{"id":23929,"date":"2024-06-10T14:50:28","date_gmt":"2024-06-10T12:50:28","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=23929"},"modified":"2026-11-19T15:25:03","modified_gmt":"2026-11-19T14:25:03","slug":"how-to-control-a-labv-pump-using-the-modbus-protocol","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/","title":{"rendered":"How to Control a LabV Pump Using the MODBUS Protocol ?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"23929\" class=\"elementor elementor-23929\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-945466f elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"945466f\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e6bfbc6\" data-id=\"e6bfbc6\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-b686b58 elementor-widget elementor-widget-text-editor\" data-id=\"b686b58\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De <strong><a href=\"https://darwin-microfluidics.com/nl/producten/labv1-iii-intelligent-flow-rate-peristaltic-pump\">LabV</a></strong> pompserie van <a href=\"https://darwin-microfluidics.com/nl/zoekresultaten?q=innofluid\"><strong>Innofluid</strong></a> (voorheen bekend als <strong>Shenchen Baoding</strong>) is een geavanceerde serie peristaltische pompen voor stroommeting met een 4,3-inch kleurentouchscreen voor intuïtieve contrôle externe. Het geeft stromingsgegevens, instellingen en systeeminformatie tegelijkertijd weer, met animaties om de werkstatus te tonen. Uitgerust met intelligente kalibratie, online micro-afstelling en drie meetmodi—vast volume, vaste tijd en volume, en timer start/stop—is het uiterst veelzijdig. Compatibel met verschillende pompkoppen en met meerdere opties voor contrôle externe, is de LabV-serie ideaal voor laboratoriumgebruik, apparatuurintegratie en industriële productie.</p><p>In dit blogbericht onderzoeken we hoe u de LabV-pompen kunt aansturen met behulp van het <strong>MODBUS RTU-protocol</strong> via een gebruikelijk programmeerplatform: Python.</p><p>Het is vermeldenswaard dat hoewel er kleine verschillen kunnen zijn in registers en commando's tussen verschillende Lab pump-series (zoals <strong>LabF</strong>, <strong>LabN</strong>, <strong>LabK</strong>, etc.), ze allemaal dezelfde MODBUS RTU-communicatieprotocol gebruiken. Daarom zijn de inzichten in dit artikel relevant en toepasbaar voor gebruikers van elke Innofluid Lab pump-serie.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-90b242d elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"90b242d\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-54151b7\" data-id=\"54151b7\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-9c7f5a9 elementor-widget elementor-widget-heading\" data-id=\"9c7f5a9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Waarom kiezen voor een LabV-serie peristaltische pomp?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-db75143 elementor-widget elementor-widget-text-editor\" data-id=\"db75143\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De LabV peristaltische pomp onderscheidt zich als een uitstekende keuze voor vloeistofbehandeling in zowel laboratoria als industriële omgevingen. Met een nieuwe servomotor voor verbeterde nauwkeurigheid en duurzaamheid, gecombineerd met een 4,3&quot; LCD-touchscreeninterface, biedt deze pomp intuïtieve contrôle externe voor nauwkeurige dosering en modi met een vast volume. Gemaakt van laboratorium-grade ABS, garandeert hij zowel gebruiksgemak als robuuste prestaties.</p><p>Met debieten van 0,0053 µL/min tot 775 mL/min en de flexibiliteit om tot 8 kanalen te ondersteunen, is hij geschikt voor een breed scala aan toepassingen. Bovendien maken zijn industriële constructie, dynamische display en intelligente kalibratiefunctionaliteit hem tot een betrouwbare aanwinst voor diverse vloeistoftranstaken.</p><p>Of het nu gaat om onderzoek, ondersteuning van apparatuur of industriële productie, de LabV-serie peristaltische pompen vormt een zeer goede oplossing voor uitdagingen op het gebied van vloeistofbehandeling.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-be2b383 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"be2b383\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-722f9ad\" data-id=\"722f9ad\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e3b3085 elementor-widget elementor-widget-heading\" data-id=\"e3b3085\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wat heb je nodig om te communiceren met een LabV-pomp?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ae42d9 elementor-widget elementor-widget-text-editor\" data-id=\"5ae42d9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Om te communiceren met een LabV-pomp via het MODBUS RTU-protocol, heb je het volgende nodig:</p><ul><li>Een LabV-pomp (hier wordt een <a href=\"https://darwin-microfluidics.com/nl/producten/labv1-iii-intelligent-flow-rate-peristaltic-pump\">LabV1-III Intelligent Flow Rate Peristaltic Pump</a> voor gebruikt) met een <a href=\"https://darwin-microfluidics.com/nl/collections/pompkoppen-voor-peristaltische-pompen\">pump head</a> en een <a href=\"https://darwin-microfluidics.com/nl/collections/slangen-voor-peristaltische-pompen\">tube</a> naar keuze</li><li>Een <a href=\"https://darwin-microfluidics.com/nl/producten/usb-to-rs485-serial-converter-cable/\">serial cable</a> die kan worden aangesloten op je computer of apparaat</li><li>Een RS485- of RS232-bedrading op de contrôle externe-poort aan de achterkant van de pomp</li><li>Een programmeerplatform (in dit geval Python)</li><li>Een basisbegrip van het MODBUS RTU-communicatieprotocol dat <a href=\"#modbus\">hieronder 👇</a> wordt beschreven.</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e9139aa elementor-widget elementor-widget-global elementor-global-18316 elementor-widget-pix-promo-box\" data-id=\"e9139aa\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta1\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Tubing_1920x600_DARWIN_MICROFLUIDICS.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"OP ZOEK NAAR FLEXIBILITEIT IN TUBE-OPTIES?\"><a href=\"https://darwin-microfluidics.com/nl/collections/microfluidic-slangen\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Ontdek onze selectie!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">OP ZOEK NAAR FLEXIBILITEIT IN TUBE-OPTIES?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Ontdek onze microfluïdische tube-oplossingen voor een betrouwbare en efficiënte vloeistofstroom in uw experimenten!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-7a61ab4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"7a61ab4\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a46e079\" data-id=\"a46e079\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5b9a150 elementor-widget elementor-widget-heading\" data-id=\"5b9a150\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hoe configureert u de communicatiepoort?