{"id":29503,"date":"2024-10-23T17:58:13","date_gmt":"2024-10-23T15:58:13","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=29503"},"modified":"2026-11-19T15:27:10","modified_gmt":"2026-11-19T14:27:10","slug":"how-to-control-longer-pumps-using-the-modbus-rtu-protocol","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/","title":{"rendered":"How to Control Longer Pumps Using the Modbus RTU Protocol?"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"29503\" class=\"elementor elementor-29503\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-94c0380 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"94c0380\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-d77f898\" data-id=\"d77f898\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-840748b elementor-widget elementor-widget-text-editor\" data-id=\"840748b\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><a href=\"https://darwin-microfluidics.com/nl/categorieen/peristaltische-pompen/\"><strong>Peristaltische pompen</strong></a> spelen een cruciale rol in microfluïdica-onderzoek en medische diagnostiek en bieden nauwkeurige vloeistofbeheersing met een minimaal risico op contaminatie. Van de vele beschikbare opties hebben <a href=\"https://darwin-microfluidics.com/nl/longer/\"><strong>Longer-pompen</strong></a>, geproduceerd door Longer Precision Pump Co., Ltd., een reputatie opgebouwd vanwege hun betrouwbaarheid, precisie en veelzijdigheid.</p><p>Een van de opvallende kenmerken van de peristaltische Longer-pompen is de mogelijkheid om ze <strong>op afstand te besturen</strong> vanaf een computer, waardoor gebruikers complexe pompprogramma's met lussen, pauzes en variërende debieten met grotere flexibiliteit en gemak kunnen uitvoeren.</p><p>In dit blogartikel duiken we in het aansturen van peristaltische Longer-pompen met behulp van het <strong>Modbus RTU-protocol</strong>, een veel gebruikt seriële communicatieprotocol waarmee commando's naar de pomp kunnen worden verzonden en reacties kunnen worden ontvangen. Hoewel de details van het Modbus-protocol enigszins kunnen verschillen per pompmodel, gebruiken we in dit artikel de <a href=\"https://darwin-microfluidics.com/nl/producten/l100-1s-2-precision-peristaltic-pump\">Longer L100-1S-2 peristaltische pomp</a> als referentiemodel. We loodsen u tevens door Python-voorbeelden en <a href=\"#code\">codesnippets</a> heen, die u direct kunt kopiëren en gebruiken in uw eigen scripts om uw pomp eenvoudig aan te sturen.</p><p><em>🚨 U kunt dezelfde concepten en codevoorbeelden toepassen op andere Longer-pompen, waarbij u bepaalde commando's aanpast op basis van het specifieke protocol van uw pompmodel.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e48216b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e48216b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-46feb6a\" data-id=\"46feb6a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-17e92bc elementor-widget elementor-widget-heading\" data-id=\"17e92bc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Wat heeft u nodig om te communiceren met uw Longer-pomp?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6de9eb5 elementor-widget elementor-widget-text-editor\" data-id=\"6de9eb5\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Om te communiceren met een peristaltische Longer-pomp via het Modbus RTU-protocol, heeft u het volgende nodig:</p><ul><li>Een Longer-pomp met een <a href=\"https://darwin-microfluidics.com/nl/collections/pompkoppen-voor-peristaltische-pompen\">pompkop</a> en <a href=\"https://darwin-microfluidics.com/nl/collections/slangen-voor-peristaltische-pompen\">tube</a> naar keuze</li><li>Een RS485 <a href=\"https://darwin-microfluidics.com/nl/collections/accessoires-voor-peristaltische-pompen/producten/external-control-module-for-longer-pumps\">besturingsmodule</a> die in de DB15-poort aan de achterzijde van de pomp wordt geplugd</li><li>Een <a href=\"https://darwin-microfluidics.com/nl/producten/usb-to-rs485-serial-converter-cable/\">seriële kabel</a> die de RS485-besturingsmodule verbindt met uw computer of apparaat</li><li>Een programmeerplatform (in dit geval Python)</li><li>Een basisbegrip van het Modbus RTU-protocol (hieronder uitgelegd <a href=\"#modbus\">👇</a>).</li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-e6c864e elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"e6c864e\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-4eee8bd\" data-id=\"4eee8bd\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-a9e4540 elementor-widget elementor-widget-heading\" data-id=\"a9e4540\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hoe configureert u de communicatiepoort?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2c19c99 elementor-widget elementor-widget-text-editor\" data-id=\"2c19c99\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Voordat u data kunt verzenden en ontvangen van de pomp, moet u de communicatiepoort correct instellen. Volg hiervoor de volgende stappen:</p><ul><li>Sluit de DB15-connector aan op de DB15-poort aan de achterzijde van de pomp</li><li>Schakel de pomp in en gebruik het toetsenbord aan de voorzijde van de pomp om naar de instellingsinterface voor afstandsbediening te gaan en de afstandsbedieningsmodus in te stellen op &quot;COM&quot; 🕹️</li><li>Zorg ervoor dat de communicatieparameters op uw programmeerplatform overeenkomen met die van de L100-1S-2 (zoals te zien is in onderstaande figuur), te weten:<ul><li>1 startbit</li><li>8 databits</li><li><strong>Pariteit</strong>: P-n (geen pariteit), P-O (oneven pariteit) of P-E (even pariteit)</li><li><strong>Stopbit</strong>: S-1 (1 stopbit) of S-2 (2 stopbits)</li><li><strong>Baudrate</strong>: 12 (1200 bit/s), 24 (2400 bit/s), 48 (4800 bit/s), 96 (9600 bit/s), 192 (19200 bit/s) of 384 (38400 bit/s).