Organ-on-a-Chip - Cross-flow membrane - Luer and Mini Luer

The Fluidic 568 Organ-on-a-Chip by Microfluidic ChipShop is a cost-effective and compact solution for recreating in vitro biological barriers. Each chip features two distinct culture chambers, allowing the co-culture of various cell types in two independent compartments separated by a permeable membrane.
The chip is fabricated in Topas (COC, cyclic olefin copolymer) for better light transmittance. Half of the ports on this chip are integrated with Luer connection ports to interface fluidic reservoirs. The remaining ports are mini Luer interfaces.
Product SKU:
CS-10001200
Outstanding Support

Support by a team of engineers & PhDs

Worldwide Express Shipping

Worldwide Express Shipping (delivery in 1-3 days for products in stock)

Money-Back Guarantee

Simplified Purchasing pay by invoice or credit card

$87.65
Available immediately
Ask an expert
Adding to cart… The item has been added

Complete Your Setup

Use the checkboxes to select the products you need.

microfluidic ChipShop

Decrease Quantity of undefined
Increase Quantity of undefined
General

This Organ-on-a-Chip with a cross-flow membrane allows you to reliably mimic physiological conditions in vitro and study tissue organization, cell-cell interactions, barrier penetration, and physiological responses in a more in vivo-like environment.

Two different and independent culture chambers are available on the same chip. This allows you to perform two experiments in parallel or in series (body-on-a-chip).

The two chambers are designed to develop models of physiological barriers and to ensure an in vivo-like environment under static or dynamic flow conditions. Each chamber indeed has 2 flow inlets and 2 outlets for the perfusion of culture media and testing solutions in both the apical and basolateral compartments.

The entire body of the chip is made of Topas, a cyclic olefin copolymer (COC) to overcome the limitations of standard PDMS. Topas does not unspecifically absorb medium contents and has high stability and ideal optical characteristics for the bright field as well as fluorescence microscopy. Topas is frequently used in medical devices due to its proven biocompatibility.

The chip comes with an 8 µm porous membrane. Each chamber has 2 Luer inlets to interface fluidic reservoirs and 2 mini Luer outlets.

Features

  • Luer and mini Luer connection molded with the chip: leak-free
  • Highly resistant and optically clear material: Topas (COC, cyclic olefin copolymer) has high transparency (equivalent to glass) and very low grade of auto-fluorescence
  • Standard microscope glass slide size (75.5 mm x 25.5 mm x 1.5 mm)
  • Cover lid thickness: 140 µm
  • 2 independent cell culture chambers
  • 8 µm porous PET membrane

 

Cross-flow porous membrane Upper/Apical compartment Bottom/Basolateral compartment

Membrane of the cross-flow membrane organ-on-a-chip

Upper compartment of the cross-flow membrane organ-on-a-chip Bottom compartment of the cross-flow membrane organ-on-a-chip

Applications and examples from published papers

The upper and the lower compartments are separated by the porous membrane, and they can be perfused with different culture media. A tissue interface can be created to mimic alveolar, stomach, intestine, kidney, liver, brain-blood, skin functions, etc. Tissues inside the chip can be easily observed by microscopy.

Cell culture is just one potential application area of this versatile chip. The design indeed allows other different experiments such as small molecule transfer measurements, on-chip dialysis, and many more.

Intestine-on-chip

Maurer M. et al., A three-dimensional immunocompetent intestine-on-chip model as in vitro platform for functional and microbial interaction studies, Biomaterials 2019 (Download)

Intestine-on-chip images from the linked article

3D microphysiological model of the human intestine.

In this work, the model displays the physiological immune tolerance of the intestinal lumen to microbial-associated molecular patterns and can, therefore, be colonized with living microorganisms. The authors demonstrate that microbial interactions can be efficiently investigated using this chip creating a more physiological and immunocompetent microenvironment.

Endothelial Barrier-on-chip

Raasch M. et al., Microfluidically supported biochip design for culture of endothelial cell layers with improved perfusion conditions, Biofabrication 2015, 7: 015013 (Download)

Endothelial cells layers images from the linked article

The authors investigated cell viability, expression of endothelial markers, and cell adhesion molecules of ECs dynamically cultured under low and high shear stress. This chip allows an effective supply with nutrition medium, discharge of catabolic cell metabolites, and defined application of shear stress to ECs under laminar flow conditions.

They show that ECs cultured in the chip form a tight EC monolayer with increased cellular density and enhanced cell layer thickness compared to static and two-dimensionally perfused cell culture conditions. Endothelial layers in the chip express higher amounts of EC marker proteins von-Willebrand-factor and PECAM-1.

