{"id":29809,"date":"2024-10-24T17:46:49","date_gmt":"2024-10-24T15:46:49","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=29809"},"modified":"2026-11-19T15:27:17","modified_gmt":"2026-11-19T14:27:17","slug":"puri-flex-chemical-compatibility-chart","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/","title":{"rendered":"Puri-Flex™ – Chemical Compatibility Chart"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"29809\" class=\"elementor elementor-29809\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-d670e60 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"d670e60\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-15099b8\" data-id=\"15099b8\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-5661292 elementor-widget elementor-widget-text-editor\" data-id=\"5661292\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bij het kiezen van <a href=\"https://darwin-microfluidics.com/nl/categorieen/microfluidic-slangen/\"><strong>tube</strong></a> voor <strong>microfluïdische</strong> toepassingen is het waarborgen van <strong>chemische compatibiliteit</strong> cruciaal voor het behoud van de integriteit en prestaties van het systeem. <a href=\"https://darwin-microfluidics.com/nl/producten/l-s-puri-flex-pump-tubing-7-6-m\"><strong>Puri-Flex™ tube</strong></a> is een goede keuze vanwege de uitstekende chemische compatibiliteit en treksterkte. Het is ontworpen voor farmaceutische en biotechnologische toepassingen, evenals voor omgevingen met hoge zuiverheidseisen waar geen contact met dierlijke componenten mag plaatsvinden, en is ideaal voor langdurige prestaties.</p><p>Net als alle andere materialen heeft Puri-Flex™ echter zijn beperkingen, en niet elke chemische stof is ermee compatibel. Daarom is inzicht in de compatibiliteit essentieel om aantasting van de „ tube “ te voorkomen en de veiligheid te waarborgen. In deze gids presenteren we een uitgebreide tabel met de chemische compatibiliteit van <strong>Puri-Flex™ tube</strong>. Deze tabel, gebaseerd op de door <a href=\"https://us.vwr.com/store/masterflex/tubingChemicalCompatibility.jsp\" target=\"_blank\" rel=\"noopener\">Masterflex®</a> verstrekte gegevens over chemische compatibiliteit (bij 21 °C), is bedoeld om ingenieurs, technici en onderzoekers te helpen snel te bepalen of Puri-Flex™ tube geschikt is voor hun specifieke toepassingen.</p><p>Raadpleeg deze tabel om weloverwogen keuzes te maken en de efficiëntie en veiligheid van uw systeem te waarborgen.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-94424ab elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"94424ab\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-2da2c7b\" data-id=\"2da2c7b\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-54042fd elementor-widget elementor-widget-text-editor\" data-id=\"54042fd\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>💡 De beoordelingssleutel voor chemische compatibiliteit is als volgt:</p><ul><li>A = Uitstekende chemische compatibiliteit (geen effect)</li><li>B = Goede chemische compatibiliteit (gering effect: lichte aantasting of verkleuring)</li><li>C = Redelijk (matig effect: niet aanbevolen voor continu gebruik; verzachting, verlies van sterkte, zwelling en/of krimp)</li><li>D = Ernstig effect (niet aanbevolen voor gebruik; ernstige verzachting, zwellen en/of krimpen)</li><li>n.v.t. = Geen gegevens beschikbaar</li></ul><p>🚨 <em>De compatibiliteitsbeoordelingen in deze tabellen dienen uitsluitend als algemene richtlijn en zijn mogelijk niet volledig of nauwkeurig. Ze houden geen rekening met potentiële contaminatie of veranderingen in vloeistofeigenschappen als gevolg van interactie met de tube. Wij bieden geen garantie met betrekking tot de geschiktheid van materialen voor specifieke doeleinden of de invloed van de tube op de vloeistofkwaliteit. Voer voor kritische toepassingen specifieke tests uit of win deskundig advies in.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e2610d3 elementor-widget elementor-widget-text-editor\" data-id=\"e2610d3\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2 class=\"h3 text-heading-default font-weight-bold\" data-class=\"text-heading-default\"><strong>Puri-Flex™- </strong>tube: Tabel met chemische compatibiliteit</h2>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-812a866 elementor-widget elementor-widget-shortcode\" data-id=\"812a866\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-57\" class=\"tablepress tablepress-id-57\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Chemische stof</th><th class=\"column-2\">Compatibiliteit</th>\n</tr>\n</thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">A</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Acetaldehyde</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Acetaat LMW</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Azijnzuur </td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Azijnzuur &gt;5%</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Azijnzuuranhydride</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Aceton</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Acetonitril</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Acetylbromide</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Acetylchloride</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Lucht</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Alifatische