{"id":30492,"date":"2024-11-18T12:53:18","date_gmt":"2024-11-18T11:53:18","guid":{"rendered":"https:\/\/blog.darwin-microfluidics.com\/?p=30492"},"modified":"2026-11-19T15:33:44","modified_gmt":"2026-11-19T14:33:44","slug":"pps-polyphenylene-sulfide-chemical-compatibility-chart","status":"publish","type":"post","link":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/","title":{"rendered":"PPS (Polyphenylene Sulfide) \u2013 Chemical Compatibility Chart"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"30492\" class=\"elementor elementor-30492\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-19369fa elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"19369fa\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-cb0ecf5\" data-id=\"cb0ecf5\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-8b415cb elementor-widget elementor-widget-text-editor\" data-id=\"8b415cb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>When selecting materials for <strong>microfluidic applications<\/strong>, ensuring <strong>chemical compatibility<\/strong> is key to preserving system performance and integrity. <a href=\"https:\/\/darwin-microfluidics.com\/search-results-page?q=pps\"><strong>Polyphenylene Sulfide (PPS)<\/strong><\/a> is a popular choice due to its excellent mechanical properties, resistance to chemicals, and thermal stability. It is highly resistant to a wide range of acids, bases, salts, and organic solvents, making it ideal for demanding environments.<\/p><p>However, not all chemicals are compatible with PPS, so it&rsquo;s crucial to understand its chemical compatibility to prevent material degradation and ensure safety. This guide provides a detailed chemical compatibility table for <strong>PPS<\/strong>, based on data from <a href=\"https:\/\/www.idex-hs.com\/resources\/resources-detail\/chemical-compatibility\" target=\"_blank\" rel=\"noopener\">IDEX<\/a>,&nbsp;helping engineers and researchers assess its suitability for different applications.<\/p><p><span style=\"color: inherit; font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight ); font-size: 1rem; letter-spacing: -0.01rem;\">Refer to this table to make informed choices and maintain the efficiency and safety of your system.<\/span><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-6e0052e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"6e0052e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6d77aef\" data-id=\"6d77aef\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-898ccf1 elementor-widget elementor-widget-text-editor\" data-id=\"898ccf1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>&#128161; The chemical compatibility rating key is as follows:<\/p><ul><li>A = Little to No Effect<\/li><li>B = Slight Effect (Minor Discoloration or Corrosion)<\/li><li>C = Moderate to Severe Effect (Not Recommended)<\/li><\/ul><p>&#128680; <em>The compatibility ratings provided in these tables are for general guidance only and may not be complete or accurate. They do not address potential contamination or changes in fluid properties due to tubing interaction. We do not guarantee the suitability of any material for specific purposes or the impact of tubing on fluid quality. For critical applications, conduct specific tests or seek expert advice.<\/em><\/p>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-755bcd2 elementor-widget elementor-widget-text-editor\" data-id=\"755bcd2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 class=\"h3 text-heading-default font-weight-bold\" data-class=\"text-heading-default\">PPS: Chemical Compatibility Table<\/h2>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1b5139c elementor-widget elementor-widget-shortcode\" data-id=\"1b5139c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-96\" class=\"tablepress tablepress-id-96\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Chemical Substance<\/th><th class=\"column-2\">Compatibility<\/th><th class=\"column-3\">Notes<\/th>\n<\/tr>\n<\/thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">A<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Acetaldehyde<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Acetic acid, 10%<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Acetic acid, glacial<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Acetic anhydride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Acetone<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Acetonitrile<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Acetophenone<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Acetyl chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Acetylene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Acid mine water<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Acrylic acid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Aluminum chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Aluminum sulfate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Aminoethanol (2-)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Ammonia, anhydrous<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Ammonium chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Ammonium hydroxide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">Ammonium nitrate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">Ammonium sulfate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">Amyl acetate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">Amyl