{"id":15987,"date":"2024-02-05T15:25:01","date_gmt":"2024-02-05T14:25:01","guid":{"rendered":"http://eqgkrdm.cluster031.hosting.ovh.net/?p=15987"},"modified":"2026-11-19T15:14:07","modified_gmt":"2026-11-19T14:14:07","slug":"choosing-the-right-materials-for-your-organ-on-a-chip-device","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","title":{"rendered":"Choosing the right materials for your organ-on-a-chip device"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"15987\" class=\"elementor elementor-15987\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-55eda1c3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"55eda1c3\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-433001d0\" data-id=\"433001d0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c2f8cea elementor-widget elementor-widget-text-editor\" data-id=\"c2f8cea\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p></p>\n<p class=\"wp-block-paragraph\">De afgelopen jaren hebben er aanzienlijke ontwikkelingen plaatsgevonden op het gebied van<strong> <a href=\"https://darwin-microfluidics.com/nl/collections/microfluidic-organ-on-a-chip\">organ-on-chip (OoC)-platformen</a></strong>. Er bestaat echter geen universeel 'one-fits-all'-model, en dat zal waarschijnlijk ook nooit het geval zijn gezien de grote verscheidenheid aan toepassingen waarvoor deze devices kunnen worden ingezet. Daarom is het essentieel om rekening te houden met verschillende cruciale parameters bij het selecteren of ontwikkelen van een Organ-on-Chip-platform, zodat het systeem optimaal aansluit bij de te beantwoorden wetenschappelijke vraag. </p>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\"> Wilt u meer weten over organ-on-chip? Lees dan onze review: <strong><a href=\"https://darwin-microfluidics.com/nl/blogs/reviews/organ-on-a-chip-een-algemeen-overzicht\">Organ-On-Chip: a general overview</a></strong>. </p>\n<p></p>\n<p></p>\n<h2 class=\"wp-block-heading\">Ontwerp van het Organ-On-Chip-device</h2>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">Het ontwerp van de chip is een kritisch element bij de ontwikkeling van een OoC-model. Dit hangt af van de specifieke toepassing waarvoor het device zal worden gebruikt. Hierbij worden geometrische parameters bepaald, zoals het aantal, de vorm en de afmetingen van de kanalen, het aantal in- en uitgangen (inlets/outlets), en de aanwezigheid van kweekkamers, poorten of andere elementen die nodig zijn voor het beoogde onderzoek. Biologisch gezien moeten ook het celgetal, de celdichtheid en het vloeistofvolume in overweging worden genomen tijdens het ontwerptrof. Een nauwkeurige definitie van deze elementen draagt bij aan een getrouwe fysiologische modellering van het te onderzoeken orgaan of de cellen.</p>\n<p>Een andere vraag die opkomt bij de implementatie van een OoC-model is de behoefte aan multiplexing – het combineren van meerdere ontwerpen op één platform – wat vaak het formaat van het platform bepaalt. Het toepassen van meerdere replicates op dezelfde chip kan enorm veel tijd besparen en is in bepaalde gevallen, zoals bij drug testing, zelfs noodzakelijk.</p>\n<p>Bij het ontwerp van het platform moet ook rekening worden gehouden met de parameters die de onderzoeker met het platform wil testen of meten. Voor sommige meetresultaten die relevant zijn voor het onderzoek kan toegang tot specifieke delen van de chip nodig zijn om analyses uit te voeren. Om bijvoorbeeld een specifieke biomarker te identificeren, kan het nuttig zijn om in de loop van het onderzoek meerdere keren effluenten te kunnen verzamelen; daarom is het raadzaam om een speciale poort te voorzien voor het eenvoudig verzamelen van media. Ook als er aan het einde van het experiment analyses op de cellen of het weefsel moeten worden uitgevoerd, is het belangrijk dat de cellen of het weefsel van het platform kunnen worden teruggewonnen.</p>\n<p>Tot slot kunnen meer logistieke aspecten, zoals de footprint, de geschiktheid voor gebruik in een incubator, de vloeistofcirculatie en andere factoren, van invloed zijn op de uiteindelijke toepassing en daarmee op het ontwerp van het platform.</p>\n<p></p>\n<p></p>\n<h2 class=\"wp-block-heading\">Hoe kiest u het juiste materiaal voor uw Organ-On-Chip-device?</h2>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">De materiaalkeuze is van groot belang, maar het is niet zo eenvoudig om een materiaal te vinden dat aan alle experimentele eisen voldoet; bij die keuze zullen wellicht compromissen moeten worden gesloten. Tot de parameters die bij deze keuze een rol spelen, behoren uiteraard de biocompatibiliteit, maar ook de gekozen of beschikbare microfabricagestrategie, de eindpunten die het model moet bereiken, de stijfheid van het substraat, de gasdoorlaatbaarheid, overwegingen met betrekking tot massaproductie en nog vele andere factoren.