koolwaterstoffen</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Aluminiumchloride</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Aluminiumsulfaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Aluinen</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Ammoniak, gas / vloeistof</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Ammoniumacetaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Ammoniumcarbonaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">Ammoniumchloride</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">Ammoniumhydroxide</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">Ammoniumnitraat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">Ammoniumfosfaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">Ammoniumsulfaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">Amylacetaat</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">Amylalcohol</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">Amylchloride</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-28\">\n\t<td class=\"column-1\">Aniline</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-29\">\n\t<td class=\"column-1\">Anilinehydrochloride</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-30\">\n\t<td class=\"column-1\">Koningswater (80% HCl, 20% HNO3-equivalent)</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-31\">\n\t<td class=\"column-1\">Aromatische koolwaterstoffen</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-32\">\n\t<td class=\"column-1\">Arseenzouten</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-33\">\n\t<td class=\"column-1\">B</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-34\">\n\t<td class=\"column-1\">Bariumzouten</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-35\">\n\t<td class=\"column-1\">Benzaldehyde</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-36\">\n\t<td class=\"column-1\">Benzeensulfonzuur</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-37\">\n\t<td class=\"column-1\">Bleekvloeistoffen</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-38\">\n\t<td class=\"column-1\">Boorzuur</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-39\">\n\t<td class=\"column-1\">Broom</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-40\">\n\t<td class=\"column-1\">Butaan</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-41\">\n\t<td class=\"column-1\">Butanol (butylalcohol)</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-42\">\n\t<td class=\"column-1\">Butylacetaat</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-43\">\n\t<td class=\"column-1\">Boterzuur</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-44\">\n\t<td class=\"column-1\">C</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-45\">\n\t<td class=\"column-1\">Calciumoxide</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-46\">\n\t<td class=\"column-1\">Calciumzouten</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-47\">\n\t<td class=\"column-1\">Koolstofdisulfide</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-48\">\n\t<td class=\"column-1\">Koolstofdioxide</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-49\">\n\t<td class=\"column-1\">Koolstoftetrachloride</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-50\">\n\t<td class=\"column-1\">Chloor, droog</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-51\">\n\t<td class=\"column-1\">Chloor, nat</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-52\">\n\t<td class=\"column-1\">Chloorazijnzuur</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-53\">\n\t<td class=\"column-1\">Chloorbenzeen</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-54\">\n\t<td class=\"column-1\">Chloorbroommethaan</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-55\">\n\t<td class=\"column-1\">Chloroform</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-56\">\n\t<td class=\"column-1\">Chloorsulfonzuur</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-57\">\n\t<td class=\"column-1\">Chroomzuur, 30%</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-58\">\n\t<td class=\"column-1\">Chroomzouten</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-59\">\n\t<td class=\"column-1\">Koperzouten</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-60\">\n\t<td class=\"column-1\">Cresol</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-61\">\n\t<td class=\"column-1\">Cyclohexaan</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-62\">\n\t<td class=\"column-1\">Cyclohexanon</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-63\">\n\t<td class=\"column-1\">D</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-64\">\n\t<td class=\"column-1\">Diacetonalcohol</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-65\">\n\t<td class=\"column-1\">Dimethylformamide</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-66\">\n\t<td class=\"column-1\">Dimethylsulfoxide (DMSO)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-67\">\n\t<td class=\"column-1\">E</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-68\">\n\t<td class=\"column-1\">Etherische oliën</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-69\">\n\t<td class=\"column-1\">Ethanol (ethylalcohol)</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-70\">\n\t<td class=\"column-1\">Ether</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-71\">\n\t<td class=\"column-1\">Ethylacetaat</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-72\">\n\t<td