{"id":17362,"date":"2024-02-13T18:04:04","date_gmt":"2024-02-13T17:04:04","guid":{"rendered":"https:\/\/blog.darwin-microfluidics.com\/?p=17362"},"modified":"2026-11-19T15:14:10","modified_gmt":"2026-11-19T14:14:10","slug":"how-to-control-the-longer-bt100-1l-pump-via-matlab","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/","title":{"rendered":"How to Control the Longer BT100-1L Pump via Matlab ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"17362\" class=\"elementor elementor-17362\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-56ff874 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"56ff874\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-ab1518f\" data-id=\"ab1518f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-83cf3d7 elementor-widget elementor-widget-text-editor\" data-id=\"83cf3d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>If you are looking for a <strong>precision peristaltic pump<\/strong> that can handle multiple channels simultaneously (up to 24), you might want to check out the<strong> Longer <a href=\"https:\/\/darwin-microfluidics.com\/products\/microfluidic-2-24-channel-peristaltic-pump?variant=43791085273323\" target=\"_blank\" rel=\"noopener\">BT100-1L<\/a><\/strong>. This pump can deliver flow rates ranging from 2 &micro;L\/min to 366.7 mL\/min depending on the number of rollers in the pump head. It is also a relatively cheap peristaltic pump that has a wide range of applications.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a80d9d4 elementor-widget elementor-widget-text-editor\" data-id=\"a80d9d4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The&nbsp;BT100-1L can be controlled remotely from your computer which can give you more flexibility and convenience, especially if you want to run complex pumping programs with loops, pauses, and varying flow rates.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e892d2 elementor-widget elementor-widget-text-editor\" data-id=\"8e892d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In this blog post, we will show you how to communicate with the BT100-1L using the <strong>LONGER RS485 protocol<\/strong>, which is a serial communication protocol that allows you to send commands and receive responses from the pump. We will also provide some examples and <a href=\"#code\">code snippets<\/a> on how to use <strong>Matlab<\/strong> to write and send control command strings to the pump.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f08a617 elementor-toc--content-ellipsis elementor-toc--minimized-on-tablet elementor-widget elementor-widget-table-of-contents\" data-id=\"f08a617\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings='{\"exclude_headings_by_selector\":\"#cta1, #cta2\",\"headings_by_tags\":[\"h2\",\"h3\"],\"marker_view\":\"numbers\",\"no_headings_message\":\"No headings were found on this page.\",\"minimize_box\":\"yes\",\"minimized_on\":\"tablet\",\"hierarchical_view\":\"yes\",\"min_height\":{\"unit\":\"px\",\"size\":\"\",\"sizes\":[]},\"min_height_tablet\":{\"unit\":\"px\",\"size\":\"\",\"sizes\":[]},\"min_height_mobile\":{\"unit\":\"px\",\"size\":\"\",\"sizes\":[]}}' data-widget_type=\"table-of-contents.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__header\">\n\t\t\t\t\t\t<h4 class=\"elementor-toc__header-title\">\n\t\t\t\tTABLE OF CONTENTS\t\t\t<\/h4>\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--expand\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__f08a617\" aria-expanded=\"true\" aria-label=\"Open table of contents\"><i aria-hidden=\"true\" class=\"fas fa-chevron-down\"><\/i><\/div>\n\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--collapse\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__f08a617\" aria-expanded=\"true\" aria-label=\"Close table of contents\"><i aria-hidden=\"true\" class=\"fas fa-chevron-up\"><\/i><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"elementor-toc__f08a617\" class=\"elementor-toc__body\">\n\t\t\t<div class=\"elementor-toc__spinner-container\">\n\t\t\t\t<i class=\"elementor-toc__spinner eicon-animation-spin eicon-loading\" aria-hidden=\"true\"><\/i>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-fb5566c elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"fb5566c\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-0dbd2f3\" data-id=\"0dbd2f3\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-023836d elementor-widget elementor-widget-heading\" data-id=\"023836d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What do you need to communicate with the BT100-1L ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e73df12 elementor-widget elementor-widget-text-editor\" data-id=\"e73df12\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>To communicate with the BT100-1L using the LONGER RS485 protocol, you will need the following:<\/p><ul><li>A BT100-1L pump with a <a href=\"https:\/\/darwin-microfluidics.com\/collections\/peristaltic-pump-heads\">pump head<\/a> and a <a href=\"https:\/\/darwin-microfluidics.com\/collections\/peristaltic-pump-tubing\">tubing<\/a> of your choice<\/li><li>A RS485 <a href=\"https:\/\/darwin-microfluidics.com\/collections\/peristaltic-pump-accessories\/products\/external-control-module-for-longer-pumps\">control module<\/a> that plugs into the DB15 port on the rear of the pump<\/li><li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">A <a href=\"https:\/\/darwin-microfluidics.com\/products\/usb-to-rs485-serial-converter-cable\/\">serial cable<\/a> that connects the RS485 control module to your computer or device<\/span><\/li><li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">A programming platform (Matlab in the case herein)<\/span><\/li><li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">A basic understanding of the data format, command format, and pdu format of the LONGER RS485 protocol (explained below <a href=\"#pdu\">&#128071;<\/a>)<\/span><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9021596 elementor-widget elementor-widget-global elementor-global-18316 elementor-widget-pix-promo-box\" data-id=\"9021596\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta1\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Tubing_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"LOOKING FOR FLEXIBILITY IN TUBING OPTIONS?