{"id":30625,"date":"2024-11-22T17:47:56","date_gmt":"2024-11-22T16:47:56","guid":{"rendered":"https://blog.darwin-microfluidics.com/?p=30625"},"modified":"2026-11-19T15:33:56","modified_gmt":"2026-11-19T14:33:56","slug":"solva-chemical-resistance-chart","status":"publish","type":"post","link":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/","title":{"rendered":"Solva – Chemical Resistance Chart"},"content":{"rendered":"<div data-elementor-type=\"wp-post\" data-elementor-id=\"30625\" class=\"elementor elementor-30625\" data-elementor-post-type=\"post\">\n\t\t\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-b3398d8 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"b3398d8\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-a66f972\" data-id=\"a66f972\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-0e01c23 elementor-widget elementor-widget-text-editor\" data-id=\"0e01c23\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>Bij het selecteren van <a href=\"https://darwin-microfluidics.com/nl/categorieen/microfluidic-slangen/\"><strong>tube</strong></a> voor <strong>microfluidische toepassingen</strong>, is <strong>chemische resistentie</strong> cruciaal voor het behoud van de systeemintegriteit. <a href=\"https://darwin-microfluidics.com/nl/categorieen/microfluidic-slangen/?page=1&amp;rb_custom_field_eec34d804c9ce6c89cff596be555e6a4=Solva\"><strong>Solva</strong></a> wordt gewaardeerd om zijn duurzaamheid, chemische bestendigheid en veelzijdigheid, waardoor het geschikt is voor uiteenlopende toepassingen.</p><p>Solva is echter niet compatibel met alle chemicaliën, dus het begrijpen van de resistentie is essentieel voor veiligheid en prestaties. Deze gids biedt een chemische resistentietabel voor Solva tube, gebaseerd op gegevens van <a href=\"https://ormantineusa.com/\" target=\"_blank\" rel=\"noopener\">Ormantine</a>, waarmee gebruikers snel de geschiktheid voor specifieke toepassingen kunnen beoordelen.</p><p>Raadpleeg deze tabel om weloverwogen keuzes te maken en de efficiëntie en veiligheid van uw systeem te waarborgen.</p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1eca374 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1eca374\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-07fc0f2\" data-id=\"07fc0f2\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-6a9e86e elementor-widget elementor-widget-text-editor\" data-id=\"6a9e86e\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p>💡 De beoordelingssleutel voor chemische resistentie is als volgt:</p><ul><li>bestand = geen tot geringe invloed</li><li>niet resistent = matig tot ernstig effect</li></ul><p>🚨 <em>De compatibiliteitsbeoordelingen in deze tabellen dienen uitsluitend als algemene richtlijn en zijn mogelijk niet volledig of nauwkeurig. Ze houden geen rekening met potentiële contaminatie of veranderingen in vloeistofeigenschappen als gevolg van interactie met de tube. Wij bieden geen garantie met betrekking tot de geschiktheid van materialen voor specifieke doeleinden of de invloed van de tube op de vloeistofkwaliteit. Voer voor kritische toepassingen specifieke tests uit of win deskundig advies in.</em></p>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-e9808b0 elementor-widget elementor-widget-text-editor\" data-id=\"e9808b0\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<h2><strong>Solva Tube</strong>: Compatibiliteitstabel voor chemicaliën</h2>\t\t\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t<div class=\"elementor-element elementor-element-5afd4db elementor-widget elementor-widget-shortcode\" data-id=\"5afd4db\" data-element_type=\"widget\" data-e-type=\"widget\" data-widget_type=\"shortcode.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t<div class=\"elementor-shortcode\">\n<table id=\"tablepress-101\" class=\"tablepress tablepress-id-101\">\n<thead>\n<tr class=\"row-1\">\n\t<th class=\"column-1\">Chemische stof</th><th class=\"column-2\">Chemische bestendigheid</th>\n</tr>\n</thead>\n<tbody class=\"row-hover\">\n<tr class=\"row-2\">\n\t<td class=\"column-1\">A</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-3\">\n\t<td class=\"column-1\">Acetaldehyde</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-4\">\n\t<td class=\"column-1\">Acetaten (laag mol. gew.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-5\">\n\t<td class=\"column-1\">Azijnzuur (</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-6\">\n\t<td class=\"column-1\">Azijnzuur (&gt;5%)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-7\">\n\t<td class=\"column-1\">Azijnzuuranhydride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-8\">\n\t<td class=\"column-1\">Aceton</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-9\">\n\t<td class=\"column-1\">Acetylbromide</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-10\">\n\t<td class=\"column-1\">Acetylchloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-11\">\n\t<td class=\"column-1\">Lucht</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-12\">\n\t<td class=\"column-1\">Alcoholen</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-13\">\n\t<td class=\"column-1\">Alifatische koolwaterstoffen</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-14\">\n\t<td class=\"column-1\">Aluminiumchloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-15\">\n\t<td