{"id":13914,"date":"2023-02-07T12:30:38","date_gmt":"2023-02-07T11:30:38","guid":{"rendered":"http:\/\/eqgkrdm.cluster031.hosting.ovh.net\/?p=13914"},"modified":"2026-11-19T15:11:50","modified_gmt":"2026-11-19T14:11:50","slug":"bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/","title":{"rendered":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"13914\" class=\"elementor elementor-13914\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5c6a384b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5c6a384b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-185bb4a0\" data-id=\"185bb4a0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3cf1d3fe elementor-widget elementor-widget-text-editor\" data-id=\"3cf1d3fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><\/p>\n<p class=\"wp-block-paragraph\">In this application note, we compare the flow accuracy and stability at low flow rates of two micropump drivers designed by Bartels Mikrotechnik GmbH: the&nbsp;<strong>mp-Lowdriver<\/strong>&nbsp;and&nbsp;<strong>mp-Highdriver<\/strong>. Mounted on the mp-Multiboard (main control board) and connected to a Bartels micropump, these pump drivers offer various ways of tuning the electrical signal applied to the&nbsp;pump.<\/p>\n<p><\/p>\n<p><\/p>\n<p class=\"wp-block-paragraph\"><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ea19279 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ea19279\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c3328f8\" data-id=\"c3328f8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ebdeb61 elementor-widget elementor-widget-video\" data-id=\"ebdeb61\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings='{\"youtube_url\":\"https:\\\/\\\/youtu.be\\\/47NXqs9URzs\",\"lazy_load\":\"yes\",\"video_type\":\"youtube\",\"controls\":\"yes\"}' data-widget_type=\"video.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-wrapper elementor-open-inline\">\n\t\t\t<div class=\"elementor-video\"><\/div>\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-772b504 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"772b504\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-21c5604\" data-id=\"21c5604\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-250da34 elementor-widget elementor-widget-text-editor\" data-id=\"250da34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"text-align: center;\"><em><strong>Introduction to Bartels environment: t<\/strong><\/em><em><strong>he mp-Lowdriver and mp-Highdriver can be interfaced easily on the mp-Multiboard.<\/strong><\/em><\/p>\n<p>The mp-Multiboard is a complete interface with an Arduino microcontroller, which allows to connect and control mp6 micropumps, active valves, Sensirion SLF3S flow sensors and pressure sensors from the same software.<\/p>\n<p>The Bartels micropumps are based on a piezo technology, and the input electrical signal&nbsp;has an impact on the performances of the pump.&nbsp;Therefore, 3 pump drivers have been developed: the mp-Lowdriver, the mp-Highdriver and the mp-Highdriver4. Unlike the mp-Lowdriver and the mp-Highdriver, the mp-Highdriver4 allows to control 4 pumps at the same time, while the other two allow to control only one pump at a time. We will focus on the mp-Lowdriver and mp-Highdriver, as the mp-Highdriver4 has the sames specifications than the mp-Highdriver.<\/p>\n<h2 style=\"margin: 0px 0px 1em; line-height: 1.4; color: #000000; font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; letter-spacing: normal;\">Bartels Multiboard App: a unified user interface<\/h2>\n<p style=\"margin-right: 0px; margin-bottom: 1em; margin-left: 0px; line-height: 1.4; color: #000000; font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; font-size: 15px; letter-spacing: normal;\">Based on an Arduino framework, Bartels has developed an application to easily control&nbsp;any device connected to the mp-Multiboard. It allows you to vary the frequency and amplitude for each of the 4 pumps, close or open the 2 valves and, monitor the flow rate or pressure in real time.<\/p>\n<p style=\"margin-right: 0px; margin-bottom: 1em; margin-left: 0px; line-height: 1.4; color: #000000; font-family: 'Helvetica Neue', Helvetica, Arial, sans-serif; font-size: 15px; letter-spacing: normal;\">In addition to this, it is possible to control the activation time of each of the pumps but also to determine which one should be switched off first.&nbsp;This app makes it&nbsp;easy to create small multi-step programs without any line of code!