{"id":18628,"date":"2024-03-01T11:08:22","date_gmt":"2024-03-01T10:08:22","guid":{"rendered":"https:\/\/blog.darwin-microfluidics.com\/?p=18628"},"modified":"2026-11-19T15:14:14","modified_gmt":"2026-11-19T14:14:14","slug":"how-to-control-the-longer-bt100-1l-pump-via-python","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/","title":{"rendered":"How to control the Longer BT100-1L pump via Python ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"18628\" class=\"elementor elementor-18628\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-733a621 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"733a621\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e953261\" data-id=\"e953261\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b6a33c5 elementor-widget elementor-widget-text-editor\" data-id=\"b6a33c5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>If you are looking for a <strong>precision peristaltic pump<\/strong> that can handle multiple channels simultaneously (up to 24), you might want to check out the <strong>Longer <a href=\"https:\/\/darwin-microfluidics.com\/products\/microfluidic-2-24-channel-peristaltic-pump?variant=43791085273323\">BT100-1L<\/a><\/strong>. This pump can deliver flow rates ranging from 2 &micro;L\/min to 366.7 mL\/min depending on the number of rollers in the pump head. It is also a relatively cheap peristaltic pump that has a wide range of applications.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0bc160a elementor-widget elementor-widget-text-editor\" data-id=\"0bc160a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The BT100-1L can be controlled remotely from your computer which can give you more flexibility and convenience, especially if you want to run complex pumping programs with loops, pauses, and varying flow rates.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e0cfdeb elementor-widget elementor-widget-text-editor\" data-id=\"e0cfdeb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In this blog post, we will show you how to communicate with the BT100-1L using the <strong>LONGER RS485 protocol<\/strong>, which is a serial communication protocol that allows you to send commands and receive responses from the pump. We will also provide some examples and <a href=\"#code\">code snippets<\/a> on how to use <strong>Python<\/strong> to write and send control command strings to the pump.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6a84c95 elementor-toc--content-ellipsis elementor-toc--minimized-on-tablet elementor-widget elementor-widget-table-of-contents\" data-id=\"6a84c95\" data-element_type=\"widget\" data-e-type=\"widget\" data-settings='{\"exclude_headings_by_selector\":\"#cta1, #cta2\",\"headings_by_tags\":[\"h2\",\"h3\"],\"marker_view\":\"numbers\",\"no_headings_message\":\"No headings were found on this page.\",\"minimize_box\":\"yes\",\"minimized_on\":\"tablet\",\"hierarchical_view\":\"yes\",\"min_height\":{\"unit\":\"px\",\"size\":\"\",\"sizes\":[]},\"min_height_tablet\":{\"unit\":\"px\",\"size\":\"\",\"sizes\":[]},\"min_height_mobile\":{\"unit\":\"px\",\"size\":\"\",\"sizes\":[]}}' data-widget_type=\"table-of-contents.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__header\">\n\t\t\t\t\t\t<h4 class=\"elementor-toc__header-title\">\n\t\t\t\tTABLE OF CONTENTS\t\t\t<\/h4>\n\t\t\t\t\t\t\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--expand\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__6a84c95\" aria-expanded=\"true\" aria-label=\"Open table of contents\"><i aria-hidden=\"true\" class=\"fas fa-chevron-down\"><\/i><\/div>\n\t\t\t\t<div class=\"elementor-toc__toggle-button elementor-toc__toggle-button--collapse\" role=\"button\" tabindex=\"0\" aria-controls=\"elementor-toc__6a84c95\" aria-expanded=\"true\" aria-label=\"Close table of contents\"><i aria-hidden=\"true\" class=\"fas fa-chevron-up\"><\/i><\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<div id=\"elementor-toc__6a84c95\" class=\"elementor-toc__body\">\n\t\t\t<div class=\"elementor-toc__spinner-container\">\n\t\t\t\t<i class=\"elementor-toc__spinner eicon-animation-spin eicon-loading\" aria-hidden=\"true\"><\/i>\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-64e32d5 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"64e32d5\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-755ff6f\" data-id=\"755ff6f\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b9371d5 elementor-widget elementor-widget-heading\" data-id=\"b9371d5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">What do you need to communicate with the BT100-1L ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ee0ce84 elementor-widget elementor-widget-text-editor\" data-id=\"ee0ce84\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>To communicate with the BT100-1L using the LONGER RS485 protocol, you will need the following:<\/p><ul><li>A BT100-1L pump with a <a href=\"https:\/\/darwin-microfluidics.com\/collections\/peristaltic-pump-heads\">pump head<\/a> and a <a href=\"https:\/\/darwin-microfluidics.com\/collections\/peristaltic-pump-tubing\">tubing<\/a> of your choice<\/li><li>A RS485 <a href=\"https:\/\/darwin-microfluidics.com\/collections\/peristaltic-pump-accessories\/products\/external-control-module-for-longer-pumps\">control module<\/a> that plugs into the DB15 port on the rear of the pump<\/li><li>A <a href=\"https:\/\/darwin-microfluidics.com\/products\/usb-to-rs485-serial-converter-cable\/\">serial cable<\/a> that connects the RS485 control module to your computer or device<\/li><li>A programming platform (Python in the case herein)<\/li><li>A basic understanding of the data format, command format, and pdu format of the LONGER RS485 protocol (explained below <a href=\"#pdu\">&#128071;<\/a>)<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-193b049 elementor-widget elementor-widget-global elementor-global-18316 elementor-widget-pix-promo-box\" data-id=\"193b049\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta1\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Tubing_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"LOOKING FOR FLEXIBILITY IN TUBING OPTIONS?