{"id":30477,"date":"2024-11-21T11:19:11","date_gmt":"2024-11-21T10:19:11","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=30477"},"modified":"2026-11-19T15:33:37","modified_gmt":"2026-11-19T14:33:37","slug":"electron-beam-sterilization-compatibility-chart","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/","title":{"rendered":"Electron Beam – Sterilization Compatibility Chart"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"30477\" class=\"elementor elementor-30477\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-f20820b elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"f20820b\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-587f0ef\" data-id=\"587f0ef\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-e9832e8 elementor-widget elementor-widget-text-editor\" data-id=\"e9832e8\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p><strong>Elektronenstraling (e-beam)</strong> <strong>sterilisatie</strong> is een veelgebruikte techniek voor het steriliseren van materialen die gevoelig zijn voor hitte en vocht. Het wordt toegepast in medische, biologische en <strong>microfluïdica-toepassingen</strong> omdat het effectief steriliseert zonder dat materialen worden blootgesteld aan hoge temperaturen.</p><p>Deze methode werkt door hoogenergetische elektrononenbundels op materialen te richten in een gecontroleerde omgeving. De elektronen dringen door in het materiaal, verstoren het microbiële DNA en waarborgen zo de steriliteit. Als niet-thermisch proces is e-beamsterilisatie bijzonder geschikt voor kwetsbare materialen die de hitte van traditionele methoden, zoals autoclaven of stoomsterilisatie, niet kunnen weerstaan. Wel is voorzichtigheid geboden om overmatige blootstelling te voorkomen, aangezien te veel straling kan leiden tot materiaaldegradatie.</p><p>Om ingenieurs en onderzoekers te helpen begrijpen hoe verschillende materialen zich gedragen onder elektronendosering, biedt de volgende uitgebreide <a href=\"#chart\">tabel</a>—afkomstig uit diverse bronnen waaronder <a href=\"https://www.qosina.com/\" target=\"_blank\" rel=\"noopener\">Qosina</a>, <a href=\"https://www.idex-hs.com/home\" target=\"_blank\" rel=\"noopener\">Idex</a> en <a href=\"https://www.industrialspec.com/\" target=\"_blank\" rel=\"noopener\">Industrial Specialties Mfg.</a>—compatibiliteitsscores.</p><p>Raadpleeg deze tabel om weloverwogen keuzes te maken en experimenten vrij van contaminatie te houden.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-dc896a2 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"dc896a2\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9add8cb\" data-id=\"9add8cb\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-004f208 elementor-widget elementor-widget-text-editor\" data-id=\"004f208\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>💡 De sleutel voor de sterilisatiecompatibiliteitsbeoordeling is als volgt:</p><ul><li>Goed = weinig tot geen effect</li><li>Matig = Licht tot matig effect</li><li>Slecht = Matig tot ernstig effect (niet aanbevolen)</li></ul><p>🚨 <em>Deze tabel is uitsluitend bedoeld voor informatieve doeleinden en mag niet worden beschouwd als een garantie voor materiaalefficiëntie bij sterilisatie of andere toepassingen. Gebruikers zijn zelf verantwoordelijk voor het beoordelen van de geschiktheid van materialen en processen voor hun specifieke toepassingen, waarbij zowel technische als juridische overwegingen in acht moeten worden genomen.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-a2dbb87 elementor-widget elementor-widget-heading\" data-id=\"a2dbb87\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"heading.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<h2 class=\"elementor-heading-title elementor-size-default\">⚡ Elektronenstraal: Overzicht van geschiktheid voor sterilisatie</h2>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-2dfd251 elementor-widget elementor-widget-shortcode\" data-id=\"2dfd251\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"chart\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-99\" class=\"tablepress tablepress-id-99\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Materiaal</th><th class=\"column-2\">Elektronenstraal</th>\n</tr>\n</thead>\n<tbody class=\"row-striping row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">Aluminium</td><td class=\"column-2\">N.v.t.</td>\n</tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Cyclo-olefinecopolymeer (COC)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Cyclo-olefinepolymeer (COP)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Ethyleenchlorotrifluorethyleen (ECTFE)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Ethyleen-propyleen-dieenmonomeer (EPDM)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Ethyleentetrafluorethyleen (Tefzel - ETFE)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Gefluoreerd ethyleenpropyleen (FEP)</td><td class=\"column-2\">Matig</td>\n</tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Polyethyleen met hoge dichtheid (HDPE)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Polypropyleen met hoge dichtheid (HDPP)</td><td class=\"column-2\">N.v.t.