NE-1060 SyringeONE:173 High Flow Rate Programmable Syringe Pump

The NE-1060 SyringeONE:173 from New Era is a single-channel programmable syringe pump for high flow rates. In this version, the SyringeONE:173 can generate flow rates up to 960.5 mL/min.
The SyringeONE:173 pump is fully programmable standalone or through a computer.
Product SKU:
Outstanding Support

Support by a team of engineers & PhDs

Worldwide Express Shipping

Worldwide Express Shipping (delivery in 1-3 days for products in stock)

Money-Back Guarantee

Simplified Purchasing pay by invoice or credit card

1,465.70€
Ask an expert
Adding to cart… The item has been added

Complete Your Setup

Use the checkboxes to select the products you need.

Choose Options
Choose Options Close Close

New Era

Decrease Quantity of undefined
Increase Quantity of undefined
General

The SyringeONE:173 syringe pump holds 1 syringe up to 60 mL (or a 140 mL syringe filled up to 120 mL), and delivers flow rates up to 960.5 mL/min. Built for automation, it contains numerous preset protocols, from simple infusion and dispensing to complex experiments. You can program up to 41 different steps:

  • Change infusion/withdrawal rate
  • Set dispensing volumes
  • Insert pauses
  • Control and respond to external signals through RS-232 and TTL logic control interfaces

The pump works standalone or can be programmed through a computer using the SyringPumpPro software. You can even daisy-chain up to 100 pumps via RS-232 and control them through a computer!

The main specifications for this version of the pump are:

  • From 166.2 nL/min (with a 1 mL syringe) up to 960.5 mL/min (with a 60 mL syringe), higher flow rates can be achieved with a 140 mL syringe.
  • Accuracy of +/- 1%.
Syringe size Min. flow rate Max. flow rate
0.5 µL 0.083 nL/min 14.41 µL/min
1 mL 166.2 nL/min 29.9 mL/min
3 mL 555.2 nL/min 100.1 mL/min
5 mL 1.08 µL/min 195.3 mL/min
10 mL 1.57 µL/min 282.8 mL/min
20 mL 2.73 µL/min 493 mL/min
30 mL 3.51 µL/min 633.2 mL/min
60 mL 5.33 µL/min 960.5 mL/min
140 mL 10.88 µL/min 1961 mL/min

In withdrawal mode, certain glass syringe barrel plungers may not be securely held by the pump's standard pusher block. For 50 and 100 mL glass syringes, the use of the New Era Pusher Block for 50 & 100 mL Glass Syringes is required.

Content

1x NE-1060 (SyringeONE:173) syringe pump

1x Local power supply (24 VDC / 1 A)

1x Operating guide

Specifications
Syringe compatibility

Holds 1 syringe from 0.5 µL up to 60 mL (140 mL partially filled)

Syringe inner diameter range: 0.100 to 50.00 mm

Flow range 166.2 nL/min (1 mL syringe) to 960.5 mL/min (60 mL syringe)
Speed range 0.05755463 cm/h to 173.0477419 cm/min
Max. force

6.8 kg (15 lbs) at minimum speed

2.3 kg (5 lbs) at maximum speed

Pump modes

Infusion and withdrawal

Dispense a set volume

Syringe purge mode will infuse or refill syringe at top speed to purge air from the line or to fill the syringe

Power failure mode restores all parameters on power up, even in case of a power failure while pumping

Pumping rate and direction can be changed while pumping

Stall detection stops the pump when the motor's operation is impeded

Programmability

One-click program upload from the Pumping Program Generator spreadsheet

Pre-program a set of production dispensing protocols. The operator then selects the required dispense protocol from the interface.

Interface

Keypad with optional beeping whenever the keypad is pressed

Keypad Lockout: Prevent unauthorized or accidental changes to the settings by requiring a Lockout Disable key to be inserted to change settings.

RS-232 connector for external control or pump daisy-chaining

TTL I/O logic control

Alarm

Audible buzzer can be programmed to alert when an alarm condition occurs or the pumping program completes

Selectable units

mL/h, µL/h, mL/min, µL/min

Dimensions 22.9 x 14.6 x 11.4 cm
Power supply 24 VDC / 1 A
Weight 1.63 kg (3.6 lbs)
Certification CE certified
Warranty 2 years

 

Pump programming

General

  • One-click program upload from "Pumping Program Generator" spreadsheet
  • Program up to 340 phases
  • Data entry from keypad or computer
  • Pumping programs can be uploaded/downloaded to/from the computer
  • Pre-programmable dispensing volumes (each volume can be different)
  • Pumping rates and direction are automatically changeable
  • Time delays between dispenses can be set
  • Automatically pause the program and wait for the user to continue the dispense
  • The pump rate can be synchronized with other instruments (pumps, sensors, etc...)
  • Send logic signals to other equipment. Change pumping rates in reaction to a sensor
  • Program the audible alarm to beep at any time to alert the operator