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/collections\/microfluidic-tubings\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Discover our selection!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">LOOKING FOR FLEXIBILITY IN TUBING OPTIONS?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Explore our microfluidic tubing solutions for reliable and efficient flow in your experiments!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4cc1021 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4cc1021\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-f2ab0fc\" data-id=\"f2ab0fc\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-29e1252 elementor-widget elementor-widget-heading\" data-id=\"29e1252\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How to Set Up the Communication Port ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3971d9c elementor-widget elementor-widget-text-editor\" data-id=\"3971d9c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Before you can start sending and receiving data from the pump, you need to set up the communication port correctly. Here are the steps to follow:\n<\/p><ul>\n \t<li>Connect the DB15 connector to the DB15 port on the rear of the pump<\/li>\n \t<li>Turn on the pump and press the adjusting knob on the pump front to enter the remote control setting interface and enable remote control mode &#128377;&#65039;<\/li>\n \t<li>Make sure the communication parameters on your programming platform match the ones of the BT100-1L, which are:\n<ul>\n \t<li>1 start bit<\/li>\n \t<li>8 data bits<\/li>\n \t<li>1 even parity<\/li>\n \t<li>1 stop bit<\/li>\n \t<li>a baud rate of 1200 bits\/s<\/li>\n<\/ul>\n<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-3c65bb9 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"3c65bb9\" data-element_type=\"section\" data-e-type=\"section\" id=\"pdu\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e09d962\" data-id=\"e09d962\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-112bc19 elementor-widget elementor-widget-heading\" data-id=\"112bc19\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How to Write Control Command Strings to the BT100-1L ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d668144 elementor-widget elementor-widget-text-editor\" data-id=\"d668144\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Once you have set up the communication port, you can start writing and sending control command strings to the pump. A control command string is a sequence of hexadecimal characters that follows a specific format, which consists of:\n<\/p><ul>\n \t<li><span style=\"font-weight: 400;\">a start flag (E9H)<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">a pump address (1 to 30, or 31 for broadcast)<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">a length of the pdu (protocol data unit)<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">a pdu, which contains the command characters and the parameters for the desired application<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">a frame check sequence (fcs), which is obtained by calculating the XOR of the pump address, the length of the pdu, and the pdu itself&nbsp;<\/span>(compute your fcs using our online <a href=\"https:\/\/blog.darwin-microfluidics.com\/frame-check-sequence-xor-calculator-for-longer-pump-control\/\">frame check sequence XOR calculator<\/a>)<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0d8c1d9 elementor-widget elementor-widget-text-editor\" data-id=\"0d8c1d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The pdu and its length depend on the application requested from the pump. Some of the common applications are:\n<\/p><ul>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Set running parameter (rotation speed)<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Read running parameter (rotation speed)<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Set running parameter (flow rate) with pump head and tube<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Read running parameter (flow rate) with pump head and tube<\/span><\/li>\n \t<li style=\"font-weight: 400;\"><span style=\"font-weight: 400;\">Flow calibration<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-00cf7db elementor-widget elementor-widget-text-editor\" data-id=\"00cf7db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>For each application, there is a corresponding set of command characters and parameters that you need to include in the pdu. These parameters are detailed below.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fa4d1be elementor-widget elementor-widget-heading\" data-id=\"fa4d1be\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Set running parameter (rotation speed)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55b2d55 elementor-widget elementor-widget-text-editor\" data-id=\"55b2d55\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This application consists of writing to the pump. The overall length of the pdu is <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">6 bytes<\/span> where the control command string consists of (in the exact same order):<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8628a65 elementor-widget elementor-widget-shortcode\" data-id=\"8628a65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-1\" class=\"tablepress tablepress-id-1\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">XL<\/td><td class=\"column-2\">Set Speed<\/td><td class=\"column-3\">State 1<\/td><td class=\"column-4\">State 2<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">2 