{"id":14324,"date":"2023-02-22T12:07:49","date_gmt":"2023-02-22T11:07:49","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=14324"},"modified":"2024-02-27T12:11:34","modified_gmt":"2024-02-27T11:11:34","slug":"droplet-generation-in-microfluidics-the-most-used-designs","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/","title":{"rendered":"droplet generation in microfluidics: The most used designs"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"14324\" class=\"elementor elementor-14324\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-dee3d57 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"dee3d57\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-7f7271c\" data-id=\"7f7271c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-060f89b elementor-widget elementor-widget-text-editor\" data-id=\"060f89b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Platforms op basis van microfabricage en microfluïdica zijn met succes gebruikt in uiteenlopende toepassingen zoals drug discovery, polymerasekettingreactie (PCR), single-cell analyse of proteïnekristallisatie, om er maar enkele te noemen. Voor al deze toepassingen zijn het produceren van druppels in gecontroleerde groottes en gecontroleerde generatiesnelheden sleutelfactoren om interpreteerbare, betrouwbare en robuuste resultaten te verkrijgen. Druppelgrootte kan immers worden beïnvloed door vele factoren, zoals interfaciale spanning of kanaalgrootte.</p><p>Vandaag de dag is er een breed scala aan geometrieën ontwikkeld, waarmee druppels in passieve of actieve modus kunnen worden gegenereerd. In dit overzicht richten we ons op de meest gebruikte ontwerpen voor druppelgeneratie.</p><h2>Passieve en actieve modus</h2><h3>Passieve modus</h3><p>Microfluïdische methoden voor het vormen van druppels kunnen passief of actief zijn. Bij passieve methoden wordt de microfluïdische tweefasestroming geregeld door spuitpompen (die constante debieten leveren) of drukregelaars zonder extra energietoevoer. Tijdens de druppelvorming wordt een deel van de energie afkomstig van de spuitpompen of drukregelaars omgezet in interfaciale energie en vergemakkelijkt zo de destabilisatie van het vloeistof-vloeistofgrensvlak, waardoor discrete druppelafscheiding uit de gedispergeerde fase optreedt [Seemann R. et al. 2012 Rep Prog Phys.]. Praktisch gezien wordt de te dispergeren vloeistoffase in een <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microkanaal</a> gedreven door een pressure-driven flow waarin het volumedebiet of de toegepaste druk noodzakelijk wordt geregeld. Een tweede niet-mengbare vloeistof wordt in een apart <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/microchannel-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">microkanaal</a> geleid via een onafhankelijk geregelde stroom. De twee stromen ontmoeten elkaar bij de junctie. De geometrie van de junctie en de volumetrische debieten van de twee vloeistoffen bepalen het stromingsveld, dat het grensvlak vervormt <strong>[Christopher GF and Anna SL. 2007 J Phys Appl Phys]</strong>.</p><h3>Actieve modus</h3><p>In actieve modus is het mogelijk om de druppelgeneratie te moduleren met een extra energietoevoer door actieve regelingen, waaronder externe krachten zoals elektrische, magnetische of centrifugale velden en interne krachten zoals viskeuze en capillaire krachten. Om precies te zijn: de energie-onbalans moduleert de aard van de krachtbalans op het grensvlak voor druppelgeneratie.</p><p>De actieve druppelgeneratie kan worden geïnduceerd door twee soorten krachten: de modificatie van intrinsieke krachten of de introductie van extra krachten. Extra krachten worden benut door het toepassen van externe elektrische, magnetische en centrifugale velden, terwijl het modificeren van de intrinsieke traagheids-, viskeuze en capillaire krachten kan worden uitgevoerd door het manipuleren van de dynamische snelheid en materiaaleigenschappen, waaronder viscositeit, interfaciale spanning, kanaalbevochtiging en vloeistofdichtheid <strong>[Chong ZZ et al. 2016 Lab Chip.]</strong>.</p><h2>Ontwerpen van druppelgeneratiechips</h2><h3>Cross-flow met T-junction</h3><p>We spreken van cross-flow wanneer vloeistoffen van de gedispergeerde en continue fase elkaar ontmoeten onder een hoek θ tussen 0 en 180° (zie Fig. 1). Over het algemeen is de cross-flow-structuur gekoppeld aan een <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-junction</a>. De gedispergeerde en continue vloeistoffen worden dus orthogonaal toegevoerd.