Bi-directional RS-232 interface

  • Network up to 100 pumps from a single communications port on a computer. Baud rates up to 19200.
  • Free terminal emulator program allows communications with the syringe pump.
  • Directly control one or more pumps from a computer, including setting the pumping rate, direction, and volume. Set the operational and setup configurations. Also, the TTL interface can be queried and the programmable output set.
  • Each pump in the network can be individually controlled and monitored using a computer. Or, the computer can download a new pumping program to each pump which would automatically reconfigure the dispensing system for a new job.
  • Downloading control programs to the pump would unload the computer overhead to the pump. Computer resources could then be used elsewhere while the pumps operate independently.
  • 2 modes of communication: Basic and Safe
    • Basic: Basic master-slave interface. Easy to implement. Can communicate from any terminal emulator.
    • Safe: A reliable interface for a real-world environment.
  • High-quality interface which detects communication errors via a 16-bit CCITT CRC.
  • The pump will automatically transmit an alarm packet when a pump alarm occurs. For instance, if the pump stalls or resets, a message is immediately sent to the computer.
  • A configurable communications time-out will stop the pump and alarm if the communications link is broken.
  • Packet inter-character time-out to recover packet synchronization after communication glitches.
  • Software Developer friendly communications protocol.
  • Consistent and well-defined communications packets.
  • Constant start and end characters.
  • Packets structured to be easily parsed

TTL Logic Contol Interface

  • Control the pump from a foot switch or timer.
  • Output signals can be used to switch a valve from an output to an input reservoir.
  • Keypad Lockout: Prevent unauthorized or accidental changes to the settings by requiring a "Lockout Disable" key to be inserted to change settings.
  • Pumping direction control
  • Programmable output signal
  • Programmable responses to input signals
  • Configurable start and stop trigger:
    • Start or stop the pump on each contact closure to ground. For example, a foot switch.
    • Start the pump on closure to ground and stop the pump on opening the connection. For example, a timer relay that starts the pump whenever closed and stops the pump whenever open.
    • Only start the pump on each contact closure to ground. For example, a laboratory animal trained to press a lever can receive a drug dosage from the pump and the pump will not stop or deliver another dosage until it is permitted by the pumping program entered by the user
  • Configurable trigger input:
    • Edge trigger: Starts or stops the pump, such as from a foot switch
    • Level trigger: Start or stops the pump, such as from a timer or relay control
    • Start only trigger: Edge trigger will only start the pump, such as from a lab animal trained to press a lever to receive a dosage.

Your Question Answered

View All

Darwin Microfluidics being based in France, ships orders under Delivered At Place (DAP) incoterms. This means that for customers outside the European Union (EU), you are responsible for any applicable customs fees, duties, and taxes in addition to the shipping costs. These charges are determined by your local customs authority and must be paid by you upon the arrival of the shipment in your country.

We recommend contacting your local customs office for detailed information on these charges if you're ordering from outside the EU, as they can vary depending on the destination and the value of your order. Please note that these additional costs are not included in the shipping fees charged by Darwin Microfluidics.

If you've received your order from Darwin Microfluidics and found that a product is defective or missing, please follow these steps to resolve the issue:

Report immediately: Contact our customer service team as soon as possible. Reporting the issue promptly helps us address your concern more efficiently.

Provide details: When you contact us, please provide your order number, the name the order was placed under, and a detailed description of the issue. For defective products, include clear photos or a video that shows the defect.

Review: Our team will review your claim to determine the best course of action. We may ask for additional information or details about the problem.

Resolution: Depending on the situation, we may send a replacement for the defective or missing item, provide a refund, or offer another satisfactory resolution. Our goal is to ensure you are completely satisfied with your purchase.

Follow-up: We will keep you updated throughout the process and confirm when the issue has been resolved to your satisfaction.

We apologize for any inconvenience caused by a defective or missing item and are committed to resolving your issue as quickly and smoothly as possible.

At Darwin Microfluidics, our goal is to offer the most competitive prices directly as our list price, ensuring that all our customers receive great value without needing to navigate complex discount structures. Here’s a detailed look at our discount policy:

Competitive list prices: We work hard to ensure our list prices are among the most competitive in the market. This approach allows us to offer fair pricing to all our customers from the start, eliminating the need for frequent discounts.

Quantity-based discounts: For certain products, we offer quantity-based discounts directly on the product pages. These discounts are automatically applied based on the quantity of the product you purchase, providing savings for bulk purchases without the need for special codes or negotiations.