</li></ul></li></ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8e055d7 elementor-widget elementor-widget-text-editor\" data-id=\"8e055d7\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>🚨 De communicatie is <strong>alleen</strong> geldig wanneer de pomp het werkscherm van de communicatieregelmodus \"<strong>COM</strong>\" weergeeft.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c9b7349 elementor-widget elementor-widget-image\" data-id=\"c9b7349\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"image.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t\t\t\t<figure class=\"wp-caption\">\n\t\t\t\t\t\t\t\t\t\t<img fetchpriority=\"high\" decoding=\"async\" width=\"640\" height=\"488\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/parameter_setting.jpg\" class=\"attachment-large size-large wp-image-19400\" alt=\"\" srcset=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/parameter_setting.jpg 928w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/parameter_setting-300x229.jpg 300w, https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/parameter_setting-768x585.jpg 768w\" sizes=\"(max-width: 640px) 100vw, 640px\">\t\t\t\t\t\t\t\t\t\t\t<figcaption class=\"widget-image-caption wp-caption-text\">Procedure voor het instellen van parameters (Afbeelding uit de L100-1S-2 handleiding van Longer Precision Pump Co., Ltd.).</figcaption>\n\t\t\t\t\t\t\t\t\t\t</figure>\n\t\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ce931e2 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ce931e2\" data-element_type=\"section\" data-e-type=\"section\" id=\"modbus\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-157e85a\" data-id=\"157e85a\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-aea4e15 elementor-widget elementor-widget-heading\" data-id=\"aea4e15\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Het Modbus RTU-protocol begrijpen</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80dfa1d elementor-widget elementor-widget-text-editor\" data-id=\"80dfa1d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Het <a href=\"https://www.modbustools.com/modbus.html\" target=\"_blank\" rel=\"noopener\">Modbus RTU-protocol</a> is een algemeen aanvaarde communicatiestandaard die wordt gebruikt in industriële systemen en automatiseringssystemen om gegevens uit te wisselen tussen apparaten. Dankzij de eenvoud en robuustheid is het ideaal voor het aansturen van apparatuur zoals Longer peristaltische pompen. In dit gedeelte gaan we dieper in op de belangrijkste elementen van Modbus RTU, waaronder het communicatieformaat, de Cyclic Redundancy Check (CRC) en de communicatie-instellingen. Ook onderzoeken we de structuur van Modbus RTU-berichten en de opdrachtset die wordt gebruikt om Longer pompen effectief aan te sturen.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-3dc3ab9 elementor-widget elementor-widget-heading\" data-id=\"3dc3ab9\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Modbus RTU Standaard Communicatieformaat</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b6f9217 elementor-widget elementor-widget-text-editor\" data-id=\"b6f9217\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Het Modbus-protocol is een veelgebruikt communicatieraamwerk dat master-slave-interacties tussen intelligente apparaten mogelijk maakt. Een Modbus-bericht dat van een master naar een slave wordt verzonden, omvat het adres van de slave, een specifiek commando (zoals het lezen van of schrijven naar een register), de bijbehorende gegevens en een checksum voor foutcontrole.</p><p>Dit berichtformaat wordt beschreven in de onderstaande tabel.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-d45eea8 elementor-widget elementor-widget-shortcode\" data-id=\"d45eea8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-77\" class=\"tablepress tablepress-id-77\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Veld</th><th class=\"column-2\">Maat</th><th class=\"column-3\">Beschrijving</th>\n</tr>\n</thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Slave-adres</td><td class=\"column-2\">1 byte</td><td class=\"column-3\">Adres van de pomp. Het bereik is 1-32; 0 wordt gebruikt voor broadcast-communicatie.