class=\"column-1\">Alsulfaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-16\">\n\t<td class=\"column-1\">Aluinen</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-17\">\n\t<td class=\"column-1\">Ammoniak (gas-vloeistof)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-18\">\n\t<td class=\"column-1\">Ammoniumacetaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-19\">\n\t<td class=\"column-1\">Ammoniumcarbonaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-20\">\n\t<td class=\"column-1\">Ammoniumchloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-21\">\n\t<td class=\"column-1\">Ammoniumhydroxide</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-22\">\n\t<td class=\"column-1\">Ammoniumnitraat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-23\">\n\t<td class=\"column-1\">Ammoniumfosfaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-24\">\n\t<td class=\"column-1\">Ammoniumsulfaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-25\">\n\t<td class=\"column-1\">Amylacetaat</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-26\">\n\t<td class=\"column-1\">Amylalcohol</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-27\">\n\t<td class=\"column-1\">Amylchloride</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-28\">\n\t<td class=\"column-1\">Aniline</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-29\">\n\t<td class=\"column-1\">Anilinehydrochloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-30\">\n\t<td class=\"column-1\">Dierlijke oliën</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-31\">\n\t<td class=\"column-1\">Antimoonzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-32\">\n\t<td class=\"column-1\">Koninginnewater</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-33\">\n\t<td class=\"column-1\">Aromatische koolwaterstoffen</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-34\">\n\t<td class=\"column-1\">Arseenzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-35\">\n\t<td class=\"column-1\">B</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-36\">\n\t<td class=\"column-1\">Bariumzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-37\">\n\t<td class=\"column-1\">Benzaldehyde</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-38\">\n\t<td class=\"column-1\">Benzeen</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-39\">\n\t<td class=\"column-1\">Benzeensulfonzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-40\">\n\t<td class=\"column-1\">Benzoëzuur</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-41\">\n\t<td class=\"column-1\">Benzylalcohol</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-42\">\n\t<td class=\"column-1\">Bleekvloeistoffen</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-43\">\n\t<td class=\"column-1\">Boorzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-44\">\n\t<td class=\"column-1\">Broom</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-45\">\n\t<td class=\"column-1\">Butaan</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-46\">\n\t<td class=\"column-1\">Butanol</td><td class=\"column-2\">N.v.t.</td>\n</tr>\n<tr class=\"row-47\">\n\t<td class=\"column-1\">Butylacetaat</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-48\">\n\t<td class=\"column-1\">Boterzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-49\">\n\t<td class=\"column-1\">C</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-50\">\n\t<td class=\"column-1\">Calciumzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-51\">\n\t<td class=\"column-1\">Koolstofdisulfide</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-52\">\n\t<td class=\"column-1\">Koolstofdioxide</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-53\">\n\t<td class=\"column-1\">Koolstoftetrachloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-54\">\n\t<td class=\"column-1\">Chloorazijnzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-55\">\n\t<td class=\"column-1\">Chloorbenzeen</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-56\">\n\t<td class=\"column-1\">Chloor (droog)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-57\">\n\t<td class=\"column-1\">Chloor (nat)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-58\">\n\t<td class=\"column-1\">Chloroform</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-59\">\n\t<td class=\"column-1\">Chloorsulfonzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-60\">\n\t<td class=\"column-1\">Chroomzuur</td><td class=\"column-2\">N.v.t.</td>\n</tr>\n<tr class=\"row-61\">\n\t<td class=\"column-1\">Chroomzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-62\">\n\t<td class=\"column-1\">Koperzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-63\">\n\t<td class=\"column-1\">Cresol</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-64\">\n\t<td class=\"column-1\">Cyclohexanon</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-65\">\n\t<td class=\"column-1\">E</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-66\">\n\t<td class=\"column-1\">Etherische oliën</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-67\">\n\t<td class=\"column-1\">Ethers</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-68\">\n\t<td class=\"column-1\">Ethylacetaat</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-69\">\n\t<td