alcohol<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">Aniline<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance; prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">Antifreeze<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">Aqua regia<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">Asphalt emulsions<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-28\">\n\t<td class=\"column-1\">B<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-29\">\n\t<td class=\"column-1\">Barium chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-30\">\n\t<td class=\"column-1\">Barium hydroxide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-31\">\n\t<td class=\"column-1\">Barium sulfate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-32\">\n\t<td class=\"column-1\">Benzaldehyde<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance; prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-33\">\n\t<td class=\"column-1\">Benzene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-34\">\n\t<td class=\"column-1\">Benzene sulfonic acid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-35\">\n\t<td class=\"column-1\">Benzoic acid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-36\">\n\t<td class=\"column-1\">Benzonitrile<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance; prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-37\">\n\t<td class=\"column-1\">Benzyl chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-38\">\n\t<td class=\"column-1\">Borax<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-39\">\n\t<td class=\"column-1\">Brake fluid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-40\">\n\t<td class=\"column-1\">Bromine<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-41\">\n\t<td class=\"column-1\">Butadiene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-42\">\n\t<td class=\"column-1\">Butane<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-43\">\n\t<td class=\"column-1\">Butyl acetate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-44\">\n\t<td class=\"column-1\">Butyl alcohol (n-)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-45\">\n\t<td class=\"column-1\">Butyl ether<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-46\">\n\t<td class=\"column-1\">Butyl phthalate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-47\">\n\t<td class=\"column-1\">Butylamine<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance; prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-48\">\n\t<td class=\"column-1\">Butylene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-49\">\n\t<td class=\"column-1\">C<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-50\">\n\t<td class=\"column-1\">Calcium chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-51\">\n\t<td class=\"column-1\">Calcium nitrate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-52\">\n\t<td class=\"column-1\">Calcium sulfate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-53\">\n\t<td class=\"column-1\">Carbon dioxide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-54\">\n\t<td class=\"column-1\">Carbon disulfide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-55\">\n\t<td class=\"column-1\">Carbon tetrachloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance; prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-56\">\n\t<td class=\"column-1\">Carbonated water<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-57\">\n\t<td class=\"column-1\">Carbonic acid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-58\">\n\t<td class=\"column-1\">Cellosolve<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-59\">\n\t<td class=\"column-1\">Chlorine<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-60\">\n\t<td class=\"column-1\">Chlorobenzene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-61\">\n\t<td class=\"column-1\">Chloroethanol (2-)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-62\">\n\t<td class=\"column-1\">Chloroform<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance; prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-63\">\n\t<td class=\"column-1\">Chlorophenol, 5% aqueous<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-64\">\n\t<td class=\"column-1\">Chlorosulfonic acid<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-65\">\n\t<td class=\"column-1\">Chromic acid<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-66\">\n\t<td class=\"column-1\">Clorox (5.25% sodium hypochlorite)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-67\">\n\t<td class=\"column-1\">Clycolic acid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-68\">\n\t<td class=\"column-1\">Copper chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-69\">\n\t<td class=\"column-1\">Copper sulfate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-70\">\n\t<td class=\"column-1\">Cottonseed oil<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-71\">\n\t<td class=\"column-1\">Cresol (m-)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-72\">\n\t<td class=\"column-1\">Cresyl diphenyl phosphate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-73\">\n\t<td class=\"column-1\">Crude oil (aromatic)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-74\">\n\t<td class=\"column-1\">Cyclohexane<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-75\">\n\t<td class=\"column-1\">Cyclohexanol<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-76\">\n\t<td