{"id":14244,"date":"2023-02-20T12:55:25","date_gmt":"2023-02-20T11:55:25","guid":{"rendered":"http:\/\/eqgkrdm.cluster031.hosting.ovh.net\/?p=14244"},"modified":"2026-11-19T15:12:38","modified_gmt":"2026-11-19T14:12:38","slug":"fluoropolymer-tubing-in-microfluidics-a-short-guide","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/","title":{"rendered":"Fluoropolymer tubing in microfluidics: a short guide"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14244\" class=\"elementor elementor-14244\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-658fe96 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"658fe96\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-906cfac\" data-id=\"906cfac\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-ba6a4b6 elementor-widget elementor-widget-text-editor\" data-id=\"ba6a4b6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Tubing is an essential element in the design of your microfluidic platform, being the link between the different components of this platform. As it is in contact with the fluids, the choice of tubing is mainly determined by the chemical compatibility with the fluids you use, but also by other parameters (pressure in the system, compatibility with the elements in your setup, etc.).<\/p><p>Given the large number of materials used, it is easy to get lost. In this guide, we compare the different types of fluoropolymers available on the market and their physico-chemical properties.<\/p><h2>Dimensions<\/h2><p>Let&rsquo;s first take a look at some of the dimensions and main abbreviations, which will be useful to define your needs.<\/p><p>&nbsp;<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e7c4df elementor-widget elementor-widget-image\" data-id=\"5e7c4df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"480\" height=\"357\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Dimensions-tubing-microfluidics_480x480-transformed-1.png\" class=\"attachment-large size-large wp-image-14246\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Dimensions-tubing-microfluidics_480x480-transformed-1.png 480w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Dimensions-tubing-microfluidics_480x480-transformed-1-300x223.png 300w\" sizes=\"(max-width: 480px) 100vw, 480px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1: cross section of a tubing.<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97e87fa elementor-widget elementor-widget-text-editor\" data-id=\"97e87fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Fluoropolymer tubing for microfluidics<\/h2><h3>PTFE (PolyTetraFluoroEthylene, often described as Teflon&reg;)<\/h3><p><span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/darwin-microfluidics.com\/collections\/ptfe-peek-fep-tubing\/products\/ptfe-tubing-1-16-od-for-microfluidics\">PTFE<\/a><\/strong><\/span> tubing has the best performances in terms of chemical and thermal resistance and non-stick properties. Compared to similar fluoropolymers, PTFE offers the best price\/performance ratio. In fact, it has many advantages, including unrivaled chemical resistance, a surface that facilitates flow, non-toxicity and chemical inert properties. When used in microfluidics, its rigidity can stabilize the flow rate and increase the reactivity of your microfluidic system.<\/p><p>PTFE can operate from -190&deg;C to 260&deg;C, and has a very low water <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">absorption<\/a> rate (&lt; 0.01%).<\/p><h3>FEP (Fluorinated Ethylene-Propylene)<\/h3><p>This attractive alternative to PTFE tubes has many similar properties such as biocompatibility and remarkable inertness to most chemicals. FEP is the preferred material in production of small diameter tubing of continuous lengths. Like PTFE, this flexible material is mainly used for low-pressure microfluidic applications. In addition, thanks to its excellent clarity, it is ideal for sight glass\/flow monitoring applications. FEP tubing also has better gas and vapor permeability properties and excellent UV transmission ratings.<\/p><p><span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/darwin-microfluidics.com\/products\/fep-tubing-20-m\">FEP tubing<\/a><\/strong><\/span> can operate between -190&deg;C and 205&deg;C, has a slightly higher coefficient of friction, and is more transparent than PTFE.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-46e38fa elementor-widget elementor-widget-image\" data-id=\"46e38fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Tubing-1-32-OD-for-Microfluidics-transformed-1-300x300.png\" class=\"attachment-medium size-medium wp-image-14252\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Tubing-1-32-OD-for-Microfluidics-transformed-1-300x300.png 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Tubing-1-32-OD-for-Microfluidics-transformed-1-150x150.png 150w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Tubing-1-32-OD-for-Microfluidics-transformed-1-768x768.png 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Tubing-1-32-OD-for-Microfluidics-transformed-1-400x400.png 400w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Tubing-1-32-OD-for-Microfluidics-transformed-1-75x75.png 75w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Tubing-1-32-OD-for-Microfluidics-transformed-1-460x460.png 460w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Tubing-1-32-OD-for-Microfluidics-transformed-1.png 1000w\" sizes=\"(max-width: 300px) 100vw, 300px\"\/>\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 2: PTFE tubing on a spooler<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef6af1c elementor-widget elementor-widget-global elementor-global-18316 elementor-widget-pix-promo-box\" data-id=\"ef6af1c\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta1\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Tubing_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"LOOKING FOR FLEXIBILITY IN TUBING OPTIONS?