{"id":13959,"date":"2023-02-08T14:21:04","date_gmt":"2023-02-08T13:21:04","guid":{"rendered":"http:\/\/eqgkrdm.cluster031.hosting.ovh.net\/?p=13959"},"modified":"2024-02-27T12:46:48","modified_gmt":"2024-02-27T11:46:48","slug":"lipid-nanoparticle-generation-in-microfluidics","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/","title":{"rendered":"Lipid Nanoparticle (LNP) generation in microfluidics"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"13959\" class=\"elementor elementor-13959\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3d81505 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3d81505\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ef5a6a3\" data-id=\"ef5a6a3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8b4b7ff elementor-widget elementor-widget-text-editor\" data-id=\"8b4b7ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Interest in<strong> Lipid Nanoparticle generation<\/strong>&nbsp;has been growing over the past decade. Indeed, these <b>Nanoliposomes <\/b>have many advantages, such as the possibility of combining different therapeutic substances, protecting the active ingredients against alterations, controlling the diffusion of substances in the body, or even the possibility of complete sterilization by filtration.<\/p><h2><strong>What is a Nanoliposome?<\/strong><\/h2><p><strong>Nanoliposomes or Lipid Nanoparticle<\/strong>&nbsp;are often composed of<strong> one or more lamellar layers<\/strong>. These layers include a phospholipid bilayer that contains a small volume of aqueous liquid. The diameter of nanoliposomes can vary from a few tens of nanometers to hundreds of micrometers depending on the method used to generate them.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b1fbf2d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b1fbf2d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-top-column elementor-element elementor-element-96e9a29\" data-id=\"96e9a29\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-e6c22e3\" data-id=\"e6c22e3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-bd0edc7 elementor-widget elementor-widget-image\" data-id=\"bd0edc7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"548\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Liposome_-_Darwin_Microfluidics-2.webp\" class=\"attachment-large size-large wp-image-13963\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Liposome_-_Darwin_Microfluidics-2.webp 818w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Liposome_-_Darwin_Microfluidics-2-300x257.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Liposome_-_Darwin_Microfluidics-2-768x657.webp 768w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1: Schematic representation of a liposome. The shell is a phospholipidic bilayer surrounding an aqueous core.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-top-column elementor-element elementor-element-fba2044\" data-id=\"fba2044\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4438248 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4438248\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-abe2e20\" data-id=\"abe2e20\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-944d4fe elementor-widget elementor-widget-text-editor\" data-id=\"944d4fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Phospholipids and lipids are the main components of liposomal membranes. They have the particularity of being soluble in various organic solvents and it is precisely for this property that most current methods use organic solvents to solubilize the lipids as the first step of the protocol.<\/p>\n<p>The rise of microfluidics opens a new door for the preparation of lipid-based <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a>. Microfluidic methods have demonstrated their ability to control the mixing process of the organic and aqueous phases, but also the size and thus obtain a high monodispersity as well as the possibility to play on the design of the microfluidic chip to vary the composition and size of the obtained nanoliposomes.<\/p>\n<h2 class=\"ql-align-center\">Advantages of using microfluidics to generate Nanoliposomes<\/h2>\n<p>The oldest and traditional methods for the preparation of <strong>liposomes<\/strong> consist of the so-called macroscale or<strong> batch techniques<\/strong> based on the initial dehydration of lipid films followed by the swelling process and the final mechanical manipulation to create the water-dispersed bilayers. However,<strong> poor reproducibility<\/strong>, <strong>limited<\/strong> process <strong>control<\/strong> and the <strong>inefficient use of materials and reagents<\/strong> characterize these methods.<\/p>\n<p>Microfluidics has been recently investigated as <strong>an efficient method<\/strong> for the preparation of liposomes in a controlled, reproducible and <strong>hight-throughput manner<\/strong>.<\/p>\n<p>Microfluidics allows a reduction of the used volumes and the associated costs by handling fluids in geometrically constrained compartments typically characterized by micrometer length scales and low Reynolds numbers.<\/p>\n<h2 style=\"font-family: var(--pix-heading-font), sans-serif; letter-spacing: -0.16px;\">What microfluidic devices to use for Nanoliposome preparation?<\/h2>\n<div><span style=\"letter-spacing: -0.16px;\">There are different methods to produce&nbsp;<\/span><span style=\"font-weight: bolder; letter-spacing: -0.16px;\">lipid <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a><\/span><span style=\"letter-spacing: -0.16px;\">&nbsp;in microfluidics. These different methods result in different geometries of microfluidic devices.