class=\"column-1\">Cyclohexanone<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-77\">\n\t<td class=\"column-1\">D<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-78\">\n\t<td class=\"column-1\">Detergents<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-79\">\n\t<td class=\"column-1\">Dichloroethane (1,2-)<\/td><td class=\"column-2\">B<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-80\">\n\t<td class=\"column-1\">Dichloromethane<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-81\">\n\t<td class=\"column-1\">Diesel fuel<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-82\">\n\t<td class=\"column-1\">Diethanolamine, 25%<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-83\">\n\t<td class=\"column-1\">Diethyl ether<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-84\">\n\t<td class=\"column-1\">Diisobutylene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-85\">\n\t<td class=\"column-1\">Dimethyl phthalate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-86\">\n\t<td class=\"column-1\">Dimethyl sulfoxide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-87\">\n\t<td class=\"column-1\">Dimethylaniline<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-88\">\n\t<td class=\"column-1\">Dimethylformamide (N,N-)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-89\">\n\t<td class=\"column-1\">Dioctyl phthalate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-90\">\n\t<td class=\"column-1\">Dioxane (p-)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-91\">\n\t<td class=\"column-1\">Diphyenyl ether<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-92\">\n\t<td class=\"column-1\">Dowtherm<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-93\">\n\t<td class=\"column-1\">E<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-94\">\n\t<td class=\"column-1\">Engine oil<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-95\">\n\t<td class=\"column-1\">Epichlorohydrin<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-96\">\n\t<td class=\"column-1\">Ethane<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-97\">\n\t<td class=\"column-1\">Ethanol<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-98\">\n\t<td class=\"column-1\">Ethanolamine<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-99\">\n\t<td class=\"column-1\">Ethoxyethanol (2-)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-100\">\n\t<td class=\"column-1\">Ethyl acetate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-101\">\n\t<td class=\"column-1\">Ethyl chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-102\">\n\t<td class=\"column-1\">Ethyl ether<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-103\">\n\t<td class=\"column-1\">Ethyl Mercaptan<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-104\">\n\t<td class=\"column-1\">Ethylene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-105\">\n\t<td class=\"column-1\">Ethylene chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-106\">\n\t<td class=\"column-1\">Ethylene chlorohydrin<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-107\">\n\t<td class=\"column-1\">Ethylene dichloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-108\">\n\t<td class=\"column-1\">Ethylene glycol<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-109\">\n\t<td class=\"column-1\">Ethylene glycol monoethylether<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-110\">\n\t<td class=\"column-1\">Ethylenediamine<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-111\">\n\t<td class=\"column-1\">F<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-112\">\n\t<td class=\"column-1\">Ferric chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-113\">\n\t<td class=\"column-1\">Ferrous chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-114\">\n\t<td class=\"column-1\">Fluorosilicic acid, 25%<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-115\">\n\t<td class=\"column-1\">Formaldehyde<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-116\">\n\t<td class=\"column-1\">Formic acid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-117\">\n\t<td class=\"column-1\">Freon<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-118\">\n\t<td class=\"column-1\">Fuel oil<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-119\">\n\t<td class=\"column-1\">Furan<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-120\">\n\t<td class=\"column-1\">Furfural<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-121\">\n\t<td class=\"column-1\">G<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-122\">\n\t<td class=\"column-1\">Gasohol<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-123\">\n\t<td class=\"column-1\">Gasoline<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-124\">\n\t<td class=\"column-1\">H<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-125\">\n\t<td class=\"column-1\">Heptane<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-126\">\n\t<td class=\"column-1\">Hexane<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-127\">\n\t<td class=\"column-1\">Hexene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-128\">\n\t<td class=\"column-1\">HFC-134a<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-129\">\n\t<td class=\"column-1\">Hydraulic fluid, aircraft<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-130\">\n\t<td class=\"column-1\">Hydrazine<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-131\">\n\t<td