{"id":14296,"date":"2023-02-22T11:23:19","date_gmt":"2023-02-22T10:23:19","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14296"},"modified":"2024-02-27T12:12:58","modified_gmt":"2024-02-27T11:12:58","slug":"step-emulsification-for-high-throughput-droplet-generation-a-review","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/","title":{"rendered":"Step emulsification for high-throughput droplet generation: a review"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14296\" class=\"elementor elementor-14296\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-5195888 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"5195888\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6ac86e1\" data-id=\"6ac86e1\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0f534f3 elementor-widget elementor-widget-text-editor\" data-id=\"0f534f3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De stapsgewijze emulsificatie is een variant van de druppelgeneratietechniek genaamd co-flow. Deze nieuwe techniek is gebaseerd op de instabiliteit van een tweefasige vloeistofdraad die wordt getriggerd door een abrupte verandering in de stromingsopsluiting (Figuur 1). Het is meer direct geïnspireerd op <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microkanaal</a>-emulsificatie omdat het gebruikmaakt van microgefabriceerde kanaalnetwerken die een opmerkelijk strakke geometrische controle van de druppelgrootte mogelijk maken.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a511b2 elementor-widget elementor-widget-image\" data-id=\"5a511b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"300\" height=\"160\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1-300x160.webp\" class=\"attachment-medium size-medium wp-image-14298\" alt=\"Schematische illustratie van een stapsgewijs emulsificatiekanaal\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1-300x160.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp 660w\" sizes=\"(max-width: 300px) 100vw, 300px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figuur 1: Schematische illustratie van een stapsgewijs emulsificatiekanaal. De druppelbreuk vindt plaats bij de stap tussen het mondstuk en het kanaal voor de continue fase. Ofner et al. 2016 Macromol. Chem. Phys.</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8294f01 elementor-widget elementor-widget-text-editor\" data-id=\"8294f01\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Mechanisme van stapsgewijze emulsificatie</h2><p>De techniek van stapsgewijze emulsificatie wordt gebruikt om druppels te genereren met diameters variërend van nanometer tot honderden micrometers. Om dit proces uit te voeren, bestaat de benodigde apparatuur uit een kanaal voor de gedispergeerde fase, een reservoir voor de continue fase en een mondstuk, met een hoogte die aanzienlijk verschilt van het reservoir.</p><p>Om deze techniek te karakteriseren zijn verschillende geometrische modellen opgesteld. Van deze modellen is het quasi-statische mechanisme door de meeste onderzoekers behouden om te begrijpen hoe de druppels worden gegenereerd. Volgens Dangla et al. 2013 J Phys D Appl Phys wordt dit model bepaald door drie hypothesen:</p><ol><li>de gedispergeerde fase kan de kanaalwanden niet bevochtigen voor druppelvorming,</li><li>het gravitationele effect is verwaarloosbaar,</li><li>het systeem evolueert op een quasi-statische manier.</li></ol><p>Om succesvol druppels te genereren via stapsgewijze emulsificatie, moet eerst de continue fase met de surfactant worden geïnjecteerd om het reservoir te vullen. Vervolgens wordt de gedispergeerde niet-mengbare fase in het kanaal geïnjecteerd. Terwijl de draad van de gedispergeerde fase door de stap gaat, ontstaat er stroomafwaarts van de stap een bolvormige uitstulping. Naarmate de gedispergeerde fase continu wordt geïnjecteerd, neemt de gemiddelde kromming van de uitstulping af, terwijl de grootte ervan toenemend groeit (Figuur 2).</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-03cc5a1 elementor-widget elementor-widget-image\" data-id=\"03cc5a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"260\" height=\"221\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-section_views_of_the_nozzle_in_two_lateral_direction-1.webp\" class=\"attachment-medium size-medium wp-image-14302\" alt=\"\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figuur 2: Doorsnedeaanzichten van het mondstuk in twee laterale richtingen. I. De gedispergeerde fase wordt in het mondstuk geïnjecteerd. II. De straal van de uitstulping bereikt de kritische waarde en begint de insnoeringszone te vormen. III. De diameter van het mondstuk neemt na insnoering af tot de hoogte van het mondstuk. IV. De druppel scheidt zich af van de gedispergeerde fase in de continue fase. Shi et al. 2020. R. Soc. Chem.</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-348c523 elementor-widget elementor-widget-global elementor-global-18298 elementor-widget-pix-promo-box\" data-id=\"348c523\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Droplet-generators_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"WIL JE MICROFLUÏDISCHE druppelvorming VEREENVOUDIGEN?\"><a href=\"https://darwin-microfluidics.com/nl/collections/drukregelaar/producten/ob1-microfluidic-droplet-pack\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Ontdek onze selectie!