{"id":14528,"date":"2023-02-22T18:28:50","date_gmt":"2023-02-22T17:28:50","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14528"},"modified":"2024-02-27T12:02:50","modified_gmt":"2024-02-27T11:02:50","slug":"the-most-used-microfabrication-materials-for-microfluidics","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/","title":{"rendered":"The most used microfabrication materials for microfluidics"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14528\" class=\"elementor elementor-14528\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7964d23 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7964d23\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-467fa74\" data-id=\"467fa74\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-af6f594 elementor-widget elementor-widget-text-editor\" data-id=\"af6f594\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>La scelta del materiale giusto per lo sviluppo di dispositivi microfluidici è un passaggio critico e tutt'altro che banale; il substrato selezionato deve infatti coniugare proprietà ottiche vicine a quelle del vetro (o idealmente della silice fusa) per un'analisi ottimale, caratteristiche superficiali che prevengano l'adsorbimento di biomolecole e l'elettrosmosi, oltre alla capacità di riprodurre con precisione strutture micrometriche.</p><p>(Poli)dimetilsilossano (PDMS), poli(metilmetacrilato) (PMMA), policarbonato (PC), polistirene (PS), polimmide e polietilene (PE) sono alcuni dei materiali polimerici comunemente impiegati nella produzione di chip. Tra questi, il PDMS rappresenta il substrato più diffuso. Più recentemente, la resina SU-8 si è affacciata sul mercato della microfabbricazione per i chip microfluidici. Anche il copolimero di olefina ciclica (COC) e il polietilenglicole diacrilato (PEGDA) sono ampiamente utilizzati nella produzione di dispositivi microfluidici.</p><p>In questa rassegna, il nostro team di esperti vi offre una panoramica esaustiva dei materiali più utilizzati nella microfluidica, consentendovi di selezionare quello più adatto alla vostra specifica applicazione.</p><h3>I materiali più comunemente utilizzati nella microfluidica</h3><p>La fabbricazione con i polimeri risulta agevole e il loro impiego riduce sensibilmente tempi, complessità e costi di prototipazione e produzione. Generalmente, i sistemi microfluidici vengono realizzati tramite stampaggio e bonding di repliche in elastomeri come il PDMS, oppure in termoplastiche come PMMA o PC. Altri materiali riscuotono un apprezzamento crescente nel campo della microfluidica, tra cui il COC e la resina SU-8. Questi polimeri devono il loro successo a 4 proprietà fondamentali: biocompatibilità, trasparenza, basso costo e, naturalmente, l'assenza di vincoli di copyright.</p><h4>Polidimetilsilossano o PDMS</h4><p>Una quota significativa di dispositivi microfluidici è realizzata in PDMS. Uno dei principali vantaggi di questo materiale risiede nella sua elevata trasparenza ottica nello spettro visibile e ultravioletto, caratteristica che lo rende idoneo a numerose applicazioni basate sulla fluorescenza. Un ulteriore punto di forza del PDMS è la sua permeabilità ai gas, che consente la coltura cellulare all'interno di dispositivi microfluidici fabbricati con questo substrato. Anche il processo produttivo risulta agevolato, poiché i chip vengono ottenuti semplicemente a partire da uno stampo recante il rilievo negativo del pattern desiderato. Tale pattern pre-strutturato può essere realizzato mediante tecniche standard di <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/photolithography-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">fotolitografia</a>, richiedendo inoltre un'infrastruttura in camera bianca minima per l'assemblaggio dei chip in PDMS. Il PDMS si presta ottimamente alle tecniche di prototipazione, confermandosi un materiale d'elezione nel settore della microfluidica.</p><p>Nonostante i numerosi vantaggi, sono stati segnalati alcuni inconvenienti legati all'uso del PDMS come dispositivo per l'<a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">assorbimento</a> di farmaci <em>[Regehr KJ et al. 2009 Lab Chip]</em> o di altre molecole in seguito all'ossidazione del polimero <em>[McDonald et al. 2000 Electroph.]</em>, circostanza che ha spinto i ricercatori a sviluppare dispositivi avvalendosi di materiali alternativi. Ulteriori svantaggi associati al PDMS comprendono, ad esempio, il gonfiore in presenza di solventi organici (che limita il campo delle applicazioni microfluidiche), la ridotta resistenza meccanica (con conseguente collasso delle strutture ad alto rapporto d'aspetto presenti nel dispositivo) e l'instabilità dei trattamenti superficiali <em>[Paul et al. 2007 Electroph.]</em>.</p><h4>Polimetilmetacrilato o PMMA</h4><p>Il PMMA è un polimero termoplastico il cui monomero è il metilmetacrilato (MMA). Questo polimero è noto soprattutto con il suo primo nome commerciale, Plexiglas. Il PMMA presenta molteplici vantaggi, tra cui trasparenza, resistenza e natura amorfa. Garantisce pertanto un'eccellente trasmissione della luce, pari fino al 92% della luce visibile, superando in tal senso il vetro <em>[Sito web Good Fellow]</em>.</p><p>Il PMMA è relativamente sensibile ai graffi (in misura maggiore rispetto alle tradizionali lenti minerali) e tende a infragilire in presenza di additivi. Mostra inoltre una resistenza relativamente modesta a numerosi agenti chimici e si dissolve in svariati solventi organici. La sua stabilità ambientale risulta tuttavia superiore a quella della maggior parte delle altre materie plastiche.