</p>\n<p></p>\n<p></p>\n<h3 class=\"wp-block-heading\">De voornaamste materialen voor Organ-On-Chip-devices</h3>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">Momenteel bestaat er geen perfect ideaal materiaal voor OoC-devices. Over het algemeen geniet het de voorkeur dat het gekozen materiaal niet-toxisch is voor cellen, gasdoorlatend is en optische observatie mogelijk maakt. Er zijn verschillende materiaalsoorten beschikbaar, elk met hun eigen voor- en nadelen op fysisch-chemisch, biologisch, economisch en praktisch vlak.</p>\n<p></p>\n<p></p>\n<p></p>\n<p class=\"wp-block-paragraph\">&nbsp;</p>\n<p></p>\n<p><!-- /wp:list --></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5b11b3b elementor-widget elementor-widget-image\" data-id=\"5b11b3b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"447\" height=\"480\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\" class=\"attachment-large size-large wp-image-18533\" alt=\"tabel met materialen voor organ-on-chips\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp 447w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480-279x300.webp 279w\" sizes=\"(max-width: 447px) 100vw, 447px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-7ead827 elementor-widget elementor-widget-text-editor\" data-id=\"7ead827\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p style=\"color: #252525; letter-spacing: -0.16px;\"><em>Naar Campbell et al., 2021 – Groen: goed, geel: matig, rood: slecht</em></p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Het meest gebruikte materiaal voor microfluïdische chips en OoC is <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://darwin-microfluidics.com/nl/producten/sylgard-184-pdms-elsatomer\">PDMS</a></span> (polydimethylsilaan), hoofdzakelijk vanwege de gebruiksvriendelijkheid, de lage kosten en de optische transparantie. Het vertoont tevens een hoge gasdoorlaatbaarheid, wat zowel een voordeel als een nadeel kan zijn. Hoewel dit zorgt voor een adequate zuurstoftoevoer naar celkweken, kan het ook interfereren met het metabolisme van geneesmiddelen of de productie van metabolieten door weefsels, met een verhoogd risico dat kleine moleculen van belang in de polymeermatrix worden geabsorbeerd.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Andere materialen die veelvuldig worden toegepast bij de fabricage van chips zijn <span style=\"font-weight: bolder;\">thermoplasten.</span> Hun lage kosten, geringe <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">absorptie</a> en optische transparantie vormen grote voordelen voor de (massa)productie van OoC-systemen. De stijfheid van thermoplasten kan echter een obstakel vormen voor fysiologische modellering. In het menselijk lichaam kan de weefselstijfheid dalen tot slechts enkele kPa voor vetweefsel of hersenweefsel, vergeleken met de enkele GPa van gangbare thermoplasten. Bovendien kan het realiseren van complexe geometrieën in thermoplasten complex zijn, wat een beperking kan betekenen voor het chipontwerp.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Een ander materiaal dat voor OoC-devices wordt ingezet is glas. Dit biedt het voordeel van een uitstekende transparantie, inertie, biocompatibiliteit en een lage autofluorescentie. Bovendien kan het glasoppervlak eenvoudig worden gemodificeerd om de celadhesie te sturen. Glazen devices zijn echter aanzienlijk breekbaarder en kostbaarder, en het fabricageproces is arbeidsintensiever.</p>\n<h3 class=\"wp-block-heading\" style=\"font-family: Lato, sans-serif; letter-spacing: -0.16px;\">Sterilisatie van materialen &amp; Oppervlaktebehandeling</h3>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Zodra een materiaal is geselecteerd, rijzen er vraagstukken met betrekking tot de sterilisatie of functionalisering ervan.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Sterilisatie kan noodzakelijk zijn om microbiële contaminatie van het device te voorkomen, aangezien dit de uitgevoerde studie en de betrouwbaarheid van de resultaten kan verstoren. Er bestaan diverse sterilisatietechnieken, zoals autoclaveren, UV-blootstelling, ethanolbehandeling, gammastraling of behandeling met ethyleenoxide. Niet al deze methoden zijn geschikt voor elk van de bovengenoemde materialen. Zo is polycarbonaat (PC) doorgaans probleemloos te autoclaveren, terwijl dit voor PMMA mogelijk niet het geval is. Het is derhalve cruciaal om de juiste sterilisatietechniek te selecteren om beschadiging van het gekozen materiaal te voorkomen.</p>\n<p style=\"color: #252525; letter-spacing: -0.16px;\">Oppervlaktebehandeling kan om verschillende redenen ook een noodzakelijke stap zijn bij de ontwikkeling van OoC-apparatuur: om de biocompatibiliteit te waarborgen en om celhechting te bevorderen of te voorkomen. Ook hier zijn verschillende technieken beschikbaar om dergelijke functies te realiseren, waarbij compatibiliteit met zowel het chipmateriaal als de cellen/weefsels vereist is.