The Harvard Apparatus PHD ULTRA OEM syringe pump is the solution for your most demanding applications. The Harvard Apparatus PHD ULTRA OEM syringe pump have superior mechanical drive mechanisms and syringe holding mechanics to achieve the highest performance of any syringe pump. Covering a flow range from 1.56 pL/min up to 216 mL/min with unrivaled accuracy, the OEM series is compact, easy to integrate into your microfluidic setup, and holds syringes ranging from 0.5 µL to 200 mL.
The pump is available in four configurations: standard, push/pull, high pressure, and ultra-high pressure.
General
Without its built-in user interface, Harvard Apparatus PHD ULTRA OEM syringe pump provides the same performance as its standalone equivalent, with a smaller footprint. Smooth flow rates from 1.56 pL/min to 216 mL/min are delivered with an unrivaled accuracy (down to 0.25%). The superior mechanical drive and syringe holding mechanism ensure the highest performance.
- Infusion and withdrawal
- Small footprint: 29.8 x 14 x 16.5 cm (11.75 x 5.5 x 6.5 in)
- Holds plastic, glass, or stainless steel syringe
- Fully programmable from the FlowControl software (in option) or with command lines
- Advanced connectivity: RS-232 and USB serial inputs, RS-485 or TTL interfaces
- 2-year warranty
Four types of Harvard Apparatus PHD ULTRA OEM syringe pumps have been developed to meet every requirement:
PHD ULTRA Standard | PHD ULTRA Push/Pull | PHD ULTRA 4400 | PHD ULTRA XF | |
Application | Low-pressure, microfluidics | For continuous flow applications (cell culture, etc.) | High pressure with stainless steel syringes | Ultra-high pressure |
Pump function | Infuse/Withdraw | Push/Pull | Infuse/Withdraw | Infuse/Withdraw |
Number of channels | 2 | 4 | 1 | 4 |
Syringe size |
0.5 μL up to 140 mL |
0.5 μL up to 140 mL |
0.5 μL up to 140 mL |
20 mL up to 200 mL |
Flow range | 1.56 pL/min up to 216 mL/min | 1.56 pL/min up to 216 mL/min | 1.56 pL/min up to 216 mL/min | 50.7 nL/min up to 144.08 mL/min |
Accuracy | ±0.25% | ±0.25% | ±0.35% | ±0.5% |
Max. linear force | 34 kg (75 lb) @ 100% Force Selection | 34 kg (75 lb) @ 100% Force Selection | 90.7 kg (200 lb) @ 100% Force Selection | 453.6 kg (1000 lb) @ 100% Force Selection |
Harvard Apparatus has developed LabVIEW drivers for their pumps, and each pump module can be controlled by ASCII command lines. RS-485 in and out connection ports allow daisy-chaining several pumps, making it easy to control all the pumps from a single USB connection to your computer.