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/collections\/microfluidic-tubings\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">LOOKING FOR FLEXIBILITY IN TUBING OPTIONS?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explore our microfluidic tubing solutions for reliable and efficient flow in your experiments!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e4a021 elementor-widget elementor-widget-text-editor\" data-id=\"2e4a021\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>FEP (Fluorinated Ethylene-Propylene)<\/h3><p>This attractive alternative to PTFE tubes has many similar properties such as biocompatibility and remarkable inertness to most chemicals. FEP is the preferred material in production of small diameter tubing of continuous lengths. Like PTFE, this flexible material is mainly used for low-pressure microfluidic applications. In addition, thanks to its excellent clarity, it is ideal for sight glass\/flow monitoring applications. FEP tubing also has better gas and vapor permeability properties and excellent UV transmission ratings.<\/p><p><span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/darwin-microfluidics.com\/products\/fep-tubing-20-m\">FEP tubing<\/a><\/strong><\/span> can operate between -190&deg;C and 205&deg;C, has a slightly higher coefficient of friction, and is more transparent than PTFE.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1da589a elementor-widget elementor-widget-image\" data-id=\"1da589a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/darwin-microfluidics.com\/products\/fep-tubing-20-m\">\n\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FEP-Tubing-transformed-1-300x300.png\" class=\"attachment-medium size-medium wp-image-14248\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FEP-Tubing-transformed-1-300x300.png 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FEP-Tubing-transformed-1-150x150.png 150w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FEP-Tubing-transformed-1-768x768.png 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FEP-Tubing-transformed-1-400x400.png 400w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FEP-Tubing-transformed-1-75x75.png 75w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FEP-Tubing-transformed-1-460x460.png 460w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/FEP-Tubing-transformed-1.png 1000w\" sizes=\"(max-width: 300px) 100vw, 300px\"\/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 3: FEP Tubing<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ded4f1d elementor-widget elementor-widget-text-editor\" data-id=\"ded4f1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>PEEK (Poly Ether Ether Ketone)<\/h3><p>PEEK is often considered as one of the most performant polymers, and is commonly used in microfluidics for its reliability and resistance to pressure. It combines high mechanical and chemical resistance properties, together with a working temperature range from -40&deg;C to 250&deg;C. <span style=\"color: #0000ff;\"><strong><span style=\"text-decoration: underline;\"><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/darwin-microfluidics.com\/collections\/ptfe-peek-fep-tubing\/products\/1-16-od-peek-capillary-tubing\">PEEK tubing<\/a><\/span><\/strong><\/span> has one of the highest strength-to-weight ratios of all thermoplastics and can be used in numerous low and high pressure applications. It is inert to most solvents and has a smooth internal surface that increases the swept volume.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-96ce101 elementor-widget elementor-widget-image\" data-id=\"96ce101\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/darwin-microfluidics.com\/collections\/ptfe-peek-fep-tubing\/products\/1-16-od-peek-capillary-tubing?variant=31501752107144\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PEEK-Tubing-125-um-transformed-1-300x300.png\" class=\"attachment-medium size-medium wp-image-14253\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PEEK-Tubing-125-um-transformed-1-300x300.png 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PEEK-Tubing-125-um-transformed-1-150x150.png 150w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PEEK-Tubing-125-um-transformed-1-768x768.png 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PEEK-Tubing-125-um-transformed-1-400x400.png 400w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PEEK-Tubing-125-um-transformed-1-75x75.png 75w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PEEK-Tubing-125-um-transformed-1-460x460.png 460w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PEEK-Tubing-125-um-transformed-1.png 1000w\" sizes=\"(max-width: 300px) 100vw, 300px\"\/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 4: 1\/16\" OD PEEK Capillary Tubing<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e33b89 elementor-widget elementor-widget-text-editor\" data-id=\"6e33b89\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>PFA (PerFluoroAlkoxy)<\/h3><p><span