</p><p>Er zijn drie regimes voor microfluïdische druppelgeneratie met een <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/t-junction-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">T-junction</a>: het dripping-regime, het squeezing-regime en het jetting-regime (zie fig. 2). In principe zijn druppels die met de dripping-modus worden gegenereerd kleiner dan de kanaalafmeting en sterk monodispers. Bij het squeezing-regime zijn de druppels groter dan het kanaal en monodispers. Tot slot is de druppelgeneratie bij de jetting-modus polydispers.</p><p>Het eerste voordeel van de cross-flow is het gemak waarmee druppels kunnen worden gevormd en de uniformiteit van de resulterende druppels. Binnen een groot bereik van debieten is het inderdaad mogelijk om een reguliere en periodieke druppelvorming te verkrijgen wanneer een enkel T-vormig kanaal wordt gebruikt. Uit sommige studies <strong>[Garstecki P et al. 2005 Nature Phys ; Barbier et al. 2006 Phys Rev.]</strong> blijkt echter dat druppels niet noodzakelijkerwijs regelmatig zijn wanneer meerdere druppelgeneratoren worden gekoppeld aan een enkele set spuitpompen; dit kan een kritiek probleem vormen in het geval van een studie waarbij het noodzakelijk is om de druppelgrootte nauwkeurig te controleren.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a576702 elementor-widget elementor-widget-image\" data-id=\"a576702\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"107\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-flow-chip-designs-1-1024x171.webp\" class=\"attachment-large size-large wp-image-14326\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-flow-chip-designs-1-1024x171.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-flow-chip-designs-1-300x50.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-flow-chip-designs-1-768x128.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Cross-flow-chip-designs-1.webp 1481w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figure 1 : Schematic of various microfluidic device geometries (not to scale). (a) Cross-flow. (i) &ldquo;T-junction&rdquo; where the continuous and dispersed phase fluids meet perpendicularly (&theta; = 90&deg;). (ii) &ldquo;T-junction&rdquo; in which the two fluids intersect at an angle &theta; (0&deg; &lt; &theta; &lt; 90&deg;). (iii) &ldquo;Head-on&rdquo; geometry (&theta; = 180&deg;). (iv) Y-shaped junction with intersection angle of &theta; (0&deg; &lt; &theta; &lt; 180&deg;). [Zhu et Wang, Lab on Chip, 2017]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-50510a1 elementor-widget elementor-widget-image\" data-id=\"50510a1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"106\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-modes-cross-flow-1-1024x169.webp\" class=\"attachment-large size-large wp-image-14330\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-modes-cross-flow-1-1024x169.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-modes-cross-flow-1-300x50.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-modes-cross-flow-1-768x127.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-modes-cross-flow-1.webp 1070w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figuur 2 : Afbeeldingen van druppelgeneratie met verschillende modi in cross-flow. (a) Squeezing-modus. (b) Dripping-modus. (c) Jetting-modus. [Zhu et Wang, Lab on Chip, 2017]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a4b9153 elementor-widget elementor-widget-global elementor-global-18298 elementor-widget-pix-promo-box\" data-id=\"a4b9153\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Droplet-generators_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"WIL JE MICROFLUÏDISCHE druppelvorming VEREENVOUDIGEN?\"><a href=\"https://darwin-microfluidics.com/nl/collections/drukregelaar/producten/ob1-microfluidic-droplet-pack\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Ontdek onze selectie!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">WIL JE MICROFLUÏDISCHE druppelvorming VEREENVOUDIGEN?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Ontsluit het potentieel van onze gebruiksvriendelijke systemen voor moeiteloze druppelgeneratie</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6ec2db6 elementor-widget elementor-widget-text-editor\" data-id=\"6ec2db6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Stroomconcentratie</h3><p>Flow focusing komt overeen met de vorming van gedispergeerde druppels van een vloeistof in een continue stroom van een andere vloeistof. Er bestaan twee varianten van geometrische microfluïdische flow-focusing-systemen: de eenvoudige kruisverbinding en de kruisverbinding gevolgd door een constrictie (ook wel nozzle genoemd). Daarnaast kan er onderscheid worden gemaakt tussen een quasi-2D planetaire configuratie (zie fig. 3 (i) (ii)) en een axisymmetrische 3D-configuratie (zie fig. 3 (iii) (iv)).