<\/span><br style=\"letter-spacing: -0.16px;\"><span style=\"letter-spacing: -0.16px;\">Some chips may also have a specific treatment, which will influence the size or composition of the nanoliposomes. In this section, we will therefore look at the different geometries that exist and examples from the literature to assess the resulting applications.<\/span><\/div>\n<h3>Herringbone mixer for Lipid Nanoparticles production<\/h3>\n<p>Recently, micromixing through the<b> Herringbone method<\/b> has been investigated and shows<b> great advantages among the other preparation methods<\/b> in terms of liposome production efficiency.<\/p>\n<p>For example, PEGylated liposomes were successfully prepared by using a Herringbone Mixer . This device is a chaotic advection mixer able to disrupt the <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/laminar-flow-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">laminar flow<\/a> typical of microchannels, and reduce the time needed for the liposomes preparation process.<\/p>\n<p>The specific pattern of the device made of herringbone grooves redistributes the fluids by creating a transverse flow into the <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/microchannel-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">microchannel<\/a>. The vertices of the grooves are offset to approximately one third of the width of the channel and two counter-rotating vortices are created by the grooves. The subsequent set of herringbone groves with a mirrored orientation of the vortices allow the creation of a full mixing cycle as shown in the Fig.2.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5d68603 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5d68603\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-top-column elementor-element elementor-element-d010358\" data-id=\"d010358\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-d8c16d6\" data-id=\"d8c16d6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c57ec59 elementor-widget elementor-widget-image\" data-id=\"c57ec59\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"613\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Principle_of_microfluidic_mixing_in_herring_bone_channel_and_formation_of_liposomes.webp\" class=\"attachment-large size-large wp-image-13964\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Principle_of_microfluidic_mixing_in_herring_bone_channel_and_formation_of_liposomes.webp 666w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Principle_of_microfluidic_mixing_in_herring_bone_channel_and_formation_of_liposomes-300x287.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 2 : Principle of microfluidic mixing in herringbone channel and formation of liposomes. Organic water miscible solvent (ethanol) contains lipids forming liposomes while water phase contains water soluble components that are to be encapsulated. Extracted from Kotou&#269;ek et al. Sci. Reports 10:5595 (2020).<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-top-column elementor-element elementor-element-0660a25\" data-id=\"0660a25\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5d9e6d8 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5d9e6d8\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e8c007a\" data-id=\"e8c007a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-54c7184 elementor-widget elementor-widget-global elementor-global-18286 elementor-widget-pix-promo-box\" data-id=\"54c7184\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Imaging_1920x600_DARWIN_MICROFLUIDICS-2.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"READY TO REVOLUTIONIZE DRUG DELIVERY WITH LIPID NANOPARTICLES?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/products\/lipid-nanoparticle-synthesis-pack\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">READY TO REVOLUTIONIZE DRUG DELIVERY WITH LIPID NANOPARTICLES?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Optimize your research processes and achieve faster results with our innovative solutions!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a255f5a elementor-widget elementor-widget-text-editor\" data-id=\"a255f5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The alternation of these herringbone sets reorients the flow periodically and strongly improves the mixing. This microfluidic preparation method allows the controlled creation of liposomes of different sizes (&sim;100 nm) and good dispersity (&lt; 0.2). By changing the flow rate parameters and the formulations in terms of aqueous buffer, phospholipid concentrations and composition it is possible to finely tune the production of liposomes with the desired features.<\/p><p>To illustrate this design, the team of Leug et al. (2015) proposes a general method for encapsulating macromolecules (SiRNA) in a lipid nanoparticle system. They were able to generate <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> from <b>40 to 140 nm in diameter<\/b> using a herringbone micromixer.<br>There are many techniques, and therefore many geometries, that allow you to generate <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a>. The information presented here will help you choose your microfluidic device according to your applications and the size of the <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> you wish to generate.<\/p><h3 style=\"font-family: var(--pix-heading-font), sans-serif; letter-spacing: -0.16px;\">Droplet generator for Lipid Nanoparticles production<\/h3><div><strong>Microfluidic flow focusing<\/strong> is one of the first introduced methods and consists of the use of microfluidic chips with a <strong>cross-flow geometry<\/strong> to ensure the intersection of a central flow of an alcoholic solution containing the phospholipids with an aqueous solution.