class=\"column-1\">Ethylbromide</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-73\">\n\t<td class=\"column-1\">Ethylchloride</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-74\">\n\t<td class=\"column-1\">Ethylamine</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-75\">\n\t<td class=\"column-1\">Ethyleenchloorhydrine</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-76\">\n\t<td class=\"column-1\">Ethyleendichloride</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-77\">\n\t<td class=\"column-1\">Ethyleenglycol</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-78\">\n\t<td class=\"column-1\">Ethyleenoxide</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-79\">\n\t<td class=\"column-1\">F</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-80\">\n\t<td class=\"column-1\">Vetzuren</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-81\">\n\t<td class=\"column-1\">IJzer(III)chloride</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-82\">\n\t<td class=\"column-1\">IJzersulfaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-83\">\n\t<td class=\"column-1\">IJzerchloride</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-84\">\n\t<td class=\"column-1\">IJzersulfaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-85\">\n\t<td class=\"column-1\">Fluorboorzuur</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-86\">\n\t<td class=\"column-1\">Fluoroboraatzouten</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-87\">\n\t<td class=\"column-1\">Fluorkiezuur</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-88\">\n\t<td class=\"column-1\">Formaldehyde</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-89\">\n\t<td class=\"column-1\">Mierenzuur, 25%</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-90\">\n\t<td class=\"column-1\">Freon® TMS</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-91\">\n\t<td class=\"column-1\">G</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-92\">\n\t<td class=\"column-1\">Benzine, met een hoog gehalte aan aromatische koolwaterstoffen</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-93\">\n\t<td class=\"column-1\">Benzine, niet-aromatisch</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-94\">\n\t<td class=\"column-1\">Glucose</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-95\">\n\t<td class=\"column-1\">Lijm, P.V.A.</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-96\">\n\t<td class=\"column-1\">Glycerine</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-97\">\n\t<td class=\"column-1\">H</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-98\">\n\t<td class=\"column-1\">Waterstofjodidezuur</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-99\">\n\t<td class=\"column-1\">Waterstofbromidezuur, 30%</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-100\">\n\t<td class=\"column-1\">Zoutzuur (verdund)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-101\">\n\t<td class=\"column-1\">Zoutzuur (med.)</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-102\">\n\t<td class=\"column-1\">Zoutzuur (geconcentreerd)</td><td class=\"column-2\">N.v.t.</td>\n</tr>\n<tr class=\"row-103\">\n\t<td class=\"column-1\">Blauwzuur</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-104\">\n\t<td class=\"column-1\">Blauwzuur, gas, 10%</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-105\">\n\t<td class=\"column-1\">Waterstoffluoridezuur, 50%</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-106\">\n\t<td class=\"column-1\">Waterstoffluoridezuur, 75%</td><td class=\"column-2\">N.v.t.</td>\n</tr>\n<tr class=\"row-107\">\n\t<td class=\"column-1\">Waterstofperoxide (verdund)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-108\">\n\t<td class=\"column-1\">Waterstofperoxide, 90%</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-109\">\n\t<td class=\"column-1\">Hypochloorzuur</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-110\">\n\t<td class=\"column-1\">I</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-111\">\n\t<td class=\"column-1\">Jodiumoplossingen</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-112\">\n\t<td class=\"column-1\">Jodoform</td><td class=\"column-2\">N.v.t.</td>\n</tr>\n<tr class=\"row-113\">\n\t<td class=\"column-1\">K</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-114\">\n\t<td class=\"column-1\">Kerosine</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-115\">\n\t<td class=\"column-1\">Ketonen</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-116\">\n\t<td class=\"column-1\">L</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-117\">\n\t<td class=\"column-1\">Lakoplosmiddelen</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-118\">\n\t<td class=\"column-1\">Melkzuur, 3–10%</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-119\">\n\t<td class=\"column-1\">Loodacetaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-120\">\n\t<td class=\"column-1\">Lijnzaadolie</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-121\">\n\t<td class=\"column-1\">Lithiumhydroxide</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-122\">\n\t<td class=\"column-1\">M</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-123\">\n\t<td class=\"column-1\">Magnesiumchloride</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-124\">\n\t<td class=\"column-1\">Magnesiumsulfaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-125\">\n\t<td