</td>\n</tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Functiecode</td><td class=\"column-2\">1 byte</td><td class=\"column-3\">Instructie voor het slave-apparaat:<br>\n- <strong>03H:</strong> Holding registers lezen<br>\n- <strong>06H:</strong> Enkel register schrijven<br>\n- <strong>10H:</strong> Meerdere registers schrijven</td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Datagebied</td><td class=\"column-2\">0 – 252 bytes</td><td class=\"column-3\">Te verzenden data (variabele lengte)</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">CRC-controle</td><td class=\"column-2\">2 bytes</td><td class=\"column-3\">Cyclic Redundancy Check voor foutdetectie:<br>\n- CRC laag (1 Byte): Lagere byte van de CRC<br>\n- CRC hoog (1 Byte): Hogere byte van de CRC</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-77 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-8dd4ad2 elementor-widget elementor-widget-heading\" data-id=\"8dd4ad2\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">CRC-controle met CRC-16 in Python</h4>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-cb6dc85 elementor-widget elementor-widget-text-editor\" data-id=\"cb6dc85\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>CRC (Cyclic Redundancy Check) is een essentiële techniek voor het detecteren van fouten in datatransmissie. Hieronder demonstreren we hoe u CRC-16, zoals gebruikt in het Amerikaanse binaire synchrone systeem, kunt implementeren in Python.\n\nBij CRC-16 maakt het foutdetectie-algoritme gebruik van een polynoom <span style=\"background-color: lightgray;\">G(X) = X<sup>16</sup> + X<sup>15</sup> + X<sup>2</sup> + 1</span> om de checksum te genereren. Dit polynoom definieert de wiskundige bewerkingen die worden uitgevoerd op de bits van het bericht tijdens het berekeningsproces van de CRC. Hieronder volgt een overzicht van het algoritme:\n</p><ul>\n \t<li>Initialiseer een 16-bits register met de hexadecimale waarde FFFF (allemaal enen), aangeduid als het CRC-register.</li>\n \t<li>Voer een XOR-bewerking uit op de eerste 8 bytes van het bericht met de lage byte van het CRC-register. Sla het resultaat op in het CRC-register.</li>\n \t<li>Schuif het CRC-register één bit naar rechts, waarbij de meest significante bit (MSB) op nul wordt gezet.</li>\n \t<li>Controleer de minst significante bit (LSB) van het CRC-register:\n<ul>\n \t<li>Als de LSB 0 is, herhaal stap 3 (schuifoperatie).</li>\n \t<li>Als de LSB 1 is, voer dan een XOR-bewerking uit op het CRC-register met de polynoomwaarde 0xA001 (1010 0000 0000 0001).</li>\n</ul>\n</li>\n \t<li>Herhaal stap 3-4, in totaal 8 verschuivingen, om elke byte te verwerken.</li>\n \t<li>Herhaal stap 2-5 voor elke byte in het bericht totdat alle bytes zijn verwerkt.</li>\n \t<li>De uiteindelijke inhoud van het CRC-register is de CRC-waarde.</li>\n</ul>\n🚨 <em>In het bericht moeten de hoge en lage bytes van de CRC-waarden worden omgewisseld.</em>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-baa24b4 elementor-widget elementor-widget-heading\" data-id=\"baa24b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Communicatie-instellingen</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2986dcc elementor-widget elementor-widget-text-editor\" data-id=\"2986dcc\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Elke byte aan gegevens heeft een structuur bestaande uit 1 startbit, 8 databits, 1 pariteitsbit en 1 of 2 stopbit(s). Bits worden verzonden in volgorde van de minst significante bit (LSB) naar de meest significante bit (MSB).</p><p>Voor integers (2 bytes) worden de gegevens zo gerangschikt dat de tweede byte eerst komt, gevolgd door de eerste byte. De hexadecimale waarde 2378H wordt bijvoorbeeld verzonden als 23H 78H. Voor long integers en floats (4 bytes) worden de gegevens gerangschikt met de vierde byte als eerste, gevolgd door de derde, tweede en eerste byte.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f8f6b8a elementor-widget elementor-widget-heading\" data-id=\"f8f6b8a\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Modbus RTU-berichtframeformaat</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-80c0f65 elementor-widget elementor-widget-text-editor\" data-id=\"80c0f65\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>De Modbus RTU-berichtframerate is zoals beschreven in onderstaande tabel.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-c3840de elementor-widget elementor-widget-shortcode\" data-id=\"c3840de\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-78\" class=\"tablepress tablepress-id-78\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Veld</th><th class=\"column-2\">Maat</th><th class=\"column-3\">Beschrijving</th>\n</tr>\n</thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Start</td><td class=\"column-2\">≥ 3,5 tekens</td><td class=\"column-3\">Geeft het begin van de transmissie aan.</td>\n</tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Adres</td><td class=\"column-2\">8 Bits</td><td class=\"column-3\">Adres van het slave-apparaat.</td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Functiecode</td><td class=\"column-2\">8 Bits</td><td class=\"column-3\">Instructie voor het slave-apparaat.</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Data</td><td class=\"column-2\">N x 8 bits</td><td class=\"column-3\">Over te dragen gegevens (variabele lengte, N bytes).</td>\n</tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">CRC-controlecode</td><td class=\"column-2\">16 bits</td><td class=\"column-3\">Cyclic Redundancy Check voor foutdetectie.</td>\n</tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Einde</td><td class=\"column-2\">≥ 3,5 tekens</td><td class=\"column-3\">Geeft het einde van de transmissie aan.