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-26a39db elementor-widget elementor-widget-text-editor\" data-id=\"26a39db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Voordat u data kunt verzenden en ontvangen van de pomp, moet u de communicatiepoort correct instellen. Volg hiervoor de volgende stappen:</p><ul><li>Sluit de kabel aan voor de RS232- of RS485-communicatie op de contrôle externe-poort aan de achterkant van de pomp</li><li>Zet de pomp aan</li><li>Kies in de <a href=\"#communication_interface\">communication setting interface</a> op het pompscherm RS232 of RS485 als uw communicatie-interface (details van de RS232- en RS485-bedrading worden weergegeven in de <a href=\"#wiring\">tabellen</a> hieronder)</li><li>Ongeacht of je kiest voor RS232 of RS485, het communicatieprotocol is standaard MODBUS RTU</li><li>Stel de baudrate in</li><li>Klik op de knop <strong>Slave No.</strong> om het adres van de peristaltische pomp in te stellen (bereik: 1-32)</li><li>Selecteer communicatie inschakelen <strong>ON</strong></li><li><strong><em>Keer terug naar de hoofdinterface aangezien de pomp alleen communicatiecontrôle externe ontvangt wanneer deze zich in de hoofdinterface bevindt; contrôle externe in andere instellingsinterfaces is ongeldig.</em></strong></li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3ad7815 elementor-widget elementor-widget-image\" data-id=\"3ad7815\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"communication_interface\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"384\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/06/communication-interface-1024x614.png\" class=\"attachment-large size-large wp-image-24348\" alt=\"Een schermafbeelding van de communicatie-instellingeninterface van de LabV1-III pomp\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/06/communication-interface-1024x614.png 1024w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/06/communication-interface-300x180.png 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/06/communication-interface-768x460.png 768w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/06/communication-interface.png 1153w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5217f89 elementor-widget elementor-widget-text-editor\" data-id=\"5217f89\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"wiring\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\n\n<table>\n    <thead>\n        <tr>\n            <th colspan=\"2\" class=\"section-header\">RS232-bedradingsdetails</th>\n        </tr>\n        <tr>\n            <th class=\"smaller-column\">Aansluiting</th> <!-- Apply class to first column -->\n            <th>Beschrijving</th>\n        </tr>\n    </thead>\n    <tbody>\n        <tr>\n            <td>GND</td>\n            <td>Communicatie-aardeaansluiting.</td>\n        </tr>\n        <tr>\n            <td>TXD</td>\n            <td>Hoofdzender, signaalontvangstaansluiting van de peristaltische pomp.</td>\n        </tr>\n        <tr>\n            <td>RXD</td>\n            <td>Peristaltische pomp verzendt, master ontvangt signaalterminal.</td>\n        </tr>\n    </tbody>\n</table>\n\n<table>\n    <thead>\n        <tr>\n            <th colspan=\"2\" class=\"section-header\">RS485 Bedradingsdetails</th>\n        </tr>\n        <tr>\n            <th class=\"smaller-column\">Aansluiting</th> <!-- Apply class to first column -->\n            <th>Beschrijving</th>\n        </tr>\n    </thead>\n    <tbody>\n        <tr>\n            <td>GD1</td>\n            <td>RS485 signaalmassa.</td>\n        </tr>\n        <tr>\n            <td>A+</td>\n            <td>Verbind met de RS485 A+-terminal.</td>\n        </tr>\n        <tr>\n            <td>B-</td>\n            <td>Verbind met de RS485 B--terminal.</td>\n        </tr>\n    </tbody>\n</table>\n\n\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-86803c4 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"86803c4\" data-element_type=\"section\" data-e-type=\"section\" id=\"modbus\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-6418f5a\" data-id=\"6418f5a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-26f7418 elementor-widget elementor-widget-heading\" data-id=\"26f7418\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Het MODBUS RTU-communicatieprotocol voor de LabV-serie</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a3697f elementor-widget elementor-widget-text-editor\" data-id=\"0a3697f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De LabV-serie peristaltische pompen biedt een uitgebreide opdrachtset voor nauwkeurige besturing en monitoring via het MODBUS RTU-protocol. Deze opdrachtset omvat diverse gecategoriseerde instructies om de functionaliteiten van de pomp te manipuleren, zoals het instellen van de motorsnelheid, het configureren van het debiet, het selecteren van de pompkop en het uitvoeren van kaloratieroutines. Elke opdracht, geïdentificeerd door unieke parameters, zorgt voor een nauwkeurige controle over de werking van de pomp.</p><p>Gedetailleerde uitleg en verdere informatie met betrekking tot het MODBUS RTU-protocol voor de aansturing van de LabV-pompen worden hieronder vermeld en zijn tevens te vinden in de <a href=\"https://darwin-microfluidics.com/content/pdfs/Lab-V-Series-MODBUS-Protocol.pdf\" target=\"_blank\" rel=\"noopener\">documentatie van het communicatieprotocol</a>.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8fcce94 elementor-widget elementor-widget-heading\" data-id=\"8fcce94\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Standaard MODBUS RTU-communicatieformaat</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9b4fe20 elementor-widget elementor-widget-text-editor\" data-id=\"9b4fe20\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De berichtstructuur komt overeen met het formaat dat in onderstaande tabel is weergegeven. </p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-590b794 elementor-widget elementor-widget-text-editor\" data-id=\"590b794\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table><tbody><tr><th>Veld</th><th>Maat</th><th>Beschrijving</th></tr><tr><td>Slave-adres</td><td>1 byte</td><td>Adres van de pomp. Het bereik is 1-32 en 0 wordt gebruikt voor broadcast.</td></tr><tr><td>Functiecode</td><td>1 byte</td><td>Instructie voor het slave-apparaat.<br><strong>03H</strong>: Houdregisters lezen<br><strong>06H</strong>: Enkel register schrijven<br><strong>10H</strong>: Meerdere registers schrijven<br><strong>02H</strong>: Discrete ingangen lezen (datakits lezen)<br><strong>05H</strong>: Enkele bit naar register schrijven</td></tr><tr><td>Datagebied</td><td>0 – 252 bytes</td><td>Te verzenden data (variabele lengte)</td></tr><tr><td>CRC-controle</td><td>2 bytes</td><td>Cyclic Redundancy Check voor foutdetectie<br>CRC laag (1 Byte): Lagere byte van de CRC<br>CRC hoog (1 Byte): Hogere byte van de CRC</td></tr></tbody></table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-380bcf6 elementor-widget elementor-widget-heading\" data-id=\"380bcf6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">CRC-controle met CRC-16 in Python</h4>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5ca75b1 elementor-widget elementor-widget-text-editor\" data-id=\"5ca75b1\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>CRC (Cyclic Redundancy Check) is een essentiële techniek voor het detecteren van fouten in datatransmissie. Hieronder demonstreren we hoe u CRC-16, zoals gebruikt in het Amerikaanse binaire synchrone systeem, kunt implementeren in Python.