bytes<\/td><td class=\"column-2\">2 bytes<\/td><td class=\"column-3\">1 byte<\/td><td class=\"column-4\">1 byte<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-1 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5770870 elementor-widget elementor-widget-text-editor\" data-id=\"5770870\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>XL, control command string of <span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 bytes<\/span>, 58 4C<\/li>\n \t<li>Set speed (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 bytes<\/span>) with a speed unit of 0.1 rpm and a maximum speed of 100 rpm (03 E8)<\/li>\n \t<li>State 1 (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span>):&nbsp;\n<ul>\n \t<li>bit 0 &ndash; start\/stop bit where 1 is to start the pump and 0 is to stop it<\/li>\n \t<li>bit 1 &ndash; prime bit where 1 is to prime the pump at the max speed of 100 rpm and 0 is to run the pump at a normal speed<\/li>\n<\/ul>\n<\/li>\n \t<li>State 2 (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span>):\n<ul>\n \t<li>bit 0 &ndash; sets the&nbsp;rotation&nbsp;direction where 1 is for clockwise and 0 is for counter-clockwise<\/li>\n<\/ul>\n<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5081030 elementor-widget elementor-widget-text-editor\" data-id=\"5081030\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The pump will respond with <span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">XL<\/span><\/span><span style=\"font-weight: 400;\">&nbsp;and will display on its front screen the rotation speed and the direction of rotation after receiving the control command string.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-905d492 elementor-widget elementor-widget-heading\" data-id=\"905d492\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Read running parameter (rotation speed)<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a8865ed elementor-widget elementor-widget-text-editor\" data-id=\"a8865ed\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This application consists of reading from the pump. The overall length of the pdu is <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">2 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\"> where the control command string is <\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; vertical-align: baseline; white-space-collapse: preserve; background-color: #cccccc;\"><span style=\"color: #111111;\">DL<\/span><\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\">.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3f13140 elementor-widget elementor-widget-text-editor\" data-id=\"3f13140\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The pump&rsquo;s response consists of:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-968dce0 elementor-widget elementor-widget-shortcode\" data-id=\"968dce0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-2\" class=\"tablepress tablepress-id-2\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">DL<\/td><td class=\"column-2\">Show Speed<\/td><td class=\"column-3\">State 1<\/td><td class=\"column-4\">State 2<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">2 bytes<\/td><td class=\"column-2\">2 bytes<\/td><td class=\"column-3\">1 byte<\/td><td class=\"column-4\">1 byte<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-2 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-856f5e5 elementor-widget elementor-widget-text-editor\" data-id=\"856f5e5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>DL, control command string of <span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">, 44 4C<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-98400f1 elementor-widget elementor-widget-heading\" data-id=\"98400f1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Set running parameter (flow rate) with pump head and tube<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e1eaa7f elementor-widget elementor-widget-text-editor\" data-id=\"e1eaa7f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This application consists of writing to the pump. The overall length of the pdu is <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">10 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\"> where the control command string consists of:<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-350aee9 elementor-widget-mobile__width-auto elementor-widget elementor-widget-shortcode\" data-id=\"350aee9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-8\" class=\"tablepress tablepress-id-8\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">WL<\/td><td class=\"column-2\">2 bytes<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Set flow rate<\/td><td class=\"column-2\">4 bytes<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">State 1<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">State 2<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Pump head number<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Tube number<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-8 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4ea83b3 elementor-widget elementor-widget-text-editor\" data-id=\"4ea83b3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>WL, control command string of <span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">, 57 4C<\/span><\/li>\n \t<li>Set flow rate (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">4 bytes<\/span><span style=\"font-weight: 400;\">) with a nL\/min flow rate unit<\/span><\/li>\n \t<li>State 1 (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span><span style=\"font-weight: 400;\">) and State 2 (<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span><\/span><span style=\"font-weight: 400;\">) as already explained&nbsp;<\/span><\/li>\n \t<li>Pump head number (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span><span