</p>\n<h2 class=\"wp-block-heading\" style=\"font-family: Lato, sans-serif; letter-spacing: -0.16px;\">Referenties:</h2>\n<ol style=\"letter-spacing: -0.16px;\">\n<li>Scott B. Campbell, Qinghua Wu, Joshua Yazbeck, Chuan Liu, Sargol Okhovatian, en Milica Radisic – ACS Biomaterials Science & Engineering <span style=\"font-weight: bolder;\">2021</span> <em>7</em> (7), 2880-2899 – DOI: <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://pubs.acs.org/doi/10.1021/acsbiomaterials.0c00640\">10.1021/acsbiomaterials.0c00640</a></span></li>\n<li>Toepke, Michael W., en David J. Beebe.<a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\">„</a>PDMS <a class=\"glossaryLink\" href=\"https://blog.darwin-microfluidics.com/glossary/absorption-microfluidics-explained/\" data-mobile-support=\"0\" data-gt-translate-attributes=\"[{\"attribute\":\"data-cmtooltip\", \"format\":\"html\"}]\" tabindex=\"0\" role=\"link\" data-wg-splitted>e absorptie</a> van kleine moleculen en de gevolgen daarvan voor microfluïdische toepassingen.”<em>Lab on a Chip</em>, nov. 2006.<em>The Royal Society of Chemistry</em>, <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://doi.org/10.1039/b612140c\">https://doi.org/10.1039/b612140c</a></span></li>\n<li>Leung C.M., de Haan, P., Ronaldson-Bouchard, K. <em>et al.</em> A guide to the organe sur puce. <em>Nat Rev Methods Primers</em> <span style=\"font-weight: bolder;\">2</span>, 33 (2022). <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://doi.org/10.1038/s43586-022-00118-6\">https://doi.org/10.1038/s43586-022-00118-6</a></span></li>\n<li>Yanping Wang, Yanfeng Gao, Yongchun Pan, Dongtao Zhou, Yuta Liu, et al., Emerging trends in organe sur puce systems for drug screening, Acta Pharmaceutica Sinica B, Volume 13, Issue 6, 2023, Pages 2483-2509, ISSN 2211-3835, <span style=\"font-weight: bolder;\"><a style=\"font-family: var( --e-global-typography-text-font-family ), Sans-serif; font-weight: var( --e-global-typography-text-font-weight );\" href=\"https://doi.org/10.1016/j.apsb.2023.02.006\">https://doi.org/10.1016/j.apsb.2023.02.006</a></span>.</li>\n</ol>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1ff60da elementor-widget elementor-widget-global elementor-global-18295 elementor-widget-pix-promo-box\" data-id=\"1ff60da\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/17424049-optimized-DDI-Chip_blue2_2048x2048.webp\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"ORGAN-ON-CHIP: DE TOEKOMST VAN ONDERZOEK?\"><a href=\"https://darwin-microfluidics.com/nl/collections/microfluidic-organ-on-a-chip\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Ontdek onze selectie!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">ORGAN-ON-CHIP: DE TOEKOMST VAN ONDERZOEK?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Ontdek onze geavanceerde oplossingen voor innovatief onderzoek en ontwikkeling!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>In de afgelopen jaren hebben er belangrijke ontwikkelingen plaatsgevonden op het gebied van organe sur puce-platforms (OoC). Er bestaat echter geen 'one-size-fits-all'-model, en dat zal er waarschijnlijk ook nooit komen, gezien de verscheidenheid aan toepassingen waarvoor deze devices kunnen worden ingezet. Daarom is het...</p>\n","protected":false},"author":3,"featured_media":18533,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[27,67],"tags":[],"class_list":["post-15987","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-comparisons"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>De juiste materialen kiezen voor je organ-on-a-chip -apparaat</title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"De juiste materialen kiezen voor je organ-on-a-chip -apparaat\">\n<meta property=\"og:description\" content=\"De afgelopen jaren hebben er grote ontwikkelingen plaatsgevonden op het gebied van organ-on-chip (OoC)-platforms. Toch is er geen 'one-fits-all'-model, en dat zal er waarschijnlijk ook nooit komen gezien de variëteit aan toepassingen waarvoor deze apparaten kunnen worden gebruikt. Het is dus...