Liver-on-chip

Rennert K. et al., A microfluidically perfused three dimensional human liver model, Biomaterials 2015, 119-131 (Download)

Liver-on-chip images from the linked article

The microfluidically perfused chip enables sufficient nutrition supply and resembles morphological aspects of the human liver sinusoid. It utilizes a suspended membrane as a cell substrate mimicking the space of Disse and the perfusion enhances the formation of hepatocyte microvilli. The authors stated that the perfused liver chip shares relevant morphological and functional characteristics with the human liver and represents a new in vitro research tool to study human hepatocellular physiology at the cellular level under conditions close to the physiological situation.

During culture in the biochip HepaRG cells consistently differentiate into cells exhibiting a hepatocyte phenotype and into cells with biliary epithelial cell phenotype that self-organize into a hepatocyte layer with functional bile ducts.

Content

1x Cross-flow membrane organ-on-a-chip with Luer and mini Luer ports

Specifications

Please use this information to precisely define the key parameters of your cell seeding and experimental protocols. One chip allows you to perform two independent experiments.

  Upper compartment Bottom compartment
Volume (µL) 105.8 64
Total surface (mm²) 605 281
Ground surface (mm²) 151 120
Pore size (µm) 8
Lid thickness (µm) 140
  Porous membrane
Area of interaction (mm²) 40.6
Pore size (µm) 8
Membrane reference mcs-membrane 120
Pore density (pores/cm²) 1×10^5 +/- 0.02
Thickness (µm) 11.5 +/- 1.5
Material Hydrophilized polyethylene terephthalate (PET)
Color Transparent
Pore orientation Parallel, perpendicular to the surface
Imaging Yes
Chip material Topas (COC)
Lid thickness (µm) 140

 

Dimensions of the cross-flow membrane organ-on-a-chip with Luer and mini Luer ports

Documentation

Click to read more information about ChipShop chips material properties.

? Organ-on-a-Chip - Cross-flow membrane - Luer and Mini Luer - Fluidic 568 datasheet

? General handling guide for cross-flow membrane chips (available soon)

Maurer, M., Gresnigt, M. S., Last, A., Wollny, T., Berlinghof, F., Pospich, R., ... & Mosig, A. S. (2019). A three-dimensional immunocompetent intestine-on-chip model as in vitro platform for functional and microbial interaction studies. Biomaterials,220, 119396. https://doi.org/10.1016/j.biomaterials.2019.119396

Raasch, M., Rennert, K., Jahn, T., Peters, S., Henkel, T., Huber, O., ... & Mosig, A. (2015). Microfluidically supported biochip design for culture of endothelial cell layers with improved perfusion conditions. Biofabrication, 7(1), 015013. doi:10.1088/1758-5090/7/1/015013

Rennert, K., Steinborn, S., Gröger, M., Ungerböck, B., Jank, A. M., Ehgartner, J., Nietzsche, S., Dinger, J., Kiehntopf, M., Funke, H., Peters, F. T., Lupp, A., Gärtner, C., Mayr, T., Bauer, M., Huber, O., & Mosig, A. S. (2015). A microfluidically perfused three dimensional human liver model. Biomaterials, 71, 119–131. https://doi.org/10.1016/j.biomaterials.2015.08.043

Your Question Answered

View All

Darwin Microfluidics being based in France, ships orders under Delivered At Place (DAP) incoterms. This means that for customers outside the European Union (EU), you are responsible for any applicable customs fees, duties, and taxes in addition to the shipping costs. These charges are determined by your local customs authority and must be paid by you upon the arrival of the shipment in your country.

We recommend contacting your local customs office for detailed information on these charges if you're ordering from outside the EU, as they can vary depending on the destination and the value of your order. Please note that these additional costs are not included in the shipping fees charged by Darwin Microfluidics.

If you've received your order from Darwin Microfluidics and found that a product is defective or missing, please follow these steps to resolve the issue:

Report immediately: Contact our customer service team as soon as possible. Reporting the issue promptly helps us address your concern more efficiently.

Provide details: When you contact us, please provide your order number, the name the order was placed under, and a detailed description of the issue. For defective products, include clear photos or a video that shows the defect.

Review: Our team will review your claim to determine the best course of action. We may ask for additional information or details about the problem.

Resolution: Depending on the situation, we may send a replacement for the defective or missing item, provide a refund, or offer another satisfactory resolution. Our goal is to ensure you are completely satisfied with your purchase.

Follow-up: We will keep you updated throughout the process and confirm when the issue has been resolved to your satisfaction.

