The CO2 SensorPlug has been specifically designed for non-invasive measurement of partial pressure of carbon dioxide in liquids, in millifluidic and microfluidic applications. With a Mini Luer interface, it can be easily integrated into microfluidic chips for online monitoring of CO2. These sensors are sold in packs of 10 units.
General
In the SensorPlug, the optical carbon dioxide sensor is attached to a Mini Luer plug, for easy integration in microfluidic chips via the corresponding Mini Luer port. This allows for non-invasive measurement of partial pressure of levels CO2 in liquids in millifluidic and microfluidic experiments, without any risk of contamination.
SensorPlugs are delivered beta-irradiated and pre-calibrated for immediate use. The CO2 SensorPlug can be combined with pH and O2 SensorPlugs and measurements can be controlled from one computer via the PreSens Measurement Studio 2 software.
The SensorPlugs can be integrated into fiber sensor integration chips and multi-organ platforms from ChipShop.
The complete setup for PreSens technology includes a meter, a sensor, and relevant accessories including the optic fiber. These components can easily be integrated to any microfluidics and organ-on-chip experiments.
Optical sensors offer several advantages that render them particularly well-suited for controlling small sample volumes:
- They are small
- The signal does not depend on the flow rate of the sample
- They allow for non-invasive measurement
Content
10x Optical CO2 SensorPlugs
Specifications
Measurement range |
1 - 25% CO2 at atmospheric pressure (1013 hPa) 10 - 250 hPa pCO2 8 - 180 mmHg pCO2 |
Resolution at + 20°C |
± 0.06% CO2 at 2% CO2 ± 0.15% CO2at 6% CO2 ± 0.5 mmHg at 15 mm Hg pCO2 ± 1.2 mmHg at 45 mm Hg pCO2 |
Accuracy | ± 5% of reading or 0.2% (1.5 mmHg); whichever is higher |
Measurement temperature range | From + 15 °C to + 45 °C |
Response time (t90) | < 3 min. for change from 2% to 5% (15 mmHg - 38 mmHg) pCO2 |
Compatible CO2 meters | CO2-1 SMA with SMA-ST-Adapter |
Compatibility | Aqueous solutions, pH 4-9 |
Cross-sensitivity | Optical pCO2 sensors display reduced cross-sensitivity to ionic strength (salinity); acetic acid; SO2; HCl vapors |
Calibration | Pre-calibrated, re-calibration is possible |
Storage stability | 12 months provided the sensor material is stored in the dark |
Plug type | Male Mini Luer fluid connector or customized format on request |
Documentation
The CO2 SensorPlug has been specifically designed for non-invasive measurement of partial pressure of carbon dioxide in liquids, in millifluidic and microfluidic applications. With a Mini Luer interface, it can be easily integrated into microfluidic chips for online monitoring of CO2. These sensors are sold in packs of 10 units.
General
In the SensorPlug, the optical carbon dioxide sensor is attached to a Mini Luer plug, for easy integration in microfluidic chips via the corresponding Mini Luer port. This allows for non-invasive measurement of partial pressure of levels CO2 in liquids in millifluidic and microfluidic experiments, without any risk of contamination.
SensorPlugs are delivered beta-irradiated and pre-calibrated for immediate use. The CO2 SensorPlug can be combined with pH and O2 SensorPlugs and measurements can be controlled from one computer via the PreSens Measurement Studio 2 software.
The SensorPlugs can be integrated into fiber sensor integration chips and multi-organ platforms from ChipShop.
The complete setup for PreSens technology includes a meter, a sensor, and relevant accessories including the optic fiber. These components can easily be integrated to any microfluidics and organ-on-chip experiments.
Optical sensors offer several advantages that render them particularly well-suited for controlling small sample volumes:
- They are small
- The signal does not depend on the flow rate of the sample
- They allow for non-invasive measurement
Content
10x Optical CO2 SensorPlugs
Specifications
Measurement range |
1 - 25% CO2 at atmospheric pressure (1013 hPa) 10 - 250 hPa pCO2 8 - 180 mmHg pCO2 |
Resolution at + 20°C |
± 0.06% CO2 at 2% CO2 ± 0.15% CO2at 6% CO2 ± 0.5 mmHg at 15 mm Hg pCO2 ± 1.2 mmHg at 45 mm Hg pCO2 |
Accuracy | ± 5% of reading or 0.2% (1.5 mmHg); whichever is higher |
Measurement temperature range | From + 15 °C to + 45 °C |
Response time (t90) | < 3 min. for change from 2% to 5% (15 mmHg - 38 mmHg) pCO2 |
Compatible CO2 meters | CO2-1 SMA with SMA-ST-Adapter |
Compatibility | Aqueous solutions, pH 4-9 |
Cross-sensitivity | Optical pCO2 sensors display reduced cross-sensitivity to ionic strength (salinity); acetic acid; SO2; HCl vapors |
Calibration | Pre-calibrated, re-calibration is possible |
Storage stability | 12 months provided the sensor material is stored in the dark |
Plug type | Male Mini Luer fluid connector or customized format on request |