\n\nBij CRC-16 maakt het foutdetectie-algoritme gebruik van een polynoom <span style=\"background-color: lightgray;\">G(X) = X<sup>16</sup> + X<sup>15</sup> + X<sup>2</sup> + 1</span> om de checksum te genereren. Dit polynoom definieert de wiskundige bewerkingen die worden uitgevoerd op de bits van het bericht tijdens het berekeningsproces van de CRC. Hieronder volgt een overzicht van het algoritme:\n</p><ul>\n \t<li>Initialiseer een 16-bits register met de hexadecimale waarde FFFF (allemaal enen), aangeduid als het CRC-register.</li>\n \t<li>Voer een XOR-bewerking uit op de eerste 8 bytes van het bericht met de lage byte van het CRC-register. Sla het resultaat op in het CRC-register.</li>\n \t<li>Schuif het CRC-register één bit naar rechts, waarbij de meest significante bit (MSB) op nul wordt gezet.</li>\n \t<li>Controleer de minst significante bit (LSB) van het CRC-register:\n<ul>\n \t<li>Als de LSB 0 is, herhaal stap 3 (schuifoperatie).</li>\n \t<li>Als de LSB 1 is, voer dan een XOR-bewerking uit op het CRC-register met de polynoomwaarde 0xA001 (1010 0000 0000 0001).</li>\n</ul>\n</li>\n \t<li>Herhaal stap 3-4, in totaal 8 verschuivingen, om elke byte te verwerken.</li>\n \t<li>Herhaal stap 2-5 voor elke byte in het bericht totdat alle bytes zijn verwerkt.</li>\n \t<li>De uiteindelijke inhoud van het CRC-register is de CRC-waarde.</li>\n</ul>\n🚨 <em>In het bericht moeten de hoge en lage bytes van de CRC-waarden worden omgewisseld.</em>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-262e27e elementor-widget elementor-widget-heading\" data-id=\"262e27e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Communicatie-instellingen</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b164570 elementor-widget elementor-widget-text-editor\" data-id=\"b164570\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Elke databyte heeft een structuur bestaande uit 1 startbit, 8 databits, 1 pariteitsbit en 1 stopbit. Bits worden verzonden in volgorde van de minst significante bit (LSB) naar de meest significante bit (MSB). De mogelijke communicatiebaudrates zijn onder andere 1200, 2400, 4800 en 9600 bits/s.</p><p>Voor integers (2 bytes) worden de gegevens zo gerangschikt dat de tweede byte eerst komt, gevolgd door de eerste byte. De hexadecimale waarde 2378H wordt bijvoorbeeld verzonden als 23H 78H. Voor long integers en floats (4 bytes) worden de gegevens gerangschikt met de vierde byte als eerste, gevolgd door de derde, tweede en eerste byte.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b0b1a1b elementor-widget elementor-widget-heading\" data-id=\"b0b1a1b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">MODBUS-bericht RTU-frame-indeling</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1e40ee2 elementor-widget elementor-widget-text-editor\" data-id=\"1e40ee2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De RTU-frame-indeling van het MODBUS-bericht is zoals beschreven in de onderstaande tabel. </p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c2be73c elementor-widget elementor-widget-text-editor\" data-id=\"c2be73c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table><tbody><tr><th>Veld</th><th>Maat</th><th>Beschrijving</th></tr><tr><td>Start</td><td>≥ 3,5 tekens</td><td>Geeft het begin van de transmissie aan</td></tr><tr><td>Adres</td><td>8 Bits</td><td>Adres van het slave-apparaat</td></tr><tr><td>Functiecode</td><td>8 Bits</td><td>Instructie voor het slave-apparaat</td></tr><tr><td>Data</td><td>N x 8 bits</td><td>Te verzenden data (variabele lengte, N bytes)</td></tr><tr><td>CRC-controlecode</td><td>16 bits</td><td>Cyclic Redundancy Check voor foutdetectie</td></tr><tr><td>Einde</td><td>≥ 3,5 tekens</td><td>Geeft het einde van de transmissie aan</td></tr></tbody></table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-14e516f elementor-widget elementor-widget-text-editor\" data-id=\"14e516f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>🚨 Zorg ervoor dat het berichtframe continu wordt verzonden zonder inactieve tussenpozen tussen karakters die groter zijn dan 1,5 karaktertijd. Onvolledige berichtframes, aangegeven door een te lange inactieve tussenpoze, moeten door het ontvangende knooppunt worden genegeerd.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1dae4c6 elementor-widget elementor-widget-heading\" data-id=\"1dae4c6\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Abnormale reactie</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e5d5fb4 elementor-widget elementor-widget-text-editor\" data-id=\"e5d5fb4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Wanneer een host een gegevensaanvraag verzendt en de slave abnormale data ontvangt, dient dit een abnormale reactie te activeren. Als de adrescode verzonden door de host onjuist is, wat betekent dat deze niet overeenkomt met een adrescode van de slaves, of als de door de slave ontvangen data niet door de CRC-controle komt, wordt er geen foutcode geretourneerd. In dergelijke gevallen dient de host een hoger niveau reactieproces te starten.</p><p>In het functiecodegebied wordt de functiecode voor de abnormale reactie gedefinieerd als de normale functiecode vermeerderd met 80H.</p><p>In het datagebied wordt de te retourneren foutcode gedefinieerd zoals weergegeven in onderstaande tabel.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e40c00f elementor-widget elementor-widget-text-editor\" data-id=\"e40c00f\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table>\n<tbody>\n<tr>\n<th>Code</th>\n<th>Naam</th>\n<th>Betekenis</th>\n</tr>\n<tr>\n<td>01H</td>\n<td>Ongeldige functiecode</td>\n<td>De door de peristaltische pomp ontvangen functiecode is niet toegestaan, met uitzondering van 03H, 06H of 10H.</td>\n</tr>\n<tr>\n<td>02H</td>\n<td>Ongeldig data-adres</td>\n<td>Het door de peristaltische pomp ontvangen registeradres is niet toegestaan.</td>\n</tr>\n<tr>\n<td>03H</td>\n<td>Ongeldige datawaarde</td>\n<td>De geschreven data voldoet niet aan het bereik dat door de peristaltische pomp wordt verwacht.</td>\n</tr>\n<tr>\n<td>06H</td>\n<td>Slave (peristaltische pomp) bezet</td>\n<td>De peristaltische pomp is momenteel bezet en kan de opdracht niet voltooien vanwege een conflicterende status.</td>\n</tr>\n</tbody>\n</table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-576496b elementor-widget elementor-widget-text-editor\" data-id=\"576496b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em> 🚨De peristaltische pomp accepteert <strong>alleen</strong> MODBUS-commando's via de <strong>Main Interface</strong>; andere interfaces ontvangen geen berichten.