We apologize for any inconvenience caused by a defective or missing item and are committed to resolving your issue as quickly and smoothly as possible.

At Darwin Microfluidics, our goal is to offer the most competitive prices directly as our list price, ensuring that all our customers receive great value without needing to navigate complex discount structures. Here’s a detailed look at our discount policy:

Competitive list prices: We work hard to ensure our list prices are among the most competitive in the market. This approach allows us to offer fair pricing to all our customers from the start, eliminating the need for frequent discounts.

Quantity-based discounts: For certain products, we offer quantity-based discounts directly on the product pages. These discounts are automatically applied based on the quantity of the product you purchase, providing savings for bulk purchases without the need for special codes or negotiations.

Bulk orders: While we strive to offer the best prices upfront, we understand that customers making large-scale purchases may have special considerations. In such cases, we invite you to discuss your needs with our sales team. Depending on the size and nature of your order, we may be able to offer tailored discounts or pricing adjustments.

We believe in transparency and simplicity in pricing, allowing you to make your purchases with confidence, knowing you're receiving a fair deal without the hassle of negotiating discounts. If you have any questions about pricing or discounts for bulk orders, please don't hesitate to reach out to our sales team for personalized assistance.

Please follow our returns & refund page.

Since Darwin Microfluidics sells exclusively to companies and institutions and is based in France, the VAT treatment for your orders depends on the location of your company or institution:

Within the EU (excluding France): For customers in other EU countries, the reverse charge mechanism applies. This means that VAT is not charged by us at the point of sale. Instead, it is your responsibility to account for the VAT at the standard rate applicable in your country under the reverse charge procedure. This process helps simplify cross-border transactions within the EU.

In France: For customers located in France, standard French VAT rates apply to all purchases. As a France-based company, we are required to charge VAT on sales to other French companies and institutions, which you can then reclaim according to local VAT procedures if applicable.

Outside the EU: For customers outside the European Union, sales are not subject to VAT by us. However, you may be subject to import duties, taxes, and charges that are not included in the item price or shipping cost. These charges are the buyer's responsibility and vary by country. We advise checking with your local customs office for more information.

Please ensure your VAT identification number is provided during the ordering process for EU transactions to qualify for the reverse charge mechanism. If you have any questions regarding VAT charges or need further assistance with VAT-related issues, please contact our customer service team.

We are unable to provide specific estimates for customs fees, duties, or taxes associated with your order. These charges are determined by the customs authority in your country and can vary based on a variety of factors, including the type of items purchased, their value, and the country to which they are being shipped.

We recommend contacting your local customs office directly to get the most accurate and up-to-date information regarding potential customs charges for your order. They can provide you with detailed guidelines on the fees you might expect to pay based on the products you're importing from us.

Please remember, these charges are the responsibility of the recipient and are not included in the shipping costs paid to Darwin Microfluidics.

Send Request Background
Contact us - product page

Got A Question?

Got a question or need a custom microfluidic solution? Our experts are here to help! Whether you're looking for prototyping, design consultation, or bulk manufacturing, we provide tailored solutions to fit your needs.

Send Request

You Might Also Like

View All
Organ-on-a-Chip - Cross-flow membrane - Mini Luer - Darwin Microfluidics
Choose Options

microfluidic ChipShop

Organ-on-a-Chip - Cross-flow membrane - Mini Luer
The Fluidic 480 Organ-on-a-Chip by Microfluidic ChipShop is an affordable and compact solution for recreating in vitro biological barriers. Each chip features two distinct culture chambers, allowing...
$87.65
Multi-Organ Cross-Flow Membrane Chip - Luer
Add to Cart The item has been added

microfluidic ChipShop

Multi-Organ Cross-Flow Membrane Chip - Luer
The Fluidic 923 chip manufactured by ChipShop is a multi-organ-on-a-chip platform displaying four connected chambers to culture cells and study the interaction between them. The inlets and outlets...
$172.32
email subscription background

Get the latest updates on new products and upcoming sales

Review Your Cart Close Close
Your cart is empty Your cart is empty Your cart is empty
Menu Close Close
Search Close Close

  • EXTENDO 944X

    EXTENDO 944X Featuring several next gen optimizations, the Extendo 944X telehandler is powered by a standard

  • EXTENDO 944X

    EXTENDO 944X Featuring several next gen optimizations, the Extendo 944X telehandler is powered by a standard

  • EXTENDO 944X

    EXTENDO 944X Featuring several next gen optimizations, the Extendo 944X telehandler is powered by a standard