</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-78 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b6d904e elementor-widget elementor-widget-text-editor\" data-id=\"b6d904e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><em>🚨 Zorg ervoor dat het berichtframe continu wordt verzonden zonder inactieve tussenpozen tussen karakters die groter zijn dan 1,5 karaktertijd. Onvolledige berichtframes, aangegeven door een te lange inactieve tussenpoze, moeten door het ontvangende knooppunt worden genegeerd.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-24af7fb elementor-widget elementor-widget-heading\" data-id=\"24af7fb\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h3 class=\"elementor-heading-title elementor-size-default\">Parameterinstelling</h3>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-b6f5264 elementor-widget elementor-widget-text-editor\" data-id=\"b6f5264\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In onderstaande tabel worden de essentiële <a href=\"#parameter\">parameterinstellingen</a> voor het L100-1S-2-model uiteengezet. Deze parameters kunnen per Longer-pompmodel verschillen, hetzij door de specifieke beschikbare functies, hetzij door het unieke adres en de beschrijvingen die aan elke parameter zijn gekoppeld.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-172d3a5 elementor-widget elementor-widget-shortcode\" data-id=\"172d3a5\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"parameter\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-76\" class=\"tablepress tablepress-id-76 tbody-has-connected-cells\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Parameter</th><th class=\"column-2\">Adres</th><th class=\"column-3\">Gegevenstype</th><th class=\"column-4\">Beschrijving</th>\n</tr>\n</thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Snelheid</td><td class=\"column-2\">0x01</td><td class=\"column-3\">uint_16</td><td class=\"column-4\">Bereik: 1-10.000, overeenkomend met 0,01 rpm tot 100 rpm, in stappen van 0,01 rpm. De pomp toont de snelheid in rpm. Voorbeeld: 100 = 0,01 rpm, 10000 = 100 rpm.</td>\n</tr>\n<tr class=\"row-3\">\n\t<td rowspan=\"2\" class=\"column-1\">debiet</td><td class=\"column-2\">0x02</td><td class=\"column-3\">uint_16</td><td class=\"column-4\">De hoge bytes van het debiet. Wordt gebruikt in combinatie met de lage byte van het debiet. De eenheid van het debiet is 1 nL/min. Voorbeeld: 02 FA F0 80H = 50,0 mL/min.</td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-2\">0x03</td><td class=\"column-3\">uint_16</td><td class=\"column-4\">De lage bytes van het debiet. Wordt gebruikt in combinatie met de hoge byte van het debiet. De eenheid van het debiet is 1 nL/min. Voorbeeld: 02 FA F0 80H = 50,0 mL/min.</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Pomptoestand</td><td class=\"column-2\">0x04</td><td class=\"column-3\">uint_16</td><td class=\"column-4\">Lage byte is geldig. <br>\nBIT0: Run/Stop (0 = stop, 1 = run). <br>\nBIT1: Volle snelheid (0 = normale snelheid, 1 = volle snelheid). <br>\nBIT2: Weergave snelheid/debiet. <br>\nBIT3: Gereserveerd.<br>\nBIT4: Richting (0 = CW, 1 = CCW)</td>\n</tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Pompadres</td><td class=\"column-2\">0x05</td><td class=\"column-3\">uint_16</td><td class=\"column-4\">Lage byte is geldig. Geldig bereik: 1-32</td>\n</tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Baudrate</td><td class=\"column-2\">0x06</td><td class=\"column-3\">uint_16</td><td class=\"column-4\">Lage byte is geldig.<br>\n01H: 1200 bps<br>\n02H: 2400 bps<br>\n03H: 4800 bps<br>\n04H: 9600 bps<br>\n05H: 19200 bps<br>\n06H: 38400 bps<br>\n</td>\n</tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Pariteit</td><td class=\"column-2\">0x07</td><td class=\"column-3\">uint_16</td><td class=\"column-4\">Lage byte is geldig.<br>\n01H: Geen pariteit<br>\n02H: Oneven pariteit<br>\n03H: Even pariteit</td>\n</tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Stopbit</td><td class=\"column-2\">0x08</td><td class=\"column-3\">uint_16</td><td class=\"column-4\">Lage byte is geldig.<br>\n01H: 1 stopbit<br>\n02H: 2 stopbits</td>\n</tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Toetsenbordvergrendeling</td><td class=\"column-2\">0x09</td><td class=\"column-3\">uint_16</td><td class=\"column-4\">Lage byte: Schakelt de vergrendelingsfunctie van het toetsenbord in.<br>\n01H: Uitgeschakeld<br>\n02H: Ingeschakeld<br>\nHoge byte: Vertraging vóór vergrendeling.<br>\n00H: 30s<br>\n01H: 60s<br>\n02H: 180s<br>\n03H: 300s<br>\n04H: 480s<br>\n05H: 600s</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-76 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-595a976 elementor-widget elementor-widget-text-editor\" data-id=\"595a976\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>💡 Belangrijke opmerkingen:</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5036b78 elementor-widget elementor-widget-text-editor\" data-id=\"5036b78\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>Het Longer Modbus RTU-protocol ondersteunt uitsluitend functiecodes 03H (registers lezen), 06H (enkel register schrijven) en 10H (meerdere registers schrijven).</li>\n \t<li>Bij gebruik van functiecode 06H werkt de pomp op basis van het laatst ontvangen commando, waarbij de snelheid wordt weergegeven via een snelheidsparameter en het debiet via een debietparameter.