class=\"column-1\">Hydrobromic acid<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-132\">\n\t<td class=\"column-1\">Hydrochloric acid<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-133\">\n\t<td class=\"column-1\">Hydrofluoric acid<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-134\">\n\t<td class=\"column-1\">Hydrogen gas<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-135\">\n\t<td class=\"column-1\">Hydrogen peroxide<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-136\">\n\t<td class=\"column-1\">Hydrogen sulfide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-137\">\n\t<td class=\"column-1\">I<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-138\">\n\t<td class=\"column-1\">Iodine<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-139\">\n\t<td class=\"column-1\">Isopropyl alcohol<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-140\">\n\t<td class=\"column-1\">Isopropyl mercaptan<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-141\">\n\t<td class=\"column-1\">J<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-142\">\n\t<td class=\"column-1\">Jet fuel<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-143\">\n\t<td class=\"column-1\">K<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-144\">\n\t<td class=\"column-1\">Kerosene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-145\">\n\t<td class=\"column-1\">L<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-146\">\n\t<td class=\"column-1\">Lactic acid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-147\">\n\t<td class=\"column-1\">Liquefied petroleum gas (LPG)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-148\">\n\t<td class=\"column-1\">Lithium bromide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-149\">\n\t<td class=\"column-1\">Lubricating oil<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-150\">\n\t<td class=\"column-1\">M<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-151\">\n\t<td class=\"column-1\">Magnesium chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-152\">\n\t<td class=\"column-1\">Magnesium hydroxide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-153\">\n\t<td class=\"column-1\">MEK<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-154\">\n\t<td class=\"column-1\">Methane<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-155\">\n\t<td class=\"column-1\">Methanol<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-156\">\n\t<td class=\"column-1\">Methoxy Propanol<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-157\">\n\t<td class=\"column-1\">Methyl acrylate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-158\">\n\t<td class=\"column-1\">Methyl isobutyl ketone<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-159\">\n\t<td class=\"column-1\">Methyl mercaptan<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-160\">\n\t<td class=\"column-1\">Methyl methacrylate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-161\">\n\t<td class=\"column-1\">Methyl tert-butyl ether<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-162\">\n\t<td class=\"column-1\">Methyl-pyrrolidinone (N-)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance; prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-163\">\n\t<td class=\"column-1\">Methylene chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-164\">\n\t<td class=\"column-1\">Mineral oil<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-165\">\n\t<td class=\"column-1\">Morpholine<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-166\">\n\t<td class=\"column-1\">Motor oil<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-167\">\n\t<td class=\"column-1\">N<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-168\">\n\t<td class=\"column-1\">Naphtha<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-169\">\n\t<td class=\"column-1\">Naphthalene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-170\">\n\t<td class=\"column-1\">Nitric acid<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-171\">\n\t<td class=\"column-1\">Nitrobenzene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance; prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-172\">\n\t<td class=\"column-1\">Nitrogen<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-173\">\n\t<td class=\"column-1\">Nitrogen tetroxide<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-174\">\n\t<td class=\"column-1\">Nitromethane<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-175\">\n\t<td class=\"column-1\">O<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-176\">\n\t<td class=\"column-1\">Ozone<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-177\">\n\t<td class=\"column-1\">P<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-178\">\n\t<td class=\"column-1\">Perchloroethylene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-179\">\n\t<td class=\"column-1\">Peroxyacetic acid<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-180\">\n\t<td class=\"column-1\">Peroxybenzoic acid<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-181\">\n\t<td class=\"column-1\">Phenol<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance; prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-182\">\n\t<td class=\"column-1\">Phosphoric acid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-183\">\n\t<td class=\"column-1\">Phosphorus trichloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-184\">\n\t<td