class=\"column-1\">Appelzuur</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-126\">\n\t<td class=\"column-1\">Mangaanzouten</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-127\">\n\t<td class=\"column-1\">Kwikzouten</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-128\">\n\t<td class=\"column-1\">Methaan</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-129\">\n\t<td class=\"column-1\">Methanol (methylalcohol)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-130\">\n\t<td class=\"column-1\">Methylchloride</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-131\">\n\t<td class=\"column-1\">Methylethylketon (MEK)</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-132\">\n\t<td class=\"column-1\">Mengzuur (40% H2SO4, 15% HNO3)</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-133\">\n\t<td class=\"column-1\">Molybdeendisulfide</td><td class=\"column-2\">N.v.t.</td>\n</tr>\n<tr class=\"row-134\">\n\t<td class=\"column-1\">Monoethanolamine</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-135\">\n\t<td class=\"column-1\">N</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-136\">\n\t<td class=\"column-1\">Nafta</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-137\">\n\t<td class=\"column-1\">Aardgas</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-138\">\n\t<td class=\"column-1\">Nikkelzouten</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-139\">\n\t<td class=\"column-1\">Salpeterzuur (verdund)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-140\">\n\t<td class=\"column-1\">Salpeterzuur (middel)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-141\">\n\t<td class=\"column-1\">Salpeterzuur (geconcentreerd)</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-142\">\n\t<td class=\"column-1\">Nitrobenzeen</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-143\">\n\t<td class=\"column-1\">Stikstofoxiden</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-144\">\n\t<td class=\"column-1\">Stikstofzuur</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-145\">\n\t<td class=\"column-1\">O</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-146\">\n\t<td class=\"column-1\">Oliën, dierlijke</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-147\">\n\t<td class=\"column-1\">Oliën, minerale</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-148\">\n\t<td class=\"column-1\">Plantaardige oliën</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-149\">\n\t<td class=\"column-1\">Oliezuur</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-150\">\n\t<td class=\"column-1\">Oxaalzuur, koud</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-151\">\n\t<td class=\"column-1\">Zuurstof, gas</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-152\">\n\t<td class=\"column-1\">P</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-153\">\n\t<td class=\"column-1\">Palmitinezuur, 100% in ether</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-154\">\n\t<td class=\"column-1\">Perchloorzuur</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-155\">\n\t<td class=\"column-1\">Perchloorethyleen</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-156\">\n\t<td class=\"column-1\">Fenol (carbolzuur)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-157\">\n\t<td class=\"column-1\">Fosforzuur, 50%</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-158\">\n\t<td class=\"column-1\">Ftaalzuur</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-159\">\n\t<td class=\"column-1\">Galvaniseeroplossingen</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-160\">\n\t<td class=\"column-1\">Polyglycol</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-161\">\n\t<td class=\"column-1\">Kaliumcarbonaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-162\">\n\t<td class=\"column-1\">Kaliumchloraat</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-163\">\n\t<td class=\"column-1\">Kaliumhydroxide (med)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-164\">\n\t<td class=\"column-1\">Kaliumhydroxide (geconcentreerd)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-165\">\n\t<td class=\"column-1\">Kaliumjodide</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-166\">\n\t<td class=\"column-1\">Propanol (propylalcohol)</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-167\">\n\t<td class=\"column-1\">Pyridine</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-168\">\n\t<td class=\"column-1\">S</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-169\">\n\t<td class=\"column-1\">Siliconenvloeistoffen</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-170\">\n\t<td class=\"column-1\">Siliconenoliën</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-171\">\n\t<td class=\"column-1\">Zilvernitraat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-172\">\n\t<td class=\"column-1\">Zeepoplossingen</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-173\">\n\t<td class=\"column-1\">Natriumbicarbonaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-174\">\n\t<td class=\"column-1\">Natriumbisulfaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-175\">\n\t<td class=\"column-1\">Natriumbisulfiet</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-176\">\n\t<td class=\"column-1\">Natriumboraat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-177\">\n\t<td class=\"column-1\">Natriumcarbonaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-178\">\n\t<td class=\"column-1\">Natriumchloraat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-179\">\n\t<td class=\"column-1\">Natriumchloride</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-180\">\n\t<td class=\"column-1\">Natriumferrocyanide</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-181\">\n\t<td class=\"column-1\">Natriumhydrosulfiet</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-182\">\n\t<td class=\"column-1\">Natriumhydroxide (verdund)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-183\">\n\t<td class=\"column-1\">Natriumhydroxide, 25%</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-184\">\n\t<td class=\"column-1\">Natriumhydroxide (geconcentreerd)</td><td class=\"column-2\">N.v.t.