<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9191814 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9191814\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-b8f9162\" data-id=\"b8f9162\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-63470c1 elementor-widget elementor-widget-image\" data-id=\"63470c1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"632\" height=\"748\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Bartels_multiboard_application_1-1.webp\" class=\"attachment-large size-large wp-image-13920\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Bartels_multiboard_application_1-1.webp 632w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Bartels_multiboard_application_1-1-253x300.webp 253w\" sizes=\"(max-width: 632px) 100vw, 632px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-05a5e23\" data-id=\"05a5e23\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a24d0f1 elementor-widget elementor-widget-image\" data-id=\"a24d0f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"628\" height=\"728\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Bartels_multiboard_application_2-1.webp\" class=\"attachment-large size-large wp-image-13921\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Bartels_multiboard_application_2-1.webp 628w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Bartels_multiboard_application_2-1-259x300.webp 259w\" sizes=\"(max-width: 628px) 100vw, 628px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-33 elementor-top-column elementor-element elementor-element-d954ddf\" data-id=\"d954ddf\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6917be0 elementor-widget elementor-widget-image\" data-id=\"6917be0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"634\" height=\"712\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Bartels_multiboard_application_3-1.webp\" class=\"attachment-large size-large wp-image-13922\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Bartels_multiboard_application_3-1.webp 634w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Bartels_multiboard_application_3-1-267x300.webp 267w\" sizes=\"(max-width: 634px) 100vw, 634px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b9b142d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b9b142d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1e17ae7\" data-id=\"1e17ae7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ca68ca0 elementor-widget elementor-widget-text-editor\" data-id=\"ca68ca0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>mp-Lowdriver vs mp-Highdriver: which driver should you choose?<\/h2>\n<p>The mp-Lowdriver and mp-Highdriver micropump drivers were designed to meet the needs of researchers working between 5 &micro;l\/min and 10 ml\/min. In microfluidics, flow rates under 100 &micro;l\/min are commonly used, and Bartels micropumps present a cost-effective alternative to current technologies. Comparing both pump drivers will help to choose the right driver for your application, but also to demonstrate the accuracy these micropumps and drivers can deliver.<\/p>\n<p>Table 1: Comparison between the mp-Lowdriver and mp-Highdriver micropump drivers (Bartels Mikrotechnik GmbH).<\/p>\n<table width=\"100%\">\n<tbody>\n<tr>\n<td>&nbsp;<\/td>\n<td><strong>mp-Lowdriver<\/strong><\/td>\n<td><strong>mp-Highdriver<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Dimensions<\/strong><\/td>\n<td>10.16 x 25.4 x 2.64 mm<\/td>\n<td>10.16 x 25.40 x 2.82 mm<\/td>\n<\/tr>\n<tr>\n<td><strong>Amplitude<\/strong><\/td>\n<td>0 to 150 Vpp<\/td>\n<td>10 to 150 Vpp<\/td>\n<\/tr>\n<tr>\n<td><strong>Frequency<\/strong><\/td>\n<td>8 to 2000 Hz<\/td>\n<td>50 to 800 Hz<\/td>\n<\/tr>\n<tr>\n<td><strong>Signal form<\/strong><\/td>\n<td>sine, custom<\/td>\n<td>sine, rectangular, custom<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em><strong>Table 1: Comparison between the mp-Lowdriver and mp-Highdriver micropump drivers (Bartels Mikrotechnik GmbH).<\/strong><\/em><\/p>\n<p>The following flow measurements were made with a Sensirion SLF3S-0600F thermal flow sensor (+\/- 5% accuracy on a range of +\/- 2000 &micro;l\/min, min. accuracy of 0.5 &micro;l\/min), also used in the Bartels mpSmart-Lowdosing system.<\/p>\n<h3>mp-Lowdriver flow measurements<\/h3>\n<p>Two&nbsp;measurements&nbsp;at 5 and 10 &micro;l\/min were carried out with the mp-Lowdriver during a few seconds. These measurements allowed us to test the capabilities of the mp-Lowdriver at very low flow rates.&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td><em>mp-Lowdriver<\/em><\/td>\n<td><strong>5 &micro;l\/min<\/strong><\/td>\n<td><strong>10 &micro;l\/min<\/strong><\/td>\n<\/tr>\n<tr>\n<td><strong>Measured value (&micro;l\/min)<\/strong><\/td>\n<td>5.22<\/td>\n<td>10.86<\/td>\n<\/tr>\n<tr>\n<td><strong>Standard error<\/strong><\/td>\n<td>0.57<\/td>\n<td>0.46<\/td>\n<\/tr>\n<tr>\n<td><strong>Standard error (%)<\/strong><\/td>\n<td>10.89<\/td>\n<td>4.23<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em><strong>Table 2: Comparison between the target and measured values at 5 and 10 &micro;l\/min with a mp6-liq, mp-Multiboard and mp-Lowdriver (Bartels Mikrotechnik). Measured with a SLF3S-0600F (Sensirion) thermal flow sensor.