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/collections\/microfluidic-tubings\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">LOOKING FOR FLEXIBILITY IN TUBING OPTIONS?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explore our microfluidic tubing solutions for reliable and efficient flow in your experiments!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e53b025 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e53b025\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-06c7007\" data-id=\"06c7007\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-861069a elementor-widget elementor-widget-heading\" data-id=\"861069a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How to Set Up the Communication Port ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8b56a35 elementor-widget elementor-widget-text-editor\" data-id=\"8b56a35\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Before you can start sending and receiving data from the pump, you need to set up the communication port correctly. Here are the steps to follow:\n<\/p><ul>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Connect the DB15 connector to the DB15 port on the rear of the pump<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Turn on the pump and press the adjusting knob on the pump front to enter the remote control setting interface and enable remote control mode &#128377;&#65039;<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Make sure the communication parameters on your programming platform match the ones of the BT100-1L, which are:<\/span>\n<ul>\n \t<li><span style=\"font-weight: 400;\">1 start bit<\/span><\/li>\n \t<li><span style=\"font-weight: 400;\">8 data bits<\/span><\/li>\n \t<li><span style=\"font-weight: 400;\">1 even parity<\/span><\/li>\n \t<li><span style=\"font-weight: 400;\">1 stop bit<\/span><\/li>\n \t<li><span style=\"font-weight: 400;\">a baud rate of 1200 bits\/s<\/span><\/li>\n<\/ul>\n<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2bd03cf elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2bd03cf\" data-element_type=\"section\" data-e-type=\"section\" id=\"pdu\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-fbfeb75\" data-id=\"fbfeb75\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-893dd51 elementor-widget elementor-widget-heading\" data-id=\"893dd51\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How to Write Control Command Strings to the BT100-1L ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fb7da07 elementor-widget elementor-widget-text-editor\" data-id=\"fb7da07\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Once you have set up the communication port, you can start writing and sending control command strings to the pump. A control command string is a sequence of hexadecimal characters that follows a specific format, which consists of:\n<\/p><ul>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">a start flag (E9H)<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">a pump address (1 to 30, or 31 for broadcast)<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">a length of the pdu (protocol data unit)<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">a pdu, which contains the command characters and the parameters for the desired application<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">a frame check sequence (fcs), which is obtained by calculating the XOR of the pump address, the length of the pdu, and the pdu itself (compute your fcs using our online <a href=\"https:\/\/blog.darwin-microfluidics.com\/frame-check-sequence-xor-calculator-for-longer-pump-control\/\">frame check sequence XOR calculator<\/a>)<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cabb06f elementor-widget elementor-widget-text-editor\" data-id=\"cabb06f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The pdu and its length depend on the application requested from the pump. Some of the common applications are:\n<\/p><ul>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Set running parameter (rotation speed)<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Read running parameter (rotation speed)<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Set running parameter (flow rate) with pump head and tube<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Read running parameter (flow rate) with pump head and tube<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Flow calibration<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-00320ad elementor-widget elementor-widget-text-editor\" data-id=\"00320ad\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400\">For each application, there is a corresponding set of command characters and parameters that you need to include in the pdu. These parameters are detailed below.