\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-02-05T14:25:01+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:14:07+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\">\n\t<meta property=\"og:image:width\" content=\"447\">\n\t<meta property=\"og:image:height\" content=\"480\">\n\t<meta property=\"og:image:type\" content=\"image/webp\">\n<meta name=\"author\" content=\"Colin Marquet\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Colin Marquet\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"5 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\"},\"author\":{\"name\":\"Colin Marquet\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\"},\"headline\":\"Choosing the right materials for your organ-on-a-chip device\",\"datePublished\":\"2024-02-05T14:25:01+00:00\",\"dateModified\":\"2026-11-19T14:14:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\"},\"wordCount\":1049,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Comparisons &amp; buying guides\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\",\"url\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\",\"name\":\"Choosing the right materials for your organ-on-a-chip device\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"datePublished\":\"2024-02-05T14:25:01+00:00\",\"dateModified\":\"2026-11-19T14:14:07+00:00\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp\",\"width\":447,\"height\":480,\"caption\":\"table of materials for organ on chips\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Choosing the right materials for your organ-on-a-chip device\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Onze blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/nl\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677\",\"name\":\"Colin Marquet\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g\",\"caption\":\"Colin Marquet\"},\"url\":\"https://blog.darwin-microfluidics.com/author/colinmarquet/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Choosing the right materials for your organ-on-a-chip device","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","og_locale":"en_US","og_type":"article","og_title":"Choosing the right materials for your organ-on-a-chip device","og_description":"Over the last few years, there have been major developments in organ-on-chip (OoC) platforms. Yet, there is no &lsquo;one-fits-all&rsquo; model, and probably will never be considering the variety of applications for which those devices can be used. Thus, it is...","og_url":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-02-05T14:25:01+00:00","article_modified_time":"2026-11-19T14:14:07+00:00","og_image":[{"width":447,"height":480,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","type":"image/webp"}],"author":"Colin Marquet","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Colin Marquet","Est. reading time":"5 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/"},"author":{"name":"Colin Marquet","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677"},"headline":"Choosing the right materials for your organ-on-a-chip device","datePublished":"2024-02-05T14:25:01+00:00","dateModified":"2026-11-19T14:14:07+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/"},"wordCount":1049,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","articleSection":["Cell culture &amp; organ-on-chip","Comparisons &amp; buying guides"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","url":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/","name":"Choosing the right materials for your organ-on-a-chip device","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","datePublished":"2024-02-05T14:25:01+00:00","dateModified":"2026-11-19T14:14:07+00:00","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","width":447,"height":480,"caption":"table of materials for organ on chips"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/choosing-the-right-materials-for-your-organ-on-a-chip-device/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Choosing the right materials for your organ-on-a-chip device"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Onze blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/3648e68cd66531dcbc73d2393a720677","name":"Colin Marquet","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/386f7e451a9af705fb0c9215aa09ffbb001606a2d593f42ea0f109080398835b?s=96&d=mm&r=g","caption":"Colin Marquet"},"url":"https://blog.darwin-microfluidics.com/author/colinmarquet/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Campbell_et_al._2021_-_materials_for_organ_on_chip_480x480.webp","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/15987","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/3"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=15987"}],"version-history":[{"count":8,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/15987/revisions"}],"predecessor-version":[{"id":19548,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/15987/revisions/19548"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/18533"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=15987"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=15987"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=15987"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}