<\/strong><\/em><\/p>\n<p>&nbsp;<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-fa36fdf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"fa36fdf\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-7856e43\" data-id=\"7856e43\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-f6744f2 elementor-widget elementor-widget-image\" data-id=\"f6744f2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"456\" height=\"274\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/5_ulmin_Lowdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13929\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/5_ulmin_Lowdriver_mesure.webp 456w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/5_ulmin_Lowdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 456px) 100vw, 456px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-7baaed1\" data-id=\"7baaed1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4db9992 elementor-widget elementor-widget-image\" data-id=\"4db9992\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"464\" height=\"279\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/10_ulmin_Lowdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13930\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/10_ulmin_Lowdriver_mesure.webp 464w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/10_ulmin_Lowdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 464px) 100vw, 464px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-748d87f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"748d87f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c028350\" data-id=\"c028350\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-bc8e33c elementor-widget elementor-widget-text-editor\" data-id=\"bc8e33c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong><em>Figure 2: Actual flow rates with a mp6-liq micropump and mp-Lowdriver (Bartels Mikrotechnik) for target flow rates of 5 and 10 &micro;l\/min. Measured with a SLF3S-0600F flow sensor (Sensirion)<\/em><\/strong><\/p>\n<p>Bartels micropumps are indicated for flow rates higher than 5 &micro;l\/min. Though the mp-Lowdriver can go lower, the SLF3S-0600F flow sensor has a minimal accuracy of +\/- 5% or 0.5 &micro;l\/min, which is only relevant for flow rates higher than 5 &micro;l\/min. The measurements realized at 5 and 10 &micro;l\/min show that the accuracy of the flow sensor is the limitation to accurately measure the output flow rates, but the flow accuracy is low enough to address most applications in microfluidics.<\/p>\n<p>In order to better test the capabilities of the mp-Lowdriver, we have extended the measurement range beyond 10 &micro;l\/min to 50 &micro;l\/min. The results are shown below.<\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<p><em>mp-Lowdriver<\/em><\/p>\n<\/td>\n<td>\n<p><strong>20 &micro;l\/min<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>30 &micro;l\/min<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>40 &micro;l\/min<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>50 &micro;l\/min<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Measured value (&micro;l\/min)<\/strong><\/p>\n<\/td>\n<td>\n<p>21.04<\/p>\n<\/td>\n<td>\n<p>30.57<\/p>\n<\/td>\n<td>\n<p>39.99<\/p>\n<\/td>\n<td>\n<p>51.21<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Standard error<\/strong><\/p>\n<\/td>\n<td>\n<p>0.53<\/p>\n<\/td>\n<td>\n<p>1.30<\/p>\n<\/td>\n<td>\n<p>1.47<\/p>\n<\/td>\n<td>\n<p>0.89<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Standard error (%)<\/strong><\/p>\n<\/td>\n<td>\n<p>2.51<\/p>\n<\/td>\n<td>\n<p>4.24<\/p>\n<\/td>\n<td>\n<p>3.68<\/p>\n<\/td>\n<td>\n<p>1.74<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em><strong> Table 3: Comparison between the target and measured values at 20, 30, 40 and 50 &micro;l\/min with a mp6-liq, mp-Multiboard and mp-Lowdriver (Bartels Mikrotechnik). Measured with a SLF3S-0600F (Sensirion) thermal flow sensor.<\/strong><\/em><\/p>\n<p>&nbsp;<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-0dfb1ca elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"0dfb1ca\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-76ade63\" data-id=\"76ade63\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d752c0b elementor-widget elementor-widget-image\" data-id=\"d752c0b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"385\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/20_ulmin_Lowdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13931\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/20_ulmin_Lowdriver_mesure.webp 752w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/20_ulmin_Lowdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-8c61b9f\" data-id=\"8c61b9f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-37bf30d elementor-widget elementor-widget-image\" data-id=\"37bf30d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"385\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/30_ulmin_Lowdriver_measure.webp\" class=\"attachment-large size-large wp-image-13932\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/30_ulmin_Lowdriver_measure.webp 752w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/30_ulmin_Lowdriver_measure-300x180.