ-on-chip e per la ricerca sulla barriera emato-encefalica</title>\n<meta name=\"description\" content=\"I sistemi organ-on-chip sono dispositivi microfluidici contenenti cellule vive. Scopri come possono replicare la barriera emato-encefalica!\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Organ-on-chip e per la ricerca sulla barriera emato-encefalica\">\n<meta property=\"og:description\" content=\"I sistemi organ-on-chip sono dispositivi microfluidici contenenti cellule vive. Scopri come possono replicare la barriera emato-encefalica!\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-22T17:07:28+00:00\">\n<meta property=\"article:modified_time\" content=\"2024-07-16T10:08:01+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp\">\n\t<meta property=\"og:image:width\" content=\"940\">\n\t<meta property=\"og:image:height\" content=\"471\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"11 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Organ-on-chip for blood-brain barrier research\",\"datePublished\":\"2023-02-22T17:07:28+00:00\",\"dateModified\":\"2024-07-16T10:08:01+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\"},\"wordCount\":2184,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\",\"url\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\",\"name\":\"Organ-on-chip for blood-brain barrier research\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp\",\"datePublished\":\"2023-02-22T17:07:28+00:00\",\"dateModified\":\"2024-07-16T10:08:01+00:00\",\"description\":\"I sistemi organ-on-chip sono dispositivi microfluidici contenenti cellule vive. Scopri come possono replicare la barriera emato-encefalica!\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp\",\"width\":940,\"height\":471,\"caption\":\"Illustration of the neurovascular unit\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Organ-on-chip for blood-brain barrier research\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Il nostro blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/it\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Organ-on-chip for blood-brain barrier research","description":"I sistemi organ-on-chip sono dispositivi microfluidici contenenti cellule vive. Scopri come possono replicare la barriera emato-encefalica!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/","og_locale":"en_US","og_type":"article","og_title":"Organ-on-chip for blood-brain barrier research","og_description":"Organ-on-chip systems are microfluidic devices containing living cells. Find out how they can replicate the blood-brain barrier!","og_url":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T17:07:28+00:00","article_modified_time":"2024-07-16T10:08:01+00:00","og_image":[{"width":940,"height":471,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"11 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Organ-on-chip for blood-brain barrier research","datePublished":"2023-02-22T17:07:28+00:00","dateModified":"2024-07-16T10:08:01+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/"},"wordCount":2184,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","articleSection":["Cell culture &amp; organ-on-chip","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/","url":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/","name":"Organ-on-chip for blood-brain barrier research","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","datePublished":"2023-02-22T17:07:28+00:00","dateModified":"2024-07-16T10:08:01+00:00","description":"I sistemi organ-on-chip sono dispositivi microfluidici contenenti cellule vive. Scopri come possono replicare la barriera emato-encefalica!","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","width":940,"height":471,"caption":"Illustration of the neurovascular unit"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/organ-on-chip-for-blood-brain-barrier-research/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Organ-on-chip for blood-brain barrier research"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Il nostro blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/BBB_review-1-1.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14504","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14504"}],"version-history":[{"count":15,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14504/revisions"}],"predecessor-version":[{"id":25608,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14504/revisions/25608"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14506"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14504"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14504"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14504"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}