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ef0032 elementor-widget elementor-widget-heading\" data-id=\"4ef0032\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Set running parameter (rotation speed)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5dbe777 elementor-widget elementor-widget-text-editor\" data-id=\"5dbe777\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This application consists of writing to the pump. The overall length of the pdu is <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">6 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\"> where the control command string consists of (in the exact same order):<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b6c46c elementor-widget elementor-widget-shortcode\" data-id=\"1b6c46c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-1\" class=\"tablepress tablepress-id-1\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">XL<\/td><td class=\"column-2\">Set Speed<\/td><td class=\"column-3\">State 1<\/td><td class=\"column-4\">State 2<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">2 bytes<\/td><td class=\"column-2\">2 bytes<\/td><td class=\"column-3\">1 byte<\/td><td class=\"column-4\">1 byte<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-1 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-28c1bee elementor-widget elementor-widget-text-editor\" data-id=\"28c1bee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>XL, control command string of <span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">, 58 4C<\/span><\/li>\n \t<li>Set speed (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">) with a speed unit of 0.1 rpm and a maximum speed of 100 rpm (03 E8)<\/span><\/li>\n \t<li>State 1 (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">):&nbsp;<\/span>\n<ul>\n \t<li>bit 0 &ndash; start\/stop bit where 1 is to start the pump and 0 is to stop it<\/li>\n \t<li>bit 1 &ndash; prime bit where 1 is to prime the pump at the max speed of 100 rpm and 0 is to run the pump at a normal speed<\/li>\n<\/ul>\n<\/li>\n \t<li>State 2 (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">):<\/span>\n<ul>\n \t<li>bit 0 &ndash; sets the&nbsp;<span style=\"letter-spacing: -0.16px;\">rotation&nbsp;<\/span>direction where 1 is for clockwise and 0 is for counter-clockwise<\/li>\n<\/ul>\n<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e08407 elementor-widget elementor-widget-text-editor\" data-id=\"6e08407\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The pump will respond with <span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">XL<\/span><\/span><span style=\"font-weight: 400;\">&nbsp;and will display on its front screen the rotation speed and the direction of rotation after receiving the control command string.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5acef1d elementor-widget elementor-widget-heading\" data-id=\"5acef1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Read running parameter (rotation speed)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9d6123a elementor-widget elementor-widget-text-editor\" data-id=\"9d6123a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This application consists of reading from the pump. The overall length of the pdu is <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">2 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\"> where the control command string is <\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; vertical-align: baseline; white-space-collapse: preserve; background-color: #cccccc;\"><span style=\"color: #111111;\">DL<\/span><\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\">.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-000e9fe elementor-widget elementor-widget-text-editor\" data-id=\"000e9fe\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The pump&rsquo;s response consists of:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-27d818a elementor-widget elementor-widget-shortcode\" data-id=\"27d818a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-2\" class=\"tablepress tablepress-id-2\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">DL<\/td><td class=\"column-2\">Show Speed<\/td><td class=\"column-3\">State 1<\/td><td class=\"column-4\">State 2<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">2 bytes<\/td><td class=\"column-2\">2 bytes<\/td><td class=\"column-3\">1 byte<\/td><td class=\"column-4\">1 byte<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-2 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-edf76a7 elementor-widget elementor-widget-text-editor\" data-id=\"edf76a7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>DL, control command string of <span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">, 44 4C<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08656fa elementor-widget elementor-widget-heading\" data-id=\"08656fa\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Set running parameter (flow rate) with pump head and tube<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cd309d2 elementor-widget elementor-widget-text-editor\" data-id=\"cd309d2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This application consists of writing to the pump. The overall length of the pdu is <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">10 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\"> where the control command string consists of:<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-212c8e5 elementor-widget-mobile__width-auto elementor-widget elementor-widget-shortcode\" data-id=\"212c8e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-8\" class=\"tablepress tablepress-id-8\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">WL<\/td><td