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-522bdf6 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"522bdf6\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-87c9887\" data-id=\"87c9887\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6f53318 elementor-widget elementor-widget-image\" data-id=\"6f53318\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"385\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/40_ulmin_Lowdriver_measure.webp\" class=\"attachment-large size-large wp-image-13933\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/40_ulmin_Lowdriver_measure.webp 752w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/40_ulmin_Lowdriver_measure-300x180.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-3ffa527\" data-id=\"3ffa527\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ec94af1 elementor-widget elementor-widget-image\" data-id=\"ec94af1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"385\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/50_ulmin_Lowdriver_measure.webp\" class=\"attachment-large size-large wp-image-13934\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/50_ulmin_Lowdriver_measure.webp 752w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/50_ulmin_Lowdriver_measure-300x180.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-109de36 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"109de36\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4e33c9c\" data-id=\"4e33c9c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6ed9bb3 elementor-widget elementor-widget-text-editor\" data-id=\"6ed9bb3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em><strong>Figure 3: Actual flow rates with a mp6-liq micropump and mp-Lowdriver (Bartels Mikrotechnik) for target flow rates of 20, 30, 40 and 50 &micro;l\/min. Measured with a SLF3S-0600F flow sensor (Sensirion)<\/strong><\/em><\/p>\n<p>These results show that the mp-Lowdriver is very suitable for flow rates between 20 and 50 &micro;l\/min. Indeed, the error, in all cases, is less than 5% (flow sensor limit).<\/p>\n<p>We can therefore conclude that the mp-Lowdriver can be used for applications requiring flow rates higher than 5 &micro;l\/min. Further tests should be done to address flow rates lower than 5 &micro;l\/min, using more accurate flow sensors.<\/p>\n<h3>mp-Highdriver flow measurements<\/h3>\n<p>We performed 4 measurements (50, 200, 500 and 850 &micro;l\/min) during a few seconds to test the capabilities of the mp-Highdriver for higher flow rates. The results are shown below.<\/p>\n<table>\n<tbody>\n<tr>\n<td>\n<p><em>mp-Highdriver<\/em><\/p>\n<\/td>\n<td>\n<p><strong>50 &micro;l\/min<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>200 &micro;l\/min<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>500 &micro;l\/min<\/strong><\/p>\n<\/td>\n<td>\n<p><strong>850 &micro;l\/min<\/strong><\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Measured value (&micro;l\/min)<\/strong><\/p>\n<\/td>\n<td>\n<p>51.62<\/p>\n<\/td>\n<td>\n<p>202.86<\/p>\n<\/td>\n<td>\n<p>498.09<\/p>\n<\/td>\n<td>\n<p>849.35<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Standard error<\/strong><\/p>\n<\/td>\n<td>\n<p>0.96<\/p>\n<\/td>\n<td>\n<p>1.05<\/p>\n<\/td>\n<td>\n<p>1.86<\/p>\n<\/td>\n<td>\n<p>2.79<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p><strong>Standard error (%)<\/strong><\/p>\n<\/td>\n<td>\n<p>1.86<\/p>\n<\/td>\n<td>\n<p>0.51<\/p>\n<\/td>\n<td>\n<p>0.37<\/p>\n<\/td>\n<td>\n<p>0.33<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p><em><strong> Table 4: Comparison between the target and measured values at 50, 200, 500 and 850 &micro;l\/min with a mp6-liq, mp-Multiboard and mp-Lowdriver (Bartels Mikrotechnik). Measured with a SLF3S-0600F (Sensirion) thermal flow sensor.