</td>\n</tr>\n<tr class=\"row-185\">\n\t<td class=\"column-1\">Natriumhypochloriet, </td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-186\">\n\t<td class=\"column-1\">Natriumhypochloriet, &gt;5%</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-187\">\n\t<td class=\"column-1\">Natriumnitraat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-188\">\n\t<td class=\"column-1\">Natriumsilicaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-189\">\n\t<td class=\"column-1\">Natriumsulfide</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-190\">\n\t<td class=\"column-1\">Natriumsulfiet</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-191\">\n\t<td class=\"column-1\">Stoom, tot 40 psi</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-192\">\n\t<td class=\"column-1\">Stearinezuur</td><td class=\"column-2\">C</td>\n</tr>\n<tr class=\"row-193\">\n\t<td class=\"column-1\">Styreen</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-194\">\n\t<td class=\"column-1\">Zwavelzuur (verdund)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-195\">\n\t<td class=\"column-1\">Zwavelzuur (med)</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-196\">\n\t<td class=\"column-1\">Zwavelzuur (geconcentreerd)</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-197\">\n\t<td class=\"column-1\">Zwavelzuur</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-198\">\n\t<td class=\"column-1\">T</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-199\">\n\t<td class=\"column-1\">Tanninezuur</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-200\">\n\t<td class=\"column-1\">Looivloeistoffen</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-201\">\n\t<td class=\"column-1\">Wijnsteenzuur</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-202\">\n\t<td class=\"column-1\">Tinzouten</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-203\">\n\t<td class=\"column-1\">Tolueen (tolueen)</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-204\">\n\t<td class=\"column-1\">Trichloorazijnzuur</td><td class=\"column-2\">B</td>\n</tr>\n<tr class=\"row-205\">\n\t<td class=\"column-1\">Trichloorethyleen</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-206\">\n\t<td class=\"column-1\">Trinatriumfosfaat</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-207\">\n\t<td class=\"column-1\">Terpentijn</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-208\">\n\t<td class=\"column-1\">U</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-209\">\n\t<td class=\"column-1\">Ureum</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-210\">\n\t<td class=\"column-1\">Urinezuur</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-211\">\n\t<td class=\"column-1\">W</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-212\">\n\t<td class=\"column-1\">Zoet water</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-213\">\n\t<td class=\"column-1\">Zout water</td><td class=\"column-2\">A</td>\n</tr>\n<tr class=\"row-214\">\n\t<td class=\"column-1\">X</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-215\">\n\t<td class=\"column-1\">Xyleen</td><td class=\"column-2\">D</td>\n</tr>\n<tr class=\"row-216\">\n\t<td class=\"column-1\">Z</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-217\">\n\t<td class=\"column-1\">Zinkchloride</td><td class=\"column-2\">A</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-57 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-2028486 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"2028486\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-c35f6de\" data-id=\"c35f6de\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-54a48c3 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"54a48c3\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Hulp nodig bij uw microfluïdica-project?\"><a href=\"https://darwin-microfluidics.com/nl/contact\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Neem contact op met onze experts!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Hulp nodig bij uw microfluïdica-project?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Wij maken microfluïdica voor u heel eenvoudig!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>When selecting tubing for microfluidic applications, ensuring chemical compatibility is crucial for maintaining system integrity and performance. Puri-Flex™ tubing is a good choice due to its excellent chemical compatibility and tensile strength. Designed for pharmaceutical and biotech applications, as well…</p>\n","protected":false},"author":4,"featured_media":29820,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[66,28,69],"tags":[],"class_list":["post-29809","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-chemical-compatibility","category-connectors-tubing","category-tubing"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Puri-Flex™ – Chemical Compatibility Chart</title>\n<meta name=\"description\" content=\"Bekijk de Puri-Flex™-tabel met chemische compatibiliteit om betrouwbare, duurzame tube -oplossingen te vinden voor diverse chemische omgevingen.