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1df5e34 elementor-widget elementor-widget-heading\" data-id=\"1df5e34\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Adres en inhoud van Holding Register</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b7d2fc9 elementor-widget elementor-widget-text-editor\" data-id=\"b7d2fc9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Hieronder staan de tabellen met de instellingen voor respectievelijk de basisparameters en de kalibratieparameters.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-55231ab elementor-widget elementor-widget-heading\" data-id=\"55231ab\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Instelling van basisparameters</h4>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b191150 elementor-widget elementor-widget-text-editor\" data-id=\"b191150\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table><tbody><tr><th>Adres (Decimaal)</th><th>Naam</th><th>Bereik</th><th>Gegevenstype</th></tr><tr><td>1000</td><td>Pompkop</td><td>Met betrekking tot <a href=\"#chart\">Grafiek 1</a></td><td>unsigned short int (2 Bytes)</td></tr><tr><td>1001</td><td>Slangmaat</td><td>Met betrekking tot <a href=\"#chart\">Grafiek 1</a></td><td>unsigned short int (2 Bytes)</td></tr><tr><td>1002</td><td>Motorsnelheid</td><td>0,1-600 rpm</td><td>float (4 Bytes)</td></tr><tr><td>1004</td><td>debiet</td><td>0,1-99999 mL</td><td>float (4 Bytes)</td></tr><tr><td>1007</td><td>Terugzuighoek</td><td>0-360°</td><td>unsigned short int (2 Bytes)</td></tr><tr><td>1008</td><td>Start-/stopbesturing</td><td>1: Start, 0: Stop</td><td>unsigned short int (2 Bytes)</td></tr><tr><td>1009</td><td>Richtingsturing</td><td>1: Met de klok mee, 0: Tegen de klok in</td><td>unsigned short int (2 Bytes)</td></tr><tr><td>1010</td><td>Volledige snelheid</td><td>1: Start volledige snelheid, 0: Stop volledige snelheid</td><td>unsigned short int (2 Bytes)</td></tr><tr><td>1015</td><td>Stel debiet in</td><td>0-99999 mL</td><td>float (4 Bytes)</td></tr><tr><td>1018</td><td>Werktijd</td><td>0,1-9999 s</td><td>float (4 Bytes)</td></tr><tr><td>1020</td><td>Werkmodus</td><td>0: Overdragen, 1: Vaste volume-meting, 2: Vaste tijd en volume</td><td>unsigned short int (2 Bytes)</td></tr><tr><td>1021</td><td>Pauzetijd</td><td>0,1-9999 s</td><td>float (4 Bytes)</td></tr><tr><td>1023</td><td>Aantal herhalingen</td><td>0-9999 keer, 0 betekent oneindig</td><td>unsigned short int (2 Bytes)</td></tr></tbody></table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-babad56 elementor-widget elementor-widget-text-editor\" data-id=\"babad56\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>💡 Belangrijke opmerkingen:</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-0a125de elementor-widget elementor-widget-text-editor\" data-id=\"0a125de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Registers 1015 en 1018 zijn ongeldig wanneer de werkmodus is ingesteld op overdragen.</li><li>Register 1018 is ongeldig wanneer de werkmodus is ingesteld op vaste volume-meting.</li><li>Registers 1002 en 1004 zijn ongeldig wanneer de werkmodus is ingesteld op vaste tijd en volume.</li><li>Zorg ervoor dat de registergegevens worden ingesteld volgens de meegeleverde tabel en vermijd het verzenden van meerdere registerinstellingen in één enkele opdracht.</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-bb95a83 elementor-widget elementor-widget-heading\" data-id=\"bb95a83\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Instelling van kalibratieparameters</h4>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9fd118 elementor-widget elementor-widget-text-editor\" data-id=\"a9fd118\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table>\n<tbody>\n<tr>\n<th>Adres (Decimaal)</th>\n<th>Naam</th>\n<th>Bereik</th>\n<th>Gegevenstype</th>\n</tr>\n<tr>\n<td>2001</td>\n<td>Testtijd</td>\n<td>0,5-9999 s</td>\n<td>unsigned short int (2 Bytes)</td>\n</tr>\n<tr>\n<td>2002</td>\n<td>Start/Stop test</td>\n<td>1: Start, 0: Stop</td>\n<td>unsigned short int (2 Bytes)</td>\n</tr>\n<tr>\n<td>2003</td>\n<td>Actueel volume</td>\n<td>0-9999 mL</td>\n<td>float (4 Bytes)</td>\n</tr>\n<tr>\n<td>2005</td>\n<td>Standaardwaarden herstellen</td>\n<td>1: Kalibratie herstellen</td>\n<td>unsigned short int (2 Bytes)</td>\n</tr>\n<tr>\n<td>2006</td>\n<td>Fijnafstelling</td>\n<td>1: Verhogen, 0: Verlagen</td>\n<td>unsigned short int (2 Bytes)</td>\n</tr>\n</tbody>\n</table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-252d9bc elementor-widget elementor-widget-heading\" data-id=\"252d9bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Overzichtstabel pompkop en tube</h4>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-25f8eba elementor-widget elementor-widget-text-editor\" data-id=\"25f8eba\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"chart\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table>\n  <tbody>\n    <tr>\n      <th>Naam pompkop</th>\n      <th>Type pompkop</th>\n      <th>Slangmaat</th>\n      <th>Specifieke tube</th>\n    </tr>\n    <tr>\n      <td rowspan=\"7\">EasyPumpI</td>\n      <td rowspan=\"7\">0</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"4\">EasyPumpII</td>\n      <td rowspan=\"4\">1</td>\n      <td>15</td>\n      <td>15#</td>\n    </tr>\n    <tr>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n    <tr>\n      <td>35</td>\n      <td>35#</td>\n    </tr>\n    <tr>\n      <td>36</td>\n      <td>36#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"7\">EasyPumpIII</td>\n      <td rowspan=\"7\">2</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"4\">EasyPumpIV</td>\n      <td rowspan=\"4\">3</td>\n      <td>15</td>\n      <td>15#</td>\n    </tr>\n    <tr>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n    <tr>\n      <td>35</td>\n      <td>35#</td>\n    </tr>\n    <tr>\n      <td>36</td>\n      <td>36#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"5\">EasyPumpV</td>\n      <td rowspan=\"5\">4</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"5\">EasyPumpVI</td>\n      <td rowspan=\"5\">5</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"7\">2*EasyPumpI</td>\n      <td rowspan=\"7\">6</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"4\">2*EasyPumpII</td>\n      <td rowspan=\"4\">7</td>\n      <td>15</td>\n      <td>15#</td>\n    </tr>\n    <tr>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n    <tr>\n      <td>35</td>\n      <td>35#</td>\n    </tr>\n    <tr>\n      <td>36</td>\n      <td>36#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"7\">2*EasyPumpIII</td>\n      <td rowspan=\"7\">8</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n\n    <tr>\n      <td rowspan=\"7\">YZ1515x</td>\n      <td rowspan=\"7\">12</td>\n      <td>13</td>\n      <td>13#</td>\n    </tr>\n    <tr>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"2\">YZ2515x</td>\n      <td rowspan=\"2\">13</td>\n      <td>15</td>\n      <td>15#</td>\n    </tr>\n    <tr>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n\n\n    <tr>\n      <td