</td>\n</tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Polycarbonaat (PC) voor hoge temperaturen</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Lineair polyethyleen met lagedichtheid (LLDPE)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Polyethyleen met lage dichtheid (LDPE)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Neopreen</td><td class=\"column-2\">N.v.t.</td>\n</tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Thermoplastisch olefine-elastomeer (TPO)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Perfluoroalkoxy (PFA)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Perfluoro-elastomeer (FFKM)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Polyamide (nylon)</td><td class=\"column-2\">Matig</td>\n</tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Thermoplastisch polyamide-elastomeer (TPA)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">Polycarbonaat (PC)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">Polychloortrifluorethyleen (PCTFE)</td><td class=\"column-2\">Matig</td>\n</tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">Polydimethylsiloxaan (PDMS)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">Polyetheretherketon (PEEK)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">Polyethyleen (PE)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">Polymethylmethacrylaat (PMMA)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">Polyoxymethyleen (Delrin)</td><td class=\"column-2\">Slecht</td>\n</tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">Polyphenyleensulfide (PPS)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-28\">\n\t<td class=\"column-1\">Polyphenylsulfon (PPSU)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-29\">\n\t<td class=\"column-1\">Polypropyleen (PP)</td><td class=\"column-2\">Matig</td>\n</tr>\n<tr class=\"row-30\">\n\t<td class=\"column-1\">Polystyreen (PS)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-31\">\n\t<td class=\"column-1\">Polysulfon (PSU)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-32\">\n\t<td class=\"column-1\">Polytetrafluorethyleen (PTFE)</td><td class=\"column-2\">Slecht</td>\n</tr>\n<tr class=\"row-33\">\n\t<td class=\"column-1\">Polyurethaan (PU)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-34\">\n\t<td class=\"column-1\">Polyvinylchloride (PVC)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-35\">\n\t<td class=\"column-1\">Polyvinylchloride (ongeplastificeerd – PVC)</td><td class=\"column-2\">Matig</td>\n</tr>\n<tr class=\"row-36\">\n\t<td class=\"column-1\">Polyvinylfluoride (PVF)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-37\">\n\t<td class=\"column-1\">Siliconen</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-38\">\n\t<td class=\"column-1\">Roestvrij staal 316</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-39\">\n\t<td class=\"column-1\">Thermoplastische polyolefine (TPO)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-40\">\n\t<td class=\"column-1\">Thermoplastisch polyurethaan (TPU)</td><td class=\"column-2\">Goed</td>\n</tr>\n<tr class=\"row-41\">\n\t<td class=\"column-1\">Ultrahigh Molecular Weight Polyethylene (UHMWPE)</td><td class=\"column-2\">Goed</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-99 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-ab72714 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"ab72714\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-9ec0016\" data-id=\"9ec0016\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6fdcce5 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"6fdcce5\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Hulp nodig bij uw microfluïdica-project?\"><a href=\"https://darwin-microfluidics.com/nl/contact\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Neem contact op met onze experts!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Hulp nodig bij uw microfluïdica-project?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Wij maken microfluïdica voor u heel eenvoudig!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>Electron Beam (e-beam) sterilization is a commonly utilized technique for sterilizing materials sensitive to heat and moisture. It is used in medical, biological, and microfluidic applications because it effectively sterilizes without subjecting materials to high temperatures. This method works by…</p>\n","protected":false},"author":4,"featured_media":30581,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[27,66,72],"tags":[],"class_list":["post-30477","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-cell-culture-organ-on-chip","category-chemical-compatibility","category-sterilization"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Elektronenstraal – Overzicht van geschiktheid voor sterilisatie</title>\n<meta name=\"description\" content=\"Ontdek de compatibiliteitstabel voor elektronenstralingsterilisatie om te zien welke materialen geschikt zijn voor een veilige en effectieve e-beamsterilisatie.