Start here if you are new to microfluidics: the physics of flow, chips and materials, bubbles, dead volume, cleaning and measurement.
Start hereThe Theory Behind Flow Rate, Pressure, and Resistance in MicrofluidicsIf you’re new to microfluidics, you might be wondering how flow rate, pressure, and resistance are related. We’ll explain the theory !VRBy Vincent RocherRead the articleYour microfluidics basics expert
VRVincent RocherCEO of Darwin Microfluidics
A question about your setup? Ask the person who wrote these guides.
Ask a questionFollow the path
From the basics to a working setup: every step has its guide.
- 1Learn the physicsThe Theory Behind Flow Rate, Pressure, and Resistance in MicrofluidicsInternal volume, swept volume, dead volume in microfluidics
- 2Choose a chipMicrofluidic chips: a quick overviewWhy Is PDMS So Common and Effective in Microfluidics?
- 3Avoid bubblesHow Are Air Bubbles Formed in Microfluidics ?How Does a Bubble Trap Work in Microfluidics?
- 4Clean & measureHow to Clean Your Microfluidic Chip: A Comprehensive GuideThe concept of “true” value
Panoramiche
Understand the techniques and the materials.
OverviewHow Does an Analytical Balance Work ?Discover the precision and functionality behind analytical balances in this insightful article.OverviewProperties of ChipShop Chip MaterialsWe summarize here the main properties of these materials so you can make the right choice for your application.OverviewThe concept of “true” valueThis review explores the notion of 'true value' and the different principles established to measure it. Particularly in microfluidics.OverviewMicrofluidic chips: a quick overviewWhat is a microfluidic chip? Microfluidic chips are used to control and confine fluids at the micro scale. Learn more…OverviewInternal volume, swept volume, dead volume in microfluidicsThe objective of microfluidics is to miniaturize as much as possible. We will define the different volumes encountered in microfluidics.OverviewShear stress in microfluidic devicesShear stress is a critical parameter to consider when designing an experiment and microfluidic chip. There are different techniques that…
Guide e tutorial
Step-by-step protocols for your clean room or lab bench.
GuideHow to Calibrate an Analytical Balance?Discover the step-by-step process to accurately calibrate an analytical balance, ensuring precision in your laboratory measurements.GuideHow to Level an Analytical Balance?Discover the essential steps to accurately level an analytical balance, ensuring precise measurements in your laboratory experiments.GuideHow to Clean an Analytical Balance?Discover the essential steps and expert tips for maintaining precision in your lab work with our comprehensive guide on cleaning…GuideHow to Tare an Analytical Balance?Discover the step-by-step process of taring an analytical balance to ensure precise measurements in your laboratory experiments.GuideHow Does a Bubble Trap Work in Microfluidics?Discover the fascinating world of microfluidics and learn how a bubble trap effectively removes air bubbles from fluid channels.GuideWhy Using a Bubble Trap in Microfluidics?Discover the crucial role of bubble traps in microfluidics and why they are essential for maintaining the integrity of your…GuideHow Are Air Bubbles Formed in Microfluidics ?Discover the causes and sources of air bubbles in microfluidic systems. Understand how these bubbles form.GuideHow to Clean Your Microfluidic Chip: A Comprehensive GuideIt is possible to reuse a microfluidic chip several times. However, you must clean your chip properly after each use!…GuideHow to avoid air bubbles in a microfluidic device?The formation of air bubbles in microfluidics is very common and can in the worst case totally ruin an experience.
Tools & charts
Calculators, converters and compatibility charts.
ToolTopas – COC – Chemical Resistance ChartExplore the chemical resistance of Topas COC with our comprehensive chart to ensure optimal performance in various applications.ToolPC (Polycarbonate) – Chemical Resistance ChartExplore the chemical resistance of Polycarbonate with various substances in our detailed chart for safe material selection.ToolPS (Polystyrene) – Chemical Resistance ChartExplore the chemical resistance of Polystyrene with various substances in our detailed chart for safe material selection.ToolPMMA (Polymethyl Methacrylate) – Chemical Resistance ChartExplore the chemical resistance of PMMA with various substances in our detailed chart for safe material selection.ToolVolume Conversion ToolUse this calculator to quickly switch between different volume units! In microfluidics, a wide range of units is used to…
Confronto e guide all'acquisto
Choose between materials, pumps and chips.
Microfluidics basics supplies
The materials used in these guides, ready to order.
!