rowspan=\"4\">DZ25-3L</td>\n      <td rowspan=\"4\">18</td>\n      <td>15</td>\n      <td>15#</td>\n    </tr>\n    <tr>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n    <tr>\n      <td>35</td>\n      <td>35#</td>\n    </tr>\n    <tr>\n      <td>36</td>\n      <td>36#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"5\">UC15</td>\n      <td rowspan=\"5\">20</td>\n      <td>19</td>\n      <td>19#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td>25</td>\n      <td>25#</td>\n    </tr>\n    <tr>\n      <td>17</td>\n      <td>17#</td>\n    </tr>\n    <tr>\n      <td>18</td>\n      <td>18#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"3\">UC25</td>\n      <td rowspan=\"3\">21</td>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n    <tr>\n      <td>35</td>\n      <td>35#</td>\n    </tr>\n    <tr>\n      <td>36</td>\n      <td>36#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"2\">SN15</td>\n      <td rowspan=\"2\">22</td>\n      <td>14</td>\n      <td>14#</td>\n    </tr>\n    <tr>\n      <td>16</td>\n      <td>16#</td>\n    </tr>\n    <tr>\n      <td rowspan=\"1\">SN25</td>\n      <td rowspan=\"1\">23</td>\n      <td>24</td>\n      <td>24#</td>\n    </tr>\n  </tbody>\n</table>\n\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3c77785 elementor-widget elementor-widget-text-editor\" data-id=\"3c77785\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>💡 Belangrijke opmerking:</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-54d3317 elementor-widget elementor-widget-text-editor\" data-id=\"54d3317\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>De bovenstaande tabel is niet volledig en bevat slechts een selectie van pompkoppen en tubematen. Raadpleeg de documentatie voor de volledige lijst.</li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5e5e0a2 elementor-widget elementor-widget-heading\" data-id=\"5e5e0a2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Voorbeelden van opdrachtreeksen</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3fbb3ff elementor-widget elementor-widget-text-editor\" data-id=\"3fbb3ff\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Voorbeeld 1: Start de pomp</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5a05e55 elementor-widget elementor-widget-text-editor\" data-id=\"5a05e55\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Adres: <strong>01</strong>, geeft het apparaatadres aan waarnaar de opdracht wordt verzonden.</li><li>Functiecode: <strong>06</strong>, wordt gebruikt om een enkele waarde naar een register te schrijven.</li><li>Registeradres: <strong>03F0</strong>, registeradres dat overeenkomt met het stuurregister voor het starten van de pomp (1008 in hexadecimaal).</li><li>Data: <strong>0001</strong>, geschreven naar het register om de pomp te starten (1: Start, 0: Stop).</li><li>CRC: <strong>487D</strong>, waarde die wordt gebruikt om de integriteit van de data te waarborgen.</li></ul><p>De bijbehorende opdrachtreeks om de pomp te starten is daarom: <strong>01 06 03 F0 00 01 48 7D</strong>.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1dfded8 elementor-widget elementor-widget-text-editor\" data-id=\"1dfded8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Voorbeeld 2: De pompsnelheid instellen op 20 rpm</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f483acb elementor-widget elementor-widget-text-editor\" data-id=\"f483acb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul><li>Adres: <strong>01</strong>, geeft het apparaatadres aan waarnaar de opdracht wordt verzonden.</li><li>Functiecode: <strong>10</strong>, wordt gebruikt om waarden naar meerdere registers te schrijven.</li><li>Registeradres: <strong>03EA</strong>, registeradres dat overeenkomt met het snelheidsinstellingsregister (1002 in hexadecimaal).</li><li>Aantal registers: <strong>0002</strong>, er wordt naar twee registers geschreven.</li><li>Aantal bytes: <strong>04</strong>, het aantal te schrijven databytes.</li><li>Data: <strong>41A00007</strong>, vertegenwoordigt de snelheidsinstelling in float-formaat die overeenkomt met 20 RPM.</li><li>CRC: <strong>D76E</strong>, waarde die wordt gebruikt om de integriteit van de data te waarborgen.</li></ul><p>De bijbehorende opdrachtreeks om de pompsnelheid in te stellen op 20 rpm is daarom: <strong>01 10 03 EA 00 02 04 41 A0 00 07 D7 6E</strong>.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-898c1b9 elementor-widget elementor-widget-text-editor\" data-id=\"898c1b9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Deze 2 voorbeelden en andere voorbeelden van opdrachtreeksen worden weergegeven in onderstaande tabel.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-35b72b2 elementor-widget elementor-widget-text-editor\" data-id=\"35b72b2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<table>\n<tbody>\n<tr>\n<th>Taak</th>\n<th>Opdrachtreeks</th>\n</tr>\n<tr>\n<td>Pomp starten</td>\n<td>01 06 03 F0 00 01 48 7D</td>\n</tr>\n<tr>\n<td>Richting instellen op CCW</td>\n<td>01 06 03 F1 00 00 D8 7D</td>\n</tr>\n<tr>\n<td>Richting instellen op CW</td>\n<td>01 06 03 F1 00 01 19 BD</td>\n</tr>\n<tr>\n<td>Snelheid instellen op 20 RPM</td>\n<td>01 10 03 EA 00 02 04 41 A0 00 07 D7 6E</td>\n</tr>\n<tr>\n<td>Debiet instellen op 50,0 mL/min</td>\n<td>01 10 03 EC 00 02 04 42 48 00 00 7D 2C</td>\n</tr>\n<tr>\n<td>Pomp stoppen</td>\n<td>01 06 03 F0 00 00 89 BD</td>\n</tr>\n<tr>\n<td>Start volheid toeren</td>\n<td>01 06 03 F2 00 01 E9 BD</td>\n</tr>\n</tbody>\n</table>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-91454a9 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"91454a9\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-e1fd1c0\" data-id=\"e1fd1c0\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0196ace elementor-widget elementor-widget-heading\" data-id=\"0196ace\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hoe stuur je de LabV pompen aan met Python?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24bb349 elementor-widget elementor-widget-text-editor\" data-id=\"24bb349\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De LabV pompserie kan op afstand worden aangestuurd met behulp van het MODBUS RTU-protocol via Python, wat grotere flexibiliteit en gemak biedt voor het uitvoeren van complexe pompprogramma's met lussen, pauzes en variërende snelheden/debieten. Deze benadering is met name nuttig bij het integreren van meerdere apparaten, omdat het de automatisering mogelijk maakt van sequenties waarbij al de aangesloten apparatuur betrokken is.</p><p>In dit gedeelte wordt een toegewijde aangepaste Python-bibliotheek geïntroduceerd die gebruikmaakt van het MODBUS RTU-protocol, waarmee men de seriële poort kan openen en besturingscommando's kan verzenden naar de LabV pomp. We behandelen voorbeelden die laten zien hoe u de snelheid instelt, de pomp start en stopt, pompkop en slangmaat configureert, enz., waarmee we een praktische gids bieden voor het gebruik van Python bij de contrôle externe van een LabV pomp.