class=\"column-1\">Ethylalcohol</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-70\">\n\t<td class=\"column-1\">Ethylbromide</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-71\">\n\t<td class=\"column-1\">Ethylchloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-72\">\n\t<td class=\"column-1\">Ethylamine</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-73\">\n\t<td class=\"column-1\">Ethyleenchloorhydrine</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-74\">\n\t<td class=\"column-1\">Ethyleendichloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-75\">\n\t<td class=\"column-1\">Ethyleenglycol</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-76\">\n\t<td class=\"column-1\">F</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-77\">\n\t<td class=\"column-1\">Vetzuren</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-78\">\n\t<td class=\"column-1\">IJzer(III)chloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-79\">\n\t<td class=\"column-1\">IJzersulfaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-80\">\n\t<td class=\"column-1\">IJzerchloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-81\">\n\t<td class=\"column-1\">IJzersulfaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-82\">\n\t<td class=\"column-1\">Fluorkiezelsuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-83\">\n\t<td class=\"column-1\">Fluoboraatzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-84\">\n\t<td class=\"column-1\">Fluorboorzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-85\">\n\t<td class=\"column-1\">Formaldehyde</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-86\">\n\t<td class=\"column-1\">Mierenzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-87\">\n\t<td class=\"column-1\">Freon</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-88\">\n\t<td class=\"column-1\">G</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-89\">\n\t<td class=\"column-1\">Benzine (hoog aromatisch)</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-90\">\n\t<td class=\"column-1\">Benzine (niet-aromatisch)</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-91\">\n\t<td class=\"column-1\">Glucose</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-92\">\n\t<td class=\"column-1\">Lijm</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-93\">\n\t<td class=\"column-1\">Glycerine</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-94\">\n\t<td class=\"column-1\">H</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-95\">\n\t<td class=\"column-1\">Waterstofjodidezuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-96\">\n\t<td class=\"column-1\">Waterstofbromidezuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-97\">\n\t<td class=\"column-1\">Zoutzuur (gem. conc.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-98\">\n\t<td class=\"column-1\">Zoutzuur (geconcentreerd)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-99\">\n\t<td class=\"column-1\">Zoutzuur (verdund)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-100\">\n\t<td class=\"column-1\">Blauwzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-101\">\n\t<td class=\"column-1\">Waterstoffluoridezuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-102\">\n\t<td class=\"column-1\">Waterstofperoxide (verdund)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-103\">\n\t<td class=\"column-1\">Waterstofperoxide (geconc.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-104\">\n\t<td class=\"column-1\">Waterstofsulfide</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-105\">\n\t<td class=\"column-1\">Hypochloorzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-106\">\n\t<td class=\"column-1\">I</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-107\">\n\t<td class=\"column-1\">Jodium en oplossingen</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-108\">\n\t<td class=\"column-1\">K</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-109\">\n\t<td class=\"column-1\">Kerosine</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-110\">\n\t<td class=\"column-1\">Ketonen</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-111\">\n\t<td class=\"column-1\">L</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-112\">\n\t<td class=\"column-1\">Melkzuur</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-113\">\n\t<td class=\"column-1\">Lakoplosmiddelen</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-114\">\n\t<td class=\"column-1\">Loodacetaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-115\">\n\t<td class=\"column-1\">Lijnzaadolie</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-116\">\n\t<td class=\"column-1\">M</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-117\">\n\t<td class=\"column-1\">Magnesiumchloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-118\">\n\t<td class=\"column-1\">Magnesiumsulfaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-119\">\n\t<td class=\"column-1\">Appelzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-120\">\n\t<td class=\"column-1\">Mangaanzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-121\">\n\t<td class=\"column-1\">Kwikzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-122\">\n\t<td class=\"column-1\">N</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-123\">\n\t<td class=\"column-1\">Nafta</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-124\">\n\t<td class=\"column-1\">Aardgas</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-125\">\n\t<td class=\"column-1\">Nikkelzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-126\">\n\t<td class=\"column-1\">Salpeterzuur (geconc.