class=\"column-1\">Potassium chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-185\">\n\t<td class=\"column-1\">Potassium dichromate<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-186\">\n\t<td class=\"column-1\">Potassium hydroxide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-187\">\n\t<td class=\"column-1\">Potassium permanganate<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-188\">\n\t<td class=\"column-1\">Propane<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-189\">\n\t<td class=\"column-1\">Propyl mercaptan<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-190\">\n\t<td class=\"column-1\">Propylene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-191\">\n\t<td class=\"column-1\">Propylene chlorohydrin<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-192\">\n\t<td class=\"column-1\">Propylene glycol monomethylether<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-193\">\n\t<td class=\"column-1\">Pyridine<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-194\">\n\t<td class=\"column-1\">R<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-195\">\n\t<td class=\"column-1\">Refrigerant R-22<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-196\">\n\t<td class=\"column-1\">S<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-197\">\n\t<td class=\"column-1\">Salt Water<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-198\">\n\t<td class=\"column-1\">Sea water<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-199\">\n\t<td class=\"column-1\">Sodium acetate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-200\">\n\t<td class=\"column-1\">Sodium bicarbonate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-201\">\n\t<td class=\"column-1\">Sodium bisulfate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-202\">\n\t<td class=\"column-1\">Sodium carbonate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-203\">\n\t<td class=\"column-1\">Sodium chloride<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-204\">\n\t<td class=\"column-1\">Sodium cyanide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-205\">\n\t<td class=\"column-1\">Sodium dichromate<\/td><td class=\"column-2\">C<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-206\">\n\t<td class=\"column-1\">Sodium hydrosulfite<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-207\">\n\t<td class=\"column-1\">Sodium hydroxide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-208\">\n\t<td class=\"column-1\">Sodium hypochlorite, 5%<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-209\">\n\t<td class=\"column-1\">Sodium nitrate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-210\">\n\t<td class=\"column-1\">Sodium sulfate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-211\">\n\t<td class=\"column-1\">Sodium sulfide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-212\">\n\t<td class=\"column-1\">Sodium thiosulfate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-213\">\n\t<td class=\"column-1\">Steam<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-214\">\n\t<td class=\"column-1\">Stoddard solvent<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-215\">\n\t<td class=\"column-1\">Sulfolane<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-216\">\n\t<td class=\"column-1\">Sulfur dioxide<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-217\">\n\t<td class=\"column-1\">Sulfuric acid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-218\">\n\t<td class=\"column-1\">T<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-219\">\n\t<td class=\"column-1\">Tap water<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-220\">\n\t<td class=\"column-1\">Tetrahydrofuran<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-221\">\n\t<td class=\"column-1\">Thiophenol<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-222\">\n\t<td class=\"column-1\">Toluene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance; prolonged exposure may weaken material.<\/td>\n<\/tr>\n<tr class=\"row-223\">\n\t<td class=\"column-1\">Tomato juice<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-224\">\n\t<td class=\"column-1\">Transmission fluid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-225\">\n\t<td class=\"column-1\">Trichloroacetic acid<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-226\">\n\t<td class=\"column-1\">Trichloroethane (1,1,1-)<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-227\">\n\t<td class=\"column-1\">Trichloroethylene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-228\">\n\t<td class=\"column-1\">Trichlorotrifluoroethane<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-229\">\n\t<td class=\"column-1\">Triethyl phosphate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-230\">\n\t<td class=\"column-1\">Triethylamine<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-231\">\n\t<td class=\"column-1\">Triphenyl phosphite<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-232\">\n\t<td class=\"column-1\">Trisodium phosphate<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-233\">\n\t<td class=\"column-1\">Turpentine<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-234\">\n\t<td class=\"column-1\">V<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-235\">\n\t<td class=\"column-1\">Vegetable oil<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-236\">\n\t<td class=\"column-1\">Vinegar<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-237\">\n\t<td class=\"column-1\">W<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-238\">\n\t<td class=\"column-1\">Water<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-239\">\n\t<td class=\"column-1\">X<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-240\">\n\t<td class=\"column-1\">Xylene<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\">Elevated temperatures may reduce resistance.