</p><p>Vergeleken met planetaire flow-focusing-apparaten vermijden 3D-axisymmetrische flow-focusing-apparaten problemen zoals het bevochtigen van kanaalwanden door de gedispergeerde fase, waardoor ze monodisperse druppels produceren bij hogere doorvoersnelheden.</p><p>Net als bij de cross-flow-geometrie is het vervolgens mogelijk om drie verschillende modi te onderscheiden: de squeezing-, dripping- en jetting-modus (zie fig. 4). Het voordeel van het gebruik van flow focusing ligt in de eenvoud wat betreft geometrie, en dus de vele ontwerpvariaties. Er is echter geen eenvoudig mechanistisch model beschikbaar dat de druppelgrootte over een breed scala aan stromingsomstandigheden kan voorspellen. Een ander bekend probleem is het ongewenst samensmelten van druppels, wat kan worden voorkomen door het gebruik van surfactanten. Surfactanten kunnen echter ook interfereren met of remmen van de biochemische reacties.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f2c254e elementor-widget elementor-widget-image\" data-id=\"f2c254e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img decoding=\"async\" width=\"640\" height=\"127\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1-1024x203.webp\" class=\"attachment-large size-large wp-image-14332\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1-1024x203.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1-300x59.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1-768x152.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1-1536x304.webp 1536w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Flow-focusing-designs-1.webp 1601w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figuur 4 : Flow-focusing. (i) Axisymmetrische flow-focusing-geometrie. (ii) Planar flow-focusing-geometrie. (iii) Microcapillary flow-focusing-apparaat. (iv) Microcapillary apparaat dat co-flow- en flow-focusing-geometrieën combineert. [Zhu et Wang, Lab on Chip, 2017]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-77b2fd0 elementor-widget elementor-widget-image\" data-id=\"77b2fd0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"640\" height=\"76\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1-1024x122.webp\" class=\"attachment-large size-large wp-image-14336\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1-1024x122.webp 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1-300x36.webp 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1-768x91.webp 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1-1536x182.webp 1536w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/Droplet-generation-flow-focusing-1.webp 1600w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figuur 5 : Afbeeldingen van druppelgeneratie met verschillende modi in flow-focusing. (a) Squeezing-modus. (b) Dripping-modus. (c) Jetting-modus. [Zhu et Wang, Lab on Chip, 2017]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cf402bf elementor-widget elementor-widget-text-editor\" data-id=\"cf402bf\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h3>Multichannel dynamic interface</h3><p>De meest klassiek gebruikte geometrieën in microfluïdische druppels zijn flow-focusing en T-junctions. Er moet worden begrepen dat deze technieken verhoogde technische vaardigheden en gespecialiseerde apparatuur vereisen, wat een barrière kan vormen voor laboratoria die niet gespecialiseerd zijn in microfluïdica. Bovendien kan de druppelgrootte worden beïnvloed door vele factoren, zoals vloeistofviscositeit, interfaciale spanning, kanaalgrootte, enz.</p><p>Hier wordt een eenvoudige actieve (elektrische) techniek gebruikt voor het genereren van druppels met behulp van dynamische interfaciale afschuiving die wordt aangestuurd door een mechanisch apparaat (zie fig. 1). Praktisch gezien convergeren vloeibare componenten op de nozzle en genereren ze druppels met de interfaciale afschuiving als gevolg van de trilling van een kanaalcapillair.