Content
1x Harvard Apparatus PHD ULTRA OEM syringe pump
1x Power supply
Specifications
PHD ULTRA Standard | PHD ULTRA Push/Pull | PHD ULTRA 4400 | PHD ULTRA XF | |
Type |
Microprocessor multiple syringes, infusion/withdrawal programmable |
Microprocessor four syringe, push/pull infusion/withdrawal |
Microprocessor single syringe infusion/withdrawal programmable |
Microprocessor multiple syringe, infusion/withdrawal programmable |
Accuracy |
±0.25% |
±0.25% |
±0.35% |
±0.5% |
Syringe |
|
|
|
|
Flow Rate | 1.56 pL/min up to 216 mL/min | 1.56 pL/min up to 216 mL/min | 1.56 pL/min up to 216 mL/min | 50.7 nL/min up to 144.08 mL/min |
Temperature and humidity |
4 °C to 40 °C 20% to 80% RH, non condensing |
4 °C to 40 °C 20% to 80% RH, non condensing |
4 °C to 40 °C 20% to 80% RH, non condensing |
4 °C to 40 °C 20% to 80% RH, non condensing |
Connectors |
|
|
|
|
Drive Motor |
0.9° Stepper Motor |
0.9° Stepper Motor | 1.8° Stepper Motor | 1.8° Stepper Motor |
Motor Drive Control |
Microprocessor with 1/16 microstepping
|
Microprocessor with 1/16 microstepping
|
Microprocessor with 1/16 microstepping
|
Microprocessor with 1/16 microstepping
|
Number of Microsteps per one rev of Lead Screw |
12800 |
12800 | 6400 | 12800 |
Average Linear Force | 34 kg (75 lb) @ 100% Force Selection | 34 kg (75 lb) @ 100% Force Selection | 90.7 kg (200 lb) @ 100% Force Selection | 453.6 kg (1000 lb) @ 100% Force Selection |
Input Power | 50 W, 0.5 A fuse | 50 W, 0.5 A fuse | 50 W, 0.5 A fuse | 50 W, 0.5 A fuse |
Power Supply | 100-240 VAC, 50/60 Hz | 100-240 VAC, 50/60 Hz | 100-240 VAC, 50/60 Hz | 100-240 VAC, 50/60 Hz |
Dimensions (H x W x D) |
29.8 x 14 x 16.75 cm (11.75 x 5.5 x 6.5 in) |
29.8 x 14 x 16.75 cm (11.75 x 5.5 x 6.5 in) | 29.8 x 14 x 16.75 cm (11.75 x 5.5 x 6.5 in) | 29.8 x 14 x 16.75 cm (11.75 x 5.5 x 6.5 in) |
Weight | 4.5 kg (10 lb) | 5.1 kg (11.2 lb) | 5.3 kg (11.7 lb) | 4.5 kg (10 lb) |
Regulatory Certifications | CE, UL, CSA, CB Scheme, EU RoHS | CE, UL, CSA, CB Scheme, EU RoHS | CE, UL, CSA, CB Scheme, EU RoHS | CE, UL, CSA, CB Scheme, EU RoHS |
Documentation
The Harvard Apparatus PHD ULTRA OEM syringe pump is the solution for your most demanding applications. The Harvard Apparatus PHD ULTRA OEM syringe pump have superior mechanical drive mechanisms and syringe holding mechanics to achieve the highest performance of any syringe pump. Covering a flow range from 1.56 pL/min up to 216 mL/min with unrivaled accuracy, the OEM series is compact, easy to integrate into your microfluidic setup, and holds syringes ranging from 0.5 µL to 200 mL.
The pump is available in four configurations: standard, push/pull, high pressure, and ultra-high pressure.
General
Without its built-in user interface, Harvard Apparatus PHD ULTRA OEM syringe pump provides the same performance as its standalone equivalent, with a smaller footprint. Smooth flow rates from 1.56 pL/min to 216 mL/min are delivered with an unrivaled accuracy (down to 0.25%). The superior mechanical drive and syringe holding mechanism ensure the highest performance.
- Infusion and withdrawal
- Small footprint: 29.8 x 14 x 16.5 cm (11.75 x 5.5 x 6.5 in)
- Holds plastic, glass, or stainless steel syringe
- Fully programmable from the FlowControl software (in option) or with command lines
- Advanced connectivity: RS-232 and USB serial inputs, RS-485 or TTL interfaces
- 2-year warranty
Four types of Harvard Apparatus PHD ULTRA OEM syringe pumps have been developed to meet every requirement:
PHD ULTRA Standard | PHD ULTRA Push/Pull | PHD ULTRA 4400 | PHD ULTRA XF | |
Application | Low-pressure, microfluidics | For continuous flow applications (cell culture, etc.) | High pressure with stainless steel syringes | Ultra-high pressure |
Pump function | Infuse/Withdraw | Push/Pull | Infuse/Withdraw | Infuse/Withdraw |
Number of channels | 2 | 4 | 1 | 4 |
Syringe size |
0.5 μL up to 140 mL |
0.5 μL up to 140 mL |
0.5 μL up to 140 mL |
20 mL up to 200 mL |
Flow range | 1.56 pL/min up to 216 mL/min | 1.56 pL/min up to 216 mL/min | 1.56 pL/min up to 216 mL/min | 50.7 nL/min up to 144.08 mL/min |
Accuracy | ±0.25% | ±0.25% | ±0.35% | ±0.5% |
Max. linear force | 34 kg (75 lb) @ 100% Force Selection | 34 kg (75 lb) @ 100% Force Selection | 90.7 kg (200 lb) @ 100% Force Selection | 453.6 kg (1000 lb) @ 100% Force Selection |
Harvard Apparatus has developed LabVIEW drivers for their pumps, and each pump module can be controlled by ASCII command lines. RS-485 in and out connection ports allow daisy-chaining several pumps, making it easy to control all the pumps from a single USB connection to your computer.