</p><h4>Policarbonato o PC</h4><p>Il PC è un polimero termoplastico. Rispetto ad altri materiali impiegati nella microfluidica, come ad esempio il COC (copolimero di olefina ciclica), risulta meno <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/hydrophobic-microfluidic-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">idrofobico</a>, garantendo pertanto un migliore comportamento di riempimento dei canali. Trova impiego ideale in applicazioni ad alta temperatura come la PCR.</p><p>Il principale svantaggio del policarbonato è costituito dalla sua fluorescenza intrinseca relativamente elevata, se paragonata ad esempio a quella del PMMA. Tale limite risulta fortemente penalizzante per la microscopia a fluorescenza, restringendone di conseguenza l'impiego.</p><h4>Copolimero di olefina ciclica o COC</h4><p>Il copolimero di olefina ciclica (COC) è un polimero amorfo. Si tratta di una classe di polimeri relativamente recente rispetto a materiali tradizionali quali il polipropilene e il polietilene. Il COC rappresenta un substrato particolarmente adatto per le applicazioni microfluidiche: la lista dei suoi vantaggi è infatti estesa e comprende un'ottima biocompatibilità, basse proprietà di <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">assorbimento</a> dell'acqua, buona resistenza chimica e un'elevata trasparenza nello spettro UV profondo.</p><p>Grazie alle sue molteplici proprietà, il COC può naturalmente trovare impiego nella produzione di chip in svariati ambiti, ad esempio per l'analisi di parametri quali i gas ematici, la concentrazione di glucosio e lattato o la determinazione dei livelli di ematocrito. Inoltre, poiché le pareti dei canali sono trasparenti ai raggi UV, consentono l'impiego di iniziatori UV come il benzofenone, ampiamente utilizzato nel Western blotting.</p><h4>Resina SU-8</h4><p>La SU-8 è una resina fotosensibile negativa comunemente impiegata nella fabbricazione di microsistemi. È composta da resina epossidica, propilen carbonato, un iniziatore a base di arilsulfonio e un solvente organico. Per via della sua composizione, la SU-8 si configura come un polimero ad alta viscosità, steso in spessori compresi tra 1 micrometro e 2 millimetri e lavorato generalmente mediante <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/photolithography-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">fotolitografia</a>. Trova un impiego crescente nella fabbricazione di stampi grazie alla sua eccellente stabilità chimica nei confronti di diversi acidi e basi, nonché all'elevata stabilità termica. Inoltre, la SU-8 vanta affidabilità meccanica, trasparenza ottica e idrofilia. Tali caratteristiche rendono la SU-8 un materiale estremamente interessante per un'ampia gamma di applicazioni, tra cui naturalmente quelle microfluidiche, oltre che per la microottica, la micro-lavorazione meccanica, il packaging e le applicazioni analitiche.</p><p>La resina SU-8 viene raramente utilizzata come chip indipendente, trovando invece impiego come stampo in combinazione con altri materiali quali il PDMS o il silicone.</p><h4>Idrogel di polietilenglicole o PEG</h4><p>I PEG sono idrogel che offrono vantaggi significativi rispetto ad altri biomateriali. A differenza di questi ultimi, infatti, i PEG sono di sintesi, consentendo un controllo assoluto delle proprietà meccaniche, quali il modulo elastico e la velocità di degradazione. Ciò comporta inoltre una minore variabilità lotto-lotto rispetto ai materiali di origine naturale. La composizione chimica di tali idrogel conferisce loro un forte carattere idrofilo, resistenza all'adsorbimento proteico e biocompatibilità. Esiste una varietà di gruppi chimici che possono essere incorporati nei macromeri di PEG per agevolare la polimerizzazione e la reticolazione del network (acrilato, metacrilato, vinil etere, norbornene, ecc.) <em>[Amy H et al. 2013 Chem J]</em>.</p><p>Tra le proprietà dei materiali che possono rivestire un'importanza fondamentale figurano la lavorabilità meccanica, la carica superficiale, l'adsorbimento molecolare, la mobilità del flusso elettroosmotico, le caratteristiche ottiche e molte altre. La scelta del substrato risulta pertanto cruciale sia per il processo produttivo sia per la riuscita applicazione del dispositivo. Per assistervi nella scelta, Darwin Microfluidics propone un'ampia gamma di dispositivi microfluidici che combinano design differenti e materiali compatibili con una vasta gamma di applicazioni.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68c72a0 elementor-widget elementor-widget-global elementor-global-18322 elementor-widget-pix-promo-box\" data-id=\"68c72a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Microfabrication_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"CERCHI LA PRECISIONE SU SCALA NANOMETRICA?\"><a href=\"https://darwin-microfluidics.com/it/collections/microfabrication\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Scoprite la nostra selezione!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">CERCHI LA PRECISIONE SU SCALA NANOMETRICA?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Esplorate le nostre soluzioni di microfabbricazione per una produzione precisa e scalabile!