style=\"text-decoration: underline;\"><strong><span style=\"color: #0000ff; text-decoration: underline;\"><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/darwin-microfluidics.com\/products\/pfa-tubing-20-m?variant=41077612249252\">PFA tubing<\/a><\/span><\/strong><\/span> is the right choice when high optical clarity, flexibility and high continuous working temperatures are required. It combines the properties of FEP and PTFE, with working temperatures to -200&deg;C to 260&deg;C. PFA has a lower melting temperature than PTFE, is UV resistant, and has a very low water <a class=\"glossaryLink\" href=\"https:\/\/blog.darwin-microfluidics.com\/glossary\/absorption-microfluidics-explained\/\" data-mobile-support=\"0\" data-gt-translate-attributes='[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]' tabindex=\"0\" role=\"link\">absorption<\/a> rate (&lt; 0.01%).<\/p><h3>ETFE (Ethylene TetraFluoroEthylene)<\/h3><p>ETFE is chemically inert and offers very good resistance to solvents. It has a stiffer structure than PTFE, FEP and PFA, which makes the tube more resistant to collapse. Also, this material offers greater durability and is less permeable to gases than other types of tubing. Its operating temperature ranges from -200&deg;C to 150&deg;C.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3e37c5c elementor-widget elementor-widget-image\" data-id=\"3e37c5c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t\t<a href=\"https:\/\/darwin-microfluidics.com\/products\/fluidic-connect-pro-etfe-connection-kit\">\n\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"300\" height=\"300\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Fluidic-Connect-Pro-ETFE-Connection-Kit_2048x2048-transformed-1-300x300.png\" class=\"attachment-medium size-medium wp-image-14254\" alt=\"\" srcset=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Fluidic-Connect-Pro-ETFE-Connection-Kit_2048x2048-transformed-1-300x300.png 300w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Fluidic-Connect-Pro-ETFE-Connection-Kit_2048x2048-transformed-1-150x150.png 150w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Fluidic-Connect-Pro-ETFE-Connection-Kit_2048x2048-transformed-1-768x768.png 768w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Fluidic-Connect-Pro-ETFE-Connection-Kit_2048x2048-transformed-1-400x400.png 400w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Fluidic-Connect-Pro-ETFE-Connection-Kit_2048x2048-transformed-1-75x75.png 75w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Fluidic-Connect-Pro-ETFE-Connection-Kit_2048x2048-transformed-1-460x460.png 460w, https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/Fluidic-Connect-Pro-ETFE-Connection-Kit_2048x2048-transformed-1.png 1000w\" sizes=\"(max-width: 300px) 100vw, 300px\"\/>\t\t\t\t\t\t\t\t<\/a>\n\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 5: Fluidic Connect Pro ETFE Tubing<\/figcaption>\n\t\t\t\t\t\t\t\t\t\t<\/figure>\n\t\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1c296ac elementor-widget elementor-widget-text-editor\" data-id=\"1c296ac\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Tubing and connectors<\/h2><p>As explained in details here <span style=\"color: #0000ff;\"><strong><span style=\"text-decoration: underline;\"><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/blog.darwin-microfluidics.com\/internal-volume-swept-volume-dead-volume-in-microfluidics\/\">(Internal volume, swept volume, dead volume in microfluidics<\/a><\/span><\/strong><\/span>), it is important to choose connectors that reduce the internal volume as much as possible. Darwin Microfluidics offers a selection of tubing and connectors with low internal volume, which can be found in our <span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/darwin-microfluidics.com\/collections\/microfluidic-tubings\">Tubing<\/a><\/strong><\/span> and <span style=\"text-decoration: underline; color: #0000ff;\"><strong><a style=\"color: #0000ff; text-decoration: underline;\" href=\"https:\/\/darwin-microfluidics.com\/collections\/microfluidic-fittings-connectors\">Fittings &amp; Connectors<\/a><\/strong><\/span> sections.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0282626 elementor-widget elementor-widget-global elementor-global-18310 elementor-widget-pix-promo-box\" data-id=\"0282626\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Essentials_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"SEEKING THE BUILDING BLOCKS OF INNOVATION?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/collections\/microfluidic-accessories\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">SEEKING THE BUILDING BLOCKS OF INNOVATION?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explore our essential tools to kickstart your journey in microfluidics<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Tubing is an essential element in the design of your microfluidic platform, being the link between the different components of this platform. As it is in contact with the fluids, the choice of tubing is mainly determined by the chemical&hellip;<\/p>\n","protected":false},"author":3,"featured_media":14781,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[28,33],"tags":[],"class_list":["post-14244","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-connectors-tubing","category-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Fluoropolymer tubing in microfluidics: a short guide<\/title>\n<meta name=\"description\" content=\"Given the large number of materials used, it is easy to get lost. In this guide, we compare the different types of fluoropolymers available.