{"id":14543,"date":"2023-02-23T13:01:12","date_gmt":"2023-02-23T12:01:12","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14543"},"modified":"2026-11-19T15:13:14","modified_gmt":"2026-11-19T14:13:14","slug":"how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/","title":{"rendered":"How to Connect your Tubing to a ChipShop Microfluidic Chip?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14543\" class=\"elementor elementor-14543\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-bf71543 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"bf71543\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-37fa4a7\" data-id=\"37fa4a7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2f5faa1 elementor-widget elementor-widget-text-editor\" data-id=\"2f5faa1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https://darwin-microfluidics.com/it/categorie/chip-microfluidico/?page=1&amp;rb_brand=microfluidic%20ChipShop\"><strong>I chip microfluidici ChipShop</strong></a> sono compatibili con <a href=\"https://darwin-microfluidics.com/it/categorie/silicone-tygon-tubing/\"><strong>materiali a pareti morbide tube</strong></a>, come il silicone o il Tygon, comunemente utilizzati con <a href=\"https://darwin-microfluidics.com/it/categorie/pompe-peristaltiche/\">le pompe peristaltiche</a> e <a href=\"https://darwin-microfluidics.com/it/categorie/pompa-a-siringa/\">le pompe a siringa</a> grazie alla loro flessibilità e facilità di manipolazione.</p><p>Tuttavia, quando si collegano questi chip a <a href=\"https://darwin-microfluidics.com/it/categorie/ptfe-peek-fep-tubing/\"><strong>materiali rigidi tube</strong></a> come l'PTFE o o il PEEK.</p><p>In questa guida esploreremo soluzioni pratiche per realizzare collegamenti sicuri ed efficienti tra i chip microfluidici ChipShop e sia i contenitori a pareti morbide che quelli rigidi tube.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-a37e859 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a37e859\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a024451\" data-id=\"a024451\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d028c1a elementor-widget elementor-widget-heading\" data-id=\"d028c1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Collegare un chip ChipShop a Soft-Walled tube</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-afd8b27 elementor-widget elementor-widget-text-editor\" data-id=\"afd8b27\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>I chip microfluidici ChipShop sono dotati di <a href=\"https://darwin-microfluidics.com/it/prodotti/male-luer-fluid-connectors\">connettori Luer</a> e <a href=\"https://darwin-microfluidics.com/it/prodotti/connettori-fluido-mini-luer-maschio\">mini Luer</a> , che sono conici e hanno un diametro alla base di circa 1 mm. Questi connettori sono progettati per integrarsi facilmente con le tube a pareti morbide, comunemente utilizzate nelle configurazioni microfluidiche.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3273529 elementor-widget elementor-widget-image\" data-id=\"3273529\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"300\" height=\"176\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/FI_508_specs-1_large-1-1-300x176.webp\" class=\"attachment-medium size-medium wp-image-14546\" alt=\"Disegno illustrativo di un connettore Luer e relative dimensioni\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/FI_508_specs-1_large-1-1-300x176.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/FI_508_specs-1_large-1-1.webp 480w\" sizes=\"(max-width: 300px) 100vw, 300px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Esempio di connettore Luer e relative dimensioni.</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6881930 elementor-widget elementor-widget-heading\" data-id=\"6881930\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Procedura</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-21ba675 elementor-widget elementor-widget-text-editor\" data-id=\"21ba675\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Taglia l’ tube e alla lunghezza desiderata utilizzando una lama affilata o un taglier tube e per ottenere un taglio netto e uniforme.</li><li>Inserire delicatamente l'tube e sul connettore Luer conico. Partire dalla punta del connettore e farlo scorrere verso l'alto fino a quando non si adagia perfettamente sul cono.</li><li>Assicurarsi che il connettore a spina ( tube ) sia fissato saldamente attorno al connettore, senza lasciare spazi visibili. Un collegamento correttamente inserito non dovrebbe richiedere una forza eccessiva per il montaggio né presentare il rischio di distacco durante il funzionamento.</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2b52676 elementor-widget elementor-widget-text-editor\" data-id=\"2b52676\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>💡 <strong>Suggerimento</strong>: per creare un collegamento sicuro e a tenuta stagna, è importante scegliere un raccordo a vite ( tube ) con il diametro interno (ID) corretto. Il raccordo a vite ( tube ) deve essere sufficientemente grande, con un diametro interno di almeno 0,5 mm, per poter scorrere sul connettore e adattarsi al raccordo Luer. Il raccordo a vite ( tube ) deve inoltre essere sufficientemente piccolo, in genere inferiore a 1 mm, per garantire un accoppiamento perfetto ed evitare perdite.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4aa9375 elementor-widget elementor-widget-image\" data-id=\"4aa9375\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"480\" height=\"360\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/20190515_123338_large-1.webp\" class=\"attachment-medium_large size-medium_large wp-image-14547\" alt=\"Collegamento tra un dispositivo “ tube ” a pareti morbide e un dispositivo microfluidico ChiShop.