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Puri-Flex™ – Chemical Compatibility Chart\">\n<meta property=\"og:description\" content=\"Bekijk de Puri-Flex™-tabel met chemische compatibiliteit om betrouwbare, duurzame tube -oplossingen te vinden voor diverse chemische omgevingen.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-10-24T15:46:49+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:27:17+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Puri-Flex-Pump-Tubing.jpg\">\n\t<meta property=\"og:image:width\" content=\"1920\">\n\t<meta property=\"og:image:height\" content=\"1920\">\n\t<meta property=\"og:image:type\" content=\"image/jpeg\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"2 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"Puri-Flex™ – Chemical Compatibility Chart\",\"datePublished\":\"2024-10-24T15:46:49+00:00\",\"dateModified\":\"2026-11-19T14:27:17+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/\"},\"wordCount\":298,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Puri-Flex-Pump-Tubing.jpg\",\"articleSection\":[\"Chemical compatibility charts\",\"Connectors &amp; tubing\",\"Tubing\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/\",\"url\":\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/\",\"name\":\"Puri-Flex™ – Chemical Compatibility Chart\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Puri-Flex-Pump-Tubing.jpg\",\"datePublished\":\"2024-10-24T15:46:49+00:00\",\"dateModified\":\"2026-11-19T14:27:17+00:00\",\"description\":\"Bekijk de Puri-Flex™-tabel met chemische compatibiliteit om betrouwbare, duurzame tube -oplossingen te vinden voor diverse chemische omgevingen.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Puri-Flex-Pump-Tubing.jpg\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Puri-Flex-Pump-Tubing.jpg\",\"width\":1920,\"height\":1920,\"caption\":\"Puri-Flex Pump Tubing\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Puri-Flex™ – Chemical Compatibility Chart\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Onze blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/nl\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Puri-Flex™ – Chemical Compatibility Chart","description":"Bekijk de Puri-Flex™-tabel met chemische compatibiliteit om betrouwbare, duurzame tube -oplossingen te vinden voor diverse chemische omgevingen.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/","og_locale":"en_US","og_type":"article","og_title":"Puri-Flex™ – Chemical Compatibility Chart","og_description":"Explore the Puri-Flex™ chemical compatibility chart to find reliable, durable tubing solutions for various chemical environments.","og_url":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-10-24T15:46:49+00:00","article_modified_time":"2026-11-19T14:27:17+00:00","og_image":[{"width":1920,"height":1920,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Puri-Flex-Pump-Tubing.jpg","type":"image/jpeg"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"2 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"Puri-Flex™ – Chemical Compatibility Chart","datePublished":"2024-10-24T15:46:49+00:00","dateModified":"2026-11-19T14:27:17+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/"},"wordCount":298,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Puri-Flex-Pump-Tubing.jpg","articleSection":["Chemical compatibility charts","Connectors &amp; tubing","Tubing"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/","url":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/","name":"Puri-Flex™ – Chemical Compatibility Chart","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Puri-Flex-Pump-Tubing.jpg","datePublished":"2024-10-24T15:46:49+00:00","dateModified":"2026-11-19T14:27:17+00:00","description":"Bekijk de Puri-Flex™-tabel met chemische compatibiliteit om betrouwbare, duurzame tube -oplossingen te vinden voor diverse chemische omgevingen.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Puri-Flex-Pump-Tubing.jpg","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Puri-Flex-Pump-Tubing.jpg","width":1920,"height":1920,"caption":"Puri-Flex Pump Tubing"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/puri-flex-chemical-compatibility-chart/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Puri-Flex™ – Chemical Compatibility Chart"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Onze blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/10/Puri-Flex-Pump-Tubing.jpg","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/29809","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=29809"}],"version-history":[{"count":19,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/29809/revisions"}],"predecessor-version":[{"id":29835,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/29809/revisions/29835"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/29820"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=29809"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=29809"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=29809"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}