</li>\n \t<li>Om het debiet in te stellen, moeten zowel de hoge byte als de lage byte tegelijkertijd worden opgegeven. De eenheid voor het debiet is 1 nL/min (het commando 02 FA F0 80H komt bijvoorbeeld overeen met 50,0 mL/min).</li>\n \t<li>Indien het debiet of het toerental het toegestane bereik overschrijdt, toont de pomp de maximum- of minimumwaarde zonder een waarschuwing te geven.</li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-6e015ee elementor-widget elementor-widget-heading\" data-id=\"6e015ee\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h4 class=\"elementor-heading-title elementor-size-default\">Omrekeningsrelatie tussen debiet en toerental</h4>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-799ca28 elementor-widget elementor-widget-text-editor\" data-id=\"799ca28\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Het verband tussen het debiet en het toerental voor de L100-1S-2 kan worden beschreven met de vergelijking: <strong>Q = V x f</strong></p><p>Waar <strong>Q</strong> het debiet in mL/min vertegenwoordigt, <strong>V</strong> staat voor het toerental in rpm, en <strong>f</strong> is de debietcoëfficiënt gemeten in mL/r, die standaard is ingesteld op <strong><span style=\"color: red;\">1</span></strong>.</p><p>De standaardwaarde <strong><span style=\"color: red;\">f = 1</span></strong> wijst op een directe correlatie tussen het toerental en het debiet onder standaardomstandigheden. Deze eenvoud maakt het voor operators erg overzichtelijk om de pompinstellingen te optimaliseren voor hun specifieke toepassingen.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-4dbdbf3 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"4dbdbf3\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a8d568c\" data-id=\"a8d568c\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-c639bc4 elementor-widget elementor-widget-heading\" data-id=\"c639bc4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Hoe communiceer je met de L100-1S-2 via Python?</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a9d284e elementor-widget elementor-widget-text-editor\" data-id=\"a9d284e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In deze sectie wordt een <a href=\"#code\">eenvoudige Python-bibliotheek</a> gepresenteerd die is ontworpen om communicatie met en aansturing van Longer peristaltische pompen via het Modbus RTU-protocol mogelijk te maken. Deze bibliotheek omvat essentiële functionaliteiten, zoals het instellen van het pomptoerental, het debiet en de draairichting, evenals het moeiteloos starten en stoppen van de pomp.</p><p>Deze bibliotheek is specifiek geschreven op basis van het protocol van de Longer L100-1S-2 peristaltische pomp en dient als een voorbeeld dat naar wens kan worden aangepast. Door de commando's en parameters naar behoefte aan te passen, kunnen gebruikers de code afstemmen op het Modbus RTU-protocol van hun specifieke Longer pompmodel.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-4b7686d elementor-widget elementor-widget-text-editor\" data-id=\"4b7686d\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>🚨🚨🚨 Belangrijke opmerking</strong></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-f8eefba elementor-widget elementor-widget-text-editor\" data-id=\"f8eefba\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<ul>\n \t<li>When viewing this code, please be aware that <strong><span style=\"color: red;\">&lt;</span></strong>, <strong><span style=\"color: red;\">&gt;</span></strong>, and <strong><span style=\"color: red;\">&amp;</span></strong> symbols might not display correctly due to formatting issues. These should appear as standard Python code syntax, so make sure to interpret <strong><span style=\"color: red;\">&amp;lt;</span></strong> as <strong><span style=\"color: red;\">&lt;</span></strong>,<strong> <span style=\"color: red;\">&amp;gt;</span></strong> as <strong><span style=\"color: red;\">&gt;</span></strong>, and <strong><span style=\"color: red;\">&amp;amp;</span></strong> as <strong><span style=\"color: red;\">&amp;</span></strong>.</li>\n</ul>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-44c0284 elementor-widget elementor-widget-code-highlight\" data-id=\"44c0284\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"code\" data-widget_type=\"code-highlight.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"prismjs-tomorrow copy-to-clipboard word-wrap\">\n\t\t\t<pre data-line=\"\" class=\"highlight-height language-python line-numbers\">\n\t\t\t\t<code readonly=\"\" class=\"language-python\">\n\t\t\t\t\t<xmp>'''\r\n-------------------------------------------------------------\r\nLonger Peristaltic Pump Control Library Using Modbus Protocol \r\n-------------------------------------------------------------\r\n'''\r\n\r\nimport serial\r\nimport time\r\n\r\n#------------------------------------------------------#\r\n#   LIBRARY MANAGING THE COMMUNICATION WITH THE PUMP   #\r\n#------------------------------------------------------#\r\n\r\nclass Longer_Pump:\r\n    \r\n    # Initialize the class with serial communication parameters\r\n    def __init__(self, port, address=1, baudrate=9600, parity=serial.PARITY_NONE, bytesize=8, stopbits=1, timeout=1):\r\n        \"\"\"\r\n        Parameters:\r\n        port (str): The COM port for serial communication.\r\n        address (int): Modbus address of the pump (default is 1).