<\/div><div><p>Typically, three flows merge in the same microfluidic channel as showed in Fig.3. This is the typical pattern of microfluidic devices suitable for the <b>generation of droplets<\/b>. As you can see a phospholipid alcoholic solution is injected in a central channel flanked by two lateral aqueous solutions.&nbsp;<\/p><\/div><div><p>The lipid containing stream is focused, and thanks to:<\/p><ol><li>The<strong> low Reynolds number.<\/strong><\/li><li>The <strong>diffusion dominated by the mass transfer.<\/strong><\/li><\/ol><p>The alcohol diffuses into the aqueous solution and its concentration in the central stream starts to decrease. As it reaches a critical concentration below the solubility of the phospholipids, these ones spontaneously organise into liposomes in a self-assembly manner.<\/p><p>The volumetric flow rate ratio between the lipid and water phase streams, together with the total flow rate, influence the size of the obtained liposomes and their adjustment allows a controlled preparation.<\/p><\/div>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9e24a58 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9e24a58\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-top-column elementor-element elementor-element-d07f596\" data-id=\"d07f596\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-7ada25c\" data-id=\"7ada25c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e049c09 elementor-widget elementor-widget-image\" data-id=\"e049c09\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"386\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp\" class=\"attachment-large size-large wp-image-13968\" alt=\"Illustration of nucleation and growth mechanism of nanoprecipitation along the focus mixing channel in a hydrodynamic flow focusing\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp 680w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device-300x181.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 4 : Illustration of nucleation and growth mechanism of nanoprecipitation along the focus mixing channel. Extracted from Lababidi et al. Beilstein J. Nanotechnol. 2019.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-top-column elementor-element elementor-element-d1087f5\" data-id=\"d1087f5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ad49ee8 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ad49ee8\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-859a047\" data-id=\"859a047\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b11f666 elementor-widget elementor-widget-text-editor\" data-id=\"b11f666\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Finally, Karnik et al. showed in 2008 that it is possible to generate <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> by flow focusing in a highly monodisperse manner. Indeed, the team is able to produce <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> of 31 nm in diameter (&plusmn; 1 nm). Here, the size varies according to the composition of the <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a>.<\/p><h3>The Y-shaped microfluidic device for&nbsp; Lipid Nanoparticles production<\/h3><p>This design allows two fluids (usually an aqueous solution containing surfactant and a lipid solution coupled to a solvent) to be brought into contact with each other and then allow nanoprecipitation to occur in the collection channel. Nanoprecipitation is the aggregation of <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> in time and space.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d42d473 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d42d473\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-top-column elementor-element elementor-element-63f60b7\" data-id=\"63f60b7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-bed008e\" data-id=\"bed008e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5eadd0f elementor-widget elementor-widget-image\" data-id=\"5eadd0f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"334\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Principle_of_nanoparticle_formation_with_a_Y-shaped_microfluidic_device.webp\" class=\"attachment-large size-large wp-image-13972\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Principle_of_nanoparticle_formation_with_a_Y-shaped_microfluidic_device.webp 836w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Principle_of_nanoparticle_formation_with_a_Y-shaped_microfluidic_device-300x156.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Principle_of_nanoparticle_formation_with_a_Y-shaped_microfluidic_device-768x401.webp 768w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 3 : Principle of nanoparticle formation with a Y-shaped microfluidic device. a) Extracted from Therriault et al. Nat. Mater. 2003 and b) modified from DeMello. Nature. 2006.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-top-column elementor-element elementor-element-9c069f0\" data-id=\"9c069f0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1a57c0b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1a57c0b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cb1ea49\" data-id=\"cb1ea49\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d0d9044 elementor-widget elementor-widget-text-editor\" data-id=\"d0d9044\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The Roces et al. team (2020) used a Y-shape micromixer to develop lipid <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a>. This device was used to generate <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> of 100 to 200 nm in diameter. The size of these <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> is considerably reduced after filtration, making it possible to obtain nanolipids between 50 and 80 nm with a polydispersity index of 0.2.