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-127\">\n\t<td class=\"column-1\">Salpeterzuur (verd.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-128\">\n\t<td class=\"column-1\">Salpeterzuur (gem. conc.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-129\">\n\t<td class=\"column-1\">Nitrobenzeen</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-130\">\n\t<td class=\"column-1\">Stikstofoxiden</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-131\">\n\t<td class=\"column-1\">Stikstofzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-132\">\n\t<td class=\"column-1\">O</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-133\">\n\t<td class=\"column-1\">Oliën, dierlijke</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-134\">\n\t<td class=\"column-1\">Oliën, minerale</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-135\">\n\t<td class=\"column-1\">Plantaardige oliën</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-136\">\n\t<td class=\"column-1\">Oliezuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-137\">\n\t<td class=\"column-1\">Oxaalzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-138\">\n\t<td class=\"column-1\">Zuurstof (gas)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-139\">\n\t<td class=\"column-1\">P</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-140\">\n\t<td class=\"column-1\">Perchloorzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-141\">\n\t<td class=\"column-1\">Fenol</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-142\">\n\t<td class=\"column-1\">Fosforzuur (ortho.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-143\">\n\t<td class=\"column-1\">Ftaalzuur</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-144\">\n\t<td class=\"column-1\">Galvaniseeroplossingen</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-145\">\n\t<td class=\"column-1\">Kaliumcarbonaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-146\">\n\t<td class=\"column-1\">Kaliumchloraat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-147\">\n\t<td class=\"column-1\">Kaliumhydroxide</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-148\">\n\t<td class=\"column-1\">Kaliumjodide</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-149\">\n\t<td class=\"column-1\">Pyridine</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-150\">\n\t<td class=\"column-1\">S</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-151\">\n\t<td class=\"column-1\">Zilvernitraat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-152\">\n\t<td class=\"column-1\">Zeepoplossingen</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-153\">\n\t<td class=\"column-1\">Natriumbicarbonaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-154\">\n\t<td class=\"column-1\">Natriumbisulfaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-155\">\n\t<td class=\"column-1\">Natriumbisulfiet</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-156\">\n\t<td class=\"column-1\">Natriumboraat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-157\">\n\t<td class=\"column-1\">Natriumcarbonaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-158\">\n\t<td class=\"column-1\">Natriumchloraat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-159\">\n\t<td class=\"column-1\">Natriumchloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-160\">\n\t<td class=\"column-1\">Natriumferrocyanide</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-161\">\n\t<td class=\"column-1\">Natriumhydrosulfiet</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-162\">\n\t<td class=\"column-1\">Natriumhydroxide (gec.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-163\">\n\t<td class=\"column-1\">Natriumhydroxide (verd.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-164\">\n\t<td class=\"column-1\">Natriumhydroxide (gem. conc.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-165\">\n\t<td class=\"column-1\">Natriumhypochloriet</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-166\">\n\t<td class=\"column-1\">Natriumnitraat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-167\">\n\t<td class=\"column-1\">Natriumsilicaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-168\">\n\t<td class=\"column-1\">Natriumsulfide</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-169\">\n\t<td class=\"column-1\">Natriumsulfiet</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-170\">\n\t<td class=\"column-1\">Stearinezuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-171\">\n\t<td class=\"column-1\">Zwavelchloride</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-172\">\n\t<td class=\"column-1\">Zwaveldioxide</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-173\">\n\t<td class=\"column-1\">Zwaveltrioxide</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-174\">\n\t<td class=\"column-1\">Zwavelzuur (conc.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-175\">\n\t<td class=\"column-1\">Zwavelzuur (verdund)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-176\">\n\t<td class=\"column-1\">Zwavelzuur (gem. conc.)