style=\"font-weight: 400;\">), as presented in the tables below:<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4768567 elementor-widget-mobile__width-auto elementor-widget elementor-widget-shortcode\" data-id=\"4768567\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-11\" class=\"tablepress tablepress-id-11\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Pump head<\/th><th class=\"column-2\">Characters<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">DG (6 rollers)<\/td><td class=\"column-2\">01<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">DG (10 rollers)<\/td><td class=\"column-2\">02<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">YZ1515\/YZ2515<\/td><td class=\"column-2\">03<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">313D<\/td><td class=\"column-2\">04<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">DG15<\/td><td class=\"column-2\">05<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-11 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3295ea7 elementor-widget elementor-widget-text-editor\" data-id=\"3295ea7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>Tube number (<span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">1 byte<\/span><span style=\"font-weight: 400;\">), as presented in the table below:<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e959793 elementor-widget-mobile__width-auto elementor-widget elementor-widget-shortcode\" data-id=\"e959793\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-12\" class=\"tablepress tablepress-id-12\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Tubing ID (mm)<br>\n01: DG (6 rollers)<br>\n02: DG (10 rollers)<br>\n05: DG15<\/th><th class=\"column-2\">Tube number<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">0.13<\/td><td class=\"column-2\">01<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">0.19<\/td><td class=\"column-2\">02<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">0.25<\/td><td class=\"column-2\">03<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">0.38<\/td><td class=\"column-2\">04<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">0.44<\/td><td class=\"column-2\">05<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">0.51<\/td><td class=\"column-2\">06<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">0.57<\/td><td class=\"column-2\">07<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">0.64<\/td><td class=\"column-2\">08<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">0.76<\/td><td class=\"column-2\">09<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">0.89<\/td><td class=\"column-2\">10<\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">0.95<\/td><td class=\"column-2\">11<\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">1.02<\/td><td class=\"column-2\">12<\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">1.09<\/td><td class=\"column-2\">13<\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">1.14<\/td><td class=\"column-2\">14<\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">1.22<\/td><td class=\"column-2\">15<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">1.30<\/td><td class=\"column-2\">16<\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">1.42<\/td><td class=\"column-2\">17<\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">1.54<\/td><td class=\"column-2\">18<\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">1.65<\/td><td class=\"column-2\">19<\/td>\n<\/tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">1.75<\/td><td class=\"column-2\">20<\/td>\n<\/tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">1.85<\/td><td class=\"column-2\">21<\/td>\n<\/tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">2.06<\/td><td class=\"column-2\">22<\/td>\n<\/tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">2.29<\/td><td class=\"column-2\">23<\/td>\n<\/tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">2.54<\/td><td class=\"column-2\">24<\/td>\n<\/tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">2.79<\/td><td class=\"column-2\">25<\/td>\n<\/tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">3.17<\/td><td class=\"column-2\">26<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-12 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7fe8c94 elementor-widget-mobile__width-auto elementor-widget elementor-widget-shortcode\" data-id=\"7fe8c94\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-13\" class=\"tablepress tablepress-id-13\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Tubing ID (mm)<br>\n3: YZ1515\/YZ2515<br>\n4: 313D<\/th><th class=\"column-2\">Characters<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">0.8<\/td><td class=\"column-2\">01<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">1.6<\/td><td class=\"column-2\">02<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">2.4<\/td><td class=\"column-2\">03<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">3.1<\/td><td class=\"column-2\">04<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">4.8<\/td><td class=\"column-2\">05<\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">6.4<\/td><td class=\"column-2\">06<\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">7.9<\/td><td class=\"column-2\">07<\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">9.6<\/td><td class=\"column-2\">08<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-13 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5638678 elementor-widget elementor-widget-text-editor\" data-id=\"5638678\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The pump will respond with <span style=\"font-size: 12pt; font-family: Arial, sans-serif; vertical-align: baseline;\"><span style=\"color: #111111;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">WL<\/span><\/span><\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; vertical-align: baseline;\"><span style=\"color: #000000;\">&nbsp;<\/span><\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">Show flow rate (<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">4 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">)<\/span> and will display <span style=\"font-weight: 400;\">on its front screen the flow rate, the corresponding rotation speed and the direction of rotation after receiving the control command string.