<\/td>\n<\/tr>\n<tr class=\"row-241\">\n\t<td class=\"column-1\">Z<\/td><td class=\"column-2\"><\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<tr class=\"row-242\">\n\t<td class=\"column-1\">Zinc chloride, 50%<\/td><td class=\"column-2\">A<\/td><td class=\"column-3\"><\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<!-- #tablepress-96 from cache --><\/div>\n\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d99a29d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d99a29d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2b1dcde\" data-id=\"2b1dcde\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-98a7932 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"98a7932\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Need some help with your microfluidic project?\"\/><a href=\"https:\/\/darwin-microfluidics.com\/contact-us\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Contact our experts!<\/span><\/span><\/span><\/div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Need some help with your microfluidic project?<\/h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>We can make microfluidics easy for you!<\/span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"><\/i><\/span><\/div><\/a><\/div>\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t<\/section>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>When selecting materials for microfluidic applications, ensuring chemical compatibility is key to preserving system performance and integrity. Polyphenylene Sulfide (PPS) is a popular choice due to its excellent mechanical properties, resistance to chemicals, and thermal stability. It is highly resistant&hellip;<\/p>\n","protected":false},"author":4,"featured_media":30497,"comment_status":"closed","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_jetpack_newsletter_access":"","_jetpack_dont_email_post_to_subs":false,"_jetpack_newsletter_tier_id":0,"_jetpack_memberships_contains_paywalled_content":false,"_kc_parent_guide":"","_kc_products":"","_kc_type":"","_jetpack_hide_featured_image":false,"_jetpack_featured_image_duplicate_dismissed":0,"_jetpack_feature_clip_id":0,"_jetpack_memberships_contains_paid_content":false,"footnotes":"","jetpack_post_was_ever_published":false},"categories":[66,28,70],"tags":[],"class_list":["post-30492","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-chemical-compatibility","category-connectors-tubing","category-materials"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.7 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>PPS (Polyphenylene Sulfide) \u2013 Chemical Compatibility Chart<\/title>\n<meta name=\"description\" content=\"Explore the PPS Chemical Compatibility Chart to find out how this material interacts with various chemicals and environments.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"PPS (Polyphenylene Sulfide) \u2013 Chemical Compatibility Chart\" \/>\n<meta property=\"og:description\" content=\"Explore the PPS Chemical Compatibility Chart to find out how this material interacts with various chemicals and environments.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/\" \/>\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\" \/>\n<meta property=\"article:published_time\" content=\"2024-11-18T11:53:18+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:33:44+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/11\/Flangeless-Nut.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"640\" \/>\n\t<meta property=\"og:image:height\" content=\"640\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Elia Missi\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"PPS (Polyphenylene Sulfide) \u2013 Chemical Compatibility Chart\",\"datePublished\":\"2024-11-18T11:53:18+00:00\",\"dateModified\":\"2026-11-19T14:33:44+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/\"},\"wordCount\":243,\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/Flangeless-Nut.jpg\",\"articleSection\":[\"Chemical compatibility charts\",\"Connectors &amp; tubing\",\"Materials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/\",\"name\":\"PPS (Polyphenylene Sulfide) \u2013 Chemical Compatibility Chart\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/Flangeless-Nut.jpg\",\"datePublished\":\"2024-11-18T11:53:18+00:00\",\"dateModified\":\"2026-11-19T14:33:44+00:00\",\"description\":\"Explore the PPS Chemical Compatibility Chart to find out how this material interacts with various chemicals and environments.