<\/p><h3>The 3D coaxial capillary device for Lipid Nanoparticles production<\/h3><p>These devices offer the possibility of creating 3D coaxial flows, which are essential for rapid and uniform mass transfer. The co-current capillary microfluidic device consists of two capillaries. A tapered glass capillary was inserted into another larger cylindrical capillary with a coaxial alignment. The inner fluid (aqueous solution containing surfactant) flows inside the inner cylindrical capillary, while the outer fluid (a lipid solution coupled to a solvent) flows between the inner and outer cylindrical capillaries.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-caba8ee elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"caba8ee\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-top-column elementor-element elementor-element-e922003\" data-id=\"e922003\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-f805502\" data-id=\"f805502\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9a6ff6d elementor-widget elementor-widget-image\" data-id=\"9a6ff6d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"215\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_view_of_a_3D_glass_capillary_coflow_microfluidic_nanoprecipitation_platform_for_preparing_nanoparticles-1024x344.webp\" class=\"attachment-large size-large wp-image-13973\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_view_of_a_3D_glass_capillary_coflow_microfluidic_nanoprecipitation_platform_for_preparing_nanoparticles-1024x344.webp 1024w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_view_of_a_3D_glass_capillary_coflow_microfluidic_nanoprecipitation_platform_for_preparing_nanoparticles-300x101.webp 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_view_of_a_3D_glass_capillary_coflow_microfluidic_nanoprecipitation_platform_for_preparing_nanoparticles-768x258.webp 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Schematic_view_of_a_3D_glass_capillary_coflow_microfluidic_nanoprecipitation_platform_for_preparing_nanoparticles.webp 1195w\" sizes=\"(max-width: 640px) 100vw, 640px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 4 : Schematic view of a 3D glass capillary coflow microfluidic nanoprecipitation platform for preparing nanoparticles. Extracted from Liu et al. Adv. Mater. 2015.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-25 elementor-top-column elementor-element elementor-element-9ca2695\" data-id=\"9ca2695\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f9bebc3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f9bebc3\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-b87e550\" data-id=\"b87e550\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-2c70349 elementor-widget elementor-widget-text-editor\" data-id=\"2c70349\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>With this microfluidic device, Liu et al. published a paper in 2015 highlighting the generation of lipid <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> between 70 and 280 nm in diameter with a polydispersity index close to 0.1. This size evolves as a function of the number of Renolds due to the presence of capillaries.<\/p><h2>Final considerations<\/h2><p>There are many techniques, and therefore many geometries, that allow you to generate <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a>. The information presented here will help you choose your microfluidic device according to your applications and the size of the <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> you wish to generate.<\/p><p>Darwin Microfluidics is committed to this revolution.<strong> We provide innovative microfluidic devices<\/strong> for liposome preparation and our staff of experienced scientists and PhDs offer the support that researchers need to be successful in their activities.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5dd9d51 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5dd9d51\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2b914ab\" data-id=\"2b914ab\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8f6b73b elementor-widget elementor-widget-text-editor\" data-id=\"8f6b73b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>&#129504; What you have to remember<\/h3><ul><li>Liposomes or lipid <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> are enclosed vesicles widely used for the encapsulation of different kind of molecules such as DNA, proteins, drugs and\/or other chemicals.<\/li><li>Microfluidic methods offer an alternative way to prepare lipid <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/nanoparticles-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">nanoparticles<\/a> with improved control over size and composition.<\/li><li>Flow rate ratios between lipid and water phase streams, together with total flow rate, can be adjusted to obtain liposomes of desired size.<\/li><li>By adjusting parameters such as the flow rate and formulation components, it is possible to achieve precise control over the size (&lt;100 nm) and dispersity (&lt; 0.2) of the liposomes.