{"id":14138,"date":"2023-02-16T17:08:43","date_gmt":"2023-02-16T16:08:43","guid":{"rendered":"http:\/\/eqgkrdm.cluster031.hosting.ovh.net\/?p=14138"},"modified":"2026-11-19T15:12:22","modified_gmt":"2026-11-19T14:12:22","slug":"peristaltic-pumping-how-does-it-work","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/","title":{"rendered":"Peristaltic Pumping: How Does It Work?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14138\" class=\"elementor elementor-14138\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6dab4d5 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6dab4d5\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-171e059\" data-id=\"171e059\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-98e1276 elementor-widget elementor-widget-text-editor\" data-id=\"98e1276\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Functional principle of peristaltic pumps<\/h2><p>Peristaltic pumps are so-called roller pumps in which the rollers are rotated over a tube placed in the pump head, leading to the mechanical alteration of the form (squeezing) of the tube.<\/p><p>The restitution of the tube following the roller triggers the pumping of the medium in the interior of the tube so that only the pump tube comes into contact with the medium.<\/p><p>The flow rate is determined by the shape and the speed of the roller head, the number of rollers, and the inner diameter of the tube. Find our peristaltic pumps catalog <span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/darwin-microfluidics.com\/collections\/peristaltic-pumps\"><span style=\"text-decoration: underline;\"><strong>here<\/strong><\/span><\/a><\/span>!<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-95d0b77 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"95d0b77\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-f03ddee\" data-id=\"f03ddee\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7543f3a elementor-widget elementor-widget-image\" data-id=\"7543f3a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"480\" height=\"351\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_1_large-1.webp\" class=\"attachment-large size-large wp-image-14141\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_1_large-1.webp 480w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_1_large-1-300x219.webp 300w\" sizes=\"(max-width: 480px) 100vw, 480px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">  1. The tube is tensioned between the tubing bed and the rotor. Each roller compresses the tube<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-6512735\" data-id=\"6512735\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9afa83d elementor-widget elementor-widget-image\" data-id=\"9afa83d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"480\" height=\"346\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_2_large-1.webp\" class=\"attachment-large size-large wp-image-14142\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_2_large-1.webp 480w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_2_large-1-300x216.webp 300w\" sizes=\"(max-width: 480px) 100vw, 480px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">2. The rotor rollers move along the tube. The tube is squeezed continually through the rollers which displace the liquid in the direction of the roller head motion.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-eefc996 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"eefc996\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-5846f8e\" data-id=\"5846f8e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7113d89 elementor-widget elementor-widget-image\" data-id=\"7113d89\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"480\" height=\"338\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_3_large-1.webp\" class=\"attachment-large size-large wp-image-14145\" alt=\"Diagram of the operation of a peristaltic pump.\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_3_large-1.webp 480w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_3_large-1-300x211.webp 300w\" sizes=\"(max-width: 480px) 100vw, 480px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">3. The tube behind the roller resumes its original shape, creates a vacuum and suctions the liquid. <\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t<div class=\"elementor-column elementor-col-50 elementor-top-column elementor-element elementor-element-f487262\" data-id=\"f487262\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9fba785 elementor-widget elementor-widget-image\" data-id=\"9fba785\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"480\" height=\"346\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_4_large-1.webp\" class=\"attachment-large size-large wp-image-14146\" alt=\"Drawing of a Roller pump head\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_4_large-1.webp 480w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_4_large-1-300x216.webp 300w\" sizes=\"(max-width: 480px) 100vw, 480px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">4. The process begins anew.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4798201 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4798201\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-8b0355e\" data-id=\"8b0355e\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-fa3e914 elementor-widget elementor-widget-global elementor-global-18292 elementor-widget-pix-promo-box\" data-id=\"fa3e914\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Peristatic-pumps_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"READY FOR RELIABLE FLUID HANDLING?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/collections\/peristaltic-pumps\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">READY FOR RELIABLE FLUID HANDLING?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explore our peristaltic pumps for consistent and precise fluid delivery in your lab<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0106a5a elementor-widget elementor-widget-text-editor\" data-id=\"0106a5a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Pros and cons of peristaltic pumps for microfluidics<\/h2><h3>Pros<\/h3><ul><li>Long term experiments are possible: the reservoirs are not closed and can be refilled while the pump is working.<\/li><li>Robust and reliable: can work for weeks continuously.<\/li><li>Easy recirculation setup: the outlet tubing can be in the same reservoir than the inlet tubing.<\/li><li>Multichannel: you can extend the number of channels easily by changing the pump head. Generally, peristaltic pumps can be extended to up to 24 channels working at the same flow rate.<\/li><li>Wide range of pumps and pump heads to accommodate the user&rsquo;s requirements (tubing size, flow rate, environment&hellip;).<\/li><li>Some peristaltic pumps have a dispensing feature, and can be programmed to dispense a certain volume based on time.