class=\"column-2\">2 bytes<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Set flow rate<\/td><td class=\"column-2\">4 bytes<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">State 1<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">State 2<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Pump head number<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Tube number<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-8 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c16e5d elementor-widget elementor-widget-text-editor\" data-id=\"3c16e5d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>WL, control command string of <span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">, 57 4C<\/span><\/li>\n \t<li>Set flow rate (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">4 bytes<\/span><span style=\"font-weight: 400;\">) with a nL\/min flow rate unit<\/span><\/li>\n \t<li>State 1 (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span><span style=\"font-weight: 400;\">) and State 2 (<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span><\/span><span style=\"font-weight: 400;\">) as already explained&nbsp;<\/span><\/li>\n \t<li>Pump head number (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span><span style=\"font-weight: 400;\">), as presented in the tables below:<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8edbe87 elementor-widget-mobile__width-auto elementor-widget elementor-widget-shortcode\" data-id=\"8edbe87\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-11\" class=\"tablepress tablepress-id-11\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Pump head<\/th><th class=\"column-2\">Characters<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">DG (6 rollers)<\/td><td class=\"column-2\">01<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">DG (10 rollers)<\/td><td class=\"column-2\">02<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">YZ1515\/YZ2515<\/td><td class=\"column-2\">03<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">313D<\/td><td class=\"column-2\">04<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">DG15<\/td><td class=\"column-2\">05<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-11 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cfa21a5 elementor-widget elementor-widget-text-editor\" data-id=\"cfa21a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>Tube number (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span><span style=\"font-weight: 400;\">), as presented in the table below:<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5cadc2e elementor-widget-mobile__width-auto elementor-widget elementor-widget-shortcode\" data-id=\"5cadc2e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-12\" class=\"tablepress tablepress-id-12\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Tubing ID (mm)<br>\n01: DG (6 rollers)<br>\n02: DG (10 rollers)<br>\n05: DG15<\/th><th class=\"column-2\">Tube number<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">0.13<\/td><td class=\"column-2\">01<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">0.19<\/td><td class=\"column-2\">02<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">0.25<\/td><td class=\"column-2\">03<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">0.38<\/td><td class=\"column-2\">04<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">0.44<\/td><td class=\"column-2\">05<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">0.51<\/td><td class=\"column-2\">06<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">0.57<\/td><td class=\"column-2\">07<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">0.64<\/td><td class=\"column-2\">08<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">0.76<\/td><td class=\"column-2\">09<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">0.89<\/td><td class=\"column-2\">10<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">0.95<\/td><td class=\"column-2\">11<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">1.02<\/td><td class=\"column-2\">12<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">1.09<\/td><td class=\"column-2\">13<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">1.14<\/td><td class=\"column-2\">14<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">1.22<\/td><td class=\"column-2\">15<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">1.30<\/td><td class=\"column-2\">16<\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">1.42<\/td><td class=\"column-2\">17<\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">1.54<\/td><td class=\"column-2\">18<\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">1.65<\/td><td class=\"column-2\">19<\/td>\n<\/tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">1.75<\/td><td class=\"column-2\">20<\/td>\n<\/tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">1.85<\/td><td class=\"column-2\">21<\/td>\n<\/tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">2.06<\/td><td class=\"column-2\">22<\/td>\n<\/tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">2.29<\/td><td class=\"column-2\">23<\/td>\n<\/tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">2.54<\/td><td class=\"column-2\">24<\/td>\n<\/tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">2.79<\/td><td class=\"column-2\">25<\/td>\n<\/tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">3.17<\/td><td class=\"column-2\">26<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-12 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b5dd55a elementor-widget-mobile__width-auto