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">WIL JE MICROFLUÏDISCHE druppelvorming VEREENVOUDIGEN?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Ontsluit het potentieel van onze gebruiksvriendelijke systemen voor moeiteloze druppelgeneratie</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-08c8378 elementor-widget elementor-widget-text-editor\" data-id=\"08c8378\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2>Typen ontwerpen voor stapsgewijze emulsificatie</h2><p>De gegroEFDe <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microchannel</a> emulsificatiestap wordt gestuurd door interfaciale spanning voor druppelvorming bij gebruik van druk of debiet. Klassiek omvat het gegroefde <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microchannel</a> een kanaal voor de gedispergeerde fase, een mondstuk, een terras en een reservoir voor de continue fase (Figuur 3a). Dit type apparaat kan op een siliciumwafel worden vervaardigd door middel van <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/photolithography-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">fotolithografie</a> en oriëntatie-afhankelijke etsing.</p><p>Een tweede voorbeeld is het gebruik van een recht <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microchannel</a> voor stapsgewijze emulsificatie, waarvan de structuur langwerpige rechte openingen omvat voor de vorming van druppels (Figuur 3b). De druppeldiameter is lineair gerelateerd aan de diepte van de rechte opening, wat grofweg een veelvoud van 4 is. Voor de vervaardiging van dit apparaat kan diepe reactieve ionenetsing (DRIE) op een siliciumwafel worden gebruikt.</p><p>Een andere stapsgewijze emulsificatiestructuur die de generatie van druppels bij hoge debieten mogelijk maakt, is de Edge Droplet Generation Device (EDGE). Dit keer is het geen rechte opening meer, maar een breed, ondiep plateau als mondstuk, waarin parallelle druppels gelijktijdig worden gegenereerd vanuit een enkel mondstuk (Figuur 3c). Om dit apparaat te maken, wordt een siliciumwafel geëtst met behulp van de diepe reactieve ionenetsingstechniek (DRIE) en vervolgens verbonden met een glazen plaat.</p><p>Tot nu toe zijn in de bovengenoemde apparaten alleen rechthoekige mondstukken gebruikt. Driehoekige mondstukken hebben echter betere prestaties aangetoond. Het driehoekige mondstuk fungeert vervolgens als een terras voor de terugstroom van de continue fase met de uitgerekte dwarsdoorsnede (Figuur 3d). Op deze manier biedt het driehoekige mondstuk een onafhankelijk lokaal gebied voor de vorming van druppels om ongewenste interferentie van de gedispergeerde en continue fasen te voorkomen.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b7a3925 elementor-widget elementor-widget-image\" data-id=\"b7a3925\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"148\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_of_microfluidic_step_emulsification_devices-1.webp\" class=\"attachment-medium_large size-medium_large wp-image-14303\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_of_microfluidic_step_emulsification_devices-1.webp 704w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_of_microfluidic_step_emulsification_devices-1-300x69.webp 300w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-63c206b elementor-widget elementor-widget-text-editor\" data-id=\"63c206b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bij stapsgewijze emulsificatie is het belangrijk op te merken dat de grootte van de monodisperse druppels gerelateerd is aan de geometrische kenmerken van het <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microchannel</a>, wat betekent dat de druppeldiameter moeilijk te aan te passen is zodra het <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microchannel</a> is ontworpen.</p><p>Hoewel beperkt in druppelgrootte door geometrie, is stapsgewijze emulsificatie een robuust hulpmiddel, met name in combinatie met detectie-, identificatie- en informatietechnologieën, wat de meting van bio-informatie zal verbeteren.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b68076 elementor-widget elementor-widget-global elementor-global-18301 elementor-widget-pix-promo-box\" data-id=\"5b68076\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Droplet-generators_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"UW DRUPPELPRODUCTIE OPSCHALEN?\"><div class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Ontdek onze selectie!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">UW DRUPPELPRODUCTIE OPSCHALEN?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Ontdek onze schaalbare oplossingen die ontworpen zijn om gemakkelijk te voldoen aan de eisen van high-throughput druppelgeneratie</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></div></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>The step emulsification is a variant of the droplet generation technique called co-flow. This new technique is based on the instability of a two-phase liquid wire triggered by an abrupt change in the flow confinement (Figure 1). It is more…</p>\n","protected":false},"author":3,"featured_media":14298,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[23,21],"tags":[],"class_list":["post-14296","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-droplet-generation","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Stapsgewijze emulgering voor high-throughput- druppelvorming: een overzicht</title>\n<meta name=\"description\" content=\"Stapsgewijze emulsificatie is een variant van druppelgeneratie. Deze techniek maakt een hoge doorvoer van kleine druppels mogelijk. Ontdek hoe!