L/S 2-Stop Tygon E-LFL Pump Tubing
A set of 2-stop tubing for Masterflex L/S pump heads. Masterflex Tygon E-LFL has the longest life of all Tygon formulations for peristaltic pumping.
Compatible with any pump heads accepting 2-stop L/S tubing,
General
Masterflex Tygon E-Lab tubing offers the longest pumping life of all Tygon formulations (+1000 hours).
- Pack of 2-stop tubing for L/S pump heads (Multichannel and Multichannel Cartridge), 4 or 8 per pack
- Precisely extruded for high accuracy and repeatability
- Broad chemical resistance
- Clear, easy flow monitoring
- Non-toxic, non-aging, non-oxidizing
- Meets ADCF, EU Food 10/2011, FDA, RoHS, REACH, USP Class VI
- Non-DEHP
- Low gas permeability
Sizes
Choose your tubing size according to your flow rate and peristaltic pump head. See the product pages of Masterflex pump heads for more information.
Precision | High-Performance | |||||
L/S 13 | L/S 14 | L/S 16 | L/S 25 | L/S 24 | L/S 35 | |
Tubing ID (mm) | 0.8 | 1.6 | 3.1 | 4.8 | 6.4 | 7.9 |
Qty per pack | 8 | 8 | 8 | 8 | 4 | 4 |
Content
1x Pack of 2-stop L/S E-LFL tubing (4 or 8/pack)
Specifications
A complete database of the chemical compatibility of Masterflex tubing can be found here.
Precision | High-Performance | |||||
L/S 13 | L/S 14 | L/S 16 | L/S 25 | L/S 24 | L/S 35 | |
Tubing ID (mm) | 0.8 | 1.6 | 3.1 | 4.8 | 6.4 | 7.9 |
Max flow rate (mL/min) | 36 | 130 | 480 | 1000 | 1800 | 2600 |
Max pressure | 2.7 bar (40 psi) | 2.4 bar (35 psi) | 2.7 bar (40 psi) | 2.4 bar (35 psi) | ||
Temperature range | -46 to 74 °C | |||||
Temperature range (dynamic) | 0 to 40 °C | |||||
Max vacuum | 660 mmHg | |||||
Regulatory approvals | ADCF, European Pharmacopoeia, RoHS, REACH, USP Class VI, non-DEHP | |||||
Sterilization methods | EtO | |||||
Suction lift H2O | 8.8 m (29 ft) |
A set of 2-stop tubing for Masterflex L/S pump heads. Masterflex Tygon E-LFL has the longest life of all Tygon formulations for peristaltic pumping.
Compatible with any pump heads accepting 2-stop L/S tubing,
General
Masterflex Tygon E-Lab tubing offers the longest pumping life of all Tygon formulations (+1000 hours).
- Pack of 2-stop tubing for L/S pump heads (Multichannel and Multichannel Cartridge), 4 or 8 per pack
- Precisely extruded for high accuracy and repeatability
- Broad chemical resistance
- Clear, easy flow monitoring
- Non-toxic, non-aging, non-oxidizing
- Meets ADCF, EU Food 10/2011, FDA, RoHS, REACH, USP Class VI
- Non-DEHP
- Low gas permeability
Sizes
Choose your tubing size according to your flow rate and peristaltic pump head. See the product pages of Masterflex pump heads for more information.
Precision | High-Performance | |||||
L/S 13 | L/S 14 | L/S 16 | L/S 25 | L/S 24 | L/S 35 | |
Tubing ID (mm) | 0.8 | 1.6 | 3.1 | 4.8 | 6.4 | 7.9 |
Qty per pack | 8 | 8 | 8 | 8 | 4 | 4 |
Content
1x Pack of 2-stop L/S E-LFL tubing (4 or 8/pack)
Specifications
A complete database of the chemical compatibility of Masterflex tubing can be found here.
Precision | High-Performance | |||||
L/S 13 | L/S 14 | L/S 16 | L/S 25 | L/S 24 | L/S 35 | |
Tubing ID (mm) | 0.8 | 1.6 | 3.1 | 4.8 | 6.4 | 7.9 |
Max flow rate (mL/min) | 36 | 130 | 480 | 1000 | 1800 | 2600 |
Max pressure | 2.7 bar (40 psi) | 2.4 bar (35 psi) | 2.7 bar (40 psi) | 2.4 bar (35 psi) | ||
Temperature range | -46 to 74 °C | |||||
Temperature range (dynamic) | 0 to 40 °C | |||||
Max vacuum | 660 mmHg | |||||
Regulatory approvals | ADCF, European Pharmacopoeia, RoHS, REACH, USP Class VI, non-DEHP | |||||
Sterilization methods | EtO | |||||