</p><p>&nbsp;</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ab6cd3b elementor-widget elementor-widget-image\" data-id=\"ab6cd3b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img loading=\"lazy\" decoding=\"async\" width=\"480\" height=\"309\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/multichannel_dynamic_interface_480x480-1.webp\" class=\"attachment-large size-large wp-image-14340\" alt=\"Schema van het multikanaals dynamische grensvlak\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/multichannel_dynamic_interface_480x480-1.webp 480w, https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/multichannel_dynamic_interface_480x480-1-300x193.webp 300w\" sizes=\"(max-width: 480px) 100vw, 480px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Figuur 1 : Schema van de multichannel dynamic interface. Een taps toelopend capillair met 3 kanalen dat is aangesloten op drie spuiten met verschillende componenten, kan trillen aan het olieoppervlak. Vanwege het interfaciale afschuivingsproces worden de druppels gemengd met drie verschillende componenten “geprint” in een 96-well plate. Druppelcomponenten kunnen nauwkeurig worden geregeld door het debiet van discrete kanalen af te stemmen. [Liao et al, American Chemical Society, 2017]</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c77f014 elementor-widget elementor-widget-global elementor-global-18301 elementor-widget-pix-promo-box\" data-id=\"c77f014\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Droplet-generators_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"UW DRUPPELPRODUCTIE OPSCHALEN?\"><div class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Ontdek onze selectie!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">UW DRUPPELPRODUCTIE OPSCHALEN?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Ontdek onze schaalbare oplossingen die ontworpen zijn om gemakkelijk te voldoen aan de eisen van high-throughput druppelgeneratie</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></div></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6b70bdb elementor-widget elementor-widget-text-editor\" data-id=\"6b70bdb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Een van de eerste voordelen is dat het apparaat eenvoudig is gebaseerd op een goedkope vibrator en een handgemaakt taps toelopend meerkanaalscapillair, dat eenvoudig te monteren is en door iedereen kan worden gebruikt zonder enige expertise in druppelgeneratie. Het andere voordeel is dat de techniek uitstekende prestaties levert bij het genereren van uniforme druppels met vooraf ontworpen afmetingen en componenten. Hoewel de productie en montage eenvoudig zijn, kan het feit dat de microkanalen met de hand worden gemaakt een vertekening vormen in de reproduceerbaarheid van het apparaat, maar dit kan ook de grootte beïnvloeden van de druppels die worden gegenereerd door twee verschillende apparaten met dezelfde instellingen. Bovendien is deze techniek beperkt tot een klein aantal biologische toepassingen, zoals bacteriënonderzoek, omdat de drukkeldiameter afneemt naarmate het capillairgetal toeneemt als gevolg van verhoogde viskeuze spanningen die de druppel vervormen.</p><h3>Conclusie</h3><p>In dit overzicht zagen we een zeer klein deel van de bestaande geometrieën en hun variaties om microfluïdische druppels te genereren. Elk daarvan heeft zijn unieke kenmerken op het gebied van stromingsinstabiliteiten, druppelgrootte of druppelgedrag. Voor een effectieve druppelproductie met het gewenste resultaat is het belangrijk om een diepgaand begrip te hebben van de effecten van viskeuze, traagheids- en capillaire krachten. Aangezien de nauwkeurige afhankelijkheid van de druppelgrootte van de stromingsparameters afhangt van de specifieke overwogen geometrie, is het dus belangrijk om rekening te houden met de precieze behoeften en beperkingen van de gewenste onderzoekstoepassing om het perfecte ontwerp voor druppelgeneratie te kiezen.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Platforms based on microfabrication and microfluidics have been successfully utilized in a variety of applications such as drug discovery, polymer chain reaction (PCR), single-cell analysis or crystallization proteins to name a few. For all of these applications, producing droplets at…</p>\n","protected":false},"author":3,"featured_media":14217,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[23,21],"tags":[],"class_list":["post-14324","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-droplet-generation","category-overviews"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>druppelvorming in de microfluïdica: de meest gebruikte ontwerpen</title>\n<meta name=\"description\" content=\"Vandaag de dag is er een breed scala aan geometrieën ontwikkeld die de generatie van druppels mogelijk maken. We zullen ons richten op het meest gebruikte ontwerp.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"druppelvorming in de microfluïdica: de meest gebruikte ontwerpen\">\n<meta property=\"og:description\" content=\"Vandaag de dag is er een breed scala aan geometrieën ontwikkeld die de generatie van druppels mogelijk maken. We zullen ons richten op het meest gebruikte ontwerp.