<\/strong><\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-018e838 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"018e838\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-50c35f7\" data-id=\"50c35f7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8e1ae73 elementor-widget elementor-widget-image\" data-id=\"8e1ae73\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"458\" height=\"275\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/50_ulmin_highdriver_mesure_25bceb57-00f0-424d-ad95-d958746de7b5.webp\" class=\"attachment-large size-large wp-image-13935\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/50_ulmin_highdriver_mesure_25bceb57-00f0-424d-ad95-d958746de7b5.webp 458w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/50_ulmin_highdriver_mesure_25bceb57-00f0-424d-ad95-d958746de7b5-300x180.webp 300w\" sizes=\"(max-width: 458px) 100vw, 458px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-9db952d\" data-id=\"9db952d\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-23ed340 elementor-widget elementor-widget-image\" data-id=\"23ed340\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"459\" height=\"276\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/200_ulmin_highdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13936\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/200_ulmin_highdriver_mesure.webp 459w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/200_ulmin_highdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 459px) 100vw, 459px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f2951a3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f2951a3\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-79c8410\" data-id=\"79c8410\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-3bb05dd elementor-widget elementor-widget-image\" data-id=\"3bb05dd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"464\" height=\"279\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/500_ulmin_highdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13937\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/500_ulmin_highdriver_mesure.webp 464w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/500_ulmin_highdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 464px) 100vw, 464px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-06d04cf\" data-id=\"06d04cf\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7a1d3d4 elementor-widget elementor-widget-image\" data-id=\"7a1d3d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"461\" height=\"277\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/850_ulmin_highdriver_mesure.webp\" class=\"attachment-large size-large wp-image-13938\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/850_ulmin_highdriver_mesure.webp 461w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/850_ulmin_highdriver_mesure-300x180.webp 300w\" sizes=\"(max-width: 461px) 100vw, 461px\"\/>\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-40442b0 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"40442b0\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b1f4bbc\" data-id=\"b1f4bbc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-4168d1d elementor-widget elementor-widget-text-editor\" data-id=\"4168d1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em><b>Figure 2: Actual flow rates with a mp6-liq micropump and mp-Highdriver (Bartels Mikrotechnik) for target flow rates of 50, 200, 500 and 850 &micro;l\/min. Measured with a SLF3S-0600F flow sensor (Sensirion).<br><\/b><\/em><\/p>\n<p>The results for the mp-Highdriver are very satisfactory for the range tested. Indeed, the error, whatever the flow rate tested, is much lower than 2% (below the accuracy limit of the flow sensor) which reveals a very good stability of the device.<\/p>\n<p>When discussing the target value of 50 &micro;l\/min measured with both mp-Lowdriver and mp-Highdriver, the results indicate very similar measured values. For this flow rate, the user has a choice between the mp-Lowdriver and the mp-Highdriver.<\/p>\n<h3>Conclusion<\/h3>\n<p>Bartels Mikrotechnik have created a powerful and easy-to-use environment to control and monitor fluids over a wide range of applications, from millifluidics to microfluidics. Coupled with the mp-Multiboard and a micropump, both mp-Lowdriver and mp-Highdriver offer efficient ways of driving fluids in a microfluidic system, with a good price\/accuracy ratio.<\/p>\n<p>Darwin Microfluidics is a worldwide distributor of Bartels products. Find all the components to create your microfluidic setup <a href=\"https:\/\/darwin-microfluidics.com\/collections\/bartels\"><strong><span style=\"color: #0000ff;\">here<\/span><\/strong><\/a>!<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>In this application note, we compare the flow accuracy and stability at low flow rates of two micropump drivers designed by Bartels Mikrotechnik GmbH: the&nbsp;mp-Lowdriver&nbsp;and&nbsp;mp-Highdriver. Mounted on the mp-Multiboard (main control board) and connected to a Bartels micropump, these pump&hellip;<\/p>\n","protected":false},"author":3,"featured_media":14796,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[29,24],"tags":[],"class_list":["post-13914","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-application-notes","category-flow-control"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates - Darwin Microfluidics<\/title>\n<meta name=\"description\" content=\"In this review, we compare the flow accuracy and stability at low flow rates of two micropump drivers designed by Bartels Mikrotechnik GmbH.