elementor-widget elementor-widget-shortcode\" data-id=\"b5dd55a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-13\" class=\"tablepress tablepress-id-13\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Tubing ID (mm)<br>\n3: YZ1515\/YZ2515<br>\n4: 313D<\/th><th class=\"column-2\">Characters<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">0.8<\/td><td class=\"column-2\">01<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">1.6<\/td><td class=\"column-2\">02<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">2.4<\/td><td class=\"column-2\">03<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">3.1<\/td><td class=\"column-2\">04<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">4.8<\/td><td class=\"column-2\">05<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">6.4<\/td><td class=\"column-2\">06<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">7.9<\/td><td class=\"column-2\">07<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">9.6<\/td><td class=\"column-2\">08<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-13 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-880729a elementor-widget elementor-widget-text-editor\" data-id=\"880729a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The pump will respond with <span style=\"font-size: 12pt; font-family: Arial, sans-serif; vertical-align: baseline;\"><span style=\"color: #111111;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">WL<\/span><\/span><\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; vertical-align: baseline;\"><span style=\"color: #000000;\">&nbsp;<\/span><\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">Show flow rate (<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">4 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">)<\/span> and will display on its front screen the flow rate, the corresponding rotation speed and the direction of rotation after receiving the control command string.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-93809c9 elementor-widget elementor-widget-heading\" data-id=\"93809c9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Read running parameter (flow rate) with pump head and tube<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eb318a5 elementor-widget elementor-widget-text-editor\" data-id=\"eb318a5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This application consists of reading from the pump. The overall length of the pdu is <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">2 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\"> where the control command string is <\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\"><span style=\"color: #111111; letter-spacing: -0.16px; white-space-collapse: preserve; background-color: #cccccc;\">RL<\/span>.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ce8cf39 elementor-widget elementor-widget-text-editor\" data-id=\"ce8cf39\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The pump&rsquo;s response consists of:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-af69cfd elementor-widget elementor-widget-shortcode\" data-id=\"af69cfd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-10\" class=\"tablepress tablepress-id-10\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">RL<\/td><td class=\"column-2\">2 bytes<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Show flow rate<\/td><td class=\"column-2\">4 bytes<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">State 1<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">State 2<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Pump head number<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Tube number<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-10 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c515d81 elementor-widget elementor-widget-text-editor\" data-id=\"c515d81\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>RL, control command string of <span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">, 52 4C<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-eee15f8 elementor-widget elementor-widget-heading\" data-id=\"eee15f8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Flow calibration<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-68ef856 elementor-widget elementor-widget-text-editor\" data-id=\"68ef856\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This application consists of writing to the pump. The overall length of the pdu is <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">6 bytes<\/span> where the control command string consists of:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a0dc1d6 elementor-widget elementor-widget-shortcode\" data-id=\"a0dc1d6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-7\" class=\"tablepress tablepress-id-7\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">CL<\/td><td class=\"column-2\">Test flow rate<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">2 bytes<\/td><td class=\"column-2\">4 bytes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-7 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f394a19 elementor-widget elementor-widget-text-editor\" data-id=\"f394a19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>CL, control command string of <span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 bytes<\/span>, 43 4C<\/li>\n \t<li>Test flow rate (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">4 bytes<\/span><span style=\"font-weight: 400;\">) with a nL\/min flow rate unit<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0738e1c elementor-widget