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/#primaryimage\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/Flangeless-Nut.jpg\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/11\\\/Flangeless-Nut.jpg\",\"width\":640,\"height\":640,\"caption\":\"Flangeless Nut in PPS\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/pps-polyphenylene-sulfide-chemical-compatibility-chart\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"PPS (Polyphenylene Sulfide) \u2013 Chemical Compatibility Chart\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#website\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"name\":\"Blog\",\"description\":\"Our Blog\",\"publisher\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/wp-content\\\/uploads\\\/2024\\\/02\\\/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"},\"sameAs\":[\"https:\\\/\\\/www.linkedin.com\\\/company\\\/darwin-microfluidics\\\/\",\"https:\\\/\\\/darwin-microfluidics.com\"]},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/#\\\/schema\\\/person\\\/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https:\\\/\\\/blog.darwin-microfluidics.com\\\/author\\\/eliamissi\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"PPS (Polyphenylene Sulfide) \u2013 Chemical Compatibility Chart","description":"Explore the PPS Chemical Compatibility Chart to find out how this material interacts with various chemicals and environments.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/","og_locale":"en_US","og_type":"article","og_title":"PPS (Polyphenylene Sulfide) \u2013 Chemical Compatibility Chart","og_description":"Explore the PPS Chemical Compatibility Chart to find out how this material interacts with various chemicals and environments.","og_url":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-11-18T11:53:18+00:00","article_modified_time":"2026-11-19T14:33:44+00:00","og_image":[{"width":640,"height":640,"url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/11\/Flangeless-Nut.jpg","type":"image\/jpeg"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/#article","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/"},"author":{"name":"Elia Missi","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/c80a1276036340d7e994346f251af8f5"},"headline":"PPS (Polyphenylene Sulfide) \u2013 Chemical Compatibility Chart","datePublished":"2024-11-18T11:53:18+00:00","dateModified":"2026-11-19T14:33:44+00:00","mainEntityOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/"},"wordCount":243,"publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/11\/Flangeless-Nut.jpg","articleSection":["Chemical compatibility charts","Connectors &amp; tubing","Materials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/","url":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/","name":"PPS (Polyphenylene Sulfide) \u2013 Chemical Compatibility Chart","isPartOf":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/#primaryimage"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/#primaryimage"},"thumbnailUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/11\/Flangeless-Nut.jpg","datePublished":"2024-11-18T11:53:18+00:00","dateModified":"2026-11-19T14:33:44+00:00","description":"Explore the PPS Chemical Compatibility Chart to find out how this material interacts with various chemicals and environments.","breadcrumb":{"@id":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/#primaryimage","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/11\/Flangeless-Nut.jpg","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/11\/Flangeless-Nut.jpg","width":640,"height":640,"caption":"Flangeless Nut in PPS"},{"@type":"BreadcrumbList","@id":"https:\/\/blog.darwin-microfluidics.com\/pps-polyphenylene-sulfide-chemical-compatibility-chart\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/blog.darwin-microfluidics.com\/"},{"@type":"ListItem","position":2,"name":"PPS (Polyphenylene Sulfide) \u2013 Chemical Compatibility Chart"}]},{"@type":"WebSite","@id":"https:\/\/blog.darwin-microfluidics.com\/#website","url":"https:\/\/blog.darwin-microfluidics.com\/","name":"Blog","description":"Our Blog","publisher":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/blog.darwin-microfluidics.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/blog.darwin-microfluidics.com\/#organization","name":"Darwin Microfluidics","url":"https:\/\/blog.darwin-microfluidics.com\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/","url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","contentUrl":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/02\/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.linkedin.com\/company\/darwin-microfluidics\/","https:\/\/darwin-microfluidics.com"]},{"@type":"Person","@id":"https:\/\/blog.darwin-microfluidics.com\/#\/schema\/person\/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https:\/\/blog.darwin-microfluidics.com\/author\/eliamissi\/"}]}},"jetpack_sharing_enabled":true,"jetpack_featured_media_url":"https:\/\/blog.darwin-microfluidics.com\/wp-content\/uploads\/2024\/11\/Flangeless-Nut.jpg","_links":{"self":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/30492","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/users\/4"}],"replies":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/comments?post=30492"}],"version-history":[{"count":16,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/30492\/revisions"}],"predecessor-version":[{"id":30509,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/posts\/30492\/revisions\/30509"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media\/30497"}],"wp:attachment":[{"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/media?parent=30492"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/categories?post=30492"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/blog.darwin-microfluidics.com\/wp-json\/wp\/v2\/tags?post=30492"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}