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6cc4508 elementor-widget elementor-widget-heading\" data-id=\"6cc4508\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Read running parameter (flow rate) with pump head and tube<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c2524df elementor-widget elementor-widget-text-editor\" data-id=\"c2524df\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This application consists of reading from the pump. The overall length of the pdu is <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">2 bytes<\/span> where the control command string is <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: transparent; vertical-align: baseline;\"><span style=\"color: #111111; letter-spacing: -0.16px; white-space-collapse: preserve; background-color: #cccccc;\">RL<\/span>.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f9810ea elementor-widget elementor-widget-text-editor\" data-id=\"f9810ea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>The pump&rsquo;s response consists of:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1a133e4 elementor-widget elementor-widget-shortcode\" data-id=\"1a133e4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-10\" class=\"tablepress tablepress-id-10\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">RL<\/td><td class=\"column-2\">2 bytes<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Show flow rate<\/td><td class=\"column-2\">4 bytes<\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">State 1<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">State 2<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Pump head number<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Tube number<\/td><td class=\"column-2\">1 byte<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-10 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e5064a0 elementor-widget elementor-widget-text-editor\" data-id=\"e5064a0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>RL, control command string of <span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #ff0000; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">2 bytes<\/span><span style=\"font-size: 12pt; font-family: Arial,sans-serif; color: #111111; background-color: transparent; font-weight: 400; font-style: normal; font-variant: normal; text-decoration: none; vertical-align: baseline;\">, 52 4C<\/span><\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-fee9560 elementor-widget elementor-widget-heading\" data-id=\"fee9560\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Flow calibration<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c39dc6 elementor-widget elementor-widget-text-editor\" data-id=\"2c39dc6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>This application consists of writing to the pump. The overall length of the pdu is <span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #ff0000; background-color: transparent; vertical-align: baseline;\">6 bytes<\/span> where the control command string consists of:<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5d088b1 elementor-widget elementor-widget-shortcode\" data-id=\"5d088b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-7\" class=\"tablepress tablepress-id-7\">\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-1\">\n\t<td class=\"column-1\">CL<\/td><td class=\"column-2\">Test flow rate<\/td>\n<\/tr>\n<tr class=\"row-2\">\n\t<td class=\"column-1\">2 bytes<\/td><td class=\"column-2\">4 bytes<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-7 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ec624d elementor-widget elementor-widget-text-editor\" data-id=\"1ec624d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li dir=\"ltr\" style=\"line-height: 1.38\" role=\"presentation\"><span style=\"font-size: 12pt;font-family: Arial,sans-serif;color: #111111;background-color: transparent;font-weight: 400;font-style: normal;font-variant: normal;text-decoration: none;vertical-align: baseline\">CL, control command string of <\/span><span style=\"font-size: 12pt;font-family: Arial,sans-serif;color: #ff0000;background-color: transparent;font-weight: 400;font-style: normal;font-variant: normal;text-decoration: none;vertical-align: baseline\">2 bytes<\/span><span style=\"font-size: 12pt;font-family: Arial,sans-serif;color: #111111;background-color: transparent;font-weight: 400;font-style: normal;font-variant: normal;text-decoration: none;vertical-align: baseline\">, 43 4C<\/span><\/li><li dir=\"ltr\" style=\"line-height: 1.38\" role=\"presentation\"><span style=\"font-weight: 400\">Test flow rate (<span style=\"font-size: 12pt;font-family: Arial,sans-serif;color: #ff0000;background-color: transparent;font-weight: 400;font-style: normal;font-variant: normal;text-decoration: none;vertical-align: baseline\">4 bytes<\/span><\/span><span style=\"font-weight: 400\">) with a nL\/min flow rate unit<\/span><\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9331e1a elementor-widget elementor-widget-heading\" data-id=\"9331e1a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Examples of control command strings<\/h3>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3472b37 elementor-widget elementor-widget-text-editor\" data-id=\"3472b37\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Set the BT100-1L to run clockwise at a rotating speed of 20 rpm<\/strong><\/li><\/ul><p><span