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-177\">\n\t<td class=\"column-1\">Zwavelzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-178\">\n\t<td class=\"column-1\">T</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-179\">\n\t<td class=\"column-1\">Tanninezuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-180\">\n\t<td class=\"column-1\">Looiextracten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-181\">\n\t<td class=\"column-1\">Wijnsteenzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-182\">\n\t<td class=\"column-1\">Tinzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-183\">\n\t<td class=\"column-1\">Titaanzouten</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-184\">\n\t<td class=\"column-1\">Tolueen</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-185\">\n\t<td class=\"column-1\">Trinatriumfosfaat</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-186\">\n\t<td class=\"column-1\">Trichloorazijnzuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-187\">\n\t<td class=\"column-1\">Terpentijn</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-188\">\n\t<td class=\"column-1\">U</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-189\">\n\t<td class=\"column-1\">Ureum</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-190\">\n\t<td class=\"column-1\">Urinezuur</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-191\">\n\t<td class=\"column-1\">W</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-192\">\n\t<td class=\"column-1\">Water</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-193\">\n\t<td class=\"column-1\">Water (pekel)</td><td class=\"column-2\">bestand</td>\n</tr>\n<tr class=\"row-194\">\n\t<td class=\"column-1\">X</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-195\">\n\t<td class=\"column-1\">Xylol</td><td class=\"column-2\">niet bestand</td>\n</tr>\n<tr class=\"row-196\">\n\t<td class=\"column-1\">Z</td><td class=\"column-2\"></td>\n</tr>\n<tr class=\"row-197\">\n\t<td class=\"column-1\">Zinkchloride</td><td class=\"column-2\">bestand</td>\n</tr>\n</tbody>\n</table>\n<!-- #tablepress-101 from cache --></div>\n\t\t\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t<section class=\"elementor-section elementor-top-section elementor-element elementor-element-1a34594 elementor-section-boxed elementor-section-height-default elementor-section-height-default\" data-id=\"1a34594\" data-element_type=\"section\" data-e-type=\"section\">\n\t\t\t\t\t\t<div class=\"elementor-container elementor-column-gap-default\">\n\t\t\t\t\t<div class=\"elementor-column elementor-col-100 elementor-top-column elementor-element elementor-element-55fa523\" data-id=\"55fa523\" data-element_type=\"column\" data-e-type=\"column\">\n\t\t\t<div class=\"elementor-widget-wrap elementor-element-populated\">\n\t\t\t\t\t\t<div class=\"elementor-element elementor-element-18550 elementor-widget elementor-widget-global elementor-global-18550 elementor-widget-pix-promo-box\" data-id=\"18550\" data-element_type=\"widget\" data-e-type=\"widget\" id=\"cta2\" data-widget_type=\"pix-promo-box.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t<div class=\"pix-promo-box card w-100 h-1002 bg-heading-default  pix-hover-item rounded-10 position-relative overflow-hidden text-white   text-left w-100 d-block\"><img decoding=\"async\" src=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/image-WTTJ-1-1.jpg\" class=\"card-img pix-bg-image pix-img-scale h-100 rounded-10 pix-opacity-4 pix-hover-opacity-4\" alt=\"Hulp nodig bij uw microfluïdica-project?\"><a href=\"https://darwin-microfluidics.com/nl/contact\" class=\"card-img-overlay2 d-inline-block w-100 pix-img-overlay pix-p-20 d-flex align-items-end\" style=\"min-height:300px;\"><div class=\"w-100\"><div class=\"\"><span class=\"pix-badge-element d-inline-block mr-1 \"><span class=\"badge font-weight-bold bg-primary  \" style=\"font-size:22px; \"><span class=\"text-white\" style=\"\">Neem contact op met onze experts!</span></span></span></div><h2 class=\"card-title font-weight-bold text-white pix-my-10\" style=\"\">Hulp nodig bij uw microfluïdica-project?</h2><span class=\"d-flex align-items-center font-weight-bold text-light-opacity-6 text-20\"><span>Wij maken microfluïdica voor u heel eenvoudig!</span><i class=\"pixicon-angle-right pix-hover-right pix-hover-item pix-ml-10 font-weight-bold text-20\"></i></span></div></a></div>\t\t\t\t</div>\n\t\t\t\t</div>\n\t\t\t\t\t</div>\n\t\t</div>\n\t\t\t\t\t</div>\n\t\t</section>\n\t\t\t\t</div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>When selecting tubing for microfluidic applications, chemical resistance is key to maintaining system integrity. Solva is valued for its durability, chemical resistance, and versatility, making it suitable for various applications. However, Solva is not compatible with all chemicals, so understanding…</p>\n","protected":false},"author":4,"featured_media":30628,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_kc_parent_guide":"","_kc_products":"","_kc_type":"","footnotes":""},"categories":[66,28,69],"tags":[],"class_list":["post-30625","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-chemical-compatibility","category-connectors-tubing","category-tubing"],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.9 - https://yoast.com/product/yoast-seo-wordpress/ -->\n<title>Solva – Chemical Resistance Chart</title>\n<meta name=\"description\" content=\"Ontdek de Solva-chemische resistentietabel om een veilig en effectief gebruik van materialen in diverse toepassingen te waarborgen.