\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/20190515_123338_large-1.webp 480w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/20190515_123338_large-1-300x225.webp 300w\" sizes=\"(max-width: 480px) 100vw, 480px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Collegamento tra un dispositivo “ tube ” a pareti morbide e un chip microfluidico ChiShop.</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-a084add elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"a084add\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f9dd5dd\" data-id=\"f9dd5dd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8c695ee elementor-widget elementor-widget-heading\" data-id=\"8c695ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Collegare un chip ChipShop a Rigid tube</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e71c3f elementor-widget elementor-widget-text-editor\" data-id=\"8e71c3f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>I chip microfluidici ChipShop sono progettati per l'tube e a pareti morbide, ma è possibile collegare anche tube rigidi, come l'PTFE o il PEEK, utilizzando alcune semplici tecniche. Ecco due metodi efficaci per realizzare un collegamento sicuro.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3f247a elementor-widget elementor-widget-heading\" data-id=\"c3f247a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Utilizzo di una custodia morbida per tube</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0b4ab71 elementor-widget elementor-widget-text-editor\" data-id=\"0b4ab71\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Un approccio semplice consiste nell'utilizzare un manicotto corto di flessibile tubo  come elemento intermedio tra il tubo rigido e il ChipShop chip. Per procedere:</p><ul><li>Tagliare un pezzo di tube a pareti morbide lungo 2-3 cm. </li><li>Inserire un'estremità dell'tube , dotato di pareti morbide, sul connettore per patatine ChipShop.</li><li>Inserire l'tube rigido nell'altra estremità dell'tube a pareti morbide. Assicurarsi che l'accoppiamento sia saldo, senza lasciare spazi vuoti che potrebbero causare perdite.</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59c1c53 elementor-widget elementor-widget-text-editor\" data-id=\"59c1c53\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>💡 <strong>Suggerimento</strong>: assicurati che il manicotto abbia un diametro interno (ID) compreso tra 0,5 mm e 1 mm, in modo da adattarsi perfettamente al connettore Luer o “ mini Luer ” di ChipShop. Inoltre, il diametro interno (ID) del manicotto deve essere inferiore al diametro esterno (OD) del tubo rigido “ tube ” per garantire una tenuta salda.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-6d758ed elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6d758ed\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-d0b34a6\" data-id=\"d0b34a6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ed614ca elementor-widget elementor-widget-image\" data-id=\"ed614ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"240\" height=\"146\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Application_note_-_work_with_mini_Luer_1_medium-1.webp\" class=\"attachment-large size-large wp-image-14552\" alt=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-7b87d48\" data-id=\"7b87d48\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5834639 elementor-widget elementor-widget-image\" data-id=\"5834639\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"240\" height=\"147\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Application_note_-_work_with_mini_Luer_2_medium-1.webp\" class=\"attachment-large size-large wp-image-14553\" alt=\"\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<div class=\"elementor-element elementor-element-830543b elementor-widget elementor-widget-heading\" data-id=\"830543b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Utilizzo degli adattatori</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8d9ba15 elementor-widget elementor-widget-text-editor\" data-id=\"8d9ba15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Per un collegamento più solido e preciso, è possibile utilizzare degli adattatori per collegare un cavo rigido tube al chip ChipShop.</p><ul><li>Tagliare il tubo rigido “ tube  ” (ad esempio, in questo caso, <a href=\"https://darwin-microfluidics.com/it/prodotti/tubing-ptfe-1-16-od-per-microfluidica\">1/16″ di diametro esterno PTFE</a>) in linea retta utilizzando una fresa tube per ottenere un bordo pulito.</li><li>Fissare il raccordo \" tube \" a un <a href=\"https://darwin-microfluidics.com/it/prodotti/microfluidic-flangeless-fittings-1-4-28-to-1-16-od-tubing\">raccordo e</a> a <a href=\"https://darwin-microfluidics.com/it/prodotti/microfluidic-flangeless-fittings-1-4-28-to-1-16-od-tubing\" data-wg-splitted>una ghiera</a>. Assicurarsi che non vi sia alcun eccesso di \" tube \" che sporga oltre la ghiera, per garantire una tenuta ottimale.</li><li>Collegare il raccordo a un <a href=\"https://darwin-microfluidics.com/it/prodotti/male-luer-to-female-1-4-28-peek-adapter-pack-of-5?variant=14521392234541\">adattatore da 1/4″-28 femmina a Luer</a>.</li><li><strong>Per i connettori Luer</strong>: collegare l'adattatore direttamente al chip.</li><li><strong>Per le porte “ mini Luer </strong> ”: utilizzare un adattatore da mini Luer a Luer prima di collegare il gruppo al chip.</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-79a22a6 elementor-widget elementor-widget-text-editor\" data-id=\"79a22a6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>💡 <strong>Suggerimento</strong>: le porte \" Mini Luer \" sono più piccole rispetto alle porte Luer standard, quindi gli adattatori potrebbero occupare spazio aggiuntivo. Di conseguenza, potrebbe non essere possibile utilizzare contemporaneamente tutte le porte del chip. Pianifica il tuo esperimento di conseguenza per assicurarti di poterlo comunque eseguire in modo efficace utilizzando un numero inferiore di porte.