style=\"font-weight: 400;\">Control command string:&nbsp;<\/span><span style=\"background-color: #cccccc; color: #000000; font-family: Arial, sans-serif; font-size: 12pt; white-space-collapse: preserve; letter-spacing: -0.01rem;\">E9 01 06 58 4C 00 C8 01 01 DB<\/span><\/p><ul><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">E9<\/span>&nbsp;as the flag<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;as the address 1 of the pump<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">06<\/span>&nbsp;as the length of the pdu (<span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">58 4C 00 C8 01 01<\/span><\/span><\/span><span style=\"font-weight: 400;\">)<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">58 4C<\/span><\/span> as command characters XL<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">00 C8<\/span>&nbsp;refers to the rotation speed, 00 C8(hex) = 200(dec); the speed unit being 0.1 rpm &rArr; the rotation speed = 20 rpm&nbsp;<\/span>(check our online&nbsp;<a style=\"background-color: #ffffff; font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: 400; letter-spacing: -0.16px;\" href=\"https:\/\/blog.darwin-microfluidics.com\/base-converter-binary-octal-decimal-and-hexadecimal\/\">base conversion tool<\/a><span style=\"letter-spacing: -0.16px;\">)<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;to start the pump at normal speed<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;to run the pump clockwise<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">DB<\/span><\/span> as the XOR result of&nbsp;<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;(pump address),&nbsp;<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">06<\/span>&nbsp;(pdu length) and&nbsp;<\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">58 4C 00 C8 01 01<\/span>&nbsp;(pdu)&nbsp;<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4bf297d elementor-widget elementor-widget-text-editor\" data-id=\"4bf297d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li><strong>Set the BT100-1L to run counter-clockwise at a flow rate of 3 mL\/min with a pump head DG (10 rollers) and a tubing ID of 0.25 mm<\/strong><\/li><\/ul><p><span style=\"font-weight: 400;\">Control command string:&nbsp;<\/span><span style=\"background-color: #cccccc; color: #000000; font-family: Arial, sans-serif; font-size: 12pt; white-space-collapse: preserve; letter-spacing: -0.01rem;\">E9 01 0A 57 4C 00 2D C6 C0 01 00 02 03 3B<\/span><\/p><ul><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">E9<\/span>&nbsp;as the flag<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">01<\/span><\/span> as the address 1 of the pump<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">0A<\/span><\/span> as the length of the pdu (<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">57 4C 00 2D C6 C0 01 00 02 03<\/span>)<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">57 4C<\/span><\/span> as command characters WL<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">00 2D C6 C0<\/span>&nbsp;refers to the flow rate, 00 2D C6 C0(hex) = 3000000(dec); the flow rate unit being nL\/min &rArr; the flow rate = 3000000 nL\/min = 3 mL\/min<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;to start the pump at normal speed<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">00<\/span>&nbsp;to run the pump counter-clockwise<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">02<\/span>&nbsp;for the DG (10 rollers) pump head<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">03<\/span>&nbsp;for the tubing ID of 0.25 mm<\/span><\/li><li><span style=\"font-weight: 400;\"><span style=\"color: #111111; font-family: Arial, sans-serif;\"><span style=\"white-space-collapse: preserve; background-color: #cccccc;\">3B<\/span><\/span> as the XOR result of&nbsp;<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">01<\/span>&nbsp;(pump address),&nbsp;<\/span><span style=\"font-weight: 400;\"><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #111111; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">0A<\/span>&nbsp;(pdu length) and <\/span><span style=\"font-size: 12pt; font-family: Arial, sans-serif; color: #000000; background-color: #cccccc; font-variant-numeric: normal; font-variant-east-asian: normal; font-variant-alternates: normal; font-variant-position: normal; vertical-align: baseline; white-space-collapse: preserve;\">57 4C 00 2D C6 C0 01 00 02 03<\/span>&nbsp;(pdu)&nbsp;<\/li><\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-04cf3b7 elementor-widget elementor-widget-text-editor\" data-id=\"04cf3b7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em><strong>&#128680;<\/strong><strong>Do not hesitate to use our user-friendly online <a href=\"https:\/\/blog.darwin-microfluidics.com\/control-command-string-generator-for-longer-peristaltic-pumps\/\">command string generator<\/a> to effortlessly generate precise control command strings for your BT100-1L.<\/strong><\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-9a0f2c8 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"9a0f2c8\" data-element_type=\"section\" data-e-type=\"section\" id=\"code\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-55cbd4b\" data-id=\"55cbd4b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8c4a135 elementor-widget elementor-widget-heading\" data-id=\"8c4a135\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">How to communicate with the BT100-1L using Python ?<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-59b1257 elementor-widget elementor-widget-text-editor\" data-id=\"59b1257\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Python code snippets showing how to open the serial port, write and send control command strings to the pump and write a simple pumping program are presented below.