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c485fe4 elementor-widget elementor-widget-text-editor\" data-id=\"c485fe4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>🚨🚨🚨 Belangrijke opmerking</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-9e8210c elementor-widget elementor-widget-text-editor\" data-id=\"9e8210c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>When viewing this code, please be aware that <strong><span style=\"color: red;\">&lt;</span></strong>, <strong><span style=\"color: red;\">&gt;</span></strong>, and <strong><span style=\"color: red;\">&amp;</span></strong> symbols might not display correctly due to formatting issues. These should appear as standard Python code syntax, so make sure to interpret <strong><span style=\"color: red;\">&amp;lt;</span></strong> as <strong><span style=\"color: red;\">&lt;</span></strong>,<strong> <span style=\"color: red;\">&amp;gt;</span></strong> as <strong><span style=\"color: red;\">&gt;</span></strong>, and <strong><span style=\"color: red;\">&amp;amp;</span></strong> as <strong><span style=\"color: red;\">&amp;</span></strong>.</li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ce25554 elementor-widget elementor-widget-code-highlight\" data-id=\"ce25554\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"code-highlight.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"prismjs-tomorrow copy-to-clipboard \">\n\t\t\t<pre data-line=\"\" class=\"highlight-height language-python line-numbers\">\n\t\t\t\t<code readonly=\"\" class=\"language-python\">\n\t\t\t\t\t<xmp>'''\r\n-----------------------------------------------------------\r\nLABV Peristaltic Pump Control Library Using Modbus Protocol\r\n-----------------------------------------------------------\r\n'''\r\n\r\nimport serial\r\nimport struct\r\n\r\n#------------------------------------------------------#\r\n#   LIBRARY MANAGING THE COMMUNICATION WITH THE PUMP   #\r\n#------------------------------------------------------#\r\n\r\nclass LABV:\r\n    \r\n    # Initialize the object and establish a serial connection with the corresponding data format\r\n    def __init__(self, port, address=1, baudrate=9600, parity='E', bytesize=8, stopbits=1, timeout=1):\r\n        self.ser = serial.Serial(port=port, baudrate=baudrate, parity=parity,\r\n                                 bytesize=bytesize, stopbits=stopbits, timeout=timeout)\r\n        self.address = address\r\n\r\n    # Connect the pump\r\n    def connect(self):\r\n        if not self.ser.is_open:\r\n            self.ser.open()\r\n\r\n    # Close the serial connection\r\n    def disconnect(self):\r\n        if self.ser.is_open:\r\n            self.ser.close()\r\n\r\n    # Calculate the CRC (Cyclic Redundancy Check) for data integrity as\r\n    # explained in \"The MODBUS RTU Communication Protocol\" section\r\n    def _calculate_crc(self, data):\r\n        crc = 0xFFFF\r\n        for byte in data:\r\n            crc ^= byte\r\n            for _ in range(8):\r\n                if crc &amp; 0x0001:\r\n                    crc &gt;&gt;= 1\r\n                    crc ^= 0xA001\r\n                else:\r\n                    crc &gt;&gt;= 1\r\n        return crc.to_bytes(2, byteorder='little')\r\n\r\n    # Convert data into bytes for communication\r\n    def _prepare_data(self, data, data_type):\r\n        if data_type == 'float':\r\n            return struct.pack('&gt;f', data)\r\n        elif data_type == 'int':\r\n            return data.to_bytes(2, byteorder='big')\r\n        else:\r\n            raise ValueError(\"Data type not supported.\")\r\n\r\n    # Construct, send commands to the pump and verify the response\r\n    def _send_command(self, function_code, register_address, data, data_type):\r\n        data_bytes = self._prepare_data(data, data_type)\r\n        payload = bytearray([self.address, function_code])\r\n        payload.extend(register_address.to_bytes(2, byteorder='big'))\r\n\r\n        if function_code == 0x10:  # Write multiple registers\r\n            number_of_registers = len(data_bytes) // 2\r\n            payload.extend(number_of_registers.to_bytes(2, byteorder='big'))\r\n            payload.append(len(data_bytes))\r\n            payload.extend(data_bytes)\r\n        else:\r\n            payload.extend(data_bytes)\r\n\r\n        crc = self._calculate_crc(payload)\r\n        payload.extend(crc)\r\n        print(f\"Sending payload: {payload.hex()}\")  # Debug: Print the payload\r\n\r\n        self.ser.write(payload)\r\n        response = self.ser.read(8) # Adjust as per the device response length\r\n        if len(response) != 8:\r\n            raise ValueError(\"Invalid response length\")\r\n        if self._calculate_crc(response[:-2]) != response[-2:]:\r\n            raise ValueError(\"Invalid CRC\")\r\n        return response\r\n\r\n    #------------------------------#\r\n    #   BASIC PARAMETERS SETTING   #\r\n    #------------------------------#\r\n    \r\n    # Start the pump\r\n    def start_pump(self):\r\n        print(\"Starting pump...\")\r\n        response = self._send_command(0x06, 0x03F0, 0x0001, 'int')\r\n        print(f\"Start pump response: {response.hex()}\")\r\n        \r\n    # Stop the pump\r\n    def stop_pump(self):\r\n        print(\"Stopping pump...\")\r\n        response = self._send_command(0x06, 0x03F0, 0x0000, 'int')\r\n        print(f\"Stop pump response: {response.hex()}\")\r\n        \r\n    # Set the pump head\r\n    def set_pump_head(self, pump_head):\r\n        print(f\"Setting pump head to {pump_head}...\")\r\n        response = self._send_command(0x06, 0x03E8, pump_head, 'int')\r\n        print(f\"Set pump head response: {response.hex()}\")\r\n        \r\n    # Set the tube size\r\n    def set_tube_size(self, tube_size):\r\n        print(f\"Setting tube size to {tube_size}...\")\r\n        response = self._send_command(0x06, 0x03E9, tube_size, 'int')\r\n        print(f\"Set tube size response: {response.hex()}\")\r\n        \r\n    # Set the direction of rotation\r\n    def set_direction(self, direction):\r\n        print(f\"Setting direction to {direction}...\")\r\n        data = 0x0001 if direction.upper() == \"CW\" else 0x0000\r\n        response = self._send_command(0x06, 0x03F1, data, 'int')\r\n        print(f\"Set direction response: {response.hex()}\")\r\n        \r\n    # Set the speed of the pump in RPM\r\n    def set_speed(self, speed):\r\n        print(f\"Setting speed to {speed} RPM...\")\r\n        response = self._send_command(0x10, 0x03EA, speed, 'float')\r\n        print(f\"Set speed response: {response.hex()}\")\r\n\r\n    # Set the flow rate in mL/min\r\n    def set_flow_rate(self, flow_rate):\r\n        print(f\"Setting flow rate to {flow_rate} mL/min...\")\r\n        response = self._send_command(0x10, 0x03EC, flow_rate, 'float')\r\n        print(f\"Set flow rate response: {response.hex()}\")\r\n        \r\n    # Set the flow volume in mL\r\n    def set_flow_volume(self, volume):\r\n        print(f\"Setting flow volume to {volume} mL...