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Choosing the right material for the development of microfluidic devices is critical and not insignificant, as the chosen material must combine optical qualities close to those of glass (or ideally fused silica) for optimal detection, surface properties avoiding adsorption of…</p>\n","protected":false},"author":3,"featured_media":14757,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[25,21],"tags":[],"class_list":["post-14528","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-microfabrication","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>The most used microfabrication materials for microfluidics</title>\n<meta name=\"description\" content=\"In questa rassegna, il nostro team di esperti offre una panoramica approfondita dei materiali più utilizzati nella microfluidica, per aiutarvi a scegliere quello ideale!\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"The most used microfabrication materials for microfluidics\">\n<meta property=\"og:description\" content=\"In questa rassegna, il nostro team di esperti offre una panoramica approfondita dei materiali più utilizzati nella microfluidica, per aiutarvi a scegliere quello ideale!\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-22T17:28:50+00:00\">\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:02:50+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp\">\n\t<meta property=\"og:image:width\" content=\"1000\">\n\t<meta property=\"og:image:height\" content=\"1000\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"5 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"The most used microfabrication materials for microfluidics\",\"datePublished\":\"2023-02-22T17:28:50+00:00\",\"dateModified\":\"2024-02-27T11:02:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\"},\"wordCount\":1096,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp\",\"articleSection\":[\"Microfabrication\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\",\"url\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\",\"name\":\"The most used microfabrication materials for microfluidics\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp\",\"datePublished\":\"2023-02-22T17:28:50+00:00\",\"dateModified\":\"2024-02-27T11:02:50+00:00\",\"description\":\"In questa rassegna, il nostro team di esperti offre una panoramica approfondita dei materiali più utilizzati nella microfluidica, per aiutarvi a scegliere quello ideale!\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp\",\"width\":1000,\"height\":1000,\"caption\":\"photograph of a PDMS bottle\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"The most used microfabrication materials for microfluidics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Il nostro blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/it\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"The most used microfabrication materials for microfluidics","description":"In questa rassegna, il nostro team di esperti offre una panoramica approfondita dei materiali più utilizzati nella microfluidica, per aiutarvi a scegliere quello ideale!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/","og_locale":"en_US","og_type":"article","og_title":"The most used microfabrication materials for microfluidics","og_description":"In this review, our team of experts gives you a good overview of the most used materials in microfluidics, so you can choose the best one!","og_url":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T17:28:50+00:00","article_modified_time":"2024-02-27T11:02:50+00:00","og_image":[{"width":1000,"height":1000,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"5 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"The most used microfabrication materials for microfluidics","datePublished":"2023-02-22T17:28:50+00:00","dateModified":"2024-02-27T11:02:50+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/"},"wordCount":1096,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","articleSection":["Microfabrication","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/","url":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/","name":"The most used microfabrication materials for microfluidics","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","datePublished":"2023-02-22T17:28:50+00:00","dateModified":"2024-02-27T11:02:50+00:00","description":"In questa rassegna, il nostro team di esperti offre una panoramica approfondita dei materiali più utilizzati nella microfluidica, per aiutarvi a scegliere quello ideale!","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","width":1000,"height":1000,"caption":"photograph of a PDMS bottle"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/the-most-used-microfabrication-materials-for-microfluidics/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"The most used microfabrication materials for microfluidics"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Il nostro blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/PDMS-Sylgard-1.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14528","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14528"}],"version-history":[{"count":8,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14528/revisions"}],"predecessor-version":[{"id":18409,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14528/revisions/18409"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14757"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14528"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14528"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14528"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}