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b2da58c elementor-widget elementor-widget-text-editor\" data-id=\"b2da58c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>From the first example just presented above, the following Python code snippet makes the BT100-1L run clockwise at a rotational speed of 20 rpm.<\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef5b020 elementor-widget elementor-widget-code-highlight\" data-id=\"ef5b020\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"code-highlight.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"prismjs-tomorrow copy-to-clipboard word-wrap\">\n\t\t\t<pre data-line=\"4,7,10,13\" class=\"highlight-height language-python line-numbers\">\n\t\t\t\t<code readonly class=\"language-python\">\n\t\t\t\t\t<xmp>### RUN PUMP 1, CLOCKWISE, AT A ROTATING SPEED OF 20 RPM\r\n\r\n# To use the pySerial package\r\nimport serial\r\n\r\n# Open the serial port with the data format corresponding to the BT100-1L\r\nser = serial.Serial('COM6', 1200, parity=serial.PARITY_EVEN, bytesize=8, stopbits=1, timeout=None, xonxoff=0, rtscts=0)\r\n\r\n# Write the corresponding control command string in hexadecimal\r\nData = bytearray(b'\\xE9\\x01\\x06\\x58\\x4C\\x00\\xC8\\x01\\x01\\xDB')\r\n\r\n# Write the Data to the pump\r\nser.write(Data)\r\n<\/xmp>\n\t\t\t\t<\/code>\n\t\t\t<\/pre>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-dbe0150 elementor-widget elementor-widget-text-editor\" data-id=\"dbe0150\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>In a second code snippet, let&rsquo;s make the pump run clockwise at a rotating speed of 10 rpm for 10s, then make it run counter-clockwise at a rotating speed of 5 rpm for 30s before stopping it.<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a712ff2 elementor-widget elementor-widget-code-highlight\" data-id=\"a712ff2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"code-highlight.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"prismjs-tomorrow copy-to-clipboard word-wrap\">\n\t\t\t<pre data-line=\"\" class=\"highlight-height language-python line-numbers\">\n\t\t\t\t<code readonly class=\"language-python\">\n\t\t\t\t\t<xmp>### RUN PUMP 1 CLOCKWISE AT A ROTATING SPEED OF 10 RPM FOR 10s, THEN COUNTER&minus;CLOCKWISE AT A ROTATING SPEED OF 5 RPM FOR 30s BEFORE STOPPING IT\r\n\r\n# To use the pySerial package\r\nimport serial\r\n\r\n# To use the time package\r\nimport time\r\n\r\n# Open the serial port with the data format corresponding to the BT100-1L\r\nser = serial.Serial('COM6', 1200, parity=serial.PARITY_EVEN, bytesize=8, stopbits=1, timeout=None, xonxoff=0, rtscts=0)\r\n\r\n# Run pump 1 clockwise at a rotating speed of 10 rpm for 10s\r\nData = bytearray(b'\\xE9\\x01\\x06\\x58\\x4C\\x00\\x64\\x01\\x01\\x77') # corresponding control command string in hexadecimal\r\nser.write(Data) # write the Data to the pump\r\n\r\nPumping_time = 10;\r\nwhile Pumping_time &gt; 0:\r\n    print(Pumping_time)\r\n    time.sleep(1)\r\n    Pumping_time = Pumping_time &minus; 1\r\nend # 10s delay with a visible timer\r\n\r\n# Run pump 1 counter-clockwise at a rotating speed of 5 rpm for 30s\r\nData = bytearray(b'\\xE9\\x01\\x06\\x58\\x4C\\x00\\x32\\x01\\x00\\x20') \r\nser.write(Data) # write the Data to the pump\r\n\r\nPumping_time = 30;\r\nwhile Pumping_time &gt; 0:\r\n    print(Pumping_time)\r\n    time.sleep(1)\r\n    Pumping_time = Pumping_time &minus; 1\r\nend # 30s delay with a visible timer\r\n\r\n\r\n# Stop the pump\r\nData = bytearray(b'\\xE9\\x01\\x06\\x58\\x4C\\x00\\x32\\x00\\x00\\x21') # corresponding control command string in hexadecimal: we took the previous command string and changed the State 1 byte from 01 (start the pump) to 00 (stop the pump) and of course computed the new fcs\r\nser.write(Data) # write the Data to the pump\r\n<\/xmp>\n\t\t\t\t<\/code>\n\t\t\t<\/pre>\n\t\t<\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-867f7c9 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"867f7c9\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-abd3b68\" data-id=\"abd3b68\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0453ca5 elementor-widget elementor-widget-heading\" data-id=\"0453ca5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusion<\/h2>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ee479a elementor-widget elementor-widget-text-editor\" data-id=\"7ee479a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>We hope this blog post has helped you understand how to control the Longer BT100-1L multichannel peristaltic pump remotely via Python using the LONGER RS485 protocol. You can also use other programming platforms such as Matlab to write and send control command strings to the pump and read and interpret the responses from the pump. For more details about this topic, check our blog post &ldquo;<a href=\"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-matlab\/\"><b>How to Control the Longer BT100-1L Pump via Matlab ?<\/b><\/a><span style=\"font-weight: 400;\">&rdquo;.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-158fe8d elementor-widget__width-initial elementor-widget elementor-widget-text-editor\" data-id=\"158fe8d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>If you have any questions or feedback, please feel free to contact us at <a href=\"https:\/\/darwin-microfluidics.com\/pages\/contact-us\"><span style=\"font-weight: 400;\">contact@darwin-microfluidics.com<\/span><\/a><span style=\"font-weight: 400;\">.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-65bef03 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"65bef03\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-10c7b63\" data-id=\"10c7b63\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-7278c00 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"7278c00\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Need some help with your microfluidic project?