elementor-widget-heading\" data-id=\"0738e1c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Examples of control command strings<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6fd7d11 elementor-widget elementor-widget-text-editor\" data-id=\"6fd7d11\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Set the BT100-1L to run clockwise at a rotating speed of 20 rpm<\/strong><\/li><\/ul><p><span style=\"font-weight: 400;\">Control command string:&nbsp;<\/span><span style=\"background-color: #cccccc; color: #000000; font-family: Arial, sans-serif; font-size: 12pt; white-space-collapse: preserve; letter-spacing: -0.01rem;\">E9 01 06 58 4C 00 C8 01 01 DB<\/span><\/p><ul><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">E9<\/span>&nbsp;as the flag<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;as the address 1 of the pump<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">06<\/span>&nbsp;as the length of the pdu (<span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">58 4C 00 C8 01 01<\/span><\/span><\/span><span style=\"font-weight: 400;\">)<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">58 4C<\/span><\/span> as command characters XL<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">00 C8<\/span> refers to the rotation speed, 00 C8(hex) = 200(dec); the speed unit being 0.1 rpm &rArr; the rotation speed = 20 rpm (check our online <a href=\"https:\/\/blog.darwin-microfluidics.com\/base-converter-binary-octal-decimal-and-hexadecimal\/\">base conversion tool<\/a>)<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;to start the pump at normal speed<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;to run the pump clockwise<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">DB<\/span><\/span> as the XOR result of&nbsp;<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;(pump address),&nbsp;<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">06<\/span>&nbsp;(pdu length) and&nbsp;<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">58 4C 00 C8 01 01<\/span>&nbsp;(pdu)&nbsp;<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b0e490 elementor-widget elementor-widget-text-editor\" data-id=\"4b0e490\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Set the BT100-1L to run counter-clockwise at a flow rate of 3 mL\/min with a pump head DG (10 rollers) and a tubing ID of 0.25 mm<\/strong><\/li><\/ul><p><span style=\"font-weight: 400;\">Control command string:&nbsp;<\/span><span style=\"background-color: #cccccc; color: #000000; font-family: Arial, sans-serif; font-size: 12pt; white-space-collapse: preserve; letter-spacing: -0.01rem;\">E9 01 0A 57 4C 00 2D C6 C0 01 00 02 03 3B<\/span><\/p><ul><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">E9<\/span>&nbsp;as the flag<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">01<\/span><\/span> as the address 1 of the pump<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">0A<\/span><\/span> as the length of the pdu (<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">57 4C 00 2D C6 C0 01 00 02 03<\/span>)<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">57 4C<\/span><\/span> as command characters WL<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">00 2D C6 C0<\/span>&nbsp;refers to the flow rate, 00 2D C6 C0(hex) = 3000000(dec); the flow rate unit being nL\/min &rArr; the flow rate = 3000000 nL\/min = 3 mL\/min<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;to start the pump at normal speed<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">00<\/span>&nbsp;to run the pump counter-clockwise<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">02<\/span>&nbsp;for the DG (10 rollers) pump head<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">03<\/span>&nbsp;for the tubing ID of 0.25 mm<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">3B<\/span><\/span> as the XOR result of&nbsp;<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;(pump address),&nbsp;<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">0A<\/span>&nbsp;(pdu length) and <\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">57 4C 00 2D C6 C0 01 00 02 03<\/span>&nbsp;(pdu)&nbsp;<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8c5a916 elementor-widget elementor-widget-text-editor\" data-id=\"8c5a916\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em><strong>&#128680;<\/strong><strong>Do not hesitate to use our user-friendly online <a href=\"https:\/\/blog.darwin-microfluidics.com\/control-command-string-generator-for-longer-peristaltic-pumps\/\">command string generator<\/a> to effortlessly generate precise control command strings for your BT100-1L.<\/strong><\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-75a891b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"75a891b\" data-element_type=\"section\" data-e-type=\"section\" id=\"code\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-3dbf0f1\" data-id=\"3dbf0f1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-bc0cd3e elementor-widget elementor-widget-heading\" data-id=\"bc0cd3e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How to communicate with the BT100-1L using Matlab ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb1d432 elementor-widget elementor-widget-text-editor\" data-id=\"cb1d432\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Matlab code snippets showing how to open the serial port, write and send control command strings to the pump and write a simple pumping program are presented below.