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<section class=\"elementor-section elementor-inner-section elementor-element elementor-element-0a6dfd2 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0a6dfd2\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-1cfe48e\" data-id=\"1cfe48e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ea90c9d elementor-widget elementor-widget-image\" data-id=\"ea90c9d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"225\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/fitting-FEP-tubing-PTFE-1-300x225.webp\" class=\"attachment-medium size-medium wp-image-14558\" alt=\"Fotografia di un raccordo 1/4-28 e di un PTFE tube\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/fitting-FEP-tubing-PTFE-1-300x225.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/fitting-FEP-tubing-PTFE-1.webp 480w\" sizes=\"(max-width: 300px) 100vw, 300px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-inner-column elementor-element elementor-element-aaf8483\" data-id=\"aaf8483\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6e8021b elementor-widget elementor-widget-image\" data-id=\"6e8021b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"225\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Female-1-4-28-to-Luer-Adapter-1-300x225.webp\" class=\"attachment-medium size-medium wp-image-14559\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Female-1-4-28-to-Luer-Adapter-1-300x225.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Female-1-4-28-to-Luer-Adapter-1.webp 480w\" sizes=\"(max-width: 300px) 100vw, 300px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<div class=\"elementor-element elementor-element-3130ebe elementor-widget elementor-widget-image\" data-id=\"3130ebe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"225\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photograph-of-a-chipshop-connected-to-a-tubing-by-different-fittings-1-300x225.webp\" class=\"attachment-medium size-medium wp-image-14564\" alt=\"fotografia di una friggitoria collegata a un tubo tramite diversi raccordi\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photograph-of-a-chipshop-connected-to-a-tubing-by-different-fittings-1-300x225.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/photograph-of-a-chipshop-connected-to-a-tubing-by-different-fittings-1.webp 480w\" sizes=\"(max-width: 300px) 100vw, 300px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-dc81623 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"dc81623\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-763ff02\" data-id=\"763ff02\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-970dab2 elementor-widget elementor-widget-heading\" data-id=\"970dab2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusione</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-925830b elementor-widget elementor-widget-text-editor\" data-id=\"925830b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Il collegamento di un cavo \" tube \" ai chip microfluidici ChipShop può sembrare complesso, ma con l'approccio e gli strumenti giusti diventa un'operazione semplice. Sia che si utilizzino i chip a pareti morbide tube per la loro flessibilità, sia che si opti per quelli rigidi tube per la loro resistenza e precisione, conoscere le tecniche corrette garantisce connessioni sicure e affidabili.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ff90831 elementor-widget elementor-widget-text-editor\" data-id=\"ff90831\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"color: var( --e-global-color-text ); font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1rem; letter-spacing: -0.01rem;\">Restate sintonizzati per ulteriori consigli e approfondimenti su come ottimizzare i vostri sistemi microfluidici e far progredire la vostra ricerca</span><span style=\"font-weight: 400;\"> 🔬. Nel frattempo, ricordate: se <em>l’tube e è ben serrata, il flusso è perfetto!</em></span></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a3445bf elementor-widget elementor-widget-text-editor\" data-id=\"a3445bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">📧 Se avete domande o feedback, non esitate a contattarci all'indirizzo </span><a href=\"https://darwin-microfluidics.com/it/pages/contattaci\"><span style=\"font-weight: 400;\">contact@darwin-microfluidics.com</span></a><span style=\"font-weight: 400;\">.</span></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-73162c0 elementor-widget elementor-widget-global elementor-global-18316 elementor-widget-pix-promo-box\" data-id=\"73162c0\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta1\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Tubing_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"CERCHI FLESSIBILITÀ NELLE OPZIONI DEI tube?\"><a href=\"https://darwin-microfluidics.com/it/collections/tubi-microfluidici\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Scoprite la nostra selezione!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">CERCHI FLESSIBILITÀ NELLE OPZIONI DEI tube?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Esplorate le nostre soluzioni di tube microfluidici per garantire flussi affidabili ed efficienti nei vostri esperimenti!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>ChipShop microfluidic chips are compatible with soft-walled tubing, like silicone or Tygon commonly used with peristaltic pumps and syringe pumps due to their flexibility and ease of handling. However, a common challenge often arises when connecting these chips to rigid…</p>\n","protected":false},"author":3,"featured_media":14218,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[28,33],"tags":[],"class_list":["post-14543","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-connectors-tubing","category-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Come collegare l'tubo a un ChipShop Microfluidic Chip?