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/contact-us\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Contact our experts!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Need some help with your microfluidic project?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>We can make microfluidics easy for you!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>If you are looking for a precision peristaltic pump that can handle multiple channels simultaneously (up to 24), you might want to check out the Longer BT100-1L. This pump can deliver flow rates ranging from 2 &micro;L\/min to 366.7 mL\/min&hellip;<\/p>\n","protected":false},"author":4,"featured_media":18629,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[24,33],"tags":[],"class_list":["post-18628","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-control","category-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>How to control the Longer BT100-1L pump via Python ? - Darwin Microfluidics<\/title>\n<meta name=\"description\" content=\"Use Python to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"How to control the Longer BT100-1L pump via Python ? - Darwin Microfluidics\" \/>\n<meta property=\"og:description\" content=\"Use Python to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2024-03-01T10:08:22+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:14:14+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L-1.png\" \/>\n\t<meta property=\"og:image:width\" content=\"981\" \/>\n\t<meta property=\"og:image:height\" content=\"938\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/png\" \/>\n<meta name=\"author\" content=\"Elia Missi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"8 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"How to control the Longer BT100-1L pump via Python ?\",\"datePublished\":\"2024-03-01T10:08:22+00:00\",\"dateModified\":\"2026-11-19T14:14:14+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/\"},\"wordCount\":1465,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/BT-100L-1.png\",\"articleSection\":[\"Flow control\",\"Guides &amp; tutorials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/\",\"name\":\"How to control the Longer BT100-1L pump via Python ? - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/BT-100L-1.png\",\"datePublished\":\"2024-03-01T10:08:22+00:00\",\"dateModified\":\"2026-11-19T14:14:14+00:00\",\"description\":\"Use Python to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/BT-100L-1.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/BT-100L-1.png\",\"width\":981,\"height\":938,\"caption\":\"An image of a Longer BT100-1L peristaltic pump without background\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/how-to-control-the-longer-bt100-1l-pump-via-python\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to control the Longer BT100-1L pump via Python ?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/eliamissi\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"How to control the Longer BT100-1L pump via Python ? - Darwin Microfluidics","description":"Use Python to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/","og_locale":"en_US","og_type":"article","og_title":"How to control the Longer BT100-1L pump via Python ? - Darwin Microfluidics","og_description":"Use Python to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.","og_url":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-03-01T10:08:22+00:00","article_modified_time":"2026-11-19T14:14:14+00:00","og_image":[{"width":981,"height":938,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L-1.png","type":"image\/png"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"8 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/"},"author":{"name":"Elia Missi","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/c80a1276036340d7e994346f251af8f5"},"headline":"How to control the Longer BT100-1L pump via Python ?","datePublished":"2024-03-01T10:08:22+00:00","dateModified":"2026-11-19T14:14:14+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/"},"wordCount":1465,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L-1.png","articleSection":["Flow control","Guides &amp; tutorials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/","url":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/","name":"How to control the Longer BT100-1L pump via Python ? - Darwin Microfluidics","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L-1.png","datePublished":"2024-03-01T10:08:22+00:00","dateModified":"2026-11-19T14:14:14+00:00","description":"Use Python to communicate remotely with the Longer BT100-1L pump via RS485. Learn how to write and send control command strings to the pump.","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L-1.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L-1.png","width":981,"height":938,"caption":"An image of a Longer BT100-1L peristaltic pump without background"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/how-to-control-the-longer-bt100-1l-pump-via-python\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"How to control the Longer BT100-1L pump via Python ?"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/eliamissi\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/BT-100L-1.png","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/18628","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=18628"}],"version-history":[{"count":84,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/18628\/revisions"}],"predecessor-version":[{"id":33700,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/18628\/revisions\/33700"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/18629"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=18628"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=18628"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=18628"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}