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Fluoropolymer tubing in microfluidics: a short guide\" \/>\n<meta property=\"og:description\" content=\"Given the large number of materials used, it is easy to get lost. In this guide, we compare the different types of fluoropolymers available.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2023-02-20T11:55:25+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:12:38+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Teflon-Tubing_2048x2048-1.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"919\" \/>\n\t<meta property=\"og:image:height\" content=\"919\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"Colin Marquet\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Fluoropolymer tubing in microfluidics: a short guide\",\"datePublished\":\"2023-02-20T11:55:25+00:00\",\"dateModified\":\"2026-11-19T14:12:38+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/\"},\"wordCount\":744,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/PTFE-Teflon-Tubing_2048x2048-1.webp\",\"articleSection\":[\"Connectors &amp; tubing\",\"Guides &amp; tutorials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/\",\"name\":\"Fluoropolymer tubing in microfluidics: a short guide\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/PTFE-Teflon-Tubing_2048x2048-1.webp\",\"datePublished\":\"2023-02-20T11:55:25+00:00\",\"dateModified\":\"2026-11-19T14:12:38+00:00\",\"description\":\"Given the large number of materials used, it is easy to get lost. In this guide, we compare the different types of fluoropolymers available.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/PTFE-Teflon-Tubing_2048x2048-1.webp\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2023\\\/02\\\/PTFE-Teflon-Tubing_2048x2048-1.webp\",\"width\":919,\"height\":919,\"caption\":\"photography of a fluoropolymer tubing\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/fluoropolymer-tubing-in-microfluidics-a-short-guide\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Fluoropolymer tubing in microfluidics: a short guide\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/colinmarquet\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Fluoropolymer tubing in microfluidics: a short guide","description":"Given the large number of materials used, it is easy to get lost. In this guide, we compare the different types of fluoropolymers available.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/","og_locale":"en_US","og_type":"article","og_title":"Fluoropolymer tubing in microfluidics: a short guide","og_description":"Given the large number of materials used, it is easy to get lost. In this guide, we compare the different types of fluoropolymers available.","og_url":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-20T11:55:25+00:00","article_modified_time":"2026-11-19T14:12:38+00:00","og_image":[{"width":919,"height":919,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Teflon-Tubing_2048x2048-1.webp","type":"image\/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/"},"author":{"name":"Colin Marquet","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677"},"headline":"Fluoropolymer tubing in microfluidics: a short guide","datePublished":"2023-02-20T11:55:25+00:00","dateModified":"2026-11-19T14:12:38+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/"},"wordCount":744,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Teflon-Tubing_2048x2048-1.webp","articleSection":["Connectors &amp; tubing","Guides &amp; tutorials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/","url":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/","name":"Fluoropolymer tubing in microfluidics: a short guide","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Teflon-Tubing_2048x2048-1.webp","datePublished":"2023-02-20T11:55:25+00:00","dateModified":"2026-11-19T14:12:38+00:00","description":"Given the large number of materials used, it is easy to get lost. In this guide, we compare the different types of fluoropolymers available.","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Teflon-Tubing_2048x2048-1.webp","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Teflon-Tubing_2048x2048-1.webp","width":919,"height":919,"caption":"photography of a fluoropolymer tubing"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/fluoropolymer-tubing-in-microfluidics-a-short-guide\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"Fluoropolymer tubing in microfluidics: a short guide"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/colinmarquet\/"}]}},"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2023\/02\/PTFE-Teflon-Tubing_2048x2048-1.webp","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14244","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=14244"}],"version-history":[{"count":15,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14244\/revisions"}],"predecessor-version":[{"id":18473,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/14244\/revisions\/18473"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/14781"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=14244"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=14244"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=14244"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}