\")\r\n        response = self._send_command(0x10, 0x03F3, volume, 'float')\r\n        print(f\"Set flow volume response: {response.hex()}\")\r\n\r\n    # Set the working time in seconds\r\n    def set_working_time(self, time):\r\n        print(f\"Setting working time to {time} seconds...\")\r\n        response = self._send_command(0x10, 0x03FA, time, 'float')\r\n        print(f\"Set working time response: {response.hex()}\")\r\n\r\n    # Set the working mode\r\n    def set_working_mode(self, mode):\r\n        \"\"\"\r\n        Working modes:\r\n        0: Transferring\r\n        1: Fixed volume measurement\r\n        2: Fixed time and volume\r\n        \"\"\"\r\n        if mode not in [0, 1, 2]:\r\n            raise ValueError(\"Invalid working mode. Must be 0, 1, or 2.\")\r\n        \r\n        print(f\"Setting working mode to {mode}...\")\r\n        response = self._send_command(0x06, 0x03FC, mode, 'int')\r\n        print(f\"Set working mode response: {response.hex()}\")\r\n        \r\n    # Set the pause time in seconds\r\n    def set_pause_time(self, time):\r\n        print(f\"Setting pause time to {time} seconds...\")\r\n        response = self._send_command(0x10, 0x03FD, time, 'float')\r\n        print(f\"Set pause time response: {response.hex()}\")\r\n\r\n    # Set the number of copies\r\n    def set_copy_numbers(self, numbers):\r\n        print(f\"Setting copy numbers to {numbers}...\")\r\n        response = self._send_command(0x06, 0x03FF, numbers, 'int')\r\n        print(f\"Set copy numbers response: {response.hex()}\")\r\n\r\n    # Set the back suction angle in degrees\r\n    def set_back_suction_angle(self, angle):\r\n        print(f\"Setting back suction angle to {angle} degrees...\")\r\n        response = self._send_command(0x06, 0x03EF, angle, 'int')\r\n        print(f\"Set back suction angle response: {response.hex()}\")\r\n\r\n    # Start or stop full speed running\r\n    def set_full_speed_running(self, start):\r\n        state = \"Start\" if start else \"Stop\"\r\n        print(f\"{state} full speed running...\")\r\n        data = 0x0001 if start else 0x0000\r\n        response = self._send_command(0x06, 0x03F2, data, 'int')\r\n        print(f\"{state} full speed running response: {response.hex()}\")\r\n        \r\n    #---------------------------------------#\r\n    #   CALIBRATION PARAMETERS SETTING UP   #\r\n    #---------------------------------------#\r\n    \r\n    # Set the testing time in seconds\r\n    def set_testing_time(self, time):\r\n        print(f\"Setting testing time to {time} seconds...\")\r\n        response = self._send_command(0x06, 0x07D1, time, 'int')\r\n        print(f\"Set testing time response: {response.hex()}\")\r\n        \r\n    # Start the calibration test\r\n    def start_test(self):\r\n        print(\"Starting test...\")\r\n        response = self._send_command(0x06, 0x07D2, 0x0001, 'int')\r\n        print(f\"Start test response: {response.hex()}\")\r\n        \r\n    # Stop the calibration test\r\n    def stop_test(self):\r\n        print(\"Stopping test...\")\r\n        response = self._send_command(0x06, 0x07D2, 0x0000, 'int')\r\n        print(f\"Stop test response: {response.hex()}\")\r\n        \r\n    # Set the actual volume in mL\r\n    def set_actual_volume(self, volume):\r\n        print(f\"Setting actual volume to {volume} mL...\")\r\n        response = self._send_command(0x10, 0x07D3, volume, 'float')\r\n        print(f\"Set actual volume response: {response.hex()}\")\r\n        \r\n    # Restore calibration defaults\r\n    def restore_defaults(self):\r\n        print(\"Restoring defaults...\")\r\n        response = self._send_command(0x06, 0x07D5, 0x0001, 'int')\r\n        print(f\"Restore defaults response: {response.hex()}\")\r\n        \r\n    # Perform micro adjustment (increase or decrease)\r\n    def micro_adjustment(self, increase=True):\r\n        action = \"Increase\" if increase else \"Decrease\"\r\n        print(f\"{action} micro adjustment...\")\r\n        data = 0x0001 if increase else 0x0000\r\n        response = self._send_command(0x06, 0x07D6, data, 'int')\r\n        print(f\"{action} micro adjustment response: {response.hex()}\")\r\n        \r\n#-----------------------------------------------------------------------#\r\n#   EXAMPLES ON HOW TO USE THE DEFINED CLASS TO CONTROL THE LABV PUMP   #\r\n#-----------------------------------------------------------------------#\r\n\r\nif __name__ == \"__main__\":\r\n    pump = LABV(port='COM6', address=1)  # Change port and address according to your setup\r\n    pump.connect()\r\n\r\n    try:\r\n        pump.set_pump_head(5)\r\n        pump.set_tube_size(16)\r\n        pump.set_direction(\"CW\")\r\n        pump.set_speed(50)\r\n        pump.set_flow_rate(50.0)\r\n        pump.set_back_suction_angle(0)\r\n        pump.set_full_speed_running(True)\r\n        pump.start_pump()\r\n\r\n    except Exception as e:\r\n        print(f\"An error occurred: {e}\")\r\n    finally:\r\n        pump.stop_pump()\r\n        pump.disconnect()\r\n</xmp>\n\t\t\t\t</code>\n\t\t\t</pre>\n\t\t</div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2e0bca4 elementor-widget elementor-widget-text-editor\" data-id=\"2e0bca4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Deze Python-bibliotheek voor de contrôle externe van de LabV pompserie via het MODBUS RTU-protocol zorgt voor een nauwkeurige en geautomatiseerde aansturing van verschillende pompparameters zoals snelheid, richting, pompkop en slangmaat. Gebruikers van een LabV pomp kunnen hun pomp nu eenvoudig integreren in complexe workflows met meerdere apparaten, wat de operationele efficiëntie en flexibiliteit vergroot.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-679f305 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"679f305\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-71d5293\" data-id=\"71d5293\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-336c844 elementor-widget elementor-widget-heading\" data-id=\"336c844\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusie</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c5dacb0 elementor-widget elementor-widget-text-editor\" data-id=\"c5dacb0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In deze blogpost hebben we de LabV peristaltische pompserie geïntroduceerd en de grondbeginselen verkend van de contrôle externe via Python met behulp van het MODBUS RTU-communicatieprotocol. We hopen dat dit artikel dient als een waardevolle gids voor onderzoekers en ingenieurs die een LabV peristaltische pomp willen inzetten in hun microfluïdica-onderzoek en -experimenten.</p><p><strong><em>🚨 </em></strong><em>Hoewel er variaties bestaan tussen de verschillende series van Innofluid Lab pompen, benadrukken we dat het communicatieprotocol nagenoeg ongewijzigd blijft. Of u nu de LabF-serie, LabN-serie of een andere gebruikt, we vertrouwen erop dat deze inhoud eveneens nuttig zal zijn voor uw toekomstige projecten.