Content
1x Harvard Apparatus PHD ULTRA OEM syringe pump
1x Power supply
Specifications
PHD ULTRA Standard | PHD ULTRA Push/Pull | PHD ULTRA 4400 | PHD ULTRA XF | |
Type |
Microprocessor multiple syringes, infusion/withdrawal programmable |
Microprocessor four syringe, push/pull infusion/withdrawal |
Microprocessor single syringe infusion/withdrawal programmable |
Microprocessor multiple syringe, infusion/withdrawal programmable |
Accuracy |
±0.25% |
±0.25% |
±0.35% |
±0.5% |
Syringe |
|
|
|
|
Flow Rate | 1.56 pL/min up to 216 mL/min | 1.56 pL/min up to 216 mL/min | 1.56 pL/min up to 216 mL/min | 50.7 nL/min up to 144.08 mL/min |
Temperature and humidity |
4 °C to 40 °C 20% to 80% RH, non condensing |
4 °C to 40 °C 20% to 80% RH, non condensing |
4 °C to 40 °C 20% to 80% RH, non condensing |
4 °C to 40 °C 20% to 80% RH, non condensing |
Connectors |
|
|
|
|
Drive Motor |
0.9° Stepper Motor |
0.9° Stepper Motor | 1.8° Stepper Motor | 1.8° Stepper Motor |
Motor Drive Control |
Microprocessor with 1/16 microstepping
|
Microprocessor with 1/16 microstepping
|
Microprocessor with 1/16 microstepping
|
Microprocessor with 1/16 microstepping
|
Number of Microsteps per one rev of Lead Screw |
12800 |
12800 | 6400 | 12800 |
Average Linear Force | 34 kg (75 lb) @ 100% Force Selection | 34 kg (75 lb) @ 100% Force Selection | 90.7 kg (200 lb) @ 100% Force Selection | 453.6 kg (1000 lb) @ 100% Force Selection |
Input Power | 50 W, 0.5 A fuse | 50 W, 0.5 A fuse | 50 W, 0.5 A fuse | 50 W, 0.5 A fuse |
Power Supply | 100-240 VAC, 50/60 Hz | 100-240 VAC, 50/60 Hz | 100-240 VAC, 50/60 Hz | 100-240 VAC, 50/60 Hz |
Dimensions (H x W x D) |
29.8 x 14 x 16.75 cm (11.75 x 5.5 x 6.5 in) |
29.8 x 14 x 16.75 cm (11.75 x 5.5 x 6.5 in) | 29.8 x 14 x 16.75 cm (11.75 x 5.5 x 6.5 in) | 29.8 x 14 x 16.75 cm (11.75 x 5.5 x 6.5 in) |
Weight | 4.5 kg (10 lb) | 5.1 kg (11.2 lb) | 5.3 kg (11.7 lb) | 4.5 kg (10 lb) |
Regulatory Certifications | CE, UL, CSA, CB Scheme, EU RoHS | CE, UL, CSA, CB Scheme, EU RoHS | CE, UL, CSA, CB Scheme, EU RoHS | CE, UL, CSA, CB Scheme, EU RoHS |