</title>\n<meta name=\"description\" content=\"Uno dei problemi di questi chip microfluidici è la mancanza di un collegamento diretto con un sistema rigido tube. Vedremo come risolvere questo problema.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Come collegare l'tubo a un ChipShop Microfluidic Chip?\">\n<meta property=\"og:description\" content=\"Uno dei problemi di questi chip microfluidici è la mancanza di un collegamento diretto con un sistema rigido tube. Vedremo come risolvere questo problema.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-23T12:01:12+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:13:14+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/ChipShop_droplet_generator-removebg-preview-1.png\">\n\t<meta property=\"og:image:width\" content=\"587\">\n\t<meta property=\"og:image:height\" content=\"425\">\n\t<meta property=\"og:image:type\" content=\"image/png\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"5 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"How to Connect your Tubing to a ChipShop Microfluidic Chip?\",\"datePublished\":\"2023-02-23T12:01:12+00:00\",\"dateModified\":\"2026-11-19T14:13:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/\"},\"wordCount\":708,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/ChipShop_droplet_generator-removebg-preview-1.png\",\"articleSection\":[\"Connectors &amp; tubing\",\"Guides &amp; tutorials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/\",\"url\":\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/\",\"name\":\"How to Connect your Tubing to a ChipShop Microfluidic Chip?\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/ChipShop_droplet_generator-removebg-preview-1.png\",\"datePublished\":\"2023-02-23T12:01:12+00:00\",\"dateModified\":\"2026-11-19T14:13:14+00:00\",\"description\":\"Uno dei problemi di questi chip microfluidici è la mancanza di un collegamento diretto con un sistema rigido tube. Vedremo come risolvere questo problema.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/ChipShop_droplet_generator-removebg-preview-1.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/ChipShop_droplet_generator-removebg-preview-1.png\",\"width\":587,\"height\":425,\"caption\":\"photograph of a ChipShop droplet generator without background\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Connect your Tubing to a ChipShop Microfluidic Chip?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Il nostro blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/it\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Connect your Tubing to a ChipShop Microfluidic Chip?","description":"Uno dei problemi di questi chip microfluidici è la mancanza di un collegamento diretto con un sistema rigido tube. Vedremo come risolvere questo problema.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/","og_locale":"en_US","og_type":"article","og_title":"How to Connect your Tubing to a ChipShop Microfluidic Chip?","og_description":"An issue with these microfluidic chips is the lack of straightforward connection to rigid tubing. We will see solution to solve it.","og_url":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-23T12:01:12+00:00","article_modified_time":"2026-11-19T14:13:14+00:00","og_image":[{"width":587,"height":425,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/ChipShop_droplet_generator-removebg-preview-1.png","type":"image/png"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"5 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"How to Connect your Tubing to a ChipShop Microfluidic Chip?","datePublished":"2023-02-23T12:01:12+00:00","dateModified":"2026-11-19T14:13:14+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/"},"wordCount":708,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/ChipShop_droplet_generator-removebg-preview-1.png","articleSection":["Connectors &amp; tubing","Guides &amp; tutorials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/","url":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/","name":"How to Connect your Tubing to a ChipShop Microfluidic Chip?","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/ChipShop_droplet_generator-removebg-preview-1.png","datePublished":"2023-02-23T12:01:12+00:00","dateModified":"2026-11-19T14:13:14+00:00","description":"Uno dei problemi di questi chip microfluidici è la mancanza di un collegamento diretto con un sistema rigido tube. Vedremo come risolvere questo problema.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/ChipShop_droplet_generator-removebg-preview-1.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/ChipShop_droplet_generator-removebg-preview-1.png","width":587,"height":425,"caption":"photograph of a ChipShop droplet generator without background"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/how-to-connect-a-chipshop-microfluidic-chip-to-your-tubing/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"How to Connect your Tubing to a ChipShop Microfluidic Chip?"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Il nostro blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/ChipShop_droplet_generator-removebg-preview-1.png","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14543","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14543"}],"version-history":[{"count":61,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14543/revisions"}],"predecessor-version":[{"id":30780,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14543/revisions/30780"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14218"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14543"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14543"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14543"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}