</em></p><p>Blijf op de hoogte voor meer inzichten, tutorials en praktijktoepassingen in onze toekomstige berichten. Veel succes met pompen en programmeren 💻!</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-17b2b7c elementor-widget elementor-widget-text-editor\" data-id=\"17b2b7c\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>📧 Als u vragen of opmerkingen heeft, neem dan gerust contact met ons op via <a href=\"https://darwin-microfluidics.com/nl/pages/contact\"><span style=\"font-weight: 400;\">support@darwin-microfluidics.com</span></a><span style=\"font-weight: 400;\">.</span></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-97f1388 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"97f1388\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Hulp nodig bij uw microfluïdica-project?\"><a href=\"https://darwin-microfluidics.com/nl/contact\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Neem contact op met onze experts!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Hulp nodig bij uw microfluïdica-project?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Wij maken microfluïdica voor u heel eenvoudig!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>The LabV pump series from Innofluid (formerly known as Shenchen Baoding) is an advanced series of flow measurement peristaltic pumps featuring a 4.3-inch color touch screen for intuitive control. It displays flow data, settings, and system information simultaneously, with animations…</p>\n","protected":false},"author":4,"featured_media":23931,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[24,33],"tags":[],"class_list":["post-23929","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-control","category-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Hoe bestuurt u een LabV-pomp met behulp van het MODBUS-protocol ? - Darwin Microfluidics</title>\n<meta name=\"description\" content=\"Leer hoe u LabV-pompen aanstuurt met behulp van het MODBUS RTU-protocol met onze handleiding. Vereenvoudig uw pompcontrôle externe effectief.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Hoe bestuurt u een LabV-pomp met behulp van het MODBUS-protocol ? - Darwin Microfluidics\">\n<meta property=\"og:description\" content=\"Leer hoe u LabV-pompen aanstuurt met behulp van het MODBUS RTU-protocol met onze handleiding. Vereenvoudig uw pompcontrôle externe effectief.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-06-10T12:50:28+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:25:03+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg\">\n\t<meta property=\"og:image:width\" content=\"640\">\n\t<meta property=\"og:image:height\" content=\"640\">\n\t<meta property=\"og:image:type\" content=\"image/jpeg\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"13 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"How to Control a LabV Pump Using the MODBUS Protocol ?\",\"datePublished\":\"2024-06-10T12:50:28+00:00\",\"dateModified\":\"2026-11-19T14:25:03+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\"},\"wordCount\":2410,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg\",\"articleSection\":[\"Flow control\",\"Guides &amp; tutorials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\",\"url\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\",\"name\":\"How to Control a LabV Pump Using the MODBUS Protocol ? - Darwin Microfluidics\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg\",\"datePublished\":\"2024-06-10T12:50:28+00:00\",\"dateModified\":\"2026-11-19T14:25:03+00:00\",\"description\":\"Leer hoe u LabV-pompen aanstuurt met behulp van het MODBUS RTU-protocol met onze handleiding. Vereenvoudig uw pompcontrôle externe effectief.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg\",\"width\":640,\"height\":640,\"caption\":\"An image of the LabV-III Intelligent Flow Rate Peristaltic Pump with a white background.\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Control a LabV Pump Using the MODBUS Protocol ?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Onze blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/nl\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Control a LabV Pump Using the MODBUS Protocol ? - Darwin Microfluidics","description":"Leer hoe u LabV-pompen aanstuurt met behulp van het MODBUS RTU-protocol met onze handleiding. Vereenvoudig uw pompcontrôle externe effectief.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/","og_locale":"en_US","og_type":"article","og_title":"How to Control a LabV Pump Using the MODBUS Protocol ? - Darwin Microfluidics","og_description":"Learn how to control LabV pumps using the MODBUS RTU protocol with our user guide. Simplify your pump control processes effectively.","og_url":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-06-10T12:50:28+00:00","article_modified_time":"2026-11-19T14:25:03+00:00","og_image":[{"width":640,"height":640,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","type":"image/jpeg"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"13 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"How to Control a LabV Pump Using the MODBUS Protocol ?","datePublished":"2024-06-10T12:50:28+00:00","dateModified":"2026-11-19T14:25:03+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/"},"wordCount":2410,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","articleSection":["Flow control","Guides &amp; tutorials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/","url":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/","name":"How to Control a LabV Pump Using the MODBUS Protocol ? - Darwin Microfluidics","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","datePublished":"2024-06-10T12:50:28+00:00","dateModified":"2026-11-19T14:25:03+00:00","description":"Leer hoe u LabV-pompen aanstuurt met behulp van het MODBUS RTU-protocol met onze handleiding. Vereenvoudig uw pompcontrôle externe effectief.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","width":640,"height":640,"caption":"An image of the LabV-III Intelligent Flow Rate Peristaltic Pump with a white background."},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/how-to-control-a-labv-pump-using-the-modbus-protocol/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"How to Control a LabV Pump Using the MODBUS Protocol ?"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Onze blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/05/LabV1-III.jpg","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/23929","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=23929"}],"version-history":[{"count":332,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/23929/revisions"}],"predecessor-version":[{"id":33685,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/23929/revisions/33685"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/23931"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=23929"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=23929"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=23929"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}