The upgrade of the standard Cartridge pump head is designed for high-precision synchronous multichannel pumping up to 12 channels. Compatible with most L/S drives.
It delivers a flow rate from 0.00005 to 350 mL/min depending on the head type and tubing size.
General
Masterflex L/S Reduced-Pulsation Cartridge pump head
The Reduced-Pulsation Cartridge pump head offers synchronous multichannel pumping over a wide range of flow rates.
- Precision molded housing
- Fast tubing changes: cartridge snap in and out easily
- 6 or 8 rollers for reduced pulsation and lower flow rates
- 1 up to 12 cartridges: 6-roller version accepts 2 or 6 large cartridges, 8-roller version accepts 4 or 12 small cartridges
- From 0.00005 to 350 mL/min and up to 600 rpm depending on the pump drive
- Adjustable occlusion optimized for each tubing size
- Compatible with 2-stop microbore or Masterflex L/S tubing
Tip: to further reduce the pulsation, cartridges can be mounted in opposite directions to balance their offset occlusion. Just connect the two tubes with a Y-connector to get the resulting flow.
Cartridge
Manufactured in polycarbonate and glass-filled nylon, the cartridges do not need any tool to be loaded on the pump head. Their occlusion “wedge” design provides accurate and more balanced flow control.
The 6-roller pump head supports 2 or 6 large cartridges, while the 8-roller pump head supports 4 or 12 small cartridges.
Compatibility:
- Small cartridge: all 2-stop microbore
- Large cartridge: Masterflex L/S 14, 16, 25, 17
See tubing recommendations in the "Specifications" tab.
Cartridges must be purchased separately.
Content
1x Masterflex Reduced-Pulsation Cartridge pump head (without cartridges)
Specifications
07519-10 | 07519-15 | 07519-20 | 07519-25 | |
Flow range | 0.00005 to 350 mL/min | |||
Max rpm | 250 | 600 | 250 | 600 |
Number of rollers | 6 | 6 | 8 | 8 |
Housing material |
Polysulfone ends
|
|||
Rotor/roller material | Stainless steel / Rulon | |||
Operating temperature | 0 to 40 °C (32 to 104 °F) | |||
Weight | 2.1 kg (4.5 lb) |
Tygon E-Food and Viton (L/S sizes) are not recommended with Cartridge pump heads.
Flow range & tubing
The following tables give the expected flow range depending on the pump head for a few 2-stop microbore and L/S tubing dimensions. Values are given in mL/min.
Rollers | Max number of cartridges | Drive rpm | 0.19 mm ID | 0.89 mm ID | 2.79 mm ID | |
07519-20 | 8 | 4 small |
6 to 250 0.1 to 100 |
0.017 to 0.70 0.003 to 0.28 |
0.31 to 13 0.005 to 5.2 |
2.0 to 85 0.034 to 34 |
07519-25 | 8 | 12 small |
6 to 600 0.1 to 100 |
0.003 to 0.3 0.00005 to 0.05 |
0.062 to 6.2 0.001 to 1.0 |
0.41 to 41 0.007 to 6.8 |
Rollers | Max number of cartridges | Drive rpm | L/S 14 | L/S 16 | L/S 25 | L/S 17* | |
07519-10 | 6 | 2 large |
6 to 250 0.1 to 100 |
0.94 to 39 0.016 to 16 |
3.1 to 130 0.052 to 52 |
5.8 to 240 0.096 to 96 |
8.4 to 350 0.14 to 140 |
07519-15 | 6 | 6 large |
6 to 600 0.1 to 100 |
0.20 to 20 0.003 to 3.3 |
0.65 to 65 0.011 to 11 |
1.2 to 120 0.020 to 20 |
1.7 to 170 0.028 to 28 |
*Only silicone and C-FLEX formulations are recommended for L/S 17.
RELATED PRODUCTS
The upgrade of the standard Cartridge pump head is designed for high-precision synchronous multichannel pumping up to 12 channels. Compatible with most L/S drives.
It delivers a flow rate from 0.00005 to 350 mL/min depending on the head type and tubing size.
General
Masterflex L/S Reduced-Pulsation Cartridge pump head
The Reduced-Pulsation Cartridge pump head offers synchronous multichannel pumping over a wide range of flow rates.
- Precision molded housing
- Fast tubing changes: cartridge snap in and out easily
- 6 or 8 rollers for reduced pulsation and lower flow rates
- 1 up to 12 cartridges: 6-roller version accepts 2 or 6 large cartridges, 8-roller version accepts 4 or 12 small cartridges
- From 0.00005 to 350 mL/min and up to 600 rpm depending on the pump drive
- Adjustable occlusion optimized for each tubing size
- Compatible with 2-stop microbore or Masterflex L/S tubing
Tip: to further reduce the pulsation, cartridges can be mounted in opposite directions to balance their offset occlusion. Just connect the two tubes with a Y-connector to get the resulting flow.
Cartridge
Manufactured in polycarbonate and glass-filled nylon, the cartridges do not need any tool to be loaded on the pump head. Their occlusion “wedge” design provides accurate and more balanced flow control.
The 6-roller pump head supports 2 or 6 large cartridges, while the 8-roller pump head supports 4 or 12 small cartridges.
Compatibility:
- Small cartridge: all 2-stop microbore
- Large cartridge: Masterflex L/S 14, 16, 25, 17
See tubing recommendations in the "Specifications" tab.
Cartridges must be purchased separately.
Content
1x Masterflex Reduced-Pulsation Cartridge pump head (without cartridges)
Specifications
07519-10 | 07519-15 | 07519-20 | 07519-25 | |
Flow range | 0.00005 to 350 mL/min | |||
Max rpm | 250 | 600 | 250 | 600 |
Number of rollers | 6 | 6 | 8 | 8 |
Housing material |
Polysulfone ends
|
|||
Rotor/roller material | Stainless steel / Rulon | |||
Operating temperature | 0 to 40 °C (32 to 104 °F) | |||
Weight | 2.1 kg (4.5 lb) |
Tygon E-Food and Viton (L/S sizes) are not recommended with Cartridge pump heads.
Flow range & tubing
The following tables give the expected flow range depending on the pump head for a few 2-stop microbore and L/S tubing dimensions. Values are given in mL/min.
Rollers | Max number of cartridges | Drive rpm | 0.19 mm ID | 0.89 mm ID | 2.79 mm ID | |
07519-20 | 8 | 4 small |
6 to 250 0.1 to 100 |
0.017 to 0.70 0.003 to 0.28 |
0.31 to 13 0.005 to 5.2 |
2.0 to 85 0.034 to 34 |
07519-25 | 8 | 12 small |
6 to 600 0.1 to 100 |
0.003 to 0.3 0.00005 to 0.05 |
0.062 to 6.2 0.001 to 1.0 |
0.41 to 41 0.007 to 6.8 |
Rollers | Max number of cartridges | Drive rpm | L/S 14 | L/S 16 | L/S 25 | L/S 17* | |
07519-10 | 6 | 2 large |
6 to 250 0.1 to 100 |
0.94 to 39 0.016 to 16 |
3.1 to 130 0.052 to 52 |
5.8 to 240 0.096 to 96 |
8.4 to 350 0.14 to 140 |
07519-15 | 6 | 6 large |
6 to 600 0.1 to 100 |
0.20 to 20 0.003 to 3.3 |
0.65 to 65 0.011 to 11 |
1.2 to 120 0.020 to 20 |
1.7 to 170 0.028 to 28 |
*Only silicone and C-FLEX formulations are recommended for L/S 17.