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2023-02-22T11:07:49+00:00\">\n<meta property=\"article:modified_time\" content=\"2024-02-27T11:11:34+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp\">\n\t<meta property=\"og:image:width\" content=\"1000\">\n\t<meta property=\"og:image:height\" content=\"1000\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"8 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"droplet generation in microfluidics: The most used designs\",\"datePublished\":\"2023-02-22T11:07:49+00:00\",\"dateModified\":\"2024-02-27T11:11:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\"},\"wordCount\":1399,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp\",\"articleSection\":[\"Droplet generation\",\"Overviews\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\",\"url\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\",\"name\":\"droplet generation in microfluidics: The most used designs\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp\",\"datePublished\":\"2023-02-22T11:07:49+00:00\",\"dateModified\":\"2024-02-27T11:11:34+00:00\",\"description\":\"Vandaag de dag is er een breed scala aan geometrieën ontwikkeld die de generatie van druppels mogelijk maken. We zullen ons richten op het meest gebruikte ontwerp.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp\",\"width\":1000,\"height\":1000,\"caption\":\"Photograph of a droplet generator from Droplet Genomics\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"droplet generation in microfluidics: The most used designs\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Onze blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/nl\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"droplet generation in microfluidics: The most used designs","description":"Vandaag de dag is er een breed scala aan geometrieën ontwikkeld die de generatie van druppels mogelijk maken. We zullen ons richten op het meest gebruikte ontwerp.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/","og_locale":"en_US","og_type":"article","og_title":"droplet generation in microfluidics: The most used designs","og_description":"Today, a wide range of geometries have been developed, allowing the generation of droplets. We will focus on the most widely used design.","og_url":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/","og_site_name":"Darwin Microfluidics","article_published_time":"2023-02-22T11:07:49+00:00","article_modified_time":"2024-02-27T11:11:34+00:00","og_image":[{"width":1000,"height":1000,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"8 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"droplet generation in microfluidics: The most used designs","datePublished":"2023-02-22T11:07:49+00:00","dateModified":"2024-02-27T11:11:34+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/"},"wordCount":1399,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","articleSection":["Droplet generation","Overviews"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/","url":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/","name":"droplet generation in microfluidics: The most used designs","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","datePublished":"2023-02-22T11:07:49+00:00","dateModified":"2024-02-27T11:11:34+00:00","description":"Vandaag de dag is er een breed scala aan geometrieën ontwikkeld die de generatie van druppels mogelijk maken. We zullen ons richten op het meest gebruikte ontwerp.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","width":1000,"height":1000,"caption":"Photograph of a droplet generator from Droplet Genomics"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/droplet-generation-in-microfluidics-the-most-used-designs/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"droplet generation in microfluidics: The most used designs"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Onze blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2023/02/DG-DM-20angled-1000x1000_2048x2048-1-1.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14324","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=14324"}],"version-history":[{"count":20,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14324/revisions"}],"predecessor-version":[{"id":18450,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/14324/revisions/18450"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/14217"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=14324"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=14324"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=14324"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}