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1526c41 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1526c41\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7bdbe5c\" data-id=\"7bdbe5c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Interest in Lipid Nanoparticle generation&nbsp;has been growing over the past decade. Indeed, these Nanoliposomes have many advantages, such as the possibility of combining different therapeutic substances, protecting the active ingredients against alterations, controlling the diffusion of substances in the body,&hellip;<\/p>\n","protected":false},"author":3,"featured_media":13968,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[26,21],"tags":[],"class_list":["post-13959","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-nanoparticles-lnp","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Lipid Nanoparticle (LNP) generation in microfluidics<\/title>\n<meta name=\"description\" content=\"Interest in generating lipid nanoparticles has increased over the past decade. Learn how to produce them using microfluidics.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Lipid Nanoparticle (LNP) generation in microfluidics\" \/>\n<meta property=\"og:description\" content=\"Interest in generating lipid nanoparticles has increased over the past decade. Learn how to produce them using microfluidics.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2023-02-08T13:21:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:46:48+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"680\" \/>\n\t<meta property=\"og:image:height\" content=\"410\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Colin Marquet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Lipid Nanoparticle (LNP) generation in microfluidics\",\"datePublished\":\"2023-02-08T13:21:04+00:00\",\"dateModified\":\"2024-02-27T11:46:48+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/\"},\"wordCount\":1478,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp\",\"articleSection\":[\"Nanoparticles &amp; LNP\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/\",\"name\":\"Lipid Nanoparticle (LNP) generation in microfluidics\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp\",\"datePublished\":\"2023-02-08T13:21:04+00:00\",\"dateModified\":\"2024-02-27T11:46:48+00:00\",\"description\":\"Interest in generating lipid nanoparticles has increased over the past decade. Learn how to produce them using microfluidics.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp\",\"width\":680,\"height\":410,\"caption\":\"Illustration of nucleation and growth mechanism of nanoprecipitation along the focus mixing channel in a hydrodynamic flow focusing\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/lipid-nanoparticle-generation-in-microfluidics\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Lipid Nanoparticle (LNP) generation in microfluidics\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/colinmarquet\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Lipid Nanoparticle (LNP) generation in microfluidics","description":"Interest in generating lipid nanoparticles has increased over the past decade. Learn how to produce them using microfluidics.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/","og_locale":"en_US","og_type":"article","og_title":"Lipid Nanoparticle (LNP) generation in microfluidics","og_description":"Interest in generating lipid nanoparticles has increased over the past decade. Learn how to produce them using microfluidics.","og_url":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-08T13:21:04+00:00","article_modified_time":"2024-02-27T11:46:48+00:00","og_image":[{"width":680,"height":410,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp","type":"image\/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/"},"author":{"name":"Colin Marquet","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677"},"headline":"Lipid Nanoparticle (LNP) generation in microfluidics","datePublished":"2023-02-08T13:21:04+00:00","dateModified":"2024-02-27T11:46:48+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/"},"wordCount":1478,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp","articleSection":["Nanoparticles &amp; LNP","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/","url":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/","name":"Lipid Nanoparticle (LNP) generation in microfluidics","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp","datePublished":"2023-02-08T13:21:04+00:00","dateModified":"2024-02-27T11:46:48+00:00","description":"Interest in generating lipid nanoparticles has increased over the past decade. Learn how to produce them using microfluidics.","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp","width":680,"height":410,"caption":"Illustration of nucleation and growth mechanism of nanoprecipitation along the focus mixing channel in a hydrodynamic flow focusing"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/lipid-nanoparticle-generation-in-microfluidics\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"Lipid Nanoparticle (LNP) generation in microfluidics"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/colinmarquet\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Illustration_of_nucleation_and_growth_mechanism_of_nanoprecipitation_along_the_focus_mixing_channel_in_a_hydrodynamic_flow_focusing_device.webp","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/13959","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=13959"}],"version-history":[{"count":44,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/13959\/revisions"}],"predecessor-version":[{"id":18519,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/13959\/revisions\/18519"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/13968"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=13959"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=13959"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=13959"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}