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-38e2ee8 elementor-widget elementor-widget-text-editor\" data-id=\"38e2ee8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>From the first example just presented above, the following Matlab code snippet makes the BT100-1L run clockwise at a rotational speed of 20 rpm.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-aff03ca elementor-widget elementor-widget-code-highlight\" data-id=\"aff03ca\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"code-highlight.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"prismjs-tomorrow copy-to-clipboard word-wrap\">\n\t\t\t<pre data-line=\"4,7,10,13\" class=\"highlight-height language-css line-numbers\">\n\t\t\t\t<code readonly class=\"language-css\">\n\t\t\t\t\t<xmp>%%% RUN PUMP 1, CLOCKWISE, AT A ROTATING SPEED OF 20 RPM\r\n\r\n% Open the serial port with the data format corresponding to the BT100-1L\r\ns = serialport('COM6', 1200, 'Parity', 'Even', 'DataBits', 8, 'StopBits', 1);\r\n\r\n% Write the corresponding control command string\r\nStr = 'E9 01 06 58 4C 00 C8 01 01 DB';\r\n\r\n% Read data from Str, convert it according to the format specified '%2x' (hexadecimal conversion), transpose and return the results in an array\r\nData = sscanf(Str, '%2x').';\r\n\r\n% Write the Data to the pump in the form of an unsigned integer 8bits\r\nwrite(s, Data, uint8);\r\n<\/xmp>\n\t\t\t\t<\/code>\n\t\t\t<\/pre>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e6d3b2a elementor-widget elementor-widget-text-editor\" data-id=\"e6d3b2a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>In a second code snippet, let&rsquo;s make the pump run clockwise at a rotating speed of 10 rpm for 10s, then make it run counter-clockwise at a rotating speed of 5 rpm for 30s before stopping it.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c27f18a elementor-widget elementor-widget-code-highlight\" data-id=\"c27f18a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"code-highlight.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"prismjs-tomorrow copy-to-clipboard word-wrap\">\n\t\t\t<pre data-line=\"\" class=\"highlight-height language-css line-numbers\">\n\t\t\t\t<code readonly class=\"language-css\">\n\t\t\t\t\t<xmp>%%% RUN PUMP 1 CLOCKWISE AT A ROTATING SPEED OF 10 RPM FOR 10s, THEN COUNTER&minus;CLOCKWISE AT A ROTATING SPEED OF 5 RPM FOR 30s BEFORE STOPPING IT\r\n\r\n% Open the serial port with the data format corresponding to the BT100-1L\r\ns = serialport('COM6', 1200, 'Parity', 'Even', 'DataBits', 8, 'StopBits', 1);\r\n\r\n% Run pump 1 clockwise at a rotating speed of 10 rpm for 10s\r\nStr = 'E9 01 06 58 4C 00 64 01 01 77'; % corresponding control command string\r\nData = sscanf(Str, '%2x').';\r\nwrite(s, Data, uint8); % write the Data to the pump\r\n\r\nPumping_time = 10;\r\nwhile Pumping_time &gt; 0\r\n    pause(1)\r\n    Pumping_time = Pumping_time &minus; 1;\r\n    disp(['Remaining_time:' num2str(Pumping_time)])\r\nend % 10s delay with a visible timer\r\n\r\n% Run pump 1 counter-clockwise at a rotating speed of 5 rpm for 30s\r\nStr = 'E9 01 06 58 4C 00 32 01 00 20'; % corresponding control command string\r\nData = sscanf(Str, '%2x').';\r\nwrite(s, Data, uint8); % write the Data to the pump\r\n\r\nPumping_time = 30;\r\nwhile Pumping_time &gt; 0\r\n    pause(1)\r\n    Pumping_time = Pumping_time &minus; 1;\r\n    disp(['Remaining_time:' num2str(Pumping_time)])\r\nend % 30s delay with a visible timer\r\n\r\n% Stop the pump\r\nStr = 'E9 01 06 58 4C 00 32 00 00 21'; % corresponding control command string; we took the previous command string and changed the State 1 byte from 01 (start the pump) to 00 (stop the pump) and of course computed the new fcs\r\nData = sscanf(Str, '%2x').';\r\nwrite(s, Data, uint8); % write the Data to the pump\r\n<\/xmp>\n\t\t\t\t<\/code>\n\t\t\t<\/pre>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-cb7ef29 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"cb7ef29\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f9bde8b\" data-id=\"f9bde8b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-d0e9117 elementor-widget elementor-widget-heading\" data-id=\"d0e9117\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a36b02e elementor-widget elementor-widget-text-editor\" data-id=\"a36b02e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>We hope this blog post has helped you understand how to control the Longer BT100-1L multichannel peristaltic pump remotely via Matlab using the LONGER RS485 protocol. You can also use other programming platforms such as Python to write and send control command strings to the pump and read and interpret the responses from the pump. For more details about this topic, check our blog post &ldquo;<a href=\"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/\"><b>How to Control the Longer BT100-1L Pump via Python ?<\/b><\/a><span style=\"font-weight: 400;\">&rdquo;.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-738cacd elementor-widget elementor-widget-text-editor\" data-id=\"738cacd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>If you have any questions or feedback, please feel free to contact us at <a href=\"https:\/\/darwin-microfluidics.com\/pages\/contact-us\"><span style=\"font-weight: 400;\">contact@darwin-microfluidics.com<\/span><\/a><span style=\"font-weight: 400;\">.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5bf994e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5bf994e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-1749d67\" data-id=\"1749d67\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e6db298 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"e6db298\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Need some help with your microfluidic project?