\r\n        baudrate (int): The baud rate (default is 9600).\r\n        parity (str): Parity for serial communication (default is none).\r\n        bytesize (int): Number of data bits (default is 8).\r\n        stopbits (int): Number of stop bits (default is 1).\r\n        timeout (int): Timeout for serial communication (default is 1s).\r\n        \"\"\"\r\n        self.ser = serial.Serial(port=port, baudrate=baudrate, parity=parity, bytesize=bytesize, stopbits=stopbits, timeout=timeout)\r\n        self.address = address\r\n\r\n    # Open the serial port for communication with the pump\r\n    def connect(self):\r\n        if not self.ser.is_open:\r\n            self.ser.open()\r\n\r\n    # Close the serial port to end communication with the pump\r\n    def disconnect(self):\r\n        if self.ser.is_open:\r\n            self.ser.close()\r\n\r\n    # Calculate the CRC for Modbus communication\r\n    def _calculate_crc(self, data):\r\n        \"\"\"\r\n        Parameters:\r\n            data (bytearray): The data for which to calculate the CRC.\r\n        Returns:\r\n            bytes: The calculated CRC as a 2-byte value.\r\n        \"\"\"\r\n        crc = 0xFFFF\r\n        for byte in data:\r\n            crc ^= byte\r\n            for _ in range(8):\r\n                if crc &amp; 0x0001:\r\n                    crc &gt;&gt;= 1\r\n                    crc ^= 0xA001\r\n                else:\r\n                    crc &gt;&gt;= 1\r\n        return crc.to_bytes(2, byteorder='little')\r\n\r\n    # Send a command to the pump using the Modbus protocol\r\n    def _send_command(self, function_code, register_address, data):\r\n        \"\"\"\r\n        Parameters:\r\n            function_code (int): e.g., 0x03 for read, 0x06 for write.\r\n            register_address (int): to read from or write to.\r\n            data (list or int): to be sent (for writing registers).\r\n        Returns:\r\n            bytes: The response from the pump.\r\n        \"\"\"\r\n        \r\n        # Prepare the command payload for Modbus\r\n        payload = bytearray([self.address, function_code])\r\n        payload.extend(register_address.to_bytes(2, byteorder='big'))\r\n        \r\n        if isinstance(data, list):\r\n            # For multi-register commands (function code 0x10)\r\n            number_of_registers = len(data)\r\n            payload.extend(number_of_registers.to_bytes(2, byteorder='big'))\r\n            payload.append(len(data) * 2)  # Byte count for the data\r\n            for value in data:\r\n                payload.extend(value.to_bytes(2, byteorder='big'))\r\n        else:\r\n            # For single-register commands (function code 0x06)\r\n            payload.extend(data.to_bytes(2, byteorder='big'))\r\n\r\n        # Append CRC\r\n        crc = self._calculate_crc(payload)\r\n        payload.extend(crc)\r\n\r\n        # Send the command to the pump\r\n        self.ser.write(payload)\r\n        response = self.ser.read(8)  # Adjust this based on expected response length\r\n        return response\r\n\r\n    # Set the pump speed in RPM (0.01 RPM increments)\r\n    def set_speed(self, speed_rpm):\r\n        \"\"\"\r\n        Parameters:\r\n            speed_rpm (float): The desired speed in RPM.\r\n        \"\"\"\r\n        speed_value = int(speed_rpm * 100)  # 0.01 RPM increments\r\n        response = self._send_command(0x06, 0x01, speed_value)\r\n        print(f\"Set speed response: {response.hex()}\")\r\n\r\n    # Set the pump flow rate in mL/min (combined high/low bytes)\r\n    def set_flow_rate(self, flow_rate_ml_min):\r\n        \"\"\"\r\n        Parameters:\r\n            flow_rate_ml_min (float): The desired flow rate in mL/min.\r\n        \"\"\"\r\n        flow_rate_nl_min = int(flow_rate_ml_min * 1_000_000)  # Convert mL/min to nL/min\r\n        high_byte = (flow_rate_nl_min &gt;&gt; 16) &amp; 0xFFFF\r\n        low_byte = flow_rate_nl_min &amp; 0xFFFF\r\n        response = self._send_command(0x10, 0x02, [high_byte, low_byte])\r\n        print(f\"Set flow rate response: {response.hex()}\")\r\n\r\n    # Start the pump and set the display mode to either 'speed' (RPM) or 'flow_rate' (mL/min)\r\n    def start(self, display_mode=\"speed\"):\r\n        \"\"\"\r\n        Parameters:\r\n            display_mode (str): 'speed' or 'flow_rate'.\r\n        \"\"\"\r\n        if display_mode == \"speed\":\r\n            pump_state = 0b00000001  # Run + Display Speed\r\n        elif display_mode == \"flow_rate\":\r\n            pump_state = 0b00000101  # Run + Display Flow Rate\r\n        else:\r\n            raise ValueError(\"Invalid display_mode. Use 'speed' or 'flow_rate'.\")\r\n        response = self._send_command(0x06, 0x04, pump_state)\r\n        print(f\"Start pump response: {response.hex()}\")\r\n\r\n    # Stop the pump and set the display mode to either 'speed' (RPM) or 'flow_rate' (mL/min)\r\n    def stop(self, display_mode=\"speed\"):\r\n        \"\"\"\r\n        Parameters:\r\n            display_mode (str): 'speed' or 'flow_rate'.\r\n        \"\"\"\r\n        if display_mode == \"speed\":\r\n            pump_state = 0b00000000  # Stop + Display Speed\r\n        elif display_mode == \"flow_rate\":\r\n            pump_state = 0b00000100  # Stop + Display Flow Rate\r\n        else:\r\n            raise ValueError(\"Invalid display_mode. Use 'speed' or 'flow_rate'.