Bulk orders: While we strive to offer the best prices upfront, we understand that customers making large-scale purchases may have special considerations. In such cases, we invite you to discuss your needs with our sales team. Depending on the size and nature of your order, we may be able to offer tailored discounts or pricing adjustments.

We believe in transparency and simplicity in pricing, allowing you to make your purchases with confidence, knowing you're receiving a fair deal without the hassle of negotiating discounts. If you have any questions about pricing or discounts for bulk orders, please don't hesitate to reach out to our sales team for personalized assistance.

Please follow our returns & refund page.

Since Darwin Microfluidics sells exclusively to companies and institutions and is based in France, the VAT treatment for your orders depends on the location of your company or institution:

Within the EU (excluding France): For customers in other EU countries, the reverse charge mechanism applies. This means that VAT is not charged by us at the point of sale. Instead, it is your responsibility to account for the VAT at the standard rate applicable in your country under the reverse charge procedure. This process helps simplify cross-border transactions within the EU.

In France: For customers located in France, standard French VAT rates apply to all purchases. As a France-based company, we are required to charge VAT on sales to other French companies and institutions, which you can then reclaim according to local VAT procedures if applicable.

Outside the EU: For customers outside the European Union, sales are not subject to VAT by us. However, you may be subject to import duties, taxes, and charges that are not included in the item price or shipping cost. These charges are the buyer's responsibility and vary by country. We advise checking with your local customs office for more information.

Please ensure your VAT identification number is provided during the ordering process for EU transactions to qualify for the reverse charge mechanism. If you have any questions regarding VAT charges or need further assistance with VAT-related issues, please contact our customer service team.

We are unable to provide specific estimates for customs fees, duties, or taxes associated with your order. These charges are determined by the customs authority in your country and can vary based on a variety of factors, including the type of items purchased, their value, and the country to which they are being shipped.

We recommend contacting your local customs office directly to get the most accurate and up-to-date information regarding potential customs charges for your order. They can provide you with detailed guidelines on the fees you might expect to pay based on the products you're importing from us.

Please remember, these charges are the responsibility of the recipient and are not included in the shipping costs paid to Darwin Microfluidics.

See All Availability

Use the filter to narrow your search

Power supply
  • Clear

4 options for this product

NE-1060 SyringeONE:173 High Flow Rate Programmable Syringe Pump
NE-1060 SyringeONE:173 High Flow Rate Programmable Syringe Pump
SKU: NE-1060-EP
European
1,465.70€
Login to request a quote
Available immediately
Out of stock
NE-1060 SyringeONE:173 High Flow Rate Programmable Syringe Pump
NE-1060 SyringeONE:173 High Flow Rate Programmable Syringe Pump
SKU: NE-1060-UP
US
1,465.70€
Login to request a quote
Available immediately
Out of stock
NE-1060 SyringeONE:173 High Flow Rate Programmable Syringe Pump
NE-1060 SyringeONE:173 High Flow Rate Programmable Syringe Pump
SKU: NE-1060-BP
British
1,465.70€
Login to request a quote
Available immediately
Out of stock
NE-1060 SyringeONE:173 High Flow Rate Programmable Syringe Pump
NE-1060 SyringeONE:173 High Flow Rate Programmable Syringe Pump
SKU: NE-1060-AP
Australian
1,465.70€
Login to request a quote
Available immediately
Out of stock
Send Request Background
Contact us - product page

Got A Question?

Got a question or need a custom microfluidic solution? Our experts are here to help! Whether you're looking for prototyping, design consultation, or bulk manufacturing, we provide tailored solutions to fit your needs.

Send Request

You Might Also Like

View All
SyringeONE Programmable Syringe Pump - Darwin Microfluidics
Choose Options

New Era

NE-1000 SyringeONE Programmable Syringe Pump
The NE-1000 New Era SyringeOne is a single-channel programmable syringe pump for a wide range of applications: in its standard version, the SyringeONE can generate flow rates typically between 12.12...
884.90€
email subscription background

Get the latest updates on new products and upcoming sales

Review Your Cart Close Close
Your cart is empty Your cart is empty Your cart is empty
Menu Close Close
Search Close Close

  • EXTENDO 944X

    EXTENDO 944X Featuring several next gen optimizations, the Extendo 944X telehandler is powered by a standard

  • EXTENDO 944X

    EXTENDO 944X Featuring several next gen optimizations, the Extendo 944X telehandler is powered by a standard

  • EXTENDO 944X

    EXTENDO 944X Featuring several next gen optimizations, the Extendo 944X telehandler is powered by a standard