\">\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\">\n<link rel=\"canonical\" href=\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/\">\n<meta property=\"og:locale\" content=\"en_US\">\n<meta property=\"og:type\" content=\"article\">\n<meta property=\"og:title\" content=\"Solva – Chemical Resistance Chart\">\n<meta property=\"og:description\" content=\"Ontdek de Solva-chemische resistentietabel om een veilig en effectief gebruik van materialen in diverse toepassingen te waarborgen.\">\n<meta property=\"og:url\" content=\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/\">\n<meta property=\"og:site_name\" content=\"Darwin Microfluidics\">\n<meta property=\"article:published_time\" content=\"2024-11-22T16:47:56+00:00\">\n<meta property=\"article:modified_time\" content=\"2026-11-19T14:33:56+00:00\">\n<meta property=\"og:image\" content=\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Solva-Tubing.jpg\">\n\t<meta property=\"og:image:width\" content=\"1920\">\n\t<meta property=\"og:image:height\" content=\"1920\">\n\t<meta property=\"og:image:type\" content=\"image/jpeg\">\n<meta name=\"author\" content=\"Elia Missi\">\n<meta name=\"twitter:card\" content=\"summary_large_image\">\n<meta name=\"twitter:label1\" content=\"Written by\">\n\t<meta name=\"twitter:data1\" content=\"Elia Missi\">\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\">\n\t<meta name=\"twitter:data2\" content=\"2 minutes\">\n<script type=\"application/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https://schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#article\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/\"},\"author\":{\"name\":\"Elia Missi\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\"},\"headline\":\"Solva – Chemical Resistance Chart\",\"datePublished\":\"2024-11-22T16:47:56+00:00\",\"dateModified\":\"2026-11-19T14:33:56+00:00\",\"mainEntityOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/\"},\"wordCount\":201,\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Solva-Tubing.jpg\",\"articleSection\":[\"Chemical compatibility charts\",\"Connectors &amp; tubing\",\"Tubing\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/\",\"url\":\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/\",\"name\":\"Solva – Chemical Resistance Chart\",\"isPartOf\":{\"@id\":\"https://blog.darwin-microfluidics.com/#website\"},\"primaryImageOfPage\":{\"@id\":\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#primaryimage\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#primaryimage\"},\"thumbnailUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Solva-Tubing.jpg\",\"datePublished\":\"2024-11-22T16:47:56+00:00\",\"dateModified\":\"2026-11-19T14:33:56+00:00\",\"description\":\"Ontdek de Solva-chemische resistentietabel om een veilig en effectief gebruik van materialen in diverse toepassingen te waarborgen.\",\"breadcrumb\":{\"@id\":\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#primaryimage\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Solva-Tubing.jpg\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Solva-Tubing.jpg\",\"width\":1920,\"height\":1920,\"caption\":\"Solva Tubing\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https://blog.darwin-microfluidics.com/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Solva – Chemical Resistance Chart\"}]},{\"@type\":\"WebSite\",\"@id\":\"https://blog.darwin-microfluidics.com/#website\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"name\":\"Blog\",\"description\":\"Onze blog\",\"publisher\":{\"@id\":\"https://blog.darwin-microfluidics.com/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https://blog.darwin-microfluidics.com/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https://blog.darwin-microfluidics.com/#organization\",\"name\":\"Darwin Microfluidics\",\"url\":\"https://blog.darwin-microfluidics.com/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\",\"url\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"contentUrl\":\"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png\",\"width\":300,\"height\":90,\"caption\":\"Darwin Microfluidics\"},\"image\":{\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/logo/image/\"},\"sameAs\":[\"https://www.linkedin.com/company/darwin-microfluidics/\",\"https://darwin-microfluidics.com/nl\"]},{\"@type\":\"Person\",\"@id\":\"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5\",\"name\":\"Elia Missi\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"url\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"contentUrl\":\"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g\",\"caption\":\"Elia Missi\"},\"url\":\"https://blog.darwin-microfluidics.com/author/eliamissi/\"}]}</script>\n<!-- / Yoast SEO plugin. -->","yoast_head_json":{"title":"Solva – Chemical Resistance Chart","description":"Ontdek de Solva-chemische resistentietabel om een veilig en effectief gebruik van materialen in diverse toepassingen te waarborgen.