\")\r\n        response = self._send_command(0x06, 0x04, pump_state)\r\n        print(f\"Stop pump response: {response.hex()}\")\r\n\r\n    # Set the pump direction (CW or CCW)\r\n    def set_direction(self, direction):\r\n        \"\"\"\r\n        Parameters:\r\n            direction (str): 'CW' for clockwise, 'CCW' for counter-clockwise.\r\n        \"\"\"\r\n        direction_value = 0x0010 if direction.upper() == 'CCW' else 0x0000\r\n        response = self._send_command(0x06, 0x04, direction_value)\r\n        print(f\"Set direction response: {response.hex()}\")\r\n\r\n    # Custom function: Run the pump at the specified speed for a certain amount of time and then stop\r\n    def run(self, speed_rpm, run_time_s, direction='CW'):\r\n        \"\"\"\r\n        Parameters:\r\n            speed_rpm (float): The speed at which to run the pump in RPM.\r\n            run_time_s (int): The time to run the pump in seconds.\r\n            direction (str): 'CW' or 'CCW'.\r\n        \"\"\"\r\n        try:\r\n            self.set_speed(speed_rpm)\r\n            self.set_direction(direction)\r\n            self.start(display_mode=\"speed\")\r\n            # Run the pump for the specified time\r\n            for remaining_time in range(run_time_s, 0, -1):\r\n                print(f\"Running... {remaining_time} seconds remaining\")\r\n                time.sleep(1)\r\n        finally:\r\n            self.stop(display_mode=\"speed\")\r\n\r\n#-----------------------------------------------------------------------#\r\n#   EXAMPLES ON HOW TO USE THE DEFINED CLASS TO CONTROL A LONGER PUMP   #\r\n#-----------------------------------------------------------------------#\r\n\r\npump = Longer_Pump(port='COM7', address=1)  # Adjust port and address as needed\r\npump.connect()\r\n\r\n# Run the pump at 40 rpm\r\npump.set_speed(40.00)  # Speed in RPM\r\npump.start(display_mode=\"speed\")  \r\npump.stop(display_mode=\"speed\")  \r\n\r\n# Set direction to counter-clockwise\r\npump.set_direction('CCW')\r\n\r\n# Run the pump in flow rate mode at 35 mL/min\r\npump.set_flow_rate(35)  # Flow rate in mL/min\r\npump.start(display_mode=\"flow_rate\")  \r\npump.stop(display_mode=\"flow_rate\")  # Stop the pump\r\n\r\n# Run the pump counter-clockwise at 10 RPM for 25 seconds\r\npump.run(speed_rpm=10.0, run_time_s=25, direction='CCW')\r\n\r\n# Disconnect the pump\r\npump.disconnect()</xmp>\n\t\t\t\t</code>\n\t\t\t</pre>\n\t\t</div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f8f66b9 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f8f66b9\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-218b725\" data-id=\"218b725\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-78c08b4 elementor-widget elementor-widget-heading\" data-id=\"78c08b4\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">Conclusie</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-ef40d76 elementor-widget elementor-widget-text-editor\" data-id=\"ef40d76\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>In deze blogpost hebben we besproken hoe je Longer peristaltische pompen kunt aansturen met het Modbus RTU-protocol, waarbij we inzicht gaven in de communicatieopmaak en een Python-bibliotheek hebben gedeeld om je op weg te helpen. Of je nu werkt met het L100-1S-2-model of de code aanpast voor een ander type pomp, we hopen dat deze handleiding van waarde is.</p><p>Blijf ons volgen voor meer tutorials en praktische toepassingen in toekomstige artikelen. Veel succes met pompen en programmeren tot dan! 💻</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e3fd84e elementor-widget elementor-widget-text-editor\" data-id=\"e3fd84e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><span style=\"font-weight: 400;\">📧 Als u vragen of opmerkingen heeft, neem dan gerust contact met ons op via </span><a href=\"https://darwin-microfluidics.com/nl/pages/contact\"><span style=\"font-weight: 400;\">support@darwin-microfluidics.com</span></a><span style=\"font-weight: 400;\">.</span></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-1aa74c2 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"1aa74c2\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Hulp nodig bij uw microfluïdica-project?\"><a href=\"https://darwin-microfluidics.com/nl/contact\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Neem contact op met onze experts!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Hulp nodig bij uw microfluïdica-project?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Wij maken microfluïdica voor u heel eenvoudig!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Peristaltic pumps play a crucial role in microfluidic research and medical diagnostics, offering precise fluid control with minimal risk of contamination. Among the many available options, Longer pumps, manufactured by Longer Precision Pump Co., Ltd., have gained a reputation for…</p>\n","protected":false},"author":4,"featured_media":19607,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[24,33],"tags":[],"class_list":["post-29503","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-flow-control","category-guides"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>How to Control Longer Pumps Using the Modbus RTU Protocol?