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/contact-us\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Contact our experts!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Need some help with your microfluidic project?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>We can make microfluidics easy for you!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6e4747e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6e4747e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-944cbdc\" data-id=\"944cbdc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap\">\n\t\t\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>If you are looking for a precision peristaltic pump that can handle multiple channels simultaneously (up to 24), you might want to check out the Longer BT100-1L. This pump can deliver flow rates ranging from 2 &micro;L\/min to 366.7 mL\/min&hellip;<\/p>\n","protected":false},"author":4,"featured_media":17368,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[24,33],"tags":[],"class_list":["post-17362","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-control","category-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to Control the Longer BT100-1L Pump via Matlab ?<\/title>\n<meta name=\"description\" content=\"Use Matlab to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to Control the Longer BT100-1L Pump via Matlab ?\" \/>\n<meta property=\"og:description\" content=\"Use Matlab to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2024-02-13T17:04:04+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:14:10+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L.png\" \/>\n\t<meta property=\"og:image:width\" content=\"981\" \/>\n\t<meta property=\"og:image:height\" content=\"938\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Elia Missi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"How to Control the Longer BT100-1L Pump via Matlab ?\",\"datePublished\":\"2024-02-13T17:04:04+00:00\",\"dateModified\":\"2026-11-19T14:14:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/\"},\"wordCount\":1465,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/BT-100L.png\",\"articleSection\":[\"Flow control\",\"Guides &amp; tutorials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/\",\"name\":\"How to Control the Longer BT100-1L Pump via Matlab ?\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/BT-100L.png\",\"datePublished\":\"2024-02-13T17:04:04+00:00\",\"dateModified\":\"2026-11-19T14:14:10+00:00\",\"description\":\"Use Matlab to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/BT-100L.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/BT-100L.png\",\"width\":981,\"height\":938,\"caption\":\"An image of a Longer BT100-1L peristaltic pump without background\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-matlab\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Control the Longer BT100-1L Pump via Matlab ?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/eliamissi\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Control the Longer BT100-1L Pump via Matlab ?","description":"Use Matlab to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/","og_locale":"en_US","og_type":"article","og_title":"How to Control the Longer BT100-1L Pump via Matlab ?","og_description":"Use Matlab to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.","og_url":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-02-13T17:04:04+00:00","article_modified_time":"2026-11-19T14:14:10+00:00","og_image":[{"width":981,"height":938,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L.png","type":"image\/png"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/"},"author":{"name":"Elia Missi","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/c80a1276036340d7e994346f251af8f5"},"headline":"How to Control the Longer BT100-1L Pump via Matlab ?","datePublished":"2024-02-13T17:04:04+00:00","dateModified":"2026-11-19T14:14:10+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/"},"wordCount":1465,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L.png","articleSection":["Flow control","Guides &amp; tutorials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/","url":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/","name":"How to Control the Longer BT100-1L Pump via Matlab ?","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L.png","datePublished":"2024-02-13T17:04:04+00:00","dateModified":"2026-11-19T14:14:10+00:00","description":"Use Matlab to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L.png","width":981,"height":938,"caption":"An image of a Longer BT100-1L peristaltic pump without background"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"How to Control the Longer BT100-1L Pump via Matlab ?"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/eliamissi\/"}]}},"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L.png","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/17362","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=17362"}],"version-history":[{"count":195,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/17362\/revisions"}],"predecessor-version":[{"id":33703,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/17362\/revisions\/33703"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/17368"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=17362"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=17362"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=17362"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}