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates - Darwin Microfluidics\" \/>\n<meta property=\"og:description\" content=\"In this review, we compare the flow accuracy and stability at low flow rates of two micropump drivers designed by Bartels Mikrotechnik GmbH.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2023-02-07T11:30:38+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:11:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/mp-Highdriver4-Pump-Driver_2048x2048-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1000\" \/>\n\t<meta property=\"og:image:height\" content=\"1000\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Colin Marquet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates\",\"datePublished\":\"2023-02-07T11:30:38+00:00\",\"dateModified\":\"2026-11-19T14:11:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/\"},\"wordCount\":1084,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/mp-Highdriver4-Pump-Driver_2048x2048-1.webp\",\"articleSection\":[\"Application notes\",\"Flow control\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/\",\"name\":\"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/mp-Highdriver4-Pump-Driver_2048x2048-1.webp\",\"datePublished\":\"2023-02-07T11:30:38+00:00\",\"dateModified\":\"2026-11-19T14:11:50+00:00\",\"description\":\"In this review, we compare the flow accuracy and stability at low flow rates of two micropump drivers designed by Bartels Mikrotechnik GmbH.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/mp-Highdriver4-Pump-Driver_2048x2048-1.webp\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/mp-Highdriver4-Pump-Driver_2048x2048-1.webp\",\"width\":1000,\"height\":1000,\"caption\":\"Photograph of a Bartels Highdriver4. White Backkground\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/colinmarquet\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates - Darwin Microfluidics","description":"In this review, we compare the flow accuracy and stability at low flow rates of two micropump drivers designed by Bartels Mikrotechnik GmbH.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/","og_locale":"en_US","og_type":"article","og_title":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates - Darwin Microfluidics","og_description":"In this review, we compare the flow accuracy and stability at low flow rates of two micropump drivers designed by Bartels Mikrotechnik GmbH.","og_url":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-07T11:30:38+00:00","article_modified_time":"2026-11-19T14:11:50+00:00","og_image":[{"width":1000,"height":1000,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","type":"image\/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/"},"author":{"name":"Colin Marquet","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677"},"headline":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates","datePublished":"2023-02-07T11:30:38+00:00","dateModified":"2026-11-19T14:11:50+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/"},"wordCount":1084,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","articleSection":["Application notes","Flow control"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/","url":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/","name":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates - Darwin Microfluidics","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","datePublished":"2023-02-07T11:30:38+00:00","dateModified":"2026-11-19T14:11:50+00:00","description":"In this review, we compare the flow accuracy and stability at low flow rates of two micropump drivers designed by Bartels Mikrotechnik GmbH.","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","width":1000,"height":1000,"caption":"Photograph of a Bartels Highdriver4. White Backkground"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/bartels-mp-lowdriver-mp-highdriver-comparison-for-low-flow-rates\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"Bartels mp-Lowdriver &amp; mp-Highdriver comparison for low flow rates"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/colinmarquet\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/mp-Highdriver4-Pump-Driver_2048x2048-1.webp","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/13914","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=13914"}],"version-history":[{"count":14,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/13914\/revisions"}],"predecessor-version":[{"id":15224,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/13914\/revisions\/15224"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/14796"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=13914"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=13914"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=13914"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}