</title>\n<meta name=\"description\" content=\"Leer hoe u Longer-pompen kunt aansturen via Modbus RTU en Python, met duidelijke richtlijnen voor het instellen van debieten en snelheden.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"How to Control Longer Pumps Using the Modbus RTU Protocol?\">\n<meta property=\"og:description\" content=\"Leer hoe u Longer-pompen kunt aansturen via Modbus RTU en Python, met duidelijke richtlijnen voor het instellen van debieten en snelheden.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-10-23T15:58:13+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:27:10+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/pump_img-1.png\">\n\t<meta property=\"og:image:width\" content=\"931\">\n\t<meta property=\"og:image:height\" content=\"850\">\n\t<meta property=\"og:image:type\" content=\"image/png\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"7 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"How to Control Longer Pumps Using the Modbus RTU Protocol?\",\"datePublished\":\"2024-10-23T15:58:13+00:00\",\"dateModified\":\"2026-11-19T14:27:10+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/\"},\"wordCount\":1509,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/pump_img-1.png\",\"articleSection\":[\"Flow control\",\"Guides &amp; tutorials\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/\",\"url\":\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/\",\"name\":\"How to Control Longer Pumps Using the Modbus RTU Protocol?\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/pump_img-1.png\",\"datePublished\":\"2024-10-23T15:58:13+00:00\",\"dateModified\":\"2026-11-19T14:27:10+00:00\",\"description\":\"Leer hoe u Longer-pompen kunt aansturen via Modbus RTU en Python, met duidelijke richtlijnen voor het instellen van debieten en snelheden.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/pump_img-1.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/pump_img-1.png\",\"width\":931,\"height\":850,\"caption\":\"An image of a Longer L100-1S-2 peristaltic pump without background\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"How to Control Longer Pumps Using the Modbus RTU Protocol?\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Onze blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/nl\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"How to Control Longer Pumps Using the Modbus RTU Protocol?","description":"Leer hoe u Longer-pompen kunt aansturen via Modbus RTU en Python, met duidelijke richtlijnen voor het instellen van debieten en snelheden.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/","og_locale":"en_US","og_type":"article","og_title":"How to Control Longer Pumps Using the Modbus RTU Protocol?","og_description":"Learn how to control Longer pumps via Modbus RTU and Python with clear guidance on setting flow rates and speeds.","og_url":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-10-23T15:58:13+00:00","article_modified_time":"2026-11-19T14:27:10+00:00","og_image":[{"width":931,"height":850,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/pump_img-1.png","type":"image/png"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"7 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"How to Control Longer Pumps Using the Modbus RTU Protocol?","datePublished":"2024-10-23T15:58:13+00:00","dateModified":"2026-11-19T14:27:10+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/"},"wordCount":1509,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/pump_img-1.png","articleSection":["Flow control","Guides &amp; tutorials"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/","url":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/","name":"How to Control Longer Pumps Using the Modbus RTU Protocol?","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/pump_img-1.png","datePublished":"2024-10-23T15:58:13+00:00","dateModified":"2026-11-19T14:27:10+00:00","description":"Leer hoe u Longer-pompen kunt aansturen via Modbus RTU en Python, met duidelijke richtlijnen voor het instellen van debieten en snelheden.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/pump_img-1.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/pump_img-1.png","width":931,"height":850,"caption":"An image of a Longer L100-1S-2 peristaltic pump without background"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/how-to-control-longer-pumps-using-the-modbus-rtu-protocol/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"How to Control Longer Pumps Using the Modbus RTU Protocol?"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Onze blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/03/pump_img-1.png","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/29503","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=29503"}],"version-history":[{"count":151,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/29503/revisions"}],"predecessor-version":[{"id":33682,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/29503/revisions/33682"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/19607"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=29503"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=29503"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=29503"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}