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/","og_locale":"en_US","og_type":"article","og_title":"Solva – Chemical Resistance Chart","og_description":"Discover the Solva chemical resistance chart to ensure safe and effective use of materials in various applications.","og_url":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/","og_site_name":"Darwin Microfluidics","article_published_time":"2024-11-22T16:47:56+00:00","article_modified_time":"2026-11-19T14:33:56+00:00","og_image":[{"width":1920,"height":1920,"url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Solva-Tubing.jpg","type":"image/jpeg"}],"author":"Elia Missi","twitter_card":"summary_large_image","twitter_misc":{"Written by":"Elia Missi","Est. reading time":"2 minutes"},"schema":{"@context":"https://schema.org","@graph":[{"@type":"Article","@id":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#article","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/"},"author":{"name":"Elia Missi","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5"},"headline":"Solva – Chemical Resistance Chart","datePublished":"2024-11-22T16:47:56+00:00","dateModified":"2026-11-19T14:33:56+00:00","mainEntityOfPage":{"@id":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/"},"wordCount":201,"publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"image":{"@id":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Solva-Tubing.jpg","articleSection":["Chemical compatibility charts","Connectors &amp; tubing","Tubing"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/","url":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/","name":"Solva – Chemical Resistance Chart","isPartOf":{"@id":"https://blog.darwin-microfluidics.com/#website"},"primaryImageOfPage":{"@id":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#primaryimage"},"image":{"@id":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#primaryimage"},"thumbnailUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Solva-Tubing.jpg","datePublished":"2024-11-22T16:47:56+00:00","dateModified":"2026-11-19T14:33:56+00:00","description":"Ontdek de Solva-chemische resistentietabel om een veilig en effectief gebruik van materialen in diverse toepassingen te waarborgen.","breadcrumb":{"@id":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#primaryimage","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Solva-Tubing.jpg","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Solva-Tubing.jpg","width":1920,"height":1920,"caption":"Solva Tubing"},{"@type":"BreadcrumbList","@id":"https://blog.darwin-microfluidics.com/solva-chemical-resistance-chart/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https://blog.darwin-microfluidics.com/"},{"@type":"ListItem","position":2,"name":"Solva – Chemical Resistance Chart"}]},{"@type":"WebSite","@id":"https://blog.darwin-microfluidics.com/#website","url":"https://blog.darwin-microfluidics.com/","name":"Blog","description":"Onze blog","publisher":{"@id":"https://blog.darwin-microfluidics.com/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https://blog.darwin-microfluidics.com/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https://blog.darwin-microfluidics.com/#organization","name":"Darwin Microfluidics","url":"https://blog.darwin-microfluidics.com/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/","url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","contentUrl":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/02/Darwin-Microfluidics-logo.png","width":300,"height":90,"caption":"Darwin Microfluidics"},"image":{"@id":"https://blog.darwin-microfluidics.com/#/schema/logo/image/"},"sameAs":["https://www.linkedin.com/company/darwin-microfluidics/","https://darwin-microfluidics.com"]},{"@type":"Person","@id":"https://blog.darwin-microfluidics.com/#/schema/person/c80a1276036340d7e994346f251af8f5","name":"Elia Missi","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","url":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","contentUrl":"https://secure.gravatar.com/avatar/aaae1cf6fd60bdd2785e730c1eef40d923b09eadd04f575148e3be51d2e1c35a?s=96&d=mm&r=g","caption":"Elia Missi"},"url":"https://blog.darwin-microfluidics.com/author/eliamissi/"}]}},"jetpack_featured_media_url":"https://blog.darwin-microfluidics.com/wp-content/uploads/2024/11/Solva-Tubing.jpg","_links":{"self":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30625","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts"}],"about":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/types/post"}],"author":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/users/4"}],"replies":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/comments?post=30625"}],"version-history":[{"count":23,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30625/revisions"}],"predecessor-version":[{"id":30654,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/posts/30625/revisions/30654"}],"wp:featuredmedia":[{"embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media/30628"}],"wp:attachment":[{"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/media?parent=30625"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/categories?post=30625"},{"taxonomy":"post_tag","embeddable":true,"href":"https://blog.darwin-microfluidics.com/wp-json/wp/v2/tags?post=30625"}],"curies":[{"name":"wp","href":"https://api.w.org/{rel}","templated":true}]}}