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Elektronenstraal – Overzicht van geschiktheid voor sterilisatie\">\n<meta property=\"og:description\" content=\"Ontdek de compatibiliteitstabel voor elektronenstralingsterilisatie om te zien welke materialen geschikt zijn voor een veilige en effectieve e-beamsterilisatie.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-11-21T10:19:11+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:33:37+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization-1024x585.png\">\n\t<meta property=\"og:image:width\" content=\"1024\">\n\t<meta property=\"og:image:height\" content=\"585\">\n\t<meta property=\"og:image:type\" content=\"image/png\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"2 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"Electron Beam – Sterilization Compatibility Chart\",\"datePublished\":\"2024-11-21T10:19:11+00:00\",\"dateModified\":\"2026-11-19T14:33:37+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\"},\"wordCount\":247,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png\",\"articleSection\":[\"Cell culture &amp; organ-on-chip\",\"Chemical compatibility charts\",\"Sterilization\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\",\"url\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\",\"name\":\"Electron Beam – Sterilization Compatibility Chart\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png\",\"datePublished\":\"2024-11-21T10:19:11+00:00\",\"dateModified\":\"2026-11-19T14:33:37+00:00\",\"description\":\"Ontdek de compatibiliteitstabel voor elektronenstralingsterilisatie om te zien welke materialen geschikt zijn voor een veilige en effectieve e-beamsterilisatie.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png\",\"width\":1792,\"height\":1024,\"caption\":\"Electron beam (e-beam) sterilization\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Electron Beam – Sterilization Compatibility Chart\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Onze blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/nl\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Electron Beam – Sterilization Compatibility Chart","description":"Ontdek de compatibiliteitstabel voor elektronenstralingsterilisatie om te zien welke materialen geschikt zijn voor een veilige en effectieve e-beamsterilisatie.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/","og_locale":"en_US","og_type":"article","og_title":"Electron Beam – Sterilization Compatibility Chart","og_description":"Discover the Electron Beam Sterilization Compatibility Chart to see which materials are suitable for safe and effective e-beam sterilization.","og_url":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-11-21T10:19:11+00:00","article_modified_time":"2026-11-19T14:33:37+00:00","og_image":[{"width":1024,"height":585,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization-1024x585.png","type":"image/png"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"2 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"Electron Beam – Sterilization Compatibility Chart","datePublished":"2024-11-21T10:19:11+00:00","dateModified":"2026-11-19T14:33:37+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/"},"wordCount":247,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png","articleSection":["Cell culture &amp; organ-on-chip","Chemical compatibility charts","Sterilization"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/","url":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/","name":"Electron Beam – Sterilization Compatibility Chart","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png","datePublished":"2024-11-21T10:19:11+00:00","dateModified":"2026-11-19T14:33:37+00:00","description":"Ontdek de compatibiliteitstabel voor elektronenstralingsterilisatie om te zien welke materialen geschikt zijn voor een veilige en effectieve e-beamsterilisatie.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png","width":1792,"height":1024,"caption":"Electron beam (e-beam) sterilization"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/electron-beam-sterilization-compatibility-chart/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Electron Beam – Sterilization Compatibility Chart"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Onze blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Electron-beam-e-beam-sterilization.png","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30477","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=30477"}],"version-history":[{"count":19,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30477/revisions"}],"predecessor-version":[{"id":30587,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30477/revisions/30587"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/30581"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=30477"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=30477"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=30477"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}