<\/li><\/ul><h3>Cons<\/h3><ul><li>Pulsatility: the peristaltism principle generates a more pulsatile flow than other technologies (syringe pumps, pressure controllers), while it is still stable on average. To compensate this pulsatility, more rollers can be added to the perisaltic pump head.<\/li><li>Tubing wear: the pressure applied by the rollers to the peristaltic tubing leads to tubing deformation by the time. The lifetime for a standard silicone tubing is approx. 200 hours, while it is approx. 1000 hours for specialized peristaltic tubing.<\/li><li>Flow rate: at low flow rates (below 10 &micro;L\/min), most of the peristaltic pumps are not accurate enough for microfluidic applications.<\/li><li>All the channels in a peristaltic pump have the same flow rate. Only one peristaltic pump can drive up to 4 channels independently, <span style=\"color: #0000ff;\"><a style=\"color: #0000ff;\" href=\"https:\/\/darwin-microfluidics.com\/products\/reglo-icc-independent-channel-control-pump\"><span style=\"text-decoration: underline;\"><strong>the Reglo ICC from ISMATEC<\/strong><\/span><\/a><\/span>.<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Functional principle of peristaltic pumps Peristaltic pumps are so-called roller pumps in which the rollers are rotated over a tube placed in the pump head, leading to the mechanical alteration of the form (squeezing) of the tube. The restitution of&hellip;<\/p>\n","protected":false},"author":3,"featured_media":14146,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[24,21],"tags":[],"class_list":["post-14138","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-control","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Peristaltic Pumping: How Does It Work? - Darwin Microfluidics<\/title>\n<meta name=\"description\" content=\"In this tutorial, you will learn how a peristaltic pump works with the pros and cons of using a peristaltic pump for microfluidics!\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Peristaltic Pumping: How Does It Work? - Darwin Microfluidics\" \/>\n<meta property=\"og:description\" content=\"In this tutorial, you will learn how a peristaltic pump works with the pros and cons of using a peristaltic pump for microfluidics!\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2023-02-16T16:08:43+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:12:22+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_4_large-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"480\" \/>\n\t<meta property=\"og:image:height\" content=\"346\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Colin Marquet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"3 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Peristaltic Pumping: How Does It Work?\",\"datePublished\":\"2023-02-16T16:08:43+00:00\",\"dateModified\":\"2026-11-19T14:12:22+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/\"},\"wordCount\":434,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Roller_pump_head_4_large-1.webp\",\"articleSection\":[\"Flow control\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/\",\"name\":\"Peristaltic Pumping: How Does It Work? - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Roller_pump_head_4_large-1.webp\",\"datePublished\":\"2023-02-16T16:08:43+00:00\",\"dateModified\":\"2026-11-19T14:12:22+00:00\",\"description\":\"In this tutorial, you will learn how a peristaltic pump works with the pros and cons of using a peristaltic pump for microfluidics!\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Roller_pump_head_4_large-1.webp\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/Roller_pump_head_4_large-1.webp\",\"width\":480,\"height\":346,\"caption\":\"Drawing of a Roller pump head\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/peristaltic-pumping-how-does-it-work\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Peristaltic Pumping: How Does It Work?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/colinmarquet\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Peristaltic Pumping: How Does It Work? - Darwin Microfluidics","description":"In this tutorial, you will learn how a peristaltic pump works with the pros and cons of using a peristaltic pump for microfluidics!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/","og_locale":"en_US","og_type":"article","og_title":"Peristaltic Pumping: How Does It Work? - Darwin Microfluidics","og_description":"In this tutorial, you will learn how a peristaltic pump works with the pros and cons of using a peristaltic pump for microfluidics!","og_url":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-16T16:08:43+00:00","article_modified_time":"2026-11-19T14:12:22+00:00","og_image":[{"width":480,"height":346,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_4_large-1.webp","type":"image\/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"3 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/"},"author":{"name":"Colin Marquet","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677"},"headline":"Peristaltic Pumping: How Does It Work?","datePublished":"2023-02-16T16:08:43+00:00","dateModified":"2026-11-19T14:12:22+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/"},"wordCount":434,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_4_large-1.webp","articleSection":["Flow control","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/","url":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/","name":"Peristaltic Pumping: How Does It Work? - Darwin Microfluidics","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_4_large-1.webp","datePublished":"2023-02-16T16:08:43+00:00","dateModified":"2026-11-19T14:12:22+00:00","description":"In this tutorial, you will learn how a peristaltic pump works with the pros and cons of using a peristaltic pump for microfluidics!","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_4_large-1.webp","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_4_large-1.webp","width":480,"height":346,"caption":"Drawing of a Roller pump head"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/peristaltic-pumping-how-does-it-work\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"Peristaltic Pumping: How Does It Work?"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/colinmarquet\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Roller_pump_head_4_large-1.webp","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14138","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=14138"}],"version-history":[{"count":11,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14138\/revisions"}],"predecessor-version":[{"id":18498,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14138\/revisions\/18498"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/14146"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=14138"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=14138"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=14138"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}