\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Stapsgewijze emulgering voor high-throughput- druppelvorming: een overzicht\">\n<meta property=\"og:description\" content=\"Stapsgewijze emulsificatie is een variant van druppelgeneratie. Deze techniek maakt een hoge doorvoer van kleine druppels mogelijk. Ontdek hoe!\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-22T10:23:19+00:00\">\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:12:58+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp\">\n\t<meta property=\"og:image:width\" content=\"660\">\n\t<meta property=\"og:image:height\" content=\"351\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"4 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Step emulsification for high-throughput droplet generation: a review\",\"datePublished\":\"2023-02-22T10:23:19+00:00\",\"dateModified\":\"2024-02-27T11:12:58+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\"},\"wordCount\":745,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"articleSection\":[\"Droplet generation\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\",\"url\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\",\"name\":\"Step emulsification for high-throughput droplet generation: a review\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"datePublished\":\"2023-02-22T10:23:19+00:00\",\"dateModified\":\"2024-02-27T11:12:58+00:00\",\"description\":\"Stapsgewijze emulsificatie is een variant van druppelgeneratie. Deze techniek maakt een hoge doorvoer van kleine druppels mogelijk. Ontdek hoe!\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp\",\"width\":660,\"height\":351,\"caption\":\"Schematic illustration of a step emulsification channel\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Step emulsification for high-throughput droplet generation: a review\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Onze blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/nl\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Step emulsification for high-throughput droplet generation: a review","description":"Stapsgewijze emulsificatie is een variant van druppelgeneratie. Deze techniek maakt een hoge doorvoer van kleine druppels mogelijk. Ontdek hoe!","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/","og_locale":"en_US","og_type":"article","og_title":"Step emulsification for high-throughput droplet generation: a review","og_description":"Step emulsification is a variant of droplet generation. This technique allows a high throughput of small droplets. Find out how!","og_url":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T10:23:19+00:00","article_modified_time":"2024-02-27T11:12:58+00:00","og_image":[{"width":660,"height":351,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"4 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Step emulsification for high-throughput droplet generation: a review","datePublished":"2023-02-22T10:23:19+00:00","dateModified":"2024-02-27T11:12:58+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/"},"wordCount":745,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","articleSection":["Droplet generation","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/","url":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/","name":"Step emulsification for high-throughput droplet generation: a review","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","datePublished":"2023-02-22T10:23:19+00:00","dateModified":"2024-02-27T11:12:58+00:00","description":"Stapsgewijze emulsificatie is een variant van druppelgeneratie. Deze techniek maakt een hoge doorvoer van kleine druppels mogelijk. Ontdek hoe!","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","width":660,"height":351,"caption":"Schematic illustration of a step emulsification channel"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/step-emulsification-for-high-throughput-droplet-generation-a-review/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Step emulsification for high-throughput droplet generation: a review"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Onze blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Schematic_illustration_of_a_step_emulsification_channel-1.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